Study guide
5.3 Catheter Shapes & Angiographic Projections
Registered Cardiovascular Invasive Specialist RCIS
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 Current RCIS Exam Facts 1.2 Eligibility Pathways & Documentation 1.3 Examination Matrix & Study Plan
2 Pre-Procedural Room Setup & Sterile Technique
2.1 Procedure & Control Room Setup 2.2 Sterile Technique & Universal Precautions 2.3 Personnel Preparation & Cath Lab Roles
3 Pre-Procedural Patient Preparation & Validation
3.1 Preparing the Patient for Invasive Procedures 3.2 Records, Labs, Allergies & Consent 3.3 Time-Out & Universal Protocol
4 Patient Monitoring & Vascular Access
4.1 Intraprocedural Vital Sign Monitoring 4.2 Arterial & Venous Access Sites 4.3 Ultrasound-Guided Access
5 Coronary Anatomy & Left Heart Catheterization
5.1 Coronary Anatomy & Dominance 5.2 Left Heart Catheterization & Coronary Angiography 5.3 Catheter Shapes & Angiographic Projections 5.4 Left Ventriculography & Aortography
6 Right Heart Catheterization & Hemodynamics
6.1 Right Heart Waveforms & Pressures 6.2 Cardiac Output: Fick & Thermodilution 6.3 Valve Area, Bernoulli & Shunt Calculations 6.4 Endomyocardial Biopsy Support
7 ECG & Intracardiac/Intravascular Imaging
7.1 12-Lead ECG in the Cath Lab 7.2 Intracardiac Echocardiography (ICE) 7.3 IVUS & OCT 7.4 Identifying Structures on Cardiac Ultrasound
8 Physiology Assessment & Radiation Safety
8.1 FFR & iFR Studies 8.2 Radiation Safety & ALARA 8.3 Radiographic Equipment Operation 8.4 Image Acquisition & Interpretation
9 Cath Lab Pharmacology
9.1 Anticipating Pharmacologic Needs 9.2 Recognizing Medication Effects & Adverse Reactions 9.3 Anticoagulation & ACT Targets
10 PCI Fundamentals
10.1 Balloon Angioplasty & Stent Platforms 10.2 Coronary Wiring, Lesion Prep & Flow Grades 10.3 Vascular Closure Devices
11 Chapter 11: Complex Coronary Intervention
11.1 CTO, Atherectomy & Alcohol Septal Ablation 11.2 Cardiac Thrombectomy (Mechanical & Aspiration) 11.3 Distal Protection Devices
12 Device Implants & Temporary Support
12.1 Pacemaker, ICD, CRT & Loop Recorders 12.2 Transvenous Temporary Pacemaker 12.3 Pericardiocentesis Support
13 Mechanical Circulatory Support
13.1 IABP & Impella 13.2 ECMO & LVAD Overview for the Cath Lab
14 Peripheral Vascular Interventions
14.1 Peripheral Interventions 14.2 Complex Peripheral Interventions 14.3 Peripheral Thrombectomy & Thrombolysis
15 Structural Heart Interventions
15.1 Nonvalvular Structural Therapies 15.2 Percutaneous Valve Interventions
16 Chapter 16: Emergency Clinical Presentations & Equipment
16.1 STEMI, Cardiogenic Shock & Pulmonary Edema 16.2 Stroke & Neurologic Emergencies in the Lab 16.3 Emergency Equipment Operation
17 Intraprocedural Complications
17.1 Coronary Interventional Complications 17.2 Peripheral & Structural Complications
18 Post-Procedural Activities
18.1 Arterial & Venous Hemostasis 18.2 Access-Site Complications 18.3 Patient Education, Reporting & Transfer of Care
5.3 Catheter Shapes & Angiographic Projections
Key Takeaways Explain This Topic AI
Judkins left (JL) and Judkins right (JR) catheters are the standard workhorse shapes for selective LCA and RCA engagement
Amplatz left (AL) and Amplatz right (AR) catheters provide alternative engagement for difficult anatomy or tall aortic roots
Multipurpose (MP) and internal mammary (IM) catheters are used for LV/aortic work and LIMA/RIMA graft angiography; pigtail catheters are standard for LV ventriculography and aortography
LAO and RAO describe C-arm rotation; cranial and caudal angulation tilts the beam cranially or caudally for branch separation
The spider view (LAO cranial) separates the LAD, LCx, and LM bifurcation and is essential for evaluating ostial and bifurcation lesions
Last updated: July 2026
Selective coronary angiography depends on two skills working together: seating the correct catheter shape at the ostium and imaging the vessel in projections that separate overlapping branches. Foreshortening—a stenosis hidden because the beam shoots down the length of the vessel—is one of the most common sources of angiographic error. The RCIS exam tests both catheter nomenclature and projection vocabulary extensively.
- Diagnostic Catheter Shapes
- Judkins Catheters (JL and JR)
Judkins Left (JL) catheters engage the left coronary artery (LCA) . Size selection depends on aortic root width and height:
- Catheter Typical Patient Engagement Notes
- JL3.5 Small aortic root, women Shorter curve; risk of deep seating in small root
- JL4 Average adult Most common default LCA catheter
- JL5 / JL6 Dilated aortic root, tall patients Larger curve needed to reach ostium
Judkins Right (JR) catheters engage the RCA :
- Catheter Typical Patient Engagement Notes
- JR4 Average adult Standard RCA catheter
- JR5 Dilated aortic root Larger curve for high RCA takeoff
JR catheters sit in the right sinus; the tip points toward the RCA ostium. Excessive counterclockwise torque can cause deep engagement and RCA dissection.
Amplatz Catheters (AL and AR)
Amplatz Left (AL) and Amplatz Right (AR) catheters use a secondary curve that hooks the ostium from the opposite sinus. They are useful when:
- Judkins catheters fail to engage
- The aortic root is dilated or aneurysmal
- Coronary takeoff is anomalous
- Graft cannulation requires a different approach angle
AL catheters engage the LCA from the contralateral (right) sinus with an upward hook. AR catheters engage the RCA similarly. Caution: Amplatz catheters can "jump" out or deeply engage when pulled back—operators must stabilize before injection.
Multipurpose (MP) Catheter
The multipurpose (MP) catheter is a versatile shape used for:
- Left ventriculography (alternative to pigtail in some labs)
- Aortic root/aortography
- Graft cannulation (SVG, occasionally native vessels)
- Coronary engagement when Judkins/Amplatz fail
The MP tip is angled and can be shaped for selective work; it is less ostium-specific than JL/JR.
Internal Mammary (IM) Catheter
The internal mammary (IM) catheter is designed to cannulate LIMA and RIMA grafts post-CABG. The gentle curve follows the subclavian–mammary path. Identifying patent mammary graft supply to the LAD is a key post-bypass angiographic goal.
Pigtail Catheter
The pigtail catheter has a looped, non-traumatic tip and is the standard choice for:
- Left ventriculography — positioned across the aortic valve in the LV
- Aortography — positioned in the ascending aorta or aortic root
The pigtail distributes contrast evenly and reduces endocardial trauma compared with straight-tip catheters.
Catheter Quick-Reference Table
- Shape Primary Use Key RCIS Exam Point
- JL LCA engagement Size matches aortic root (JL4 default)
- JR RCA engagement Avoid deep seating with excess torque
- AL / AR Difficult ostial engagement Can jump on pullback—stabilize first
- MP LV/aorta, grafts, backup engagement Versatile but less ostium-specific
- IM LIMA/RIMA graft angiography Essential in post-CABG cath
- Pigtail LV ventriculography, aortography Loop tip; crosses AV for LV study
- Angiographic Projections
Fluoroscopic projections describe C-arm position relative to the patient. Standard terminology combines:
- RAO or LAO — right or left anterior oblique rotation
- Cranial or caudal — angulation toward the head or feet
- Primary Projection Families
- Projection C-Arm Position Best For
- AP (0°) Straight AP Baseline; often foreshortens LAD
- RAO caudal RAO + caudal tilt LCA bifurcation, LM lesions ("spider-like" separation in some angulations)
- LAO cranial LAO + cranial tilt Spider view — separates LAD, LCx, LM
- LAO caudal LAO + caudal tilt Proximal LAD, mid-LAD
- RAO cranial RAO + cranial tilt RCA mid vessel, AV groove segment
- Lateral (90° LAO) True lateral SVG, some RCA lesions
- The Spider View
The spider view (approximately LAO 45–60° / cranial 15–30° , exact angles vary by lab) is the single most important LCA projection on the RCIS exam. It:
- Separates the LAD (appears to drop down) from the LCx (appears to go left)
- Opens the LM bifurcation for ostial and bifurcation stenosis assessment
- Reduces overlap of diagonal and OM branches
Without a spider-equivalent cranial LAO view, LM and proximal LAD lesions are frequently foreshortened and underestimated.
RCA Projection Essentials
- View Purpose
- LAO Opens the proximal RCA and AV groove segment
- RAO Shows PDA in long axis; evaluates posterior circulation
- Lateral Mid RCA, SVG to PDA
Always acquire at least two orthogonal views of any stenosis before reporting severity.
- Practical RCIS Tips
- Confirm catheter type and French size on the sterile field before the case starts
- Learn each physician's default projections but know the anatomic rationale so you can suggest additional views
- When the physician asks for "cranial LAO," move C-arm to LAO first, then add cranial angulation
- Document projection angles in the report when significant findings depend on a specific view
- For post-CABG cases, have IM and MP catheters available before the case begins