Study guide

18.2 Strain Interpretation, Global Longitudinal Strain, and Disease Patterns

CCI Registered Cardiac Sonographer RCS

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: RCS Orientation and Clinical Context

1.1 RCS Identity, Exam Format, Application, and Retesting 1.2 Clinical History, Symptoms, Indications, and Risk Factors 1.3 Prior Studies, Serial Change, and Cross-Modality Context

2 Chapter 2: Orders, Safety, and Patient Preparation

2.1 Order Verification, Scope, and Protocol Selection 2.2 Sonographer Ergonomics and Staff Safety 2.3 Patient Preparation, Positioning, Consent, Infection Control, and Aftercare

3 Chapter 3: Reporting and 2-D TTE Foundations

3.1 Structured Findings, Significant Results, and Escalation 3.2 Standard 2-D TTE Windows, Views, and Acquisition Sequence 3.3 2-D Measurements, Foreshortening, Image Quality, and QA

4 Chapter 4: M-Mode and Doppler Acquisition

4.1 M-Mode Alignment, Timing, Measurements, and Pitfalls 4.2 Color Doppler Acquisition, Scale, Gain, and Jet Display 4.3 PW and CW Spectral Doppler Acquisition

5 Chapter 5: Advanced Doppler and Contrast

5.1 Tissue Doppler and Hemodynamic Sample Placement 5.2 Ultrasound-Enhancing Agents and LV Opacification 5.3 Agitated-Saline Studies and Intracardiac Shunts

6 Chapter 6: Stress Echocardiography

6.1 Exercise Stress Echo Protocols and Peak Imaging 6.2 Pharmacologic Stress Echo, Dobutamine, and Safety 6.3 Non-Ischemic Stress Echo and Hemodynamic Provocation

7 Chapter 7: TEE, Strain, and 3-D TEE

7.1 Assisting TEE: Preparation, Probe Safety, Views, and Complications 7.2 Strain Acquisition, Tracking Quality, and Reproducibility 7.3 3-D TEE Acquisition, Cropping, Orientation, and Artifacts

8 Chapter 8: 3-D TTE and the Aortic Valve

8.1 3-D TTE Full-Volume Acquisition and Quantitation 8.2 Aortic-Valve Anatomy, Morphology, and Function 8.3 Aortic Stenosis: Velocities, Gradients, Valve Area, and Flow States

9 Chapter 9: Aortic Regurgitation and Mitral Structure

9.1 Aortic Regurgitation Mechanisms and Integrated Severity 9.2 Mitral-Valve Anatomy, Motion, and Mechanisms 9.3 Mitral Stenosis: Planimetry, Gradients, Pressure Half-Time, and Suitability

10 Chapter 10: Mitral and Tricuspid Valve Findings

10.1 Mitral Regurgitation Mechanism, Quantitation, and Severity Integration 10.2 Tricuspid-Valve Anatomy, Structure, and Function 10.3 Tricuspid Stenosis Assessment

11 Chapter 11: Right-Sided Valve Disease

11.1 Tricuspid Regurgitation Mechanism and Severity 11.2 Pulmonic-Valve Anatomy, Structure, and Function 11.3 Pulmonic Stenosis Assessment

12 Chapter 12: Pulmonic Regurgitation and Prosthetic Valves

12.1 Pulmonic Regurgitation Mechanism and Severity 12.2 Normal Mechanical and Bioprosthetic Valve Assessment 12.3 Prosthetic Obstruction, Regurgitation, Thrombosis, and Patient–Prosthesis Mismatch

13 Chapter 13: Endocarditis and Cardiac Chambers

13.1 Valvular Endocarditis, Vegetations, Abscess, and Complications 13.2 LV and LA Size, Geometry, Volumes, Mass, and Function 13.3 RV and RA Size, Pressure, Volume, and Function

14 Chapter 14: Cardiomyopathy Phenotypes and Diastology

14.1 Dilated and Hypertrophic Cardiomyopathies, SAM, and LVOT Obstruction 14.2 Restrictive, Arrhythmogenic, and Stress Cardiomyopathies 14.3 Diastolic Function, Filling Pressure, Grading, and Pitfalls

15 Chapter 15: Systolic Function and Ischemia

15.1 LV Systolic Function, Simpson EF, Regional Motion, and Output 15.2 RV Systolic Function: TAPSE, S-prime, FAC, and Coupling 15.3 Ischemic Heart Disease, Coronary Territories, Stress Response, and Complications

16 Chapter 16: Pericardium and Great Vessels

16.1 Pericardial Effusion, Tamponade, Constriction, and Doppler Physiology 16.2 Great Vessels, Venous Return, and Pulmonary Artery Assessment 16.3 Aortic Root, Aneurysm, Dissection, and Coarctation

17 Chapter 17: Pulmonary Pressure, Masses, and Congenital Recognition

17.1 Pulmonary Hypertension, RAP/PASP Estimation, and RV Consequences 17.2 Cardiac Masses, Thrombus, Tumor, Vegetation, and Mimics 17.3 Adult Recognition of ASD, VSD, PFO, PDA, and Congenital Clues

18 Chapter 18: Devices, Strain, and Hemodynamics

18.1 ICDs, Pacemakers, Occluders, Closure Devices, and Mechanical Support 18.2 Strain Interpretation, Global Longitudinal Strain, and Disease Patterns 18.3 Cardiac Hemodynamics, Bernoulli, Continuity, Stroke Volume, and Shunts

19 Chapter 19: Infiltrative Disease and Physics Foundations

19.1 Amyloid, Sarcoid, and Other Infiltrative Disease Patterns 19.2 Ultrasound Wave Properties, Propagation, Frequency, and Wavelength 19.3 Artifact Recognition: Reverberation, Shadowing, Mirror, Refraction, and Aliasing

20 Chapter 20: Resolution and Doppler Optimization

20.1 Axial/Lateral Resolution, Frame Rate, Depth, Focus, and Trade-Offs 20.2 Spectral Doppler Optimization, Nyquist, Filters, Gain, and Angle 20.3 Color Doppler Optimization, Scale, Priority, Variance, and Gain

21 Chapter 21: 2-D, 3-D, and Contrast Optimization

21.1 2-D Optimization: Frequency, Gain, TGC, Harmonics, Depth, and Focus 21.2 3-D Optimization: Volume Rate, Stitching, Cropping, and Display 21.3 Contrast Optimization: Mechanical Index, Destruction, Replenishment, and Artifacts

18.2 Strain Interpretation, Global Longitudinal Strain, and Disease Patterns

Key Takeaways Explain This Topic AI

Strain is fractional length change: longitudinal systolic shortening is conventionally negative, so a value moving from −20% to −16% is less negative and represents worse shortening.

Acquire nonforeshortened apical views with stable ECG and adequate temporal resolution, then visually verify full-wall ROI placement and tracking rather than accepting an automated bull's-eye.

Current adult LV myocardial GLS is generally normal when more negative than −18%, borderline from −16% to −18%, and abnormal when less negative than −16%, subject to loading, age, software, and patient context.

Use GLS most powerfully for same-vendor serial follow-up and treat regional patterns such as apical sparing, coronary-territory impairment, or stress distributions as supportive clues rather than etiologic proof.

Last updated: July 2026

Keep the sign and timing straight

CCI task D13 is to evaluate strain imaging. Strain is dimensionless fractional deformation: strain (%) = (L − L₀) / L₀ × 100 . If a myocardial fiber shortens from 10 cm to 8 cm, longitudinal strain is (8 − 10)/10 × 100 = −20% . More negative LV longitudinal strain means greater systolic shortening; −12% is worse, not better, than −20%. Current ASE guidance advises retaining the negative sign for GLS and segmental values. If a system displays positive magnitudes, call the metric global longitudinal shortening and state the convention rather than mixing signed and absolute numbers.

End diastole and zero strain should correspond to mitral-valve closure, and default GLS is end-systolic strain at aortic-valve closure. Verify automated event timing on 2-D valve motion or spectral Doppler, especially with conduction delay, pacing, ectopy, or marked preejection time. Peak strain after aortic closure is postsystolic shortening, not ordinary end-systolic function. Curve shape and timing can be more informative than the lowest number in regional disease.

Acquire and validate before reading the bull's-eye

Acquire nonforeshortened apical four-, two-, and long-axis views with the true apex and full myocardium visible, a stable ECG, similar heart rate, and frame rate appropriate to heart rate. Narrow sector width and depth while retaining the complete LV. Avoid immediate postectopic beats; in AF, average representative cycles or use the third of three cycles with similar lengths. Record BP and clinical loading conditions because preload and afterload change strain even when contractility does not.

Trace the endocardium and adjust the region of interest to include full wall thickness without pericardium. An ROI that is too broad lowers magnitude; a subendocardial-only ROI can exaggerate it. Play every tracking overlay. Reject segments that leave myocardium, track papillary muscle, jump across scar, or follow reverberation. If more than three LV segments are uninterpretable, do not report GLS. Foreshortening can falsely increase apical strain and manufacture an apical-sparing map. Report image quality, analysis software/version, layer convention, views, excluded segments, and GLS with its sign.

  • Quality checkpoint Error prevented
  • True apex in all three views False apical hyperfunction and wrong segment length
  • Full-wall ROI, no pericardium Layer-dependent over- or underestimation
  • Valve-closure timing verified Confusing end-systolic with postsystolic strain
  • Stable rhythm, HR, BP, and loading Calling physiologic variation disease progression
  • Same vendor and software version Mistaking platform shift for biologic change
  • Interpret global values and serial change

For adult LV myocardial GLS, current consensus categorizes more negative than −18% as normal, −16% to −18% as borderline, and less negative than −16% as abnormal. These are contextual ranges, not universal biological walls: age, sex, blood pressure, loading, body size, acquisition, myocardial versus endocardial analysis, and software matter. GLS complements EF because longitudinal dysfunction may appear while EF is preserved, but a reduced value is not an etiology. Three-dimensional strain and routine radial strain remain insufficiently standardized for routine clinical decisions.

Same-patient follow-up is especially useful. A relative GLS magnitude reduction of about 10%–15% is likely significant when technique and load are comparable. Calculate relative worsening = (|baseline GLS| − |follow-up GLS|) / |baseline GLS| × 100 . A change from −20% to −17% is a 3-percentage-point change but a 15% relative reduction in magnitude. First review tracking, vendor/version, BP, rhythm, and volume status; then integrate EF, symptoms, biomarkers, treatment exposure, and other imaging. This signal can support possible treatment-related dysfunction but does not alone prove cardiotoxicity.

Do not pool chamber-specific strain metrics. Acquire RV free-wall strain from an RV-focused apical four-chamber view at about 60–90 frames/s and label whether septum is excluded; current lower limits are approximately −20% in men and −21% in women. LA reservoir strain uses dedicated software, nonforeshortened apical views, and R-R gating. Current ASE consensus describes approximately 30%–60% as normal, 23% as the lower limit of normal, and 23%–30% as borderline abnormal rather than simply normal. These values remain load, rhythm, view, and software dependent. A dedicated chamber ROI is preferable to casually adapting LV software, and serial comparisons must preserve gating and chamber definition.

Use disease patterns as clues

Ischemia or infarction may reduce strain in a coronary distribution, with early systolic lengthening and postsystolic shortening; however, postsystolic shortening is sensitive but nonspecific and also occurs with scar, hypertrophy, conduction delay, and loading change. Segmental strain is less reproducible than GLS, so confirm the pattern with wall motion, ECG, perfusion or coronary data, and serial findings.

In increased wall thickness, impaired strain in hypertrophied septal regions may accompany classic HCM, while apical HCM reduces apical strain. Relative apical sparing with worse basal and mid strain raises the possibility of cardiac amyloidosis, particularly when apical mean strain is more than twice the mean of the rest of the LV, but similar patterns can occur with aortic stenosis, renal disease, hypertensive remodeling, or technical foreshortening. Seek morphology and the appropriate CMR, laboratory, or nuclear pathway rather than declaring amyloid from the map.

Stress cardiomyopathy commonly shows mid-apical, midventricular, basal, or focal impairment extending beyond one coronary territory and should recover on serial imaging; acute coronary syndrome and myocarditis remain alternatives. Hypertension often produces a basal-to-apical gradient, and HFrEF often has diffuse reduction. RV free-wall longitudinal strain requires an RV-focused view and dedicated ROI; do not compare it with RV four-chamber strain that includes septum. Across all diseases, report a pattern as supportive, integrate chamber function and load, and preserve diagnostic uncertainty.