Study guide

2.2 The Cardiac Conduction System, Action Potentials & Ion Channel Physiology

Registered Cardiac Electrophysiology Specialist RCES

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Pre-Procedural Assessment & Patient Preparation

1.1 Procedure Room Preparation, Equipment Verification & Aseptic Readiness 1.2 Pre-Procedural Clinical Evaluation, Labs, Consents & The Universal Time-Out 1.3 Patient Identification, Transport, HIPAA & Procedural Documentation 1.4 Patient Monitoring Setup, Defibrillator Pads & Pre-Procedural CIED Interrogation 1.5 Vascular Access Planning, Skin Preparation & Sterile Draping

2 Chapter 2: Cardiac Anatomy, Conduction & Electrophysiologic Foundations

2.1 Cardiac Anatomy for the EP Lab: Chambers, Access Routes & Coronary Supply 2.2 The Cardiac Conduction System, Action Potentials & Ion Channel Physiology 2.3 Cardiac Vector Analysis, 12-Lead ECG Fundamentals & Axis Determination

3 Chapter 3: EP Lab Instrumentation, Connectology & Lab Safety

3.1 EP Recording System Architecture, Signal Amplification & Frequency Filters 3.2 Cardiac Stimulator Operation, Junction Box Routing & Noise Troubleshooting 3.3 Electrical Safety, Electrical Units, Electrocautery & Fire Safety 3.4 Radiation Safety Physics, ALARA Principles, Shielding & Dose Limits 3.5 Procedural Supplies, Catheter Inventory, Surgical Instrumentation & Wound Closure

4 Chapter 4: Intra-Procedural Imaging, Sedation & Physiologic Monitoring

4.1 Fluoroscopic Projections (RAO, LAO, AP) & X-ray Tube Optimization 4.2 Intracardiac Echocardiography (ICE) Principles, Views & Catheter Navigation 4.3 Non-Radiographic Imaging: Cardiac CT/MRI, Image Fusion & Ultrasound-Guided Access 4.4 Conscious Sedation Protocols, Airway Management & Hemodynamic Monitoring 4.5 Vital Signs, Normal Laboratory Values & Intra-Procedural Lab Monitoring

5 Chapter 5: EP Pharmacology, Anticoagulation & Emergency Drugs

5.1 Vaughan Williams Antiarrhythmic Classification & EP Electrophysiology 5.2 Diagnostic & Provocative Drugs: Adenosine, Isoproterenol, Epinephrine, Atropine 5.3 Sedation & Analgesia Pharmacology, Reversal Agents & Recovery Scoring 5.4 Heparin Protocol, ACT Monitoring & Emergency Reversal with Protamine 5.5 Oral Anticoagulants, Antiplatelets & Peri-Procedural Management 5.6 ACLS Algorithms & Emergency Medications in the EP Lab

6 Chapter 6: Catheter Navigation, Normal Electrograms & Baseline Intervals

6.1 Standard Diagnostic Catheter Positions & Fluoroscopic/Anatomical Landmarks 6.2 Intracardiac Electrogram Interpretation & Normal Baseline Intervals (PA, AH, HV) 6.3 His Bundle Electrogram Recording, Split His Potentials & Infranodal Conduction

7 Chapter 7: Programmed Electrical Stimulation & Refractory Periods

7.1 Pacing Stimulation Fundamentals, Capture Thresholds & Drive Trains 7.2 Refractory Period Determination (ERP, RRP, FRP) & Sinus Node Function Testing (SNRT, cSNRT) 7.3 AV Nodal Decremental Conduction & Dual AV Nodal Physiology

8 Chapter 8: Diagnostic Evaluation of Supraventricular & Ventricular Tachycardias

8.1 Narrow-Complex Tachycardias: Differential Diagnosis of AVNRT, AVRT & AT 8.2 Diagnostic Pacing Maneuvers: Entrainment, PPI-TCL, V-A-V vs V-A-A-V & His-Refractory PVCs 8.3 Wide-Complex Tachycardias & Ventricular Arrhythmia Mapping Criteria

9 Chapter 9: Bradyarrhythmias, AV Block & Atrial Arrhythmia Recognition

9.1 Bradyarrhythmias, AV Block Classification & Conduction System Disease 9.2 Atrial Fibrillation & Atrial Flutter: Classification, ECG Recognition & Stroke Risk

10 Chapter 10: 3D Electroanatomic Mapping & Ablation Biophysics

10.1 3D Electroanatomic Mapping Systems (Carto, EnSite, Rhythmia) Setup & Troubleshooting 10.2 Activation, Propagation & Bipolar Voltage Substrate Mapping 10.3 Ablation Biophysics: Radiofrequency, Cryoablation & Pulsed Field Ablation (PFA)

11 Chapter 11: Transseptal Access, Catheter Ablation Targets & Endpoints

11.1 Transseptal Puncture: Anatomy, Technique, Imaging Guidance & Complications 11.2 Catheter Ablation of AVNRT Slow Pathway & Accessory Pathways (WPW) 11.3 Cavotricuspid Isthmus (CTI) Ablation for Typical Atrial Flutter 11.4 Pulmonary Vein Isolation (PVI) for AFib & Ventricular Tachycardia Ablation

12 Chapter 12: Cardiac Implantable Electronic Devices: Implantation & Testing

12.1 Pacemaker & Transvenous ICD Implantation Techniques & Safety 12.2 Intra-Procedural Electrical Testing: Sensing, Pacing Thresholds, Impedance & DFT 12.3 Cardiac Resynchronization Therapy (CRT) & Conduction System Pacing (HBP, LBBAP)

13 Chapter 13: CIED Interrogation, Programming & Troubleshooting

13.1 NBG Pacemaker Codes, Pacing Modes & Timing Cycles 13.2 CIED Interrogation Workflow, Programmer Operation & Peri-Procedural Reprogramming 13.3 Interpreting & Conveying Interrogated Data: Diagnostics, Counters & Stored Episodes 13.4 Pacing & Sensing Malfunctions, Electromagnetic Interference & Temporary Pacing

14 Chapter 14: Specialized Devices, Extraction & Acute Procedural Emergencies

14.1 Subcutaneous ICD (S-ICD), Leadless Pacemakers & Left Atrial Appendage Closure 14.2 Transvenous Lead Extraction Tools, Techniques & Safety Precautions 14.3 Acute Procedural Emergencies: Perforation, Tamponade, Pericardiocentesis & Air Embolism

15 Chapter 15: Post-Procedural Care, Hemostasis & Complication Management

15.1 Femoral Hemostasis Techniques: Manual Compression, Figure-of-8 & Closure Devices 15.2 Post-Procedural Complications: Vascular Injury, AV Block, Esophageal Injury & Neurologic Deficits 15.3 Post-Procedural CIED Assessment, Device Follow-Up & Wound Care 15.4 Post-Procedure Patient Recovery, Discharge Education & Clinical Handover

2.2 The Cardiac Conduction System, Action Potentials & Ion Channel Physiology

Key Takeaways Explain This Topic AI

Fast-response tissue (atrium, His-Purkinje, ventricle) depolarizes through the fast sodium current with a phase 0 upstroke of 200-1,000 V/s; slow-response tissue (SA and AV node) uses L-type calcium current at 1-10 V/s.

The funny current If, activated by hyperpolarization and accelerated by cyclic AMP, drives phase 4 diastolic depolarization and is the molecular target of ivabradine.

Intrinsic rates fall progressively down the conduction hierarchy: SA node 60-100, AV junction 40-60, His-Purkinje 20-40 beats per minute.

Decremental conduction in the AV node comes from calcium-channel-dependent slow-response tissue, which is why the AH interval prolongs with faster pacing while the HV interval does not.

Early afterdepolarizations arise in phase 2-3 and are bradycardia- and hypokalemia-dependent (torsades); delayed afterdepolarizations arise after phase 3 from calcium overload (digoxin toxicity, CPVT).

Last updated: September 2026

2.2 The Cardiac Conduction System, Action Potentials & Ion Channel Physiology

Every number an RCES specialist measures — the AH interval, the effective refractory period, the sinus node recovery time, the response to adenosine — is a measurement of the physiology in this section. CCI's knowledge list names the cardiac conduction system , cardiac anatomy and physiology , cardiac pathophysiology , and normal intracardiac EGM and ECG interval values as testable areas.

1. The Conduction Hierarchy

  • Structure Location Conduction velocity Intrinsic rate
  • Sinoatrial (SA) node Subepicardial, SVC–RA junction along the superior crista terminalis ~0.05 m/s 60-100 bpm

Atrial myocardium / internodal routes Right atrium; Bachmann's bundle carries the impulse to the left atrium ~1 m/s —

  • AV node Apex of the triangle of Koch ~0.05 m/s (slowest) 40-60 bpm (AV junction)
  • Bundle of His Penetrates the central fibrous body ~1.5 m/s 40-60 bpm
  • Bundle branches Right bundle; left bundle dividing into anterior and posterior fascicles ~2 m/s 20-40 bpm
  • Purkinje network Subendocardial arborization ~2-4 m/s (fastest) 20-40 bpm
  • Ventricular myocardium Working muscle ~0.3-1 m/s —

Two properties of this table are constantly tested. The AV node is the slowest conducting tissue , and its delay is functional, not incidental: it produces the PR interval, allows atrial contribution to ventricular filling, and protects the ventricle from rapid atrial rates. The Purkinje system is the fastest , which is why a supraventricular impulse produces a narrow QRS while a ventricular focus, spreading muscle-to-muscle, produces a wide one.

The AV node and His bundle are the only normal electrical connection between atria and ventricles; the fibrous annuli insulate everything else. An accessory pathway is, by definition, a breach of that insulation.

2. The Fast-Response Action Potential

Atrial muscle, His-Purkinje tissue, and ventricular muscle share a five-phase action potential.

  • Phase Event Dominant current Direction
  • 0 Rapid upstroke INa (fast sodium) Inward
  • 1 Early rapid repolarization (notch) Ito (transient outward K⁺) Outward
  • 2 Plateau ICa-L (L-type calcium) balanced against IK Inward = outward
  • 3 Repolarization IKr and IKs (delayed rectifier K⁺) Outward
  • 4 Resting potential IK1 (inward rectifier K⁺) Outward

Resting membrane potential is about −90 mV , maintained by IK1 and the Na⁺/K⁺ ATPase , which extrudes three sodium ions for every two potassium ions imported and is therefore electrogenic (net outward, hyperpolarizing).

Phase 0 upstroke velocity ( dV/dt ) is 200-1,000 V/s , and it determines conduction velocity. Anything that reduces sodium current — class I antiarrhythmics, hyperkalemia, ischemic depolarization — slows conduction and widens the QRS.

Phase 2 calcium entry triggers calcium-induced calcium release from the sarcoplasmic reticulum through the ryanodine receptor ( RyR2 ), coupling excitation to contraction.

3. The Slow-Response Action Potential

Sinus node and AV nodal cells behave completely differently, and the difference explains most of EP pharmacology.

  • Property Fast response Slow response (SA/AV node)
  • Maximum diastolic potential −90 mV −50 to −65 mV
  • Phase 0 current INa ICa-L (calcium)
  • Phase 0 upstroke 200-1,000 V/s 1-10 V/s
  • Phase 4 Flat (non-pacemaker) Spontaneous depolarization
  • Conduction Fast, non-decremental Slow, decremental
  • Recovery of excitability Voltage-dependent Time-dependent

Because nodal cells rest near −55 mV, their fast sodium channels are permanently inactivated; they must use the slower calcium current. That single fact produces three consequences the exam tests relentlessly:

Decremental conduction. Recovery is time-dependent, so the earlier an impulse arrives, the longer it takes to conduct. This is why the AH interval lengthens as the A1-A2 coupling interval shortens, and why the AV node is the substrate for AV nodal reentry.

Calcium channel blockers and beta blockers work on the node , and adenosine hyperpolarizes it through IKACh — all three slow AV conduction while leaving His-Purkinje conduction untouched.

The HV interval does not prolong with faster pacing in a normal His-Purkinje system, because that tissue is fast-response and non-decremental. HV prolongation with pacing is pathologic.

Phase 4 automaticity and the funny current

Spontaneous phase 4 depolarization in pacemaker cells is driven by If , the "funny" current — an inward mixed sodium-potassium current carried by HCN channels, activated paradoxically by hyperpolarization and accelerated by intracellular cyclic AMP .

Sympathetic stimulation (β₁ receptors → increased cAMP) steepens the phase 4 slope → faster rate.

Vagal stimulation (M₂ receptors → decreased cAMP, plus IKACh-mediated hyperpolarization) flattens the slope and lowers maximum diastolic potential → slower rate.

Ivabradine blocks If selectively, slowing the sinus rate without inotropic or AV nodal effects.

Overdrive suppression: rapid pacing loads the cell with sodium, stimulating the electrogenic Na⁺/K⁺ ATPase, whose net outward current hyperpolarizes the cell and transiently suppresses automaticity. This is the mechanism measured by the sinus node recovery time.

4. Refractoriness

Term Definition

Absolute refractory period (ARP) No stimulus of any strength produces a response; sodium channels are fully inactivated

Effective refractory period (ERP) The longest coupling interval that fails to produce a propagated response — the clinically measured quantity

Relative refractory period (RRP) A stronger-than-normal stimulus produces a slowed, reduced response

Supernormal period Late phase 3, where a subthreshold stimulus can capture — the basis for occasional paradoxical capture in a failing pacing system

Vulnerable period Peak-to-downslope of the T wave; a stimulus here can induce ventricular fibrillation (the R-on-T phenomenon)

Refractoriness in fast-response tissue is voltage-dependent — it recovers as the membrane repolarizes, so it shortens at faster rates as the action potential duration shortens. Refractoriness in nodal tissue is time-dependent and lengthens with faster rates. That opposite behavior is the reason rapid atrial pacing produces AV Wenckebach rather than 1:1 conduction, and it is why an accessory pathway — which is fast-response, working-muscle-like tissue — conducts faster as atrial rate increases, making pre-excited atrial fibrillation lethal.

5. Autonomic Modulation

  • Effect Sympathetic (β₁, norepinephrine) Parasympathetic (M₂, acetylcholine)
  • Chronotropy (SA rate) ↑ ↓
  • Dromotropy (AV conduction) ↑ ↓
  • Inotropy ↑ Minimal ventricular effect
  • Refractoriness ↓ ↑ at AV node
  • Distribution Atria and ventricles Predominantly atria and AV node

Vagal innervation is dense at the SA and AV nodes and sparse in the ventricle, which is why carotid sinus massage and the Valsalva maneuver terminate AV-nodal-dependent tachycardias but do nothing to ventricular tachycardia.

6. Arrhythmia Mechanisms

The exam expects clean separation of three mechanisms.

1. Abnormal automaticity. A focus depolarizes spontaneously and faster than the sinus node. It warms up and cools down , cannot be initiated or terminated by programmed stimulation, and is often catecholamine-sensitive. Examples: sinus tachycardia, some focal atrial tachycardias, accelerated idioventricular rhythm.

2. Triggered activity. Afterdepolarizations reach threshold and generate a new action potential. Two forms:

  • Early afterdepolarization (EAD) Delayed afterdepolarization (DAD)
  • Timing During phase 2 or 3, before repolarization completes After phase 3, during phase 4

Setting Prolonged action potential: bradycardia, hypokalemia, hypomagnesemia, QT-prolonging drugs, congenital long QT Calcium overload: digoxin toxicity, catecholamines, ischemia-reperfusion, CPVT

Rate dependence Pause/bradycardia-dependent Tachycardia-dependent

Clinical arrhythmia Torsades de pointes Digoxin-toxic atrial tachycardia with block; CPVT bidirectional VT; some RVOT VT

3. Reentry. By far the most common mechanism and the basis of nearly every ablated arrhythmia. Reentry requires three conditions simultaneously:

Two anatomically or functionally distinct pathways forming a circuit.

Unidirectional block in one limb.

Slow conduction in the other limb, long enough that the blocked limb recovers excitability before the wavefront returns. Premature beat

  • |
  • v
  • [ Common proximal pathway ]
  • / \
  • Fast pathway Slow pathway
  • (BLOCKED - long ERP) (conducts slowly)
  • ^ |
  • | v
  • +---- retrograde <-+ ==> sustained reentry

Reentrant arrhythmias are reproducibly initiated and terminated by programmed stimulation , can be entrained , and have a fixed excitable gap — the three features exploited in every diagnostic pacing maneuver. AVNRT, AVRT, typical atrial flutter, and post-infarction ventricular tachycardia are all reentrant.