Study guide

3.2 Grasping & Holding Instruments

CBSPD CSIS Certified Surgical Instrument Specialist Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: The CSIS Exam & Care of Surgical Instruments

1.1 CSIS Exam Blueprint, Eligibility & Logistics 1.2 Instrument Composition & Finish 1.3 Grades of Stainless Steel 1.4 Methods to Prevent Instrument Damage

2 Chapter 2: Instrument Anatomy & Naming Conventions

2.1 Anatomy of an Instrument: Jaws, Shanks & Box Locks 2.2 Instrument Naming Conventions & Classification

3 Chapter 3: General Instruments — Identification by Proper Name

3.1 Hemostatic Clamps 3.2 Grasping & Holding Instruments 3.3 Tissue & Thumb Forceps 3.4 Scissors & Other Cutting Instruments 3.5 Needle Holders & Suturing Instruments 3.6 Suction, Dilators, Probes & Accessory Instruments

4 Chapter 4: Retractors, Endoscopic, Robotic & Powered Systems

4.1 Handheld Retractors 4.2 Self-Retaining & Table-Mounted Retractors 4.3 Laparoscopic Instruments & Accessories 4.4 Robotic Instruments & Accessories 4.5 Navigational Systems & Their Instrumentation 4.6 Surgical Instrument Tracking Systems 4.7 Powered Surgical Equipment

5 Chapter 5: Specialty Instrument Sets

5.1 Orthopedic Instruments: Trauma 5.2 Orthopedic Instruments: Total Joints 5.3 Neurosurgical Instruments 5.4 Vascular & Cardiovascular-Thoracic Instruments 5.5 ENT & Dental Instruments 5.6 GU & GYN Instruments 5.7 Plastic & Microsurgical Instruments

6 Chapter 6: Components, Assembly & Configuration of Individual Sets

6.1 Instrument Make-Up for Various Sets 6.2 Count Sheets, Names & Set Configuration 6.3 Assembly Mechanics: Stringers, Protection & Weight

7 Chapter 7: Instrument Inspection & Safety Testing

7.1 Inspection for Cleanliness: Frequency 7.2 Inspection for Cleanliness: Methods 7.3 Staining, Spotting & Corrosion Identification 7.4 Testing Scissors 7.5 Testing Hinged Instruments: Box Locks & Ratchets 7.6 Testing Forceps & Clamps 7.7 Testing Needle Holders 7.8 Inspection & Testing of Laparoscopic Instruments 7.9 Insulation Inspection: Frequency 7.10 Insulation Testing: Methods

8 Chapter 8: Instrument Marking & Specialty Device Inspection

8.1 Acceptable Instrument Identification & Marking Methods 8.2 Correct Application of Instrument Marking Tape 8.3 Maintenance of Marking Methods 8.4 Inspection of Rigid & Semi-Rigid Scopes 8.5 Inspection of Flexible Scopes 8.6 Inspection of Robotic Instruments 8.7 Inspection & Testing of Power Equipment 8.8 Inspection of Harmonic Scalpels & Advanced Energy Devices 8.9 Inspection of Cameras, Light Cords & Optics 8.10 Inspection of Stereotactic Sets 8.11 Inspection of Sigmoidoscope Sets 8.12 Removal From Service, Repair & Replace Decisions

9 Chapter 9: Loaner & Implant Sets and Components

9.1 Loaner Program Fundamentals & Receipt 9.2 Inspection of Loaner Instruments 9.3 Testing of Loaner Instruments 9.4 Set Configuration of Loaner Instruments 9.5 Documentation Process for Loaner & Implant Sets

10 Chapter 10: Ethics in Surgical Instrument Processing

10.1 Professional Ethics & Accountability 10.2 Ethics of Cleanliness 10.3 Ethics of Functionality 10.4 Correct Instrument on the Set 10.5 Completeness of Sets 10.6 Reporting Instrument Damage & Abuse

3.2 Grasping & Holding Instruments

Key Takeaways Explain This Topic AI

Allis has short interlocking teeth on a slightly curved jaw and is used on tissue that will be removed; Babcock has a smooth fenestrated jaw for delicate hollow structures.

Kocher, also called Ochsner, is identified by 1x2 interlocking teeth at the jaw tip and is used on tough fascia.

Foerster sponge forceps has a ring-shaped fenestrated jaw and is the correct proper name for a sponge stick.

Backhaus towel clips have sharp crossed points that penetrate drapes; non-perforating clips are used where penetration is unacceptable.

Bone-holding clamps and Lowman and Verbrugge clamps grip bone during fixation and are inspected for both jaw grip and screw-mechanism function.

Last updated: August 2026

Holding Versus Clamping

A hemostat occludes . A grasping instrument holds . The distinction matters clinically and on the exam: applying a toothed grasper to a vessel would crush and tear it, and applying a smooth atraumatic grasper to slippery fascia would let it slip. Jaw pattern encodes which tissue the designer intended.

The Core Graspers

Instrument Jaw Typical use

Allis tissue forceps Slightly curved jaw with a row of short interlocking teeth Tissue that is being excised — bowel edge to be resected, fascia, breast tissue

Babcock tissue forceps Broad, smooth, fenestrated , rounded jaw Delicate hollow structures — bowel, ureter, fallopian tube, appendix

Kocher / Ochsner Full transverse serrations plus 1x2 teeth at the tip Tough fascia, heavy tissue that will be removed

Foerster sponge forceps Ring-shaped fenestrated jaw, serrated or smooth Holding a folded sponge for prepping or blunt dissection

  • Lahey (thyroid) tenaculum Three sharp prongs Grasping and retracting the thyroid gland
  • Jacobs / Schroeder tenaculum Sharp opposing hooks Grasping the cervix in GYN procedures
  • Backhaus towel clip Sharp crossed points Securing drapes and towels (perforating)
  • Non-perforating towel clip Blunt ball-and-socket jaw Securing drapes without penetration
  • Allis versus Babcock — a guaranteed exam pair

Think of it as traumatic versus atraumatic . Allis has teeth and grips aggressively; it is applied to tissue that will not remain in the patient. Babcock has no teeth at all — a smooth, broad, fenestrated jaw that cradles a tubular structure rather than crushing it. If an exam stem mentions bowel, appendix, ureter, or fallopian tube and asks which grasper, the answer is Babcock.

Kocher versus Ochsner

These are the same instrument under two names , and both names appear on count sheets. It is a heavy clamp with transverse serrations along the jaw and interlocking 1x2 teeth at the very tip . The teeth are the identifying feature — run a fingertip along the tip and you will feel them. Because Kocher teeth are traumatic, the instrument is used on fascia, on tissue being removed, and sometimes on a bone fragment, never on a vessel intended to survive.

Sponge Forceps

Foerster sponge forceps (the proper name for what the OR calls a sponge stick) is a ring-handled, ratcheted instrument whose jaws form two fenestrated rings. A folded 4x4 or a sponge is clamped in the rings for skin prep or for blunt dissection. Variants come straight or curved and with serrated or smooth ring faces.

Inspection point: the rings must align exactly ; a sponge stick with offset rings will drop the sponge into the wound, which becomes a retained-item event.

Towel Clips

Backhaus (perforating) towel clip : two sharp, crossed, curved points with a ratchet. Penetrates drapes and skin edges.

Non-perforating (Peers, Jones) clip : blunt ball-and-socket jaws that grip without penetration, used where a sharp point would compromise a barrier drape or injure tissue.

Sharp towel clips are a sharps hazard through the whole cycle. They are the instruments most likely to puncture a wrapper from the inside, so they are placed carefully and often tip-protected.

Bone-Holding and Reduction Clamps

Orthopedic sets add graspers built for bone rather than soft tissue.

Lowman bone-holding clamp : parallel jaws tightened by a screw and nut across a fractured bone and its plate.

Verbrugge clamp : ratcheted, curved jaws for holding a plate to bone.

Lewin, Kern, and Bishop clamps : toothed bone clamps of varying jaw geometry.

Reduction forceps ("pointed reduction") : sharp points that engage bone cortex to hold a fracture reduced.

These instruments are inspected for jaw grip, hinge integrity, and the screw or ratchet mechanism , and the screw-driven models are checked to confirm the nut turns freely along the full thread and does not seize.

Inspection Points Specific to Graspers

  • Instrument type Critical check
  • Allis Teeth intact and interlocking evenly; no bent or missing tooth
  • Babcock Jaw smooth with no burrs or nicks; fenestration edges not sharp
  • Kocher 1x2 teeth mesh precisely; a mismatched tooth means it grips and then releases
  • Sponge forceps Rings align; ratchet holds
  • Towel clips Points sharp and matched; ratchet holds; no bent point
  • Bone clamps Screw threads clean and free; jaws parallel under load

Grasp Force, Tissue Trauma and Why the Choice Is Clinical

Every grasper is a deliberate compromise between hold and harm. The exam repeatedly asks you to match an instrument to a tissue, and the reasoning is always the same: the more fragile and the more likely to be left in the patient, the more atraumatic the grasp must be.

At the traumatic end sit instruments whose teeth are meant to penetrate — Kocher, Ochsner, Lahey and Jacobs tenacula, and bone-holding clamps. They are used on tissue that is being removed, on dense fascia that will tolerate a puncture, or on bone. At the atraumatic end sit Babcock, DeBakey, Bainbridge and the vascular family, whose broad, fenestrated, or finely longitudinally serrated jaws distribute pressure so that hollow or delicate structures are not perforated. Allis sits deliberately between the two: its short interdigitating teeth hold firmly enough for tough tissue while being gentler than a full penetrating tooth.

This is why the Allis-versus-Babcock distinction is so heavily tested. Allis holds tissue that is coming out; Babcock encircles and holds tissue that is staying in, classically bowel, ureter, or fallopian tube.

Tenacula and the Specialty Graspers

Beyond the general set, several named graspers appear on specialty count sheets and reward recognition.

A tenaculum is any grasper with sharp penetrating points designed to seize and hold firm tissue for traction. The Jacobs and Schroeder uterine tenacula are standard on GYN dilatation and curettage trays; the Lahey thyroid tenaculum carries three fine prongs and appears on thyroid sets. Because their points are genuinely sharp, tenacula are inspected as sharps: bent, blunted, or mismatched prongs are a removal criterion, and the points must be protected during assembly.

Bone-holding and reduction clamps — Lowman, Verbrugge, Lewin, and the pointed reduction clamps — hold fracture fragments while hardware is applied. Many are ratcheted with a speed-lock or a threaded compression mechanism, and that mechanism is what fails: check that the ratchet advances and releases smoothly and that any threaded rod turns without binding along its whole travel.

Sponge (Foerster) forceps deserve a note because they are frequently miscounted. They may be straight or curved and smooth or serrated, and the smooth-jawed version is often reserved for prep sponges while the serrated version is used intra-operatively — two different lines on the same count sheet.