Study guide
10.2 Tricuspid-Valve Anatomy, Structure, and Function
CCI Registered Cardiac Sonographer RCS
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: RCS Orientation and Clinical Context
1.1 RCS Identity, Exam Format, Application, and Retesting 1.2 Clinical History, Symptoms, Indications, and Risk Factors 1.3 Prior Studies, Serial Change, and Cross-Modality Context
2 Chapter 2: Orders, Safety, and Patient Preparation
2.1 Order Verification, Scope, and Protocol Selection 2.2 Sonographer Ergonomics and Staff Safety 2.3 Patient Preparation, Positioning, Consent, Infection Control, and Aftercare
3 Chapter 3: Reporting and 2-D TTE Foundations
3.1 Structured Findings, Significant Results, and Escalation 3.2 Standard 2-D TTE Windows, Views, and Acquisition Sequence 3.3 2-D Measurements, Foreshortening, Image Quality, and QA
4 Chapter 4: M-Mode and Doppler Acquisition
4.1 M-Mode Alignment, Timing, Measurements, and Pitfalls 4.2 Color Doppler Acquisition, Scale, Gain, and Jet Display 4.3 PW and CW Spectral Doppler Acquisition
5 Chapter 5: Advanced Doppler and Contrast
5.1 Tissue Doppler and Hemodynamic Sample Placement 5.2 Ultrasound-Enhancing Agents and LV Opacification 5.3 Agitated-Saline Studies and Intracardiac Shunts
6 Chapter 6: Stress Echocardiography
6.1 Exercise Stress Echo Protocols and Peak Imaging 6.2 Pharmacologic Stress Echo, Dobutamine, and Safety 6.3 Non-Ischemic Stress Echo and Hemodynamic Provocation
7 Chapter 7: TEE, Strain, and 3-D TEE
7.1 Assisting TEE: Preparation, Probe Safety, Views, and Complications 7.2 Strain Acquisition, Tracking Quality, and Reproducibility 7.3 3-D TEE Acquisition, Cropping, Orientation, and Artifacts
8 Chapter 8: 3-D TTE and the Aortic Valve
8.1 3-D TTE Full-Volume Acquisition and Quantitation 8.2 Aortic-Valve Anatomy, Morphology, and Function 8.3 Aortic Stenosis: Velocities, Gradients, Valve Area, and Flow States
9 Chapter 9: Aortic Regurgitation and Mitral Structure
9.1 Aortic Regurgitation Mechanisms and Integrated Severity 9.2 Mitral-Valve Anatomy, Motion, and Mechanisms 9.3 Mitral Stenosis: Planimetry, Gradients, Pressure Half-Time, and Suitability
10 Chapter 10: Mitral and Tricuspid Valve Findings
10.1 Mitral Regurgitation Mechanism, Quantitation, and Severity Integration 10.2 Tricuspid-Valve Anatomy, Structure, and Function 10.3 Tricuspid Stenosis Assessment
11 Chapter 11: Right-Sided Valve Disease
11.1 Tricuspid Regurgitation Mechanism and Severity 11.2 Pulmonic-Valve Anatomy, Structure, and Function 11.3 Pulmonic Stenosis Assessment
12 Chapter 12: Pulmonic Regurgitation and Prosthetic Valves
12.1 Pulmonic Regurgitation Mechanism and Severity 12.2 Normal Mechanical and Bioprosthetic Valve Assessment 12.3 Prosthetic Obstruction, Regurgitation, Thrombosis, and Patient–Prosthesis Mismatch
13 Chapter 13: Endocarditis and Cardiac Chambers
13.1 Valvular Endocarditis, Vegetations, Abscess, and Complications 13.2 LV and LA Size, Geometry, Volumes, Mass, and Function 13.3 RV and RA Size, Pressure, Volume, and Function
14 Chapter 14: Cardiomyopathy Phenotypes and Diastology
14.1 Dilated and Hypertrophic Cardiomyopathies, SAM, and LVOT Obstruction 14.2 Restrictive, Arrhythmogenic, and Stress Cardiomyopathies 14.3 Diastolic Function, Filling Pressure, Grading, and Pitfalls
15 Chapter 15: Systolic Function and Ischemia
15.1 LV Systolic Function, Simpson EF, Regional Motion, and Output 15.2 RV Systolic Function: TAPSE, S-prime, FAC, and Coupling 15.3 Ischemic Heart Disease, Coronary Territories, Stress Response, and Complications
16 Chapter 16: Pericardium and Great Vessels
16.1 Pericardial Effusion, Tamponade, Constriction, and Doppler Physiology 16.2 Great Vessels, Venous Return, and Pulmonary Artery Assessment 16.3 Aortic Root, Aneurysm, Dissection, and Coarctation
17 Chapter 17: Pulmonary Pressure, Masses, and Congenital Recognition
17.1 Pulmonary Hypertension, RAP/PASP Estimation, and RV Consequences 17.2 Cardiac Masses, Thrombus, Tumor, Vegetation, and Mimics 17.3 Adult Recognition of ASD, VSD, PFO, PDA, and Congenital Clues
18 Chapter 18: Devices, Strain, and Hemodynamics
18.1 ICDs, Pacemakers, Occluders, Closure Devices, and Mechanical Support 18.2 Strain Interpretation, Global Longitudinal Strain, and Disease Patterns 18.3 Cardiac Hemodynamics, Bernoulli, Continuity, Stroke Volume, and Shunts
19 Chapter 19: Infiltrative Disease and Physics Foundations
19.1 Amyloid, Sarcoid, and Other Infiltrative Disease Patterns 19.2 Ultrasound Wave Properties, Propagation, Frequency, and Wavelength 19.3 Artifact Recognition: Reverberation, Shadowing, Mirror, Refraction, and Aliasing
20 Chapter 20: Resolution and Doppler Optimization
20.1 Axial/Lateral Resolution, Frame Rate, Depth, Focus, and Trade-Offs 20.2 Spectral Doppler Optimization, Nyquist, Filters, Gain, and Angle 20.3 Color Doppler Optimization, Scale, Priority, Variance, and Gain
21 Chapter 21: 2-D, 3-D, and Contrast Optimization
21.1 2-D Optimization: Frequency, Gain, TGC, Harmonics, Depth, and Focus 21.2 3-D Optimization: Volume Rate, Stitching, Cropping, and Display 21.3 Contrast Optimization: Mechanical Index, Destruction, Replenishment, and Artifacts
10.2 Tricuspid-Valve Anatomy, Structure, and Function
Key Takeaways Explain This Topic AI
Assess the tricuspid valve as an apparatus that includes the dynamic nonplanar annulus, leaflets, chordae, papillary muscles, RA, RV, septum, and caval inflow—not as three isolated leaflet echoes.
Leaflet number and appearance vary, and most 2-D views do not show all leaflets simultaneously; identify anatomy with systematic sweeps, landmarks, complementary views, and 3-D imaging when needed.
Differentiate primary leaflet or chordal disease from ventricular functional, atrial functional, and cardiac-device-related mechanisms by demonstrating the cause of failed coaptation.
Describe annular dilation, tethering, coaptation gap, chamber remodeling, RV function, pulmonary pressure, and device interaction because these findings explain valve function and guide severity interpretation.
Last updated: July 2026
Treat the valve and right heart as one functional unit
CCI task C7 requires assessment of tricuspid-valve structure and function. The apparatus includes a large nonplanar annulus, thin leaflets, chordae, papillary muscles, RA, RV, interventricular septum, and adjacent venae cavae and coronary sinus. The traditional leaflet names are anterior, septal, and posterior, but leaflet number, scalloping, and commissural pattern vary. The septal leaflet attaches near the septum; the anterior leaflet is usually the largest and most mobile; the posterior region is often more variable. A single 2-D slice rarely demonstrates all leaflets, so do not give a confident leaflet name merely because two lines appear in an apical image.
The annulus changes size and shape during the cardiac cycle. It contains more fibrous support near the septum and is more muscular along the free wall. Normal systolic annular contraction and leaflet coaptation limit regurgitation; RA or RV remodeling can flatten and enlarge the annulus, pull papillary muscles outward, increase tethering, and create a coaptation gap. Valve function therefore reflects both tissue integrity and the geometry generated by the chambers.
Build a reproducible multiplanar survey
Begin with the RV-focused apical four-chamber view rather than accepting a foreshortened standard view. Center the RV, show the apex and maximal basal diameter, and sweep or rotate through the valve. Parasternal RV-inflow imaging displays leaflet motion, chordae, inflow, and the RV free wall; parasternal short-axis imaging near the aortic valve provides a complementary commissural cut. Subcostal four-chamber and short-axis sweeps are valuable when apical alignment is poor and can show the septum, RA, IVC, and device course. Use zoom carefully: a close view improves tissue detail but may remove the landmarks needed for orientation.
Imaging target Required observation Frequent trap
Leaflets Number seen, thickness, mobility, coaptation, prolapse/flail, restriction Assuming two visible edges identify all three leaflets
- Annulus Size, shape, systolic contraction, free-wall dilation Oblique measurement or wrong cardiac phase
- Subvalvular apparatus Chordal integrity and papillary displacement Mistaking chord or reverberation for a mass
RA and RV Size, RV systolic function, pressure/volume-loading pattern Grading the valve without chamber mechanism
Device lead Course and actual leaflet or subvalvular interaction Calling every TR jet in a device patient lead caused
Flow Diastolic opening/inflow and systolic regurgitation Using color appearance as the only functional test
Record color Doppler in more than one plane to locate systolic regurgitation and diastolic acceleration. Place PW Doppler at the leaflet tips when tricuspid inflow is needed, use low velocity scales and filters, and account for respiration and rhythm. CW across a regurgitant jet can support hemodynamic assessment, but the dedicated grading of TR belongs to an integrated protocol. Structural assessment should already describe the orifice, coaptation, jet origin, RA/RV response, IVC, hepatic-vein flow when obtained, RV systolic function, and estimated pulmonary pressure limitations.
Three-dimensional imaging is particularly useful for an en-face view of the annulus, commissural regions, coaptation defect, and relationship of a transvenous lead to leaflet tissue. Orient the dataset consistently and inspect multiplanar source images; rendered color can hide dropout. Thin leaflets, low volume rate, stitching, gain-dependent holes, acoustic shadow, and near-field artifact still limit 3-D certainty. A suspected lesion must persist in source planes and through appropriate frames.
Separate primary, functional, and device-related mechanisms
Primary tricuspid disease directly changes leaflet or chordal tissue. Examples include infective endocarditis, carcinoid retraction, rheumatic thickening and commissural fusion, prolapse or flail, trauma, and congenital disease such as Ebstein anomaly. Describe the visible abnormality and its motion rather than using regurgitation severity as proof of mechanism. A mobile mass, destroyed leaflet, acute flail segment, or suspected infection requires prompt communication through the laboratory pathway.
In ventricular functional TR , pulmonary hypertension, left-heart disease, RV disease, or RV volume overload produces RV and annular dilation with papillary displacement and systolic tethering. The leaflets may be structurally normal but fail to meet. In atrial functional TR , marked RA and annular dilation—often with long-standing atrial fibrillation—dominates, with comparatively less RV tethering early in the process. These categories can overlap; report observed annular size, tethering, coaptation gap, chamber geometry, pressure context, and RV function instead of forcing a label when mixed remodeling is present.
A cardiac implantable electronic-device lead may impinge on a leaflet, become entangled in chordae, adhere to tissue, perforate a leaflet, or indirectly contribute through remodeling. Its mere presence does not prove causation. Demonstrate temporal and spatial interaction in multiple 2-D planes or 3-D multiplanar reconstruction: does the lead prevent systolic closure, pin a leaflet, cross a commissure without restriction, or simply lie near the jet? Compare studies before and after implantation when available.
Ebstein anomaly illustrates why landmarks matter: apical displacement of the septal leaflet relative to the mitral insertion, atrialization of part of the RV, abnormal anterior-leaflet morphology, and right-heart dilation form a constellation. Do not diagnose it from apparent offset in a foreshortened image. Similarly, distinguish true thickening or a mass from reverberation by changing view, frequency, gain, and transducer position.
A useful final acquisition record states which views and leaflets were confidently demonstrated; annular size and contraction; leaflet thickness, mobility, and coaptation; chordal or papillary abnormality; mechanism of dysfunction; RA/RV size and RV function; pressure and volume-loading context; device relationship; and image limitations. This structural map makes later stenosis or regurgitation measurements interpretable.