Study guide
3.3 Ischemic Changes, Injury & Infarction Patterns
CCI Certified Cardiographic Technician Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Cardiac Anatomy, Electrophysiology & Pre-Procedural Patient Care
1.1 Cardiac Anatomy & Blood Flow Pathway 1.2 Cardiac Electrophysiology & Conduction System 1.3 Pre-Procedural Patient Care, Identification & Infection Control 1.4 Cardiovascular Pharmacology & Cardiac Medications
2 Chapter 2: 12-Lead ECG Technique, Lead Placement & Technical Quality
2.1 Bipolar & Augmented Limb Leads (Einthoven's Triangle) 2.2 Precordial Lead Placement (V1-V6) & Special Lead Configurations (V7-V9, Right-Sided, Dextrocardia, Pediatric, 15-Lead) 2.3 ECG Paper Calibration, Grid Standards & Speed Settings 2.4 ECG Artifact Recognition, Signal Interference & Technical Troubleshooting
3 Chapter 3: Analyzing the 12-Lead ECG (Axis, Hypertrophy & Ischemia)
3.1 Cardiac Axis Determination & Axis Deviations 3.2 Chamber Hypertrophy (Atrial & Ventricular) 3.3 Ischemic Changes, Injury & Infarction Patterns
4 Chapter 4: ECG Waveform Analysis & Rhythm Recognition
4.1 Normal Sinus Rhythm & Sinus Node Dysrhythmias 4.2 Atrial Dysrhythmias (PACs, Atrial Fibrillation, Atrial Flutter, SVT) 4.3 Junctional Rhythmias & AV Nodal Reentry 4.4 Ventricular Dysrhythmias (PVCs, Ventricular Tachycardia, Ventricular Fibrillation, Torsades de Pointes) 4.5 Atrioventricular (AV) Blocks (1st Degree, 2nd Degree Type I/II, 3rd Degree Complete) 4.6 Intraventricular Conduction Delay, Bundle Branch Blocks & WPW Pattern 4.7 Pacemaker Rhythmias, Spike Analysis & Pacemaker Malfunctions
5 Chapter 5: Ambulatory ECG Monitoring (Holter, Event & Telemetry)
5.1 Holter Monitoring (24-48 Hour Continuous Recording) & Lead Placement 5.2 Cardiac Event Monitors, Mobile Cardiac Telemetry (MCT), Patch Recorders & Implantable Loop Recorders 5.3 Patient Diary Correlation, Symptom Tracking & Data Analysis
6 Chapter 6: Exercise & Pharmacologic Cardiac Stress Testing
6.1 Treadmill Stress Test Protocols 6.2 Target Heart Rate Calculation, Hemodynamic Monitoring & Test Termination Criteria 6.3 Pharmacologic Stress Testing Agents 6.4 Complications & Emergency Protocols During Stress Testing
7 Chapter 7: Equipment Quality Control, Calibration & Compliance Standards
7.1 Equipment Calibration, Voltage Standards & Frequency Filters 7.2 Electrical Safety, Patient Grounding & Equipment Maintenance 7.3 Quality Assurance, Documentation & HIPAA/Regulatory Compliance
3.3 Ischemic Changes, Injury & Infarction Patterns
Key Takeaways Explain This Topic AI
Ischemia often produces inverted, symmetric T waves; acute injury produces ST elevation (STEMI pattern) or significant ST depression; infarction evolves pathologic Q waves.
Anterior STEMI localizes to V1–V4 (LAD), inferior to II/III/aVF (usually RCA), and lateral to I/aVL/V5–V6 (LCX or diagonal).
STEMI criteria include new ST elevation at the J point in two contiguous leads (commonly ≥1 mm in limb leads; ≥2 mm in V2–V3 for men ≥40 is a frequently tested threshold family—know contiguous-lead logic).
Reciprocal ST depression supports acute injury; posterior MI may show anterior ST depression with tall R waves in V1–V2 and is confirmed with V7–V9.
Last updated: July 2026
Ischemic Changes, Injury & Infarction Patterns
Identify ischemic changes/infarction is a core CCI CCT analysis task. Cardiographic technicians are often the first professionals to see a tracing that should trigger a STEMI alert. You must recognize the waveform stages of acute coronary syndrome, map ST-T changes to coronary territories, and know when to add right-sided or posterior leads.
The Ischemia–Injury–Infarction Continuum
Stage Typical ECG Signature Pathophysiology (Exam Level)
Ischemia Symmetrical T-wave inversion; or tall, peaked (hyperacute) T waves early Incomplete perfusion; repolarization abnormal
- Injury ST-segment elevation or depression Acute transmural or subendocardial injury current
- Infarction Pathologic Q waves (± evolving ST/T changes) Myocardial necrosis
These stages can coexist on one ECG because different regions may be at different points in the timeline.
ST Segments and Contiguous Leads
ST deviation is measured at the J point (QRS end / ST start) relative to the TP or PR baseline.
Contiguous leads view anatomically adjacent walls:
- Inferior: II, III, aVF
- Anterior/septal: V1–V4
- Lateral: I, aVL, V5–V6
- Posterior: V7–V9 (or infer from V1–V3 mirror images)
Acute injury is reported when ST elevation (or equivalent) appears in two or more contiguous leads . Exact millimeter cutoffs vary slightly by lead, sex, and age in full clinical guidelines; for CCT mastery, emphasize contiguous-lead logic , territory maps, and reciprocal changes rather than memorizing every sex-specific millimeter table.
Territory Localization Table
- Infarct Territory Leads with ST Elevation / Q Waves Culprit Artery (Most Common)
- Septal V1–V2 Proximal LAD
- Anterior V3–V4 LAD
- Anterolateral V3–V6, I, aVL Mid/proximal LAD or diagonal
- Inferior II, III, aVF RCA (≈80%) or LCX
- Lateral I, aVL, V5–V6 LCX or diagonal
- Posterior V7–V9 (mirror: ST depression V1–V3) RCA or LCX
- Right ventricle V3R–V6R (especially V4R ) Proximal RCA
- STEMI Pattern Recognition
STEMI-pattern injury:
- Convex or straight ST elevation in an anatomic group of leads
- Often with reciprocal ST depression in opposite leads
- May begin with hyperacute T waves before frank ST elevation
Reciprocal change example: Inferior ST elevation in II/III/aVF with ST depression in aVL strongly supports acute inferior injury rather than early repolarization mimicry.
NSTE-ACS Patterns
Not all ischemia elevates the ST segment:
- Horizontal or downsloping ST depression ≥ 1 mm in two contiguous leads
- Deep symmetrical T-wave inversion
- Transient ST elevation that resolves
These patterns still require urgent clinical evaluation even when a formal STEMI activation pathway is not met.
Pathologic Q Waves
A pathologic Q wave suggests myocardial necrosis (age may be acute, recent, or old):
Common teaching thresholds: Q wave ≥ 0.04 seconds (1 small box) wide and/or ≥ 25% of the following R-wave height in a lead that should not normally have a deep Q.
Small septal q waves in I, aVL, V5–V6 can be normal.
- Posterior and Right-Ventricular Extensions
- Posterior MI
Anterior leads may show:
- Horizontal ST depression in V1–V3
- Tall R waves in V1–V2
- Upright T waves in V1–V2
Confirm with posterior leads V7–V9 . Do not dismiss isolated anterior ST depression as "nonspecific" without considering posterior injury.
Right-Ventricular MI
Suspect with inferior STEMI, especially when III shows more elevation than II. Record right-sided leads ; V4R is the highest-yield single lead. RV infarction changes preload management, so early recognition matters.
- Common STEMI Mimics Technicians Should Flag Carefully
- Early repolarization (young patients; concave ST elevation, no reciprocal depression)
- Pericarditis (diffuse ST elevation, PR depression)
LBBB or paced rhythm (use lab protocols for Sgarbossa/modified criteria; do not "clear" these tracings casually)
- Hyperkalemia (wide QRS, peaked T waves)
- Lead misplacement
When uncertain, obtain a technically perfect repeat ECG, compare with priors, and escalate per facility STEMI pathway.
Technician Action Checklist
Ensure accurate lead placement—false infarct patterns are commonly technical.
Print a baseline-stable tracing without tremor or wander.
If inferior STEMI pattern appears, add right-sided leads.
If posterior MI is suspected, add V7–V9.
Notify the supervising nurse/physician immediately for STEMI-criteria tracings; time stamps and serial ECGs (every 10–15 minutes when symptoms persist) are part of quality care.
Never delete an abnormal tracing because it "looks wrong"—document and escalate.
Ischemia and infarction recognition is where ECG technique meets emergency action. Pair this section with coronary anatomy (LAD/RCA/LCX territories) and special lead placement (V4R, V7–V9) for complete Domain C coverage.