Study guide

6.3 His Bundle Electrogram Recording, Split His Potentials & Infranodal Conduction

Registered Cardiac Electrophysiology Specialist RCES

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Pre-Procedural Assessment & Patient Preparation

1.1 Procedure Room Preparation, Equipment Verification & Aseptic Readiness 1.2 Pre-Procedural Clinical Evaluation, Labs, Consents & The Universal Time-Out 1.3 Patient Identification, Transport, HIPAA & Procedural Documentation 1.4 Patient Monitoring Setup, Defibrillator Pads & Pre-Procedural CIED Interrogation 1.5 Vascular Access Planning, Skin Preparation & Sterile Draping

2 Chapter 2: Cardiac Anatomy, Conduction & Electrophysiologic Foundations

2.1 Cardiac Anatomy for the EP Lab: Chambers, Access Routes & Coronary Supply 2.2 The Cardiac Conduction System, Action Potentials & Ion Channel Physiology 2.3 Cardiac Vector Analysis, 12-Lead ECG Fundamentals & Axis Determination

3 Chapter 3: EP Lab Instrumentation, Connectology & Lab Safety

3.1 EP Recording System Architecture, Signal Amplification & Frequency Filters 3.2 Cardiac Stimulator Operation, Junction Box Routing & Noise Troubleshooting 3.3 Electrical Safety, Electrical Units, Electrocautery & Fire Safety 3.4 Radiation Safety Physics, ALARA Principles, Shielding & Dose Limits 3.5 Procedural Supplies, Catheter Inventory, Surgical Instrumentation & Wound Closure

4 Chapter 4: Intra-Procedural Imaging, Sedation & Physiologic Monitoring

4.1 Fluoroscopic Projections (RAO, LAO, AP) & X-ray Tube Optimization 4.2 Intracardiac Echocardiography (ICE) Principles, Views & Catheter Navigation 4.3 Non-Radiographic Imaging: Cardiac CT/MRI, Image Fusion & Ultrasound-Guided Access 4.4 Conscious Sedation Protocols, Airway Management & Hemodynamic Monitoring 4.5 Vital Signs, Normal Laboratory Values & Intra-Procedural Lab Monitoring

5 Chapter 5: EP Pharmacology, Anticoagulation & Emergency Drugs

5.1 Vaughan Williams Antiarrhythmic Classification & EP Electrophysiology 5.2 Diagnostic & Provocative Drugs: Adenosine, Isoproterenol, Epinephrine, Atropine 5.3 Sedation & Analgesia Pharmacology, Reversal Agents & Recovery Scoring 5.4 Heparin Protocol, ACT Monitoring & Emergency Reversal with Protamine 5.5 Oral Anticoagulants, Antiplatelets & Peri-Procedural Management 5.6 ACLS Algorithms & Emergency Medications in the EP Lab

6 Chapter 6: Catheter Navigation, Normal Electrograms & Baseline Intervals

6.1 Standard Diagnostic Catheter Positions & Fluoroscopic/Anatomical Landmarks 6.2 Intracardiac Electrogram Interpretation & Normal Baseline Intervals (PA, AH, HV) 6.3 His Bundle Electrogram Recording, Split His Potentials & Infranodal Conduction

7 Chapter 7: Programmed Electrical Stimulation & Refractory Periods

7.1 Pacing Stimulation Fundamentals, Capture Thresholds & Drive Trains 7.2 Refractory Period Determination (ERP, RRP, FRP) & Sinus Node Function Testing (SNRT, cSNRT) 7.3 AV Nodal Decremental Conduction & Dual AV Nodal Physiology

8 Chapter 8: Diagnostic Evaluation of Supraventricular & Ventricular Tachycardias

8.1 Narrow-Complex Tachycardias: Differential Diagnosis of AVNRT, AVRT & AT 8.2 Diagnostic Pacing Maneuvers: Entrainment, PPI-TCL, V-A-V vs V-A-A-V & His-Refractory PVCs 8.3 Wide-Complex Tachycardias & Ventricular Arrhythmia Mapping Criteria

9 Chapter 9: Bradyarrhythmias, AV Block & Atrial Arrhythmia Recognition

9.1 Bradyarrhythmias, AV Block Classification & Conduction System Disease 9.2 Atrial Fibrillation & Atrial Flutter: Classification, ECG Recognition & Stroke Risk

10 Chapter 10: 3D Electroanatomic Mapping & Ablation Biophysics

10.1 3D Electroanatomic Mapping Systems (Carto, EnSite, Rhythmia) Setup & Troubleshooting 10.2 Activation, Propagation & Bipolar Voltage Substrate Mapping 10.3 Ablation Biophysics: Radiofrequency, Cryoablation & Pulsed Field Ablation (PFA)

11 Chapter 11: Transseptal Access, Catheter Ablation Targets & Endpoints

11.1 Transseptal Puncture: Anatomy, Technique, Imaging Guidance & Complications 11.2 Catheter Ablation of AVNRT Slow Pathway & Accessory Pathways (WPW) 11.3 Cavotricuspid Isthmus (CTI) Ablation for Typical Atrial Flutter 11.4 Pulmonary Vein Isolation (PVI) for AFib & Ventricular Tachycardia Ablation

12 Chapter 12: Cardiac Implantable Electronic Devices: Implantation & Testing

12.1 Pacemaker & Transvenous ICD Implantation Techniques & Safety 12.2 Intra-Procedural Electrical Testing: Sensing, Pacing Thresholds, Impedance & DFT 12.3 Cardiac Resynchronization Therapy (CRT) & Conduction System Pacing (HBP, LBBAP)

13 Chapter 13: CIED Interrogation, Programming & Troubleshooting

13.1 NBG Pacemaker Codes, Pacing Modes & Timing Cycles 13.2 CIED Interrogation Workflow, Programmer Operation & Peri-Procedural Reprogramming 13.3 Interpreting & Conveying Interrogated Data: Diagnostics, Counters & Stored Episodes 13.4 Pacing & Sensing Malfunctions, Electromagnetic Interference & Temporary Pacing

14 Chapter 14: Specialized Devices, Extraction & Acute Procedural Emergencies

14.1 Subcutaneous ICD (S-ICD), Leadless Pacemakers & Left Atrial Appendage Closure 14.2 Transvenous Lead Extraction Tools, Techniques & Safety Precautions 14.3 Acute Procedural Emergencies: Perforation, Tamponade, Pericardiocentesis & Air Embolism

15 Chapter 15: Post-Procedural Care, Hemostasis & Complication Management

15.1 Femoral Hemostasis Techniques: Manual Compression, Figure-of-8 & Closure Devices 15.2 Post-Procedural Complications: Vascular Injury, AV Block, Esophageal Injury & Neurologic Deficits 15.3 Post-Procedural CIED Assessment, Device Follow-Up & Wound Care 15.4 Post-Procedure Patient Recovery, Discharge Education & Clinical Handover

6.3 His Bundle Electrogram Recording, Split His Potentials & Infranodal Conduction

Key Takeaways Explain This Topic AI

Recording an authentic His bundle electrogram requires stable catheter positioning across the tricuspid annulus, yielding an A:V ratio of 1:2 to 1:1 and a sharp, discrete His potential (<30 ms duration) free from mechanical injury.

Proximal His recordings display larger atrial deflections and precede distal His deflections, whereas distal His recordings show larger ventricular deflections that can merge into the ventricular electrogram or mimic right bundle potentials.

Differentiating a true His spike from a right bundle branch (RBB) potential relies on timing (RB-V interval is <30 ms, typically 10-25 ms, vs. HV 35-55 ms), anatomical location (RBB is more distal/apical along the septum), and pacing morphology.

Split His potentials (H and H' deflections separated by >30-40 ms within a single cardiac cycle) indicate intra-Hisian conduction delay secondary to longitudinal dissociation or focal lesions within the His bundle trunk.

Intracardiac electrograms definitively localize AV block: AV nodal block occurs proximal to the His spike (A without H), intra-Hisian block occurs between split His potentials (A-H without H'-V), and infra-Hisian block occurs distal to the His spike (A-H without V).

Last updated: September 2026

6.3 His Bundle Electrogram Recording, Split His Potentials & Infranodal Conduction

The bundle of His is a compact cylindrical fascicle of specialized conduction tissue approximately 15 to 20 mm in length. Originating at the anterior-superior apex of the triangle of Koch, it penetrates the central fibrous body (where it is termed the penetrating bundle ), courses along the crest of the muscular interventricular septum beneath the membranous septum, and bifurcates into the left and right bundle branches ( branching bundle ).

Recording and interpreting potentials from this specialized conduit is essential for evaluating complex conduction disturbances. Dissecting whether an atrioventricular block is suprahisian (AV nodal), intra-Hisian (within the His trunk), or infra-Hisian (within the distal bundle branches) determines whether the patient requires urgent permanent pacing or can be managed conservatively.

Technical Challenges in His Bundle Recording

Navigating a diagnostic catheter to record a reproducible His bundle electrogram requires fine mechanical manipulation and continuous real-time electrogram analysis:

Catheter Manipulation Technique : Via femoral venous access, a steerable or pre-curved quadripolar catheter is advanced across the tricuspid valve into the right ventricle under fluoroscopy. The catheter is curled slightly toward the interventricular septum with gentle clockwise torque. As the catheter is slowly withdrawn across the septal leaflet of the tricuspid valve into the right atrium, the operator observes the electrograms transition from a pure ventricular deflection ( V V V ) to an electrogram exhibiting an atrial deflection ( A A A ), a His potential ( H H H ), and a ventricular deflection ( V V V ).

Proximal vs. Distal His Bundle Recordings :

Proximal His Recording : Positioned at the non-branching penetrating bundle adjacent to the compact AV node. Displays a prominent atrial electrogram ( A : V ≥ 1 : 1 A:V \ge 1:1 A : V ≥ 1 : 1 ), a sharp His spike, and a longer, true HV interval. In pacing maneuvers, pacing the proximal His often requires higher outputs and may capture adjacent low atrial tissue.

Distal His Recording : Positioned along the branching segment near the bundle bifurcation. Displays a diminutive atrial electrogram ( A : V < 0.5 : 1 A:V < 0.5:1 A : V < 0.5 : 1 ) and a large ventricular electrogram. The His potential lies closer to the V V V wave, which increases the risk of the His spike blending into the ventricular electrogram, obscuring the true onset of infranodal conduction.

Catheter Instability & Micro-Dislodgement : Because the tricuspid annulus moves dynamically with cardiac contraction and respiration, the catheter tip can shift by millimeters. A minor backward displacement causes complete loss of the His spike (recording only low RA); minor forward displacement into the RV causes the His spike to merge into the ventricular complex or captures an isolated right bundle branch potential.

Validating True His Deflection vs. Right Bundle Branch (RBB) Potential

A critical diagnostic pitfall in the EP laboratory is mistaking a right bundle branch (RBB) potential for a true His bundle deflection. Because the RBB courses subendocardially along the right ventricular septum toward the base of the anterior papillary muscle, a catheter advanced slightly too far into the RV apex can record an RBB spike that mimics a His deflection with an abnormally short HV interval. True His Bundle Recording: (A) -------- (H) ------------------------ (V)

  • | |
  • +-------- HV: 35 - 55 ms ----+
  • Right Bundle Branch Recording: [Tiny A] (RB) --------------- (V)
  • | |
  • +--- RB-V: 10-25 ms +
  • Diagnostic Criteria for Differentiation
  • Electrographic Feature True His Bundle Potential ( H H H ) Right Bundle Branch Potential ( R B RB RB )
  • Conduction Interval HV interval = 35 - 55 ms RB-V interval = 10 - 25 ms (strictly <30 ms)

Atrial Electrogram ( A A A ) Prominent ( A : V ≈ 1 : 2 to 1 : 1 A:V \approx 1:2\text{ to }1:1 A : V ≈ 1 : 2 to 1 : 1 ) Absent or tiny far-field atrial signal ( A : V < 0.2 : 1 A:V < 0.2:1 A : V < 0.2 : 1 )

Anatomical Position Superior-anterior triangle of Koch at tricuspid annulus More apical, distal, and inferior along the right ventricular septum

Precordial V6 Relation H H H potential precedes surface QRS by ≥ 35 ms \ge 35\text{ ms} ≥ 35 ms R B RB RB potential precedes local RV activation but may align with surface QRS onset

Pacing Response Selective His capture yields narrow QRS matching intrinsic conduction Pacing yields complete LBBB morphology with wide, delayed left ventricular activation

Pacing Validation: Selective vs. Non-Selective His Capture

Pacing through the recording bipole provides definitive physical validation of the His potential:

Selective His Bundle Pacing : Low-output stimulation captures only the His bundle. The resulting surface QRS complex is completely normal, identical in duration and morphology to intrinsic conduction, preceded by an isoelectric interval matching the intrinsic HV interval.

Non-Selective His Bundle Pacing : Stimulation captures both the His bundle and adjacent septal myocardium. The QRS displays a pseudo-delta wave (local myocardial capture) but retains a narrow terminal portion due to rapid activation via the specialized Purkinje network.

RBB Pacing : Stimulation captures the right bundle branch, producing an artificial left bundle branch block (LBBB) pattern with broad QRS (>120 ms) and delayed left ventricular activation.

Intra-Hisian Conduction Disease & Split His Potentials ( H − H ′ H-H' H − H ′ )

Under pathological conditions, the common bundle of His can develop localized, intramural conduction slowing or functional block. This phenomenon gives rise to split His potentials , designated as H H H and H ′ H' H ′ .

Pathophysiological Mechanisms

Longitudinal Dissociation : Anatomical and electrophysiological studies (originally described by Damato, Narula, and Scherlag) demonstrate that fibers within the His bundle trunk are organized into distinct, longitudinally insulated channels destined for the right and left bundles. Fine connective tissue septa isolate these fascicular tracts. Focal fibrocalcific degeneration, ischemia, or mechanical trauma can selectively slow conduction along one tract while sparing another.

Transverse Lesions / Focal Conduction Block : A micro-lesion across the trunk divides the His bundle into a proximal His segment ( H H H ) proximal to the diseased zone and a distal His segment ( H ′ H' H ′ ) distal to the diseased zone.

Electrographic Manifestations

Morphology : Two separate, distinct, high-frequency spikes ( H H H and H ′ H' H ′ ) recorded within a single cardiac cycle between the atrial deflection ( A A A ) and the ventricular deflection ( V V V ).

Diagnostic Threshold : A split His potential is diagnosed when the H − H ′ H-H' H − H ′ interval exceeds 30 to 40 ms .

Segmental Timing :

The A − H A-H A − H interval reflects conduction from the low RA to the proximal His segment.

The H − H ′ H-H' H − H ′ interval reflects conduction delay across the diseased intra-Hisian segment.

The H ′ − V H'-V H ′ − V interval reflects conduction from the distal His segment to the ventricular myocardium (typically normal, 30 to 40 ms). Normal His Tracing: (A) ---------- (H) ------------------------ (V)

  • |
  • +------- HV = 45 ms --------+
  • Split His Tracing: (A) ----- (H) ========= (H') --------------- (V)
  • | |
  • +-- H-H' >35 -+
  • | |
  • +------- Total HV = 85 ms -------+
  • Clinical Instability of Intra-Hisian Disease

Intra-Hisian block is notoriously unstable. Unlike AV nodal conduction delays (which are physiologically stable and responsive to autonomic modulation), intra-Hisian conduction disease is immune to autonomic rescue and exhibits unpredictable, sudden progression to complete, irreversible AV block. Pacemaker cells within the His bundle below the site of block are sparse and slow (producing unreliable escape rhythms of 30 to 40 bpm); therefore, identification of intra-Hisian block warrants urgent permanent pacemaker implantation.

Electrophysiological Localization of Atrioventricular Block

Intracardiac electrogram analysis definitively differentiates between suprahisian (AV nodal), intra-Hisian, and infra-Hisian AV conduction blocks: [Atrium (A)]

  • |
  • ===== LEVEL 1: AV NODAL BLOCK (Suprahisian) =====
  • Blocked beat shows: (A) without (H)
  • |
  • [Proximal His (H)]
  • |
  • ===== LEVEL 2: INTRA-HISIAN BLOCK =====
  • Blocked beat shows: (A)-(H) without (H')
  • |
  • [Distal His (H')]
  • |
  • ===== LEVEL 3: INFRA-HISIAN BLOCK =====
  • Blocked beat shows: (A)-(H)-(H') without (V)
  • |
  • [Ventricle (V)]
  • 1. First-Degree AV Block

Nodal (Suprahisian) : PR prolongation on the surface ECG is caused entirely by an elongated AH interval (>120 ms) . The HV interval is completely normal (35 to 55 ms). Prognosis is excellent; no pacing required in asymptomatic patients.

Infranodal : PR prolongation on the surface ECG occurs in the setting of a normal AH interval, driven entirely by an abnormally prolonged HV interval (>55 ms) . Signifies widespread, latent His-Purkinje conduction disease.

2. Second-Degree AV Block

AV Nodal Mobitz Type I (Wenckebach) :

Occurs in 75% to 80% of Mobitz I cases.

Conducted beats show progressive, beat-to-beat prolongation of the AH interval until conduction fails. The HV interval remains strictly constant on all conducted beats.

The Blocked Beat : Displays a normal low atrial deflection ( A A A ) that fails to generate a His potential —recorded as an A A A without an H H H deflection ( A blocked proximal to H A \text{ blocked proximal to } H A blocked proximal to H ).

Infranodal Mobitz Type I (His-Purkinje Wenckebach) :

Rare (<5% of cases). The AH interval remains constant, while the HV interval progressively prolongs before an H H H deflection fails to conduct to the ventricles ( A − H A-H A − H without V V V ).

Infranodal Mobitz Type II :

Represents structural disease of the His-Purkinje system.

Conducted beats display a fixed AH interval and a normal or prolonged (fixed) HV interval.

The Blocked Beat : Normal low atrial depolarization conducts through the AV node into the His bundle, producing a normal His spike, but fails to reach the ventricles—recorded as an A − H A-H A − H deflection with NO subsequent V V V deflection ( H blocked proximal to V H \text{ blocked proximal to } V H blocked proximal to V ).

Intra-Hisian Second-Degree Block :

Conducted beats display split His potentials ( H H H and H ′ H' H ′ ).

The Blocked Beat : Displays an A A A wave followed by the proximal His spike ( H H H ), but conduction blocks within the His trunk—recorded as A − H A-H A − H with absence of H ′ H' H ′ and V V V .

3. Third-Degree (Complete) AV Block

Suprahisian (AV Nodal) :

Complete dissociation between atrial deflections ( A A A ) and ventricular deflections ( V V V ).

Every ventricular escape complex is preceded by an identical His potential with a normal, constant HV interval (35 to 55 ms) . This proves that the escape pacemaker originates from the junction/His bundle below the level of block.

Characteristics: Narrow QRS (<100 ms), rate 40 to 60 bpm, stable hemodynamics, accelerates with atropine or exercise.

Intra-Hisian Complete Block :

Atrial deflections conduct to proximal His ( A − H A-H A − H ). Ventricular escape complexes originate from the distal His segment, preceded by the distal His spike ( H ′ − V H'-V H ′ − V ).

Infra-Hisian (His-Purkinje) :

Atrial deflections conduct through the AV node into the common His bundle; therefore, every A A A wave is followed by a non-conducting His spike ( A − H A-H A − H ) .

The ventricular escape complexes are broad, bizarre, and completely dissociated from the His potentials ( V V V deflections without preceding H H H spikes ).

Characteristics: Wide QRS (>120 ms), rate 20 to 40 bpm, highly unstable, unheralded ventricular standstill/syncope (Stokes-Adams attacks), fails to respond to atropine.

Master Diagnostic Table: Electrophysiological Localization of AV Block

Diagnostic Parameter AV Nodal (Suprahisian) Block Intra-Hisian Block Infra-Hisian (Infranodal) Block

Anatomical Substrate Compact atrioventricular node Common bundle of His trunk Bilateral bundle branches / trifascicular Purkinje

Surface ECG Pattern Narrow QRS; Mobitz I (Wenckebach) typical Narrow or wide QRS; Mobitz I or II Wide QRS (RBBB/LBBB); Mobitz II or complete block

Conducted Beats EGM Prolonged AH (>120 ms); normal HV (35-55 ms) Split His potentials ( H − H ′ > 30 − 40 ms H-H' > 30-40\text{ ms} H − H ′ > 30 − 40 ms ); normal H ′ − V H'-V H ′ − V Normal AH (50-120 ms); prolonged HV (>55 ms)

Blocked Beat EGM A A A without H H H (Block proximal to His) A − H A-H A − H without H ′ H' H ′ (Block within His trunk) A − H A-H A − H without V V V (Block distal to His)

Escape Pacemaker AV junctional / His bundle (40 - 60 bpm, narrow QRS) Distal His bundle ( H ′ H' H ′ , 35 - 45 bpm, narrow/variable QRS) Idioventricular / Purkinje (20 - 40 bpm, wide QRS)

Response to Atropine Improves conduction (shortens AH, decreases block) No change or worsens Worsens block (higher atrial rate stresses diseased Purkinje)

Response to Carotid Massage Worsens block (increases vagal tone, prolongs AH) No change Paradoxically improves (slower atrial rate permits Purkinje recovery)

Prognosis & Pacing Often reversible/benign; pacing only if symptomatic Unstable, high progression risk; Permanent Pacing Indicated Sinister, high sudden death risk; Class I Permanent Pacemaker Indication

Loading diagram... Electrogram Differentiation of AV Conduction Block Levels