Study guide

6.2 Cardiac Output: Fick & Thermodilution

Registered Cardiovascular Invasive Specialist RCIS

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Exam Overview

1.1 Current RCIS Exam Facts 1.2 Eligibility Pathways & Documentation 1.3 Examination Matrix & Study Plan

2 Pre-Procedural Room Setup & Sterile Technique

2.1 Procedure & Control Room Setup 2.2 Sterile Technique & Universal Precautions 2.3 Personnel Preparation & Cath Lab Roles

3 Pre-Procedural Patient Preparation & Validation

3.1 Preparing the Patient for Invasive Procedures 3.2 Records, Labs, Allergies & Consent 3.3 Time-Out & Universal Protocol

4 Patient Monitoring & Vascular Access

4.1 Intraprocedural Vital Sign Monitoring 4.2 Arterial & Venous Access Sites 4.3 Ultrasound-Guided Access

5 Coronary Anatomy & Left Heart Catheterization

5.1 Coronary Anatomy & Dominance 5.2 Left Heart Catheterization & Coronary Angiography 5.3 Catheter Shapes & Angiographic Projections 5.4 Left Ventriculography & Aortography

6 Right Heart Catheterization & Hemodynamics

6.1 Right Heart Waveforms & Pressures 6.2 Cardiac Output: Fick & Thermodilution 6.3 Valve Area, Bernoulli & Shunt Calculations 6.4 Endomyocardial Biopsy Support

7 ECG & Intracardiac/Intravascular Imaging

7.1 12-Lead ECG in the Cath Lab 7.2 Intracardiac Echocardiography (ICE) 7.3 IVUS & OCT 7.4 Identifying Structures on Cardiac Ultrasound

8 Physiology Assessment & Radiation Safety

8.1 FFR & iFR Studies 8.2 Radiation Safety & ALARA 8.3 Radiographic Equipment Operation 8.4 Image Acquisition & Interpretation

9 Cath Lab Pharmacology

9.1 Anticipating Pharmacologic Needs 9.2 Recognizing Medication Effects & Adverse Reactions 9.3 Anticoagulation & ACT Targets

10 PCI Fundamentals

10.1 Balloon Angioplasty & Stent Platforms 10.2 Coronary Wiring, Lesion Prep & Flow Grades 10.3 Vascular Closure Devices

11 Chapter 11: Complex Coronary Intervention

11.1 CTO, Atherectomy & Alcohol Septal Ablation 11.2 Cardiac Thrombectomy (Mechanical & Aspiration) 11.3 Distal Protection Devices

12 Device Implants & Temporary Support

12.1 Pacemaker, ICD, CRT & Loop Recorders 12.2 Transvenous Temporary Pacemaker 12.3 Pericardiocentesis Support

13 Mechanical Circulatory Support

13.1 IABP & Impella 13.2 ECMO & LVAD Overview for the Cath Lab

14 Peripheral Vascular Interventions

14.1 Peripheral Interventions 14.2 Complex Peripheral Interventions 14.3 Peripheral Thrombectomy & Thrombolysis

15 Structural Heart Interventions

15.1 Nonvalvular Structural Therapies 15.2 Percutaneous Valve Interventions

16 Chapter 16: Emergency Clinical Presentations & Equipment

16.1 STEMI, Cardiogenic Shock & Pulmonary Edema 16.2 Stroke & Neurologic Emergencies in the Lab 16.3 Emergency Equipment Operation

17 Intraprocedural Complications

17.1 Coronary Interventional Complications 17.2 Peripheral & Structural Complications

18 Post-Procedural Activities

18.1 Arterial & Venous Hemostasis 18.2 Access-Site Complications 18.3 Patient Education, Reporting & Transfer of Care

6.2 Cardiac Output: Fick & Thermodilution

Key Takeaways Explain This Topic AI

Fick cardiac output: CO (L/min) = VO₂ (mL/min) ÷ [arterial O₂ content − mixed venous O₂ content], using vol% difference × 10 or the Hgb-based content formula

Worked example: VO₂ 250 mL/min, aortic O₂ 21 vol%, PA O₂ 16 vol%, BSA 1.8 m² → CO ≈ 5.0 L/min and CI ≈ 2.8 L/min/m²

Thermodilution CO injects cold saline into the RA and integrates the downstream temperature change — fast but invalidated by severe TR, shunts, and low-output states

Fick requires steady-state oxygen consumption and accurate mixed venous sampling from true PA blood — not RA blood when significant shunt or TR exists

Normal CO is 4–8 L/min; normal cardiac index (CO ÷ BSA) is 2.5–4.0 L/min/m²; CI below 2.2 with elevated PCWP suggests cardiogenic shock physiology

Last updated: July 2026

6.2 Cardiac Output: Fick & Thermodilution

Quick Answer: Cardiac output (CO) quantifies how much blood the heart pumps per minute. The two methods RCIS candidates must master are the Fick principle (oxygen consumption divided by arteriovenous oxygen difference) and thermodilution (cold saline indicator dilution via PA catheter). Each has distinct assumptions and failure modes — knowing when to trust one method over the other is a high-yield RCIS exam topic.

Cardiac output drives nearly every hemodynamic calculation downstream: cardiac index, pulmonary vascular resistance (PVR), systemic vascular resistance (SVR), valve area (Gorlin), and shunt ratio (Qp:Qs). Accurate CO measurement separates meaningful hemodynamics from artifact.

Normal Values

  • Parameter Normal Range Formula
  • Cardiac output (CO) 4–8 L/min —
  • Cardiac index (CI) 2.5–4.0 L/min/m² CI = CO ÷ BSA
  • Stroke volume (SV) 60–100 mL/beat SV = CO ÷ HR

Body surface area (BSA) is typically calculated from height and weight (Mosteller formula on many exam items). A patient with CO 5.0 L/min and BSA 1.8 m² has CI = 2.78 L/min/m² — within normal limits.

The Fick Principle

The Fick method applies conservation of mass: in steady state, oxygen consumed by the body equals oxygen delivered by blood flow minus oxygen returned in mixed venous blood.

Vol% Method (Common on RCIS Exams)

When oxygen contents are expressed as volume percent (vol%):

CO (L/min) = VO₂ (mL/min) ÷ [(Ao vol% − PA vol%) × 10]

Where:

  • VO₂ = oxygen consumption (mL/min), often assumed 250 mL/min for resting adults or measured via metabolic cart
  • Ao vol% = arterial oxygen content as volume percent (≈20–21 vol% on room air)
  • PA vol% = mixed venous oxygen content from true pulmonary artery blood (≈14–17 vol%)

The factor ×10 converts vol% difference to the proper denominator units.

Worked Example (Exam-Style)

Given:

  • VO₂ = 250 mL/min (assumed resting consumption)
  • Aortic O₂ content = 21 vol%
  • PA (mixed venous) O₂ content = 16 vol%
  • BSA = 1.8 m²
  • Step 1 — Calculate arteriovenous difference: 21 vol% − 16 vol% = 5 vol%
  • Step 2 — Calculate CO: CO = 250 ÷ (5 × 10) = 250 ÷ 50 = 5.0 L/min
  • Step 3 — Calculate cardiac index: CI = 5.0 ÷ 1.8 = 2.78 L/min/m² (normal)

This matches the canonical RCIS sample calculation: VO₂ 250, Ao 21 vol%, PA 16 vol%, BSA 1.8 → CO ≈ 5 L/min .

Hemoglobin-Based Fick (Alternative Form)

When saturations and hemoglobin are given instead of vol%:

CO = VO₂ ÷ [1.36 × Hgb × (SaO₂ − SvO₂)]

Where SaO₂ and SvO₂ are expressed as decimals (0.95 and 0.65, not 95 and 65). The constant 1.36 mL O₂/g Hgb is the Hüfner number.

Example: VO₂ 250, Hgb 12 g/dL, SaO₂ 95%, SvO₂ 65%:

  • Difference = 0.30
  • Denominator = 1.36 × 12 × 0.30 = 4.896
  • CO = 250 ÷ 4.896 ≈ 5.1 L/min

Both methods converge near 5 L/min — exam items may use either format.

Fick Assumptions and When Fick Fails

Assumption Why It Matters

Steady-state VO₂ Acute changes in work of breathing, fever, or sedation alter VO₂ and invalidate assumed 250 mL/min

True mixed venous sample PA blood is mixed venous; RA blood is NOT mixed venous if shunt or significant TR causes streaming

No left-to-right shunt at sampling site Shunt blood with higher O₂ content dilutes the true C(a-v)O₂ difference, overestimating CO

Accurate arterial sample Must be true systemic arterial (aortic or high-quality radial/femoral)

When to prefer Fick: Low cardiac output states, severe tricuspid regurgitation (thermodilution recirculation), significant intracardiac shunts, and when thermodilution and Fick disagree — Fick with measured VO₂ is often the reference standard.

Thermodilution Method

Thermodilution uses a PA catheter thermistor. The RCIS or operator injects a known volume of cold saline (typically 10 mL at 0°C) into the RA port. The downstream temperature change at the PA thermistor is integrated over time; cardiac output is inversely proportional to the area under the temperature-time curve.

Conceptual formula: CO ∝ (Volume of injectate × Temperature difference) ÷ ∫ΔT dt

Computerized systems apply correction constants (K1, K2) for catheter and injectate characteristics. RCIS candidates rarely calculate manually — but must know technique and limitations .

  • Proper Thermodilution Technique
  • Confirm PA catheter position (PA waveform, not wedge)
  • Inject briskly at end-expiration (reduces respiratory variation)
  • Use consistent injectate volume and temperature
  • Discard highest and lowest of 3–5 injections; average the remainder
  • Document TR severity before trusting results
  • When Thermodilution Fails
  • Condition Mechanism Result
  • Severe tricuspid regurgitation Indicator recirculates to RA before full washout Falsely high CO
  • Intracardiac shunt Indicator lost across shunt; non-linear dilution Unreliable
  • Low CO (<2.5 L/min) Small temperature change → poor signal-to-noise Underestimates or fails
  • Poor injection technique Slow injection, wrong volume, intracardiac placement Erratic curves
  • Cardiac arrhythmia Variable cycle length between injections Inconsistent readings

RCIS exam tip: Thermodilution is inaccurate in severe TR and shunts — use Fick instead. This phrase appears repeatedly on RCIS items.

Comparing Methods: Decision Table

  • Scenario Preferred Method Reason
  • Routine PA catheter CO, no TR/shunt Thermodilution Fast, repeatable
  • Severe TR Fick Recirculation artifact
  • Atrial septal defect (left-to-right) Fick with oximetry Shunt invalidates indicator dilution
  • Low output / cardiogenic shock Fick (measured VO₂) Thermodilution loses accuracy
  • No PA catheter available Fick Only invasive option with A-line + oximetry
  • Derived Calculations Using CO

Once CO is established, the RCIS should recognize downstream formulas:

PVR (Wood units) = (mean PAP − mean PCWP) ÷ CO

Example: mean PAP 30, PCWP 14, CO 4.5 L/min → PVR = 16 ÷ 4.5 = 3.6 Wood units (normal <2–3 WU at rest; multiply by 80 for dynes·sec/cm⁵).

SVR = (mean MAP − mean RA) ÷ CO × 80 (for dynes·sec/cm⁵)

Normal SVR ≈ 800–1200 dynes·sec/cm⁵.

Clinical Scenario: Conflicting CO Values

Thermodilution reports CO 7.5 L/min in a patient with known severe TR and RA enlargement on echo. Fick calculation (VO₂ 250, Ao 21 vol%, PA 16 vol%) yields CO 5.0 L/min. Trust Fick — thermodilution is falsely elevated by TR recirculation. Document both values and communicate the discrepancy to the operator.

  • RCIS Responsibilities During CO Determination
  • Prepare and label syringes for thermodilution injectate (verify volume and temperature per protocol)
  • Time injections at end-expiration when requested
  • Record oximetry samples in correct order (SVC, RA, RV, PA, Ao) for Fick and shunt studies
  • Never inject air — catastrophic embolism risk
  • Chart CO, CI, and method used; note TR, shunt, or arrhythmia that may affect accuracy