Study guide
12.3 Endovascular Aneurysm Repair (EVAR) Surveillance & Endoleaks
CCI Registered Vascular Specialist RVS
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 About the CCI RVS Exam 1.2 How to Prepare for the RVS Exam
2 Principles of Ultrasound Physics & Transducer Technology
2.1 Ultrasound Waves, Propagation Speed & Attenuation 2.2 Transducer Selection & Beam Formation 2.3 Grayscale Instrumentation & B-Mode Optimization
3 Hemodynamics & Doppler Waveform Analysis
3.1 Hemodynamics & Fluid Energy Principles 3.2 The Doppler Equation & Spectral Optimization 3.3 Spectral Waveform & Color Flow Analysis
4 Extracranial Carotid Duplex Evaluation
4.1 Extracranial Cerebrovascular Anatomy & Protocol 4.2 Differentiating ICA vs ECA & Plaque Characterization 4.3 Carotid Velocity Criteria & Stenosis Staging 4.4 Carotid Endarterectomy and Stent Follow-up
5 Vertebral Artery & Intracranial Cerebrovascular Testing
5.1 Vertebral Artery Duplex & Subclavian Steal 5.2 Transcranial Doppler (TCD & TCDI) Principles & Windows 5.3 Intracranial Hemodynamics & Clinical TCD Applications
6 Lower Extremity Peripheral Arterial Physiologic Testing
6.1 Lower Extremity Arterial Anatomy & Clinical Presentation 6.2 Ankle-Brachial Index (ABI) & Toe-Brachial Index (TBI) 6.3 Segmental Pressure Examination 6.4 Pulse Volume Recording (PVR) & Exercise Testing
7 Lower Extremity Arterial Duplex, Bypass & Stent Surveillance
7.1 Lower Extremity Arterial Duplex Protocol 7.2 Arterial Stenosis & Occlusion Diagnostic Criteria 7.3 Bypass Graft Surveillance Protocols & Criteria 7.4 Stent Surveillance, Pseudoaneurysms & Arterial Emergencies
8 Upper Extremity Arterial Testing & Thoracic Outlet Syndrome
8.1 Upper Extremity Arterial Anatomy & Examination Protocol 8.2 Upper Extremity Occlusive Disease & Vasospastic Disorders 8.3 Thoracic Outlet Syndrome (TOS) Evaluation
9 Lower Extremity Deep & Superficial Venous Duplex Evaluation
9.1 Lower Extremity Venous Anatomy & Hemodynamics 9.2 Venous Duplex Protocol for Deep Vein Thrombosis 9.3 Acute vs Chronic DVT Ultrasound Characteristics 9.4 Special Venous Syndromes & Non-Vascular Findings
10 Chronic Venous Insufficiency, Mapping & Reflux Testing
10.1 Pathophysiology of Venous Reflux & CEAP Classification 10.2 Venous Reflux Examination Protocol & Cutoffs 10.3 Saphenous Vein Mapping Protocol & Criteria 10.4 Endovenous Ablation Surveillance & EHIT Classification
11 Upper Extremity Venous Duplex & Central Vein Evaluation
11.1 Upper Extremity Venous Anatomy & Examination Protocol 11.2 Upper Extremity DVT & Effort Thrombosis 11.3 Central Venous Obstruction & Catheter Surveillance
12 Abdominal Aorta, Aneurysms & EVAR Surveillance
12.1 Abdominal Aorta & Iliac Duplex Protocol 12.2 AAA Screening, Growth Rates & Rupture Risk 12.3 Endovascular Aneurysm Repair (EVAR) Surveillance & Endoleaks
13 Visceral Duplex: Renal, Mesenteric & Hepatoportal Systems
13.1 Renal Artery Duplex: Direct Examination & Velocity Criteria 13.2 Renal Artery Duplex: Indirect Intrarenal Waveform Analysis 13.3 Mesenteric Artery Duplex: Celiac, SMA & IMA 13.4 Hepatoportal Hemodynamics & TIPS Surveillance 13.5 Iliocaval Duplex and Venous Stent Assessment 13.6 Kidney and Liver Transplant Vascular Duplex
14 Hemodialysis Access Planning & Surveillance
14.1 Pre-Operative Vascular Mapping for Dialysis Access 14.2 Duplex Evaluation of AV Fistulas & Grafts 14.3 Dialysis Access Complications & Steal Syndrome
15 Patient Care, Safety, Ergonomics & Quality Standards
15.1 Patient Assessment, Clinical Indications & Physical Exam 15.2 Infection Control, Disinfection & Sterile Technique 15.3 Acoustic Bioeffects, ALARA & Safety 15.4 Sonographer Ergonomics & Laboratory Accreditation 15.5 Emergencies, Pharmacology, Ethics and Preliminary Findings
12.3 Endovascular Aneurysm Repair (EVAR) Surveillance & Endoleaks
Key Takeaways Explain This Topic AI
EVAR follow-up assesses the sac, seal zones, modular junctions, graft limbs, and adjacent inflow/outflow.
Classify endoleaks by mechanism: I seal, II branches, III structural defect, IV porosity, V expansion without an identified leak.
Type IIa refers to one communicating branch and IIb to multiple branches, not IMA versus lumbar origin.
Sac growth requires evaluation; Type I/III leaks generally need prompt attention, while stable Type II leaks may be monitored.
After a normal one-month CT baseline, ACC/AHA recommends duplex at 12 months and annually; abnormal findings change follow-up.
Last updated: October 2026
The goal of EVAR follow-up
Endovascular aneurysm repair (EVAR) places a fabric-covered stent-graft inside an aneurysm to exclude the sac from direct arterial flow. Follow-up assesses the repair, sac size, limb patency, and complications. A stent-graft can remain patent while the excluded sac is still perfused. Conversely, a stable sac with no visible leak does not eliminate the need for the prescribed long-term surveillance plan.
Review the device, implantation date, prior imaging, known endoleaks, symptoms, and interventions. Identify the main body, proximal seal, modular junctions, iliac limbs, and distal seals. Complex fenestrated or branched repairs require device-specific protocols beyond a routine infrarenal bifurcated graft assessment. Know what the requested examination can adequately visualize.
Complete duplex acquisition
Use grayscale to assess the sac and visible graft configuration, color or power Doppler to search for flow, and spectral Doppler to characterize suspected channels and limb hemodynamics. Measure the maximum residual sac diameter outer wall to outer wall , including thrombus, in reproducible orthogonal planes. Avoid an oblique measurement of a tortuous sac.
Examine the accessible proximal attachment, main body, component overlaps, both limbs, distal attachments, and adjacent inflow/outflow. Record representative velocities and investigate focal acceleration, kinking, or poor distal flow using validated device/segment criteria. A fixed “normal graft PSV” does not apply to every limb size, device, and hemodynamic state.
Search the excluded sac for slow flow
Set the color scale and wall filter low enough to reveal slow flow while controlling motion artifact. Raise gain to the noise threshold, then reduce it slightly. Scan the sac in several planes and watch for communication with a seal zone, component junction, or branch vessel. Power Doppler can help detect slow flow but remains sensitive to motion and insonation conditions. Confirm suspicious color with spectral sampling when feasible.
A displayed velocity scale in cm/s is not the same quantity as PRF in hertz; their relationship depends on frequency and angle assumptions. Do not present 10–20 cm/s as a universally equivalent PRF value. Settings are starting points that must be optimized on the actual system and patient.
Classify by anatomic mechanism
- Type Mechanism Main concern
- I Inadequate seal at an attachment site Direct sac pressurization; prompt specialist attention
II Retrograde filling through branch vessels such as lumbars or IMA Persistence and sac growth; often observed if stable
- III Component separation or fabric defect Direct sac pressurization; prompt specialist attention
- IV Flow through graft porosity Usually an early device-related phenomenon; distinguish from other leaks
- V Sac expansion without an identified leak, termed endotension Further evaluation for an occult mechanism
Type Ia involves the proximal seal and Ib a distal seal. Type IIIa involves component separation and IIIb a fabric defect. In commonly used Type II subclassification, IIa has a single communicating branch and IIb multiple branches . The distinction is not “IMA versus lumbar”: one lumbar source can be IIa, and multiple feeding/draining vessels can be IIb. If all branches cannot be demonstrated, report Type II without inventing a subtype.
Location and communication are central to classification. Types I and III may show a brisk pulsatile channel; Type II can have low-velocity or bidirectional flow. Waveform speed or a to-and-fro pattern alone does not reliably establish the type. A leak near a seal must be traced rather than labeled from one PSV threshold.
Sac change and clinical significance
Compare with prior measurements made by a consistent method. Sac regression is reassuring; expansion warrants investigation, including consideration of an occult endoleak. A 5 mm change is commonly used as a meaningful reporting trigger, but measurement error, timeframe, type of leak, guideline, and device influence the response. Do not state that any 5 mm expansion automatically mandates a specific intervention.
Types I and III generally require prompt evaluation and correction because they expose the sac to arterial pressure. A stable Type II leak is often monitored. Persistent Type II flow with sac expansion needs specialist review, further imaging, and consideration of treatment. The treating team determines the intervention threshold and method. Type V is a diagnosis of sac expansion without a demonstrated leak, not proof that flow is impossible to detect with another modality.
Worked cases
A stable sac has a posterior low-velocity channel communicating with a lumbar artery. This supports Type II endoleak. If only one branch is demonstrated, do not call it IIb solely because the branch is lumbar. Continued surveillance may be appropriate when the sac is stable, under the treating clinician's plan.
A second patient has a new jet entering the sac beside the proximal attachment and increasing sac diameter. This is concerning for Type Ia seal failure. Preserve the images and communicate promptly. “Low-risk Type II” would be an unsafe assumption merely because a branch vessel is nearby. Additional imaging may clarify the anatomy before repair.
Surveillance and complementary imaging
The 2022 ACC/AHA guideline recommends baseline CT at about one month after EVAR. If there is no endoleak or sac enlargement, duplex at 12 months and annually thereafter is recommended; concerning findings alter the schedule. A six-month study is not universally mandatory after a normal baseline. Periodic cross-sectional imaging can assess components or complications poorly characterized by duplex.
CT angiography evaluates graft geometry and contrast filling, while contrast-enhanced ultrasound can improve slow-flow detection in suitable settings. MRI may be useful for selected devices and patients. Contrast agents, renal function, radiation, metal artifact, availability, and the specific clinical question affect the choice. Document technically limited regions so that a negative ultrasound is not mistaken for a complete exclusion of every complication.
SVS endoleak overview and 2022 ACC/AHA aortic guideline — checked October 18, 2026.
CIRSE endoleak standards of practice, 2024 — supports mechanism-based classification, including single versus multiple communicating branches.