Study guide
1.3 Physical Interfaces and Cabling
Cisco Certified Network Associate CCNA
Track your progress as you read
Finished sections get a check mark.
1 Introduction
About the CCNA 200-301 Exam Domains and Weights Study Strategies and Tips
2 Chapter 1: Network Fundamentals (20%)
1.1 Network Components 1.2 Network Topology Architectures 1.3 Physical Interfaces and Cabling 1.4 TCP vs. UDP 1.5 IPv4 Addressing and Subnetting 1.6 IPv6 Addressing and Prefix 1.7 Wireless Principles 1.8 Virtualization Fundamentals 1.9 Switching Concepts 1.10 OSI and TCP/IP Reference Models 1.11 Verifying IP Parameters on Client Operating Systems
3 Chapter 2: Network Access (20%)
2.1 VLANs — Configuration and Verification 2.2 Trunking and 802.1Q 2.3 Layer 2 Discovery Protocols (CDP and LLDP) 2.4 EtherChannel (Link Aggregation) 2.5 Spanning Tree Protocol (STP) and RSTP 2.6 Wireless Architectures and AP Modes 2.7 Network Access Troubleshooting 2.8 Inter-VLAN Routing — Deep Dive
4 Chapter 3: IP Connectivity (25%)
3.1 Routing Table Components 3.2 Router Forwarding Decisions 3.3 IPv4 and IPv6 Static Routing 3.4 Single-Area OSPFv2 — Concepts 3.5 Single-Area OSPFv2 — Configuration 3.6 First Hop Redundancy Protocols (FHRP) 3.7 Troubleshooting IP Connectivity 3.8 OSPF Troubleshooting Scenarios
5 Chapter 4: IP Services (10%)
4.1 NAT (Network Address Translation) 4.2 DHCP and DNS 4.3 NTP, SNMP, and Syslog 4.4 QoS Fundamentals 4.5 TFTP/FTP and Remote Access 4.6 IP Services — Comprehensive Review
6 Chapter 5: Security Fundamentals (15%)
5.1 Key Security Concepts 5.2 Device Access Control and Password Policies 5.3 VPN Fundamentals 5.4 Access Control Lists (ACLs) 5.5 Layer 2 Security Features 5.6 Network Security Best Practices and Hardening 5.7 Threat Mitigation and Incident Response
7 Chapter 6: Automation and Programmability (10%)
6.1 Impact of Automation on Network Management 6.2 Controller-Based and Software-Defined Architectures 6.3 AI and Machine Learning in Network Operations 6.4 REST-Based APIs 6.5 Configuration Management Tools 6.6 JSON-Encoded Data 6.7 Automation and Programmability — Comprehensive Review
1.3 Physical Interfaces and Cabling
Key Takeaways Explain This Topic AI
Single-mode fiber (8-10 micron core) carries one light path over tens to 100+ km with a laser source.
Multimode fiber (50/62.5 micron core) is cheaper, uses LED/VCSEL, and reaches up to ~400-550 m at 10 Gbps.
UTP copper categories (Cat 5e/6/6a) support 100 m per link; Cat 6a sustains 10GBASE-T to 100 m.
PoE: 802.3af ~15.4 W, 802.3at (PoE+) ~30 W, 802.3bt (PoE++) up to 60/100 W at the source.
Straight-through cables connect unlike devices; crossover connects like devices, but auto-MDIX usually handles it.
Last updated: June 2026
Copper: unshielded twisted pair (UTP)
UTP is the dominant LAN cabling. It uses four twisted pairs of copper terminated in RJ-45 connectors. Twisting cancels crosstalk and electromagnetic interference (EMI). Every UTP link segment is limited to 100 meters regardless of category, this is a hard exam number.
UTP category cheat sheet
- Category Max speed Bandwidth Common use
- Cat 5e 1 Gbps 100 MHz Legacy gigabit
- Cat 6 1 Gbps (10G to ~55 m) 250 MHz Modern gigabit
- Cat 6a 10 Gbps 500 MHz 10GBASE-T to 100 m
- Cat 7/8 10-40 Gbps 600 MHz-2 GHz Data center
Copper is susceptible to EMI and has a hard 100 m reach, so it is used for the last 100 meters to the desk, not for long backbone runs.
Fiber optics
Fiber transmits light , immune to EMI, supports far longer distances, and offers higher bandwidth. Two families:
Single-mode fiber (SMF)
Core ~8-10 microns , a single light path.
Driven by a laser , typically yellow jacket.
Reaches tens of km to 100+ km ; used for WAN and campus backbone.
Multimode fiber (MMF)
Core 50 or 62.5 microns , many light paths, causing modal dispersion.
Driven by LED or VCSEL , often aqua (OM3/OM4) jacket.
Reaches up to roughly 400-550 m at 10 Gbps (OM4); cheaper for in-building runs.
- Property Single-mode Multimode
- Core size 8-10 microns 50 / 62.5 microns
- Light source Laser LED / VCSEL
- Distance up to 100+ km up to ~550 m
- Cost Higher Lower
- Connectors and transceivers
Common fiber connectors include LC, SC, and ST ; copper uses RJ-45 . Modular optics use SFP, SFP+, and QSFP transceivers so one switch port can use copper or various fiber types.
Power over Ethernet (PoE)
PoE delivers DC power and data over the same Ethernet cable, removing the need for a separate power supply for APs, IP phones, and cameras.
- Standard Name Power at source
- 802.3af PoE ~15.4 W
- 802.3at PoE+ ~30 W
- 802.3bt PoE++ (Type 3/4) up to 60 W / 100 W
Some power is lost over the cable, so the device receives slightly less than the source figure.
Straight-through vs crossover
Straight-through connects unlike devices: PC to switch, switch to router.
Crossover connects like devices: switch to switch, router to router, PC to PC.
Mnemonic: routers and PCs are "alike" (both end hosts) for this purpose; switches and hubs are "alike."
Modern switches use auto-MDIX to detect and adjust automatically, so the wrong cable type usually still works on current gear, but the exam tests the manual rule.
Worked example
A 40 km link between two buildings exceeds copper (100 m) and multimode (~550 m), so you must choose single-mode fiber with a laser transceiver . A 90 m run from a switch to a desktop is fine on Cat 6/6a UTP .
Copper Ethernet standards by speed
Match the copper standard to its speed and cabling, a frequent exam pairing:
- Standard Speed Cabling Max distance
- 10BASE-T 10 Mbps Cat 3+ 100 m
- 100BASE-TX 100 Mbps Cat 5+ 100 m
- 1000BASE-T 1 Gbps Cat 5e+ 100 m
- 10GBASE-T 10 Gbps Cat 6a 100 m
Notice the distance never changes, the medium's reach is fixed at 100 m for all twisted-pair Ethernet. The category and standard only raise speed.
Pinouts and the T568 standard
UTP terminations follow the T568A or T568B wiring standard, both define which colored wire lands on which RJ-45 pin. A straight-through cable uses the same standard on both ends (B-to-B or A-to-A). A crossover uses T568A on one end and T568B on the other , which swaps the transmit and receive pairs. Gigabit and 10G use all four pairs, but the legacy 10/100 transmit-on-1,2 and receive-on-3,6 mapping is the classic teaching model behind the crossover concept.
When to use which media
Desk-to-switch and most in-building horizontal runs: Cat 6/6a UTP (cheap, easy, within 100 m).
Switch-to-switch backbone within a building: multimode fiber (immune to EMI, higher speed over a few hundred meters).
Building-to-building or WAN spans of kilometers: single-mode fiber (laser, long reach).
Powering APs/phones/cameras without separate adapters: PoE-capable switch ports matched to the device's PoE class.
Common traps
All UTP categories share the same 100 m limit, higher categories raise speed, not distance.
Multimode cannot reach tens of km, do not pick it for WAN distances.
Auto-MDIX does not change the exam's straight-through/crossover rule.
A device receives slightly less PoE wattage than the source rating because of cable loss, so size the switch's PoE budget with headroom.