Study guide
13.4 Hepatoportal Hemodynamics & TIPS Surveillance
CCI Registered Vascular Specialist RVS
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 About the CCI RVS Exam 1.2 How to Prepare for the RVS Exam
2 Principles of Ultrasound Physics & Transducer Technology
2.1 Ultrasound Waves, Propagation Speed & Attenuation 2.2 Transducer Selection & Beam Formation 2.3 Grayscale Instrumentation & B-Mode Optimization
3 Hemodynamics & Doppler Waveform Analysis
3.1 Hemodynamics & Fluid Energy Principles 3.2 The Doppler Equation & Spectral Optimization 3.3 Spectral Waveform & Color Flow Analysis
4 Extracranial Carotid Duplex Evaluation
4.1 Extracranial Cerebrovascular Anatomy & Protocol 4.2 Differentiating ICA vs ECA & Plaque Characterization 4.3 Carotid Velocity Criteria & Stenosis Staging 4.4 Carotid Endarterectomy and Stent Follow-up
5 Vertebral Artery & Intracranial Cerebrovascular Testing
5.1 Vertebral Artery Duplex & Subclavian Steal 5.2 Transcranial Doppler (TCD & TCDI) Principles & Windows 5.3 Intracranial Hemodynamics & Clinical TCD Applications
6 Lower Extremity Peripheral Arterial Physiologic Testing
6.1 Lower Extremity Arterial Anatomy & Clinical Presentation 6.2 Ankle-Brachial Index (ABI) & Toe-Brachial Index (TBI) 6.3 Segmental Pressure Examination 6.4 Pulse Volume Recording (PVR) & Exercise Testing
7 Lower Extremity Arterial Duplex, Bypass & Stent Surveillance
7.1 Lower Extremity Arterial Duplex Protocol 7.2 Arterial Stenosis & Occlusion Diagnostic Criteria 7.3 Bypass Graft Surveillance Protocols & Criteria 7.4 Stent Surveillance, Pseudoaneurysms & Arterial Emergencies
8 Upper Extremity Arterial Testing & Thoracic Outlet Syndrome
8.1 Upper Extremity Arterial Anatomy & Examination Protocol 8.2 Upper Extremity Occlusive Disease & Vasospastic Disorders 8.3 Thoracic Outlet Syndrome (TOS) Evaluation
9 Lower Extremity Deep & Superficial Venous Duplex Evaluation
9.1 Lower Extremity Venous Anatomy & Hemodynamics 9.2 Venous Duplex Protocol for Deep Vein Thrombosis 9.3 Acute vs Chronic DVT Ultrasound Characteristics 9.4 Special Venous Syndromes & Non-Vascular Findings
10 Chronic Venous Insufficiency, Mapping & Reflux Testing
10.1 Pathophysiology of Venous Reflux & CEAP Classification 10.2 Venous Reflux Examination Protocol & Cutoffs 10.3 Saphenous Vein Mapping Protocol & Criteria 10.4 Endovenous Ablation Surveillance & EHIT Classification
11 Upper Extremity Venous Duplex & Central Vein Evaluation
11.1 Upper Extremity Venous Anatomy & Examination Protocol 11.2 Upper Extremity DVT & Effort Thrombosis 11.3 Central Venous Obstruction & Catheter Surveillance
12 Abdominal Aorta, Aneurysms & EVAR Surveillance
12.1 Abdominal Aorta & Iliac Duplex Protocol 12.2 AAA Screening, Growth Rates & Rupture Risk 12.3 Endovascular Aneurysm Repair (EVAR) Surveillance & Endoleaks
13 Visceral Duplex: Renal, Mesenteric & Hepatoportal Systems
13.1 Renal Artery Duplex: Direct Examination & Velocity Criteria 13.2 Renal Artery Duplex: Indirect Intrarenal Waveform Analysis 13.3 Mesenteric Artery Duplex: Celiac, SMA & IMA 13.4 Hepatoportal Hemodynamics & TIPS Surveillance 13.5 Iliocaval Duplex and Venous Stent Assessment 13.6 Kidney and Liver Transplant Vascular Duplex
14 Hemodialysis Access Planning & Surveillance
14.1 Pre-Operative Vascular Mapping for Dialysis Access 14.2 Duplex Evaluation of AV Fistulas & Grafts 14.3 Dialysis Access Complications & Steal Syndrome
15 Patient Care, Safety, Ergonomics & Quality Standards
15.1 Patient Assessment, Clinical Indications & Physical Exam 15.2 Infection Control, Disinfection & Sterile Technique 15.3 Acoustic Bioeffects, ALARA & Safety 15.4 Sonographer Ergonomics & Laboratory Accreditation 15.5 Emergencies, Pharmacology, Ethics and Preliminary Findings
13.4 Hepatoportal Hemodynamics & TIPS Surveillance
Key Takeaways Explain This Topic AI
Portal inflow is hepatopetal; hepatic venous outflow toward the heart is hepatofugal.
Hepatic venous S/D flow generally goes toward the heart; atrial contraction can briefly reverse flow toward the liver.
Portal hypertension and Budd-Chiari require integrated findings; one diameter, velocity, or waveform is not independently definitive.
TIPS assessment includes portal inflow, shunt entry/body/outflow, draining veins, clinical symptoms, and baseline comparison.
Abnormal TIPS velocities are screening clues; suspected dysfunction may require venography/pressure assessment rather than automatic revision.
Last updated: October 2026
Establish normal flow directions
The portal vein carries blood from the splanchnic circulation toward the liver: hepatopetal flow. The hepatic artery supplies arterial inflow and normally has sustained forward diastolic flow. The hepatic veins drain blood away from the liver toward the IVC and heart: hepatofugal outflow. These words refer to the liver, not to the probe. Red/blue color and above/below-baseline position depend on the display orientation and must not substitute for anatomic direction.
The main portal vein forms from the splenic and superior mesenteric veins. Trace its branches where accessible and assess lumen, flow direction, velocity, respiratory variation, and surrounding anatomy. Normal portal velocity varies with sampling site, respiration, meals, posture, and measurement method. A single diameter or velocity threshold cannot diagnose every case of portal hypertension.
Hepatic venous waveforms
Hepatic venous pulsatility reflects right atrial events. The S and D components generally carry blood toward the heart, while atrial contraction can cause a brief a-wave reversal toward the liver. A smaller transitional v component may also be present. Because several components occur, the familiar term “triphasic” describes the overall pattern rather than a strict count of every deflection.
Flattening of the waveform is nonspecific. Liver disease, respiratory technique, cardiac conditions, and postoperative anatomy can change pulsatility. Prominent reversal during ventricular systole can occur with severe tricuspid regurgitation. Identify timing and direction instead of treating every reversal as the same mechanism. Transplant reconstructions require their own context and are covered in the transplant section.
Portal hypertension and collateral pathways
Portal hypertension can arise before, within, or after the liver. Cirrhosis is a common intrahepatic cause; portal thrombosis is a prehepatic mechanism, and hepatic venous outflow impairment is another important differential. Ultrasound can show slow or reversed portal flow, collateral vessels, splenomegaly, ascites, and parenchymal changes. No one of these findings is required or independently diagnostic in every patient.
A paraumbilical collateral can connect the left portal system through the falciform/ligamentum teres region to abdominal-wall veins, carrying hepatofugal portal-system drainage. Left gastric and splenorenal/gastrorenal pathways are other collaterals. Trace the vessel and its connections to distinguish collateral flow from an adjacent artery or artifact. Do not assign “100% specificity” to an arbitrary collateral diameter or velocity.
Portal vein thrombosis may be partial or complete. Search for intraluminal material and evaluate residual flow with suitably low scale and filter. Cavernous transformation consists of collateral channels around an obstructed portal segment; it supports an established obstruction but does not provide an exact date of onset. Tumor-associated intravascular tissue can have internal arterial flow and requires further assessment rather than automatic classification as bland thrombus.
Budd-Chiari syndrome concerns hepatic venous outflow obstruction. Evaluate the hepatic veins and accessible IVC for narrowing, thrombus, altered direction, and collateral pathways. Caudate enlargement can occur because of its different venous drainage, but is not pathognomonic. An invisible hepatic vein in a difficult window is not proof that it is thrombosed.
TIPS anatomy and acquisition
A transjugular intrahepatic portosystemic shunt (TIPS) commonly connects a portal branch to a hepatic vein, providing a lower-resistance path to systemic venous outflow. Review the procedure, device, baseline, indication, and recurrent symptoms. Covered devices and older bare stents differ; do not treat every historical velocity rule as equally validated in contemporary covered TIPS.
Examination checklist
Image the main portal vein and accessible branches, documenting direction and representative velocity.
Trace the shunt from portal entry through its body to hepatic venous outflow.
Obtain spectral samples at reproducible inflow, mid-shunt, and outflow locations.
Assess accessible draining hepatic vein/IVC and surrounding liver.
Compare shunt velocities, portal flow direction, ascites, and other findings with baseline.
State technical limitations and communicate concerning changes.
Flow through a functioning shunt is directed toward systemic outflow. Intrahepatic portal branches may reverse toward the shunt entry; interpretation depends on the actual reconstruction and baseline. Spectral velocity varies along the device, and a curved shunt can create difficult Doppler angles. Confirm representative measurements before reporting a focal change.
Suspected dysfunction
Focal acceleration with visible narrowing, a new low-flow state, absent optimized shunt signal, or a significant interval change can suggest dysfunction. Historically cited ranges such as 90–190 cm/s and changes around 50 cm/s are screening clues in some protocols, not universal proofs of a ≥50% stenosis. Covered-stent performance and the complete clinical context matter.
Recurrent ascites or variceal bleeding strengthens concern and should prompt timely assessment by the treating team. Venography with pressure measurements may be needed to confirm dysfunction and guide revision. Duplex cannot determine the portosystemic pressure gradient directly or prescribe revision from one velocity threshold.
Worked interpretation
A patient develops recurrent ascites and a focal outflow velocity of 245 cm/s, compared with a lower baseline. This combination is concerning for shunt dysfunction. Verify the angle and focal anatomy, record the full shunt and portal findings, and communicate promptly. The proper conclusion is suspected dysfunction requiring clinical evaluation, not a guaranteed percentage stenosis or an automatic balloon-angioplasty order.
AASLD guidance describes covered-TIPS Doppler follow-up commonly at 1–4 weeks, 3 and 6 months, then every six months, with modification for symptoms and individual circumstances. Do not call a 24–48-hour scan a universal IAC requirement. Follow the treating service's protocol and recognize that symptoms can require evaluation before any scheduled surveillance date.
AASLD TIPS practice guidance — checked October 18, 2026.