1 Chapter 1: RCS Orientation and Clinical Context

1.1 RCS Identity, Exam Format, Application, and Retesting 1.2 Clinical History, Symptoms, Indications, and Risk Factors 1.3 Prior Studies, Serial Change, and Cross-Modality Context

2 Chapter 2: Orders, Safety, and Patient Preparation

2.1 Order Verification, Scope, and Protocol Selection 2.2 Sonographer Ergonomics and Staff Safety 2.3 Patient Preparation, Positioning, Consent, Infection Control, and Aftercare

3 Chapter 3: Reporting and 2-D TTE Foundations

3.1 Structured Findings, Significant Results, and Escalation 3.2 Standard 2-D TTE Windows, Views, and Acquisition Sequence 3.3 2-D Measurements, Foreshortening, Image Quality, and QA

4 Chapter 4: M-Mode and Doppler Acquisition

4.1 M-Mode Alignment, Timing, Measurements, and Pitfalls 4.2 Color Doppler Acquisition, Scale, Gain, and Jet Display 4.3 PW and CW Spectral Doppler Acquisition

5 Chapter 5: Advanced Doppler and Contrast

5.1 Tissue Doppler and Hemodynamic Sample Placement 5.2 Ultrasound-Enhancing Agents and LV Opacification 5.3 Agitated-Saline Studies and Intracardiac Shunts

6 Chapter 6: Stress Echocardiography

6.1 Exercise Stress Echo Protocols and Peak Imaging 6.2 Pharmacologic Stress Echo, Dobutamine, and Safety 6.3 Non-Ischemic Stress Echo and Hemodynamic Provocation

7 Chapter 7: TEE, Strain, and 3-D TEE

7.1 Assisting TEE: Preparation, Probe Safety, Views, and Complications 7.2 Strain Acquisition, Tracking Quality, and Reproducibility 7.3 3-D TEE Acquisition, Cropping, Orientation, and Artifacts

8 Chapter 8: 3-D TTE and the Aortic Valve

8.1 3-D TTE Full-Volume Acquisition and Quantitation 8.2 Aortic-Valve Anatomy, Morphology, and Function 8.3 Aortic Stenosis: Velocities, Gradients, Valve Area, and Flow States

9 Chapter 9: Aortic Regurgitation and Mitral Structure

9.1 Aortic Regurgitation Mechanisms and Integrated Severity 9.2 Mitral-Valve Anatomy, Motion, and Mechanisms 9.3 Mitral Stenosis: Planimetry, Gradients, Pressure Half-Time, and Suitability

10 Chapter 10: Mitral and Tricuspid Valve Findings

10.1 Mitral Regurgitation Mechanism, Quantitation, and Severity Integration 10.2 Tricuspid-Valve Anatomy, Structure, and Function 10.3 Tricuspid Stenosis Assessment

11 Chapter 11: Right-Sided Valve Disease

11.1 Tricuspid Regurgitation Mechanism and Severity 11.2 Pulmonic-Valve Anatomy, Structure, and Function 11.3 Pulmonic Stenosis Assessment

12 Chapter 12: Pulmonic Regurgitation and Prosthetic Valves

12.1 Pulmonic Regurgitation Mechanism and Severity 12.2 Normal Mechanical and Bioprosthetic Valve Assessment 12.3 Prosthetic Obstruction, Regurgitation, Thrombosis, and Patient–Prosthesis Mismatch

13 Chapter 13: Endocarditis and Cardiac Chambers

13.1 Valvular Endocarditis, Vegetations, Abscess, and Complications 13.2 LV and LA Size, Geometry, Volumes, Mass, and Function 13.3 RV and RA Size, Pressure, Volume, and Function

14 Chapter 14: Cardiomyopathy Phenotypes and Diastology

14.1 Dilated and Hypertrophic Cardiomyopathies, SAM, and LVOT Obstruction 14.2 Restrictive, Arrhythmogenic, and Stress Cardiomyopathies 14.3 Diastolic Function, Filling Pressure, Grading, and Pitfalls

15 Chapter 15: Systolic Function and Ischemia

15.1 LV Systolic Function, Simpson EF, Regional Motion, and Output 15.2 RV Systolic Function: TAPSE, S-prime, FAC, and Coupling 15.3 Ischemic Heart Disease, Coronary Territories, Stress Response, and Complications

16 Chapter 16: Pericardium and Great Vessels

16.1 Pericardial Effusion, Tamponade, Constriction, and Doppler Physiology 16.2 Great Vessels, Venous Return, and Pulmonary Artery Assessment 16.3 Aortic Root, Aneurysm, Dissection, and Coarctation

17 Chapter 17: Pulmonary Pressure, Masses, and Congenital Recognition

17.1 Pulmonary Hypertension, RAP/PASP Estimation, and RV Consequences 17.2 Cardiac Masses, Thrombus, Tumor, Vegetation, and Mimics 17.3 Adult Recognition of ASD, VSD, PFO, PDA, and Congenital Clues

18 Chapter 18: Devices, Strain, and Hemodynamics

18.1 ICDs, Pacemakers, Occluders, Closure Devices, and Mechanical Support 18.2 Strain Interpretation, Global Longitudinal Strain, and Disease Patterns 18.3 Cardiac Hemodynamics, Bernoulli, Continuity, Stroke Volume, and Shunts

19 Chapter 19: Infiltrative Disease and Physics Foundations

19.1 Amyloid, Sarcoid, and Other Infiltrative Disease Patterns 19.2 Ultrasound Wave Properties, Propagation, Frequency, and Wavelength 19.3 Artifact Recognition: Reverberation, Shadowing, Mirror, Refraction, and Aliasing

20 Chapter 20: Resolution and Doppler Optimization

20.1 Axial/Lateral Resolution, Frame Rate, Depth, Focus, and Trade-Offs 20.2 Spectral Doppler Optimization, Nyquist, Filters, Gain, and Angle 20.3 Color Doppler Optimization, Scale, Priority, Variance, and Gain

21 Chapter 21: 2-D, 3-D, and Contrast Optimization

21.1 2-D Optimization: Frequency, Gain, TGC, Harmonics, Depth, and Focus 21.2 3-D Optimization: Volume Rate, Stitching, Cropping, and Display 21.3 Contrast Optimization: Mechanical Index, Destruction, Replenishment, and Artifacts

6.1 Exercise Stress Echo Protocols and Peak Imaging

Key Takeaways Explain This Topic AI

Exercise is preferred when an appropriate patient can exercise because it preserves physiologic responses and provides workload, symptom, ECG, heart-rate, and blood-pressure information.

Acquire reproducible on-axis rest images, preconfigure the stress package, and rehearse patient-to-table positioning before exercise begins.

For treadmill testing, obtain matched postexercise views as rapidly as possible—commonly targeting 60–90 seconds—because transient wall-motion changes can normalize during recovery.

Multiple cycles, matched views, correct labels, and side-by-side rest/peak display are more valuable than one rushed, foreshortened loop.

The sonographer acquires and immediately communicates image or safety findings; the authorized supervising clinician determines test adequacy, interpretation, and protocol termination.

Last updated: July 2026

Peak imaging begins before exercise

CCI task B7 requires performance of exercise echocardiography. When a patient can exercise safely and adequately, exercise is usually preferred for ischemia assessment because it preserves the integrated physiologic response and provides functional capacity, symptoms, heart rate, blood pressure, rhythm, and ECG information. The supervising clinician selects the test and protocol after reviewing the indication, ability to exercise, contraindications, medications, and baseline condition. The sonographer verifies the order and image plan, obtains the assigned history, and reports concerns; the sonographer does not independently cancel medications, choose a stress level, or certify that exercise is safe.

Acquire a focused resting examination before stress. For ischemia, standard matched views include parasternal long and short axes and apical four- and two-chamber views; apical long axis is often added. Optimize depth, sector width, focus, gain, harmonic imaging, ECG triggering, and endocardial borders. Use the same orientation and display convention planned for peak comparison. A rest view that is foreshortened, oblique, or missing a segment cannot serve as a reliable comparator. If two or more contiguous segments are not visualized, alert the supervising team so an ultrasound-enhancing agent can be considered under the order, written protocol, screening, and authorized-administration process.

Phase Sonographer priority Data that must remain linked

Pretest Confirm matched views, windows, labels, ECG, and border quality Indication, symptoms, resting HR and BP

Exercise Keep equipment ready and observe prescribed monitoring Workload, stage, symptoms, HR, BP, rhythm, ECG changes

Peak/postexercise Acquire the predefined view sequence rapidly with multiple cycles Exact timing from exercise, peak workload and HR

Recovery Repeat all views and capture persistent or delayed abnormalities Recovery HR, BP, symptoms, rhythm, interventions

  • Handoff Mark technical limitations and promptly communicate red flags Person notified, time, and response
  • Treadmill and bicycle require different choreography

Treadmill imaging usually occurs at rest, immediately after peak exercise, and in recovery. Before starting, clear the route, place the bed for rapid left-lateral positioning, manage ECG cables, lower the rail as policy allows, and rehearse who supports the patient, obtains blood pressure, operates the treadmill, and scans. Preset the stress package and view order. At termination, patient safety during transfer takes priority, but imaging begins as soon as the patient is stable. ASE guidance considers high-quality images obtained within one to two minutes diagnostically useful; stress-echo training targets commonly emphasize acquisition within 60–90 seconds. Do not waste that window searching menus or relabeling a baseline view.

Heart rate falls quickly, so acquire the most diagnostically important and best-window views first according to laboratory protocol. Use a compact, practiced transducer sequence and capture more than one cardiac cycle per view. Respiratory motion, translational movement, tachycardia, and ectopy can make a single loop misleading. Obtain all views again in early recovery, when an abnormality may persist or become clearer. Display rest and peak or immediate-postexercise loops side by side, synchronized when software permits, and verify that corresponding segments are compared in the same plane.

Supine or semi-supine bicycle stress allows imaging during exercise. Images may be collected at baseline, low or intermediate workloads, peak, and recovery without a treadmill-to-bed transfer. This is especially useful when Doppler hemodynamics are required. The tradeoff is movement, altered windows, and competing demands at peak. Adjust the table and transducer position early, then prioritize the ordered measurements. Upright bicycle testing may require rapid postexercise imaging like treadmill testing, depending on the laboratory setup.

Recognize an acquisition emergency

The team continuously observes clinical condition, ECG, heart rate, and blood pressure. Exercise proceeds toward limiting symptoms or another protocol endpoint rather than treating a percentage of age-predicted heart rate as an automatic sonographer-controlled stop. Red flags include severe or escalating chest pain, syncope or near-syncope, severe dyspnea, pallor or poor perfusion, a significant blood-pressure fall or extreme rise, sustained or dangerous arrhythmia, marked ECG change, or a new severe wall-motion abnormality. The sonographer states the finding immediately and clearly. The supervising clinician decides whether to terminate, but any team member should activate emergency procedures for an immediate threat and should never continue scanning silently.

At peak, a normal response usually includes increased wall thickening and inward excursion with a smaller end-systolic cavity. A new or worsening regional reduction may indicate ischemia, but image artifact, off-axis acquisition, conduction pattern, tethering, and premature beats can mimic it. Capture supporting cycles and notify the supervising clinician without announcing a diagnosis to the patient. Test adequacy includes achieved workload, symptoms, hemodynamics, and image quality—not heart rate alone.

Before ending, confirm the dataset contains matched rest, peak or immediate-postexercise, and recovery views; multiple usable cycles; correct stage labels; and associated HR, BP, workload, symptoms, ECG, contrast use, and limitations. Peak speed matters, but disciplined preparation makes speed diagnostic rather than chaotic.

Peak-image optimization under tachycardia

At peak, shorten imaging depth and sector width only enough to raise frame rate while retaining every required segment. Place the focus at the ventricular level, reduce avoidable persistence, and use an ECG trigger that does not clip systole. Tachycardia may leave only a few frames for wall thickening, so a long low-frame-rate loop is not automatically better than a short optimized one. If breathing motion shifts the apex, reacquire rather than accepting foreshortening. Keep the same transducer orientation as rest, but never force identical settings when attenuation changes; diagnostic segment visibility is the endpoint. Mark ectopic and postectopic cycles so the interpreter can select representative beats.