Study guide
15.1 LV Systolic Function, Simpson EF, Regional Motion, and Output
CCI Registered Cardiac Sonographer RCS
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: RCS Orientation and Clinical Context
1.1 RCS Identity, Exam Format, Application, and Retesting 1.2 Clinical History, Symptoms, Indications, and Risk Factors 1.3 Prior Studies, Serial Change, and Cross-Modality Context
2 Chapter 2: Orders, Safety, and Patient Preparation
2.1 Order Verification, Scope, and Protocol Selection 2.2 Sonographer Ergonomics and Staff Safety 2.3 Patient Preparation, Positioning, Consent, Infection Control, and Aftercare
3 Chapter 3: Reporting and 2-D TTE Foundations
3.1 Structured Findings, Significant Results, and Escalation 3.2 Standard 2-D TTE Windows, Views, and Acquisition Sequence 3.3 2-D Measurements, Foreshortening, Image Quality, and QA
4 Chapter 4: M-Mode and Doppler Acquisition
4.1 M-Mode Alignment, Timing, Measurements, and Pitfalls 4.2 Color Doppler Acquisition, Scale, Gain, and Jet Display 4.3 PW and CW Spectral Doppler Acquisition
5 Chapter 5: Advanced Doppler and Contrast
5.1 Tissue Doppler and Hemodynamic Sample Placement 5.2 Ultrasound-Enhancing Agents and LV Opacification 5.3 Agitated-Saline Studies and Intracardiac Shunts
6 Chapter 6: Stress Echocardiography
6.1 Exercise Stress Echo Protocols and Peak Imaging 6.2 Pharmacologic Stress Echo, Dobutamine, and Safety 6.3 Non-Ischemic Stress Echo and Hemodynamic Provocation
7 Chapter 7: TEE, Strain, and 3-D TEE
7.1 Assisting TEE: Preparation, Probe Safety, Views, and Complications 7.2 Strain Acquisition, Tracking Quality, and Reproducibility 7.3 3-D TEE Acquisition, Cropping, Orientation, and Artifacts
8 Chapter 8: 3-D TTE and the Aortic Valve
8.1 3-D TTE Full-Volume Acquisition and Quantitation 8.2 Aortic-Valve Anatomy, Morphology, and Function 8.3 Aortic Stenosis: Velocities, Gradients, Valve Area, and Flow States
9 Chapter 9: Aortic Regurgitation and Mitral Structure
9.1 Aortic Regurgitation Mechanisms and Integrated Severity 9.2 Mitral-Valve Anatomy, Motion, and Mechanisms 9.3 Mitral Stenosis: Planimetry, Gradients, Pressure Half-Time, and Suitability
10 Chapter 10: Mitral and Tricuspid Valve Findings
10.1 Mitral Regurgitation Mechanism, Quantitation, and Severity Integration 10.2 Tricuspid-Valve Anatomy, Structure, and Function 10.3 Tricuspid Stenosis Assessment
11 Chapter 11: Right-Sided Valve Disease
11.1 Tricuspid Regurgitation Mechanism and Severity 11.2 Pulmonic-Valve Anatomy, Structure, and Function 11.3 Pulmonic Stenosis Assessment
12 Chapter 12: Pulmonic Regurgitation and Prosthetic Valves
12.1 Pulmonic Regurgitation Mechanism and Severity 12.2 Normal Mechanical and Bioprosthetic Valve Assessment 12.3 Prosthetic Obstruction, Regurgitation, Thrombosis, and Patient–Prosthesis Mismatch
13 Chapter 13: Endocarditis and Cardiac Chambers
13.1 Valvular Endocarditis, Vegetations, Abscess, and Complications 13.2 LV and LA Size, Geometry, Volumes, Mass, and Function 13.3 RV and RA Size, Pressure, Volume, and Function
14 Chapter 14: Cardiomyopathy Phenotypes and Diastology
14.1 Dilated and Hypertrophic Cardiomyopathies, SAM, and LVOT Obstruction 14.2 Restrictive, Arrhythmogenic, and Stress Cardiomyopathies 14.3 Diastolic Function, Filling Pressure, Grading, and Pitfalls
15 Chapter 15: Systolic Function and Ischemia
15.1 LV Systolic Function, Simpson EF, Regional Motion, and Output 15.2 RV Systolic Function: TAPSE, S-prime, FAC, and Coupling 15.3 Ischemic Heart Disease, Coronary Territories, Stress Response, and Complications
16 Chapter 16: Pericardium and Great Vessels
16.1 Pericardial Effusion, Tamponade, Constriction, and Doppler Physiology 16.2 Great Vessels, Venous Return, and Pulmonary Artery Assessment 16.3 Aortic Root, Aneurysm, Dissection, and Coarctation
17 Chapter 17: Pulmonary Pressure, Masses, and Congenital Recognition
17.1 Pulmonary Hypertension, RAP/PASP Estimation, and RV Consequences 17.2 Cardiac Masses, Thrombus, Tumor, Vegetation, and Mimics 17.3 Adult Recognition of ASD, VSD, PFO, PDA, and Congenital Clues
18 Chapter 18: Devices, Strain, and Hemodynamics
18.1 ICDs, Pacemakers, Occluders, Closure Devices, and Mechanical Support 18.2 Strain Interpretation, Global Longitudinal Strain, and Disease Patterns 18.3 Cardiac Hemodynamics, Bernoulli, Continuity, Stroke Volume, and Shunts
19 Chapter 19: Infiltrative Disease and Physics Foundations
19.1 Amyloid, Sarcoid, and Other Infiltrative Disease Patterns 19.2 Ultrasound Wave Properties, Propagation, Frequency, and Wavelength 19.3 Artifact Recognition: Reverberation, Shadowing, Mirror, Refraction, and Aliasing
20 Chapter 20: Resolution and Doppler Optimization
20.1 Axial/Lateral Resolution, Frame Rate, Depth, Focus, and Trade-Offs 20.2 Spectral Doppler Optimization, Nyquist, Filters, Gain, and Angle 20.3 Color Doppler Optimization, Scale, Priority, Variance, and Gain
21 Chapter 21: 2-D, 3-D, and Contrast Optimization
21.1 2-D Optimization: Frequency, Gain, TGC, Harmonics, Depth, and Focus 21.2 3-D Optimization: Volume Rate, Stitching, Cropping, and Display 21.3 Contrast Optimization: Mechanical Index, Destruction, Replenishment, and Artifacts
15.1 LV Systolic Function, Simpson EF, Regional Motion, and Output
Key Takeaways Explain This Topic AI
Biplane Simpson EF requires nonforeshortened four- and two-chamber views, correctly timed EDV and ESV, and consistent compacted-myocardium border tracing.
Regional function grades wall thickening and inward excursion across orthogonal views; translation, conduction, pacing, pressure loading, and artifact can mimic ischemic motion.
EF is load and method dependent and may diverge from regional function or forward output, especially with valve regurgitation or altered afterload.
LVOT stroke volume equals area times VTI, cardiac output equals stroke volume times heart rate, and diameter, alignment, beat, and unit errors must be reconciled.
Last updated: July 2026
Build EF from valid volumes
Left ventricular ejection fraction, or LVEF, is the fraction of end-diastolic volume ejected during systole. It is not synonymous with myocardial contractility, stroke volume, or cardiac output. Record heart rate, rhythm, blood pressure, loading interventions, and ventilation because each can change an EF without changing intrinsic myocardium. Acquire nonforeshortened apical four- and two-chamber views with comparable long-axis lengths and the true apex visible. A rounded, shortened apex underestimates both volumes and may distort EF. Reposition the transducer before tracing rather than extending a contour beyond visible anatomy.
For the biplane method of disks, identify end-diastole at mitral closure or the largest LV cavity and end-systole at aortic closure or the smallest cavity. Trace the compacted myocardium–cavity interface in each view and phase. Follow the compacted endocardial boundary without detouring around individual papillary muscles or trabeculations; the volume contour therefore includes those structures within the measured LV chamber. Close the contour at the mitral annular plane without including LA. The software divides both views into corresponding disks to calculate EDV and ESV. Then:
LVEF = (EDV − ESV) / EDV × 100
An EDV of 150 mL paired with an ESV of 60 mL yields 90 mL of stroke volume and a 60% ejection fraction. Index volumes to body surface area, but EF itself is a percentage. The conventional 2-D normal LVEF ranges are 52%–72% in men and 54%–74% in women; use current laboratory, sex-, and method-specific references. Three-dimensional EF is preferred when a complete, high-quality dataset is feasible because it avoids geometric assumptions. It can still fail from dropout, stitching, incomplete pyramids, low temporal resolution, or incorrect automated borders. Preserve whether EF was visual, biplane, 3-D, or contrast-derived for serial interpretation.
Source of error Effect Correction
Apical foreshortening Underestimates EDV and ESV; EF direction is unpredictable Reacquire from the true apex and compare long-axis lengths
Poor endocardial border Changes disk area and regional motion impression Optimize image; use an ultrasound-enhancing agent under protocol when two contiguous segments are not seen
Wrong cardiac phase Mixes nonmaximal EDV or nonminimal ESV Confirm ECG and mitral or aortic valve timing
Irregular rhythm Beat-to-beat EF changes with filling and afterload Average protocol-defined representative beats with similar preceding intervals
Linear volume formula Assumes symmetric geometry and misses regional disease Use biplane disks or valid 3-D rather than Teichholz or Quinones EF
Grade regional motion in multiple views
Evaluate wall thickening and inward endocardial excursion, not motion alone. Divide the LV into the standard 17-segment model and confirm each segment in orthogonal apical and short-axis planes whenever possible. Normal or hyperkinetic tissue thickens and moves inward; hypokinesis means reduced thickening and excursion, akinesis means absent or nearly absent thickening, and dyskinesis means paradoxical systolic expansion. Aneurysmal tissue has persistent diastolic deformation as well as abnormal systolic behavior. Name the segment, grade, and view quality rather than reporting a vague regional abnormality.
Translation, tethering, foreshortening, reverberation, and dropout can simulate abnormal motion. Basal inferoseptal or basal inferior excursion may be reduced by fibrous attachments while thickening remains preserved. LBBB, RV pacing, postoperative motion, RV pressure loading, and cardiomyopathy create noncoronary patterns. Compare adjacent segments and views, track the same tissue from diastole to systole, and reduce depth and sector width without losing landmarks. Strain can support subtle dysfunction but depends on tracking, frame rate, vendor, load, and timing; it does not replace a technically sound visual assessment.
Global and regional measures answer different questions. A small infarct may produce a clear regional abnormality with preserved EF, while diffuse cardiomyopathy can reduce EF without a territorial pattern. Acute severe MR may show a normal or high EF because blood ejects into a low-impedance LA even when forward output is poor. A sudden afterload increase can lower EF without new necrosis. Report regional motion, volumes, EF, loading, valve lesions, and image limitations together; do not diagnose ischemia from one low EF.
Calculate forward stroke volume and output
Doppler forward stroke volume is LVOT cross-sectional area × LVOT VTI . Measure LVOT diameter inner-edge to inner-edge in a correctly aligned parasternal long-axis plane at the same level represented by the PW sample. Calculate area as π × (diameter / 2)² . From an apical long-axis or five-chamber window, place PW just proximal to the aortic valve in laminar flow, align parallel, and trace the dense modal VTI edge. Because diameter is squared, a small diameter error produces a much larger stroke-volume error. Moving the sample into acceleration, tracing noise, or mixing beats also biases output.
Cardiac output = stroke volume × heart rate , and cardiac index = cardiac output / BSA . Convert mL to liters before reporting output. Simpson stroke volume, EDV minus ESV, represents total LV ejection; LVOT Doppler measures forward systemic ejection. They may disagree with significant MR or AR, intracardiac shunt, arrhythmia, or mismatched timing and borders. Cross-check values rather than averaging them. A low cardiac output can coexist with preserved EF when EDV and stroke volume are both small, while a dilated LV may eject a large volume despite a reduced percentage. A defensible systolic report explains how each number was obtained and whether physiology supports it.
Verify serial change and flow meaning
Before calling recovery or deterioration, confirm that image plane, border convention, rhythm sampling, analysis method, blood pressure, and loading state are comparable. Reanalyze prior source images when a small numerical change conflicts with chamber size, regional motion, or clinical physiology. LVOT systolic stroke volume is antegrade aortic ejection; with important AR it includes recirculating volume and should not be equated with net systemic output.
EF is load and geometry dependent
A precise Simpson percentage can still mislead when the apex is foreshortened, borders are incomplete, loading has changed, or severe regurgitation separates total from forward ejection. Interpret EF with volumes, regional motion, output, valves, rhythm, and blood pressure.