Study guide
3.2 Particulate and Aerosol Sampling
CIH Certified Industrial Hygienist Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: The CIH Exam and How to Use This Guide
1.1 CIH Exam Format, Scoring, and Test-Day Logistics 1.2 Eligibility, Application Windows, Fees, and Certification Maintenance 1.3 The BGC Blueprint, Subject Areas, and a Calculation-First Study Plan
2 Chapter 2: Basic Science & Calculations
2.1 Gas Laws and Vapor Calculations 2.2 Unit Conversions: ppm, mg/m³, and Standard Temperature/Pressure 2.3 Fluid Mechanics and Airflow Fundamentals
3 Chapter 3: Air Sampling & Instrumentation
3.1 Active and Passive Air Sampling Strategies 3.2 Particulate and Aerosol Sampling 3.3 Direct-Reading Instruments and Calibration
4 Chapter 4: Analytical Chemistry & Lab Methods
4.1 Gas Chromatography and Mass Spectrometry 4.2 High-Performance Liquid Chromatography and Ion Chromatography 4.3 Spectroscopy and Elemental Analysis 4.4 Gravimetric, Microscopy, and Wet Chemical Methods 4.5 Laboratory Quality Assurance, Chain of Custody, and Desorption Efficiency
5 Chapter 5: Biostatistics & Epidemiology
5.1 Lognormal Distributions and Exposure Data Statistics 5.2 Upper Confidence Limits (UCL95) and Compliance Decision Rules 5.3 Epidemiological Study Designs and Measures of Association 5.4 Sampling Strategy: Sample Size, Power, and Worker Selection
6 Chapter 6: Toxicology & Biological Monitoring
6.1 Dose-Response Relationships and Points of Departure 6.2 Toxicokinetics: Absorption, Distribution, Metabolism, and Elimination 6.3 Aerosol Deposition, Clearance, and Respiratory Tract Dosimetry 6.4 Hepatic, Renal, Neurologic, and Hematologic Target Organ Toxicity 6.5 Pulmonary Toxicology, Carcinogenicity, and Reproductive Hazards 6.6 OEL Frameworks, Classifications, and Excursion Limits 6.7 Chemical Mixtures and Extended Work-Shift OEL Adjustments 6.8 Biological Exposure Indices (BEIs) and Biomonitoring
7 Chapter 7: Biohazards & Indoor Environmental Quality
7.1 Mold, Fungi, and Microbial Contaminants 7.2 Infectious Agents, Bloodborne Pathogens, and Biosafety Levels 7.3 Indoor Environmental Quality (IEQ) Investigations 7.4 Sanitation, Potable Water, and Personal Hygiene Programs
8 Chapter 8: Community Exposure & Environmental Health
8.1 Clean Air Act Framework, NAAQS, and New Source Review 8.2 Hazardous Air Pollutants, CEMS, and EPA Reference Methods 8.3 Atmospheric Stability, Lapse Rates, and Plume Morphology 8.4 Gaussian Plume Modeling, Plume Rise, and Environmental Fate 8.5 HAZWOPER Scope, Mandates, and Training Tiers 8.6 Protection Levels, Site Zoning, Incident Command, and Decontamination 8.7 Water Pollution, Hazardous Waste, and Community Right-to-Know
9 Chapter 9: Health Risk Analysis & Hazard Communication
9.1 GHS Hazard Classification: Health and Physical Hazard Criteria 9.2 GHS Labels, Safety Data Sheets, and Trade Secret Rules 9.3 The AIHA Exposure Assessment Strategy and Similar Exposure Groups 9.4 Qualitative Exposure Profiling and the AIHA Risk Matrix 9.5 Quantitative Health Risk Characterization: HQ, HI, and ELCR 9.6 NIOSH Occupational Exposure Banding 9.7 Risk Communication and Reporting to Affected Parties
10 Chapter 10: Industrial Ventilation Principles & LEV Design
10.1 Elimination, Substitution, Isolation, Containment, and Process Change 10.2 LEV Hood Taxonomy and Capture Velocity Selection 10.3 Hood Airflow Equations, Entry Losses, and Hood Static Pressure 10.4 Particulate Transport Aerodynamics and Duct Sizing 10.5 Duct Friction, Fitting Losses, and System Balancing 10.6 Fan Categories and Pressure Dynamics Across the Fan 10.7 System Curves, the Fan Laws, and Density Corrections
11 Chapter 11: General Ventilation, Air Cleaning & Diagnostics
11.1 Dilution Ventilation Principles and Steady-State Modeling 11.2 Transient Purging and Air Distribution Geometry 11.3 Particulate Air Cleaning: Cyclones, Baghouses, Scrubbers, and ESPs 11.4 Gaseous Emission Control and Air Cleaner Selection 11.5 Ventilation System Troubleshooting and Testing
12 Chapter 12: Noise Measurement & Hearing Conservation
12.1 Acoustic Physics and Decibel Mathematics 12.2 Sound Propagation, Octave Bands, and Frequency Weighting 12.3 Noise Dose Metrics and OSHA versus ACGIH Criteria 12.4 Exchange Rates, Extended Shifts, and Dosimetry Field Protocols 12.5 Engineering Noise Controls and Hearing Protector Attenuation 12.6 Hearing Conservation Programs and Standard Threshold Shifts 12.7 Hand-Arm and Whole-Body Vibration
13 Chapter 13: Thermal Stress Assessment & Control
13.1 Wet Bulb Globe Temperature (WBGT) and Heat Stress Indices 13.2 Heat-Related Disorders, Acclimatization, and Work/Rest Regimens 13.3 Cold Stress Evaluation and Wind Chill
14 Chapter 14: Ionizing Radiation Protection
14.1 Ionizing Radiation Physics and Radioactive Decay Kinetics 14.2 Radiation Units, Radiobiology, and Health Effects 14.3 ALARA, Stay-Time, and the Inverse Square Law 14.4 Shielding Physics, Material Selection, and Gamma Constants 14.5 Radiation Detection Instruments and Spectrometry 14.6 Personnel Dosimetry, Dose Limits, and Contamination Surveys
15 Chapter 15: Non-Ionizing Radiation & Laser Safety
15.1 The Non-Ionizing Spectrum and Static/ELF Field Exposures 15.2 Radiofrequency and Microwave Exposure: SAR, Standards, and Surveys 15.3 Ultraviolet, Visible, and Infrared Radiation Hazards 15.4 Laser Safety Classifications and Optical Density Calculations 15.5 Illumination, Lighting Design, and Visual Performance
16 Chapter 16: Non-Engineering Controls & Personal Protective Equipment
16.1 Respiratory Protection Programs and Assigned Protection Factors 16.2 Maximum Use Concentration, Oxygen Deficiency, and Breathing Air 16.3 Particulate Filters, Sorbent Cartridges, and Change Schedules 16.4 Respirator Fit Testing Protocols 16.5 Chemical Protective Clothing and Dermal Exposure Control
17 Chapter 17: Ergonomics & Workstation Design
17.1 Soft-Tissue Biomechanics and WMSD Pathophysiology 17.2 Ergonomic Risk Factors and Their Interaction Effects 17.3 The Revised NIOSH Lifting Equation 17.4 RULA, REBA, the Strain Index, and the ACGIH HAL TLV 17.5 Anthropometry and Workstation Geometry 17.6 VDT Workstations, Hand Tool Design, and Administrative Ergonomics
18 Chapter 18: Work Environments & Industrial Processes
18.1 Welding Fume Emissions, Metal Fume Fever, and Cr(VI)/Manganese Toxicology 18.2 Foundry Operations and Hot Work Fire Prevention 18.3 Vapor Degreasing, Pickling, Electroplating, and Cyanide Baths 18.4 Spray Coatings, Isocyanates, and Semiconductor Manufacturing 18.5 Confined Spaces and High-Hazard Industrial Operations 18.6 Asbestos, Lead, and Silica: Regulated Substance Programs 18.7 Abrasive Blasting and Surface Preparation
19 Chapter 19: IH Program Management & Professional Ethics
19.1 The BGC Code of Ethics: Canons and Enforcement 19.2 Professional Liability, Standard of Care, and Expert Testimony 19.3 Occupational Health & Safety Management Systems (ISO 45001, ANSI Z10) 19.4 Exposure Records Access and Medical Surveillance 19.5 OSHA Injury and Illness Recordkeeping and Enforcement
3.2 Particulate and Aerosol Sampling
Key Takeaways Explain This Topic AI
Aerodynamic Equivalent Diameter (dae) defines a spherical particle of unit density (1.0 g/cm³) with the same gravitational settling velocity as the particle under study.
ACGIH/ISO/CEN size-selective conventions define three primary fractions: Inhalable (d50 = 100 µm), Thoracic (d50 = 10 µm), and Respirable (d50 = 4.0 µm).
The standard 10-mm Dorr-Oliver nylon cyclone must be operated at precisely 1.7 L/min to achieve the 4.0 µm respirable cut point, whereas the SKC aluminum cyclone operates at 2.5 L/min to eliminate electrostatic distortion.
Filter media must match analytical methods: Mixed Cellulose Ester (MCE) for metals (ICP-AES) and asbestos (PCM/TEM); Polyvinyl Chloride (PVC) for gravimetric dust and silica (XRD/FTIR); Quartz fiber for diesel particulate matter (EC/OC).
Aerosol size distributions are characterized by Mass Median Aerodynamic Diameter (MMAD) and Geometric Standard Deviation (GSD), where GSD >= 1.2 denotes a polydisperse aerosol.
Last updated: August 2026
2.2 Particulate and Aerosol Sampling
Industrial aerosols comprise airborne suspensions of solid particles or liquid droplets, including dusts, mists, fumes, smokes, and bioaerosols. The toxicological impact of an inhaled aerosol is determined by its chemical composition , its mass concentration , and critically, its deposition location within the human respiratory tract.
Because deposition depends fundamentally on particle aerodynamic behavior, modern occupational health standards specify particle size-selective sampling criteria rather than collecting non-differentiated "total" particulate.
Aerosol Physics & Aerodynamic Equivalent Diameter
Workplace particles possess irregular geometric shapes and variable material densities. To standardize physical behavior, industrial hygiene defines particle dimensions in terms of Aerodynamic Equivalent Diameter (dae) .
Note
Definition of Aerodynamic Equivalent Diameter (dae) :
The diameter of a hypothetical spherical particle of unit density (ρ0 = 1.0 g/cm³ = 1000 kg/m³) that has the exact same gravitational terminal settling velocity (vts) in still air as the particle under consideration. Irregular Particle Equivalent Aerodynamic Sphere
(Actual density ρp, Volume-equivalent dv) (Standard unit density ρ0 = 1.0 g/cm³, dae)
****** .--------.
- ********** / \
- ************ SAME TERMINAL SETTLING | ρ0 = 1.0 | dae
- ********** VELOCITY (vts) \ g/cm³ /
- ****** =======================> '--------'
- Terminal Settling Velocity (vts)
For particles in the continuum regime (0.5 µm < dae < 50 µm) governed by Stokes' Law with the Cunningham Slip Correction Factor (Cc) : v ts = ρ p ⋅ d p 2 ⋅ g ⋅ C c 18 ⋅ η = ρ 0 ⋅ d ae 2 ⋅ g ⋅ C c 18 ⋅ η v_{\text{ts}} = \frac{\rho_{\text{p}} \cdot d_{\text{p}}^2 \cdot g \cdot C_{\text{c}}}{18 \cdot \eta} = \frac{\rho_0 \cdot d_{\text{ae}}^2 \cdot g \cdot C_{\text{c}}}{18 \cdot \eta} v ts = 18 ⋅ η ρ p ⋅ d p 2 ⋅ g ⋅ C c = 18 ⋅ η ρ 0 ⋅ d ae 2 ⋅ g ⋅ C c
Where:
- ρp = Actual particle density (g/cm³)
- ρ0 = Standard unit density (1.0 g/cm³)
- dp = Physical or geometric diameter (cm)
- g = Acceleration due to gravity (980.665 cm/s²)
- η = Dynamic viscosity of air (1.81 × 10⁻⁴ poise or g/(cm · s) at 20°C)
Cc = Cunningham slip correction factor (accounts for non-continuum slip as particle size approaches the mean free path of air molecules, λ ≈ 0.066 µm)
Equating both forms reveals the fundamental relationship between aerodynamic diameter, physical diameter, and particle density: d ae = d p ⋅ ρ p ρ 0 ⋅ C c ( d p ) C c ( d ae ) ≈ d p ⋅ ρ p ρ 0 d_{\text{ae}} = d_{\text{p}} \cdot \sqrt{\frac{\rho_{\text{p}}}{\rho_0} \cdot \frac{C_{\text{c}}(d_{\text{p}})}{C_{\text{c}}(d_{\text{ae}})}} \approx d_{\text{p}} \cdot \sqrt{\frac{\rho_{\text{p}}}{\rho_0}} d ae = d p ⋅ ρ 0 ρ p ⋅ C c ( d ae ) C c ( d p ) ≈ d p ⋅ ρ 0 ρ p
(For dense particles such as lead dust with ρp = 11.34 g/cm³, a small 1.0 µm physical particle behaves aerodynamically like a 3.37 µm sphere, depositing higher in the respiratory tree than its physical size suggests).
Particle Size-Selective Sampling Criteria (ACGIH / ISO / CEN)
The American Conference of Governmental Industrial Hygienists (ACGIH), International Organization for Standardization (ISO 7708), and European Standardization Committee (CEN) harmonize size-selective sampling into three anatomical fractions defined by their 50% cut point (d50) : +-----------------------------------------------------------------------------------------+
- | RESPIRATORY TRACT DEPOSITION & SAMPLING CONVENTIONS |
- | |
- | +---------------------------------------------------------------------------------+ |
- | | INHALABLE FRACTION (d50 = 100 µm) | |
- | | Enters nose and mouth; deposits throughout entire respiratory tract. | |
- | | Samplers: IOM at 2.0 L/min, Button Sampler at 4.0 L/min | |
- | +---------------------------------------+-----------------------------------------+ |
- | | |
- | v |
- | +---------------------------------------------------------------------------------+ |
- | | THORACIC FRACTION (d50 = 10 µm) | |
- | | Penetrates larynx into trachea and bronchial airways. | |
- | | Target Hazards: Sulfuric acid mist, cotton dust. | |
- | +---------------------------------------+-----------------------------------------+ |
- | | |
- | v |
- | +---------------------------------------------------------------------------------+ |
- | | RESPIRABLE FRACTION (d50 = 4.0 µm) | |
- | | Penetrates unciliated gas-exchange region (alveoli). | |
- | | Target Hazards: Crystalline silica, coal dust. | |
- | | Samplers: Dorr-Oliver (1.7 L/min), SKC Aluminum (2.5 L/min) | |
- | +---------------------------------------------------------------------------------+ |
- +-----------------------------------------------------------------------------------------+
- 1. Inhalable Particulate Mass (IPM)
Anatomical Definition : Particles that enter the nose and mouth during breathing and deposit anywhere in the respiratory tract (head airways, tracheobronchial, and pulmonary alveolar regions).
Cut Point : d50 = 100 µm .
Collection Efficiency Curve : E I ( d ae ) = 0.50 ⋅ [ 1 + exp ( − 0.06 ⋅ d ae ) ] for d ae ≤ 100 μ m E_{\text{I}}(d_{\text{ae}}) = 0.50 \cdot \left[ 1 + \exp(-0.06 \cdot d_{\text{ae}}) \right] \quad \text{for } d_{\text{ae}} \le 100\text{ }\mu\text{m} E I ( d ae ) = 0.50 ⋅ [ 1 + exp ( − 0.06 ⋅ d ae ) ] for d ae ≤ 100 μ m
Standard Collection Devices :
IOM Sampler : Institute of Occupational Medicine conductive plastic or stainless steel cassette operated at 2.0 L/min . The entire internal filter plus cassette housing is weighed as a unit to capture wall deposits.
Button Aerosol Sampler : Porous curved-screen inlet operated at 4.0 L/min , minimizing ambient wind direction sensitivity.
Limitation of Traditional 37-mm Closed-Face Cassette (CFC) : The traditional 37-mm CFC severely undersamples particles larger than 30 µm, underestimating true inhalable particulate exposure by up to 50% in wood, grain, or metal processing environments.
2. Thoracic Particulate Mass (TPM)
Anatomical Definition : Particles that bypass the head airways (extrathoracic region) and penetrate through the larynx into the conducting airways (trachea and bronchi).
Cut Point : d50 = 10 µm .
Target Hazards : Sulfuric acid mist (ACGIH TLV-TWA 0.2 mg/m³ thoracic), cotton dust, berylliosis agents.
Sampling Devices : Thoracic cyclones (e.g., BGI GK2.69 at 1.6 L/min) or Parallel Particle Impactors (PPI).
3. Respirable Particulate Mass (RPM)
Anatomical Definition : Particles that penetrate deep into the unciliated gas-exchange region of the lungs ( alveoli ), where macrophage clearance mechanisms operate.
Cut Point : d50 = 4.0 µm (ACGIH/ISO/CEN criterion; note that the historical British Medical Research Council / BMRC curve used d50 = 5.0 µm, and older 1968 ACGIH guidelines used 3.5 µm).
Target Hazards : Respirable crystalline silica (α-quartz, cristobalite, tridymite), respirable coal dust, talc.
Respirable Size-Selective Samplers: Cyclones & Impactors
A cyclone is a centrifugal separator that uses high-speed rotational airflow to remove coarse particles. Air enters tangentially at the cyclone inlet, forming a high-velocity downward spiral. Particles with high inertia (> d50) are thrown against the outer cylinder wall by centrifugal force, lose kinetic energy, and fall into the grit pot . The inner vortex reverses and carries respirable particles (< d50) upward onto the collection filter. Tangential Air Inflow Filter Stage (Respirable Fraction)
- ======================> [ Cyclone Body ] +--------------------------------+
- | | | Filter Paper |
- | Downward | +--------------------------------+
- | Outer Vortex | ^
- | | | (Upward Inner Vortex)
- | | |
- \ / ----------------------------------
- \ Taper /
- \ /
- +----------+
- | Grit Pot | (Coarse particles > 4.0 µm discarded)
- +----------+
- Major Cyclones and Mandatory Calibrated Flow Rates
Operating a cyclone at an incorrect flow rate alters the internal centrifugal acceleration, drastically shifting the cut point:
Higher Flow Rate : Increases centrifugal force arrow lowers d50 cut point arrow underestimates respirable mass.
Lower Flow Rate : Decreases centrifugal force arrow raises d50 cut point arrow allows non-respirable particles onto filter arrow overestimates respirable mass.
Cyclone Model Material Construction Calibrated Flow Rate for 4.0 µm Cut Point Technical Characteristics & Limitations
10-mm Dorr-Oliver Non-conductive Nylon 1.7 L/min Industry standard historically; vulnerable to electrostatic charge accumulation in dry environments, altering collection efficiency.
SKC Aluminum Cyclone Conductive Aluminum 2.5 L/min Dissipates static electrical charges; non-sparking; eliminates orientation biases.
Higgins-Dewell (HD) Conductive Plastic / Metal 2.2 L/min Closely conforms to the ISO/CEN/ACGIH 4.0 µm respirable curve; used extensively in UK/EU.
BGI GK2.69 Cyclone Conductive Stainless Steel 4.2 L/min High-flow respirable sampler; collects 2.5x more mass per hour, crucial for low-concentration silica environments.
Parallel Particle Impactor (PPI) Conductive Plastic / Aluminum 2.0, 4.0, or 8.0 L/min Uses internal micro-impaction stages instead of a cyclone; eliminates grit pot and orientation sensitivity.
Warning
Field Cyclone Protocol :
Cyclones must always remain in a vertical, upright orientation during and after sampling. If an active cyclone is inverted or tilted past horizontal, non-respirable coarse particles from the grit pot will dump directly onto the filter face, invalidating the gravimetric and chemical analysis.
Filter Media Selection Guide
Selecting the correct analytical filter membrane is governed by chemical compatibility, gravimetric stability, digestion properties, and the required instrumental finishing technique.
Filter Medium Structure / Properties Primary Industrial Hygiene Applications Analytical Finish & Method
Mixed Cellulose Ester (MCE) Hydrophilic cellulose nitrate/acetate blend; dissolved completely by mineral acids; transparent when cleared Metals, welding fumes, element screening, asbestos fibers Acid digestion / ICP-AES (NIOSH 7300/7303); Phase Contrast Microscopy (PCM, NIOSH 7400)
Polyvinyl Chloride (PVC) Hydrophobic, extremely low moisture absorption (non-hygroscopic); low tare weight; low ash content Total & respirable dusts, crystalline silica, hexavalent chromium Gravimetric weighing (NIOSH 0500/0600); X-ray Diffraction (XRD, NIOSH 7500); FTIR (NIOSH 7602)
Polytetrafluoroethylene (PTFE / Teflon) Porous stretched fluoropolymer membrane; chemically inert; high temperature resistance; low background Acidic/alkaline mists, reactive chemicals, polynuclear aromatic hydrocarbons (PAHs), fluorides Ion Chromatography (IC, NIOSH 7903); HPLC/GC-MS
Quartz Fiber (Heat-Treated) Pure micro-quartz fibers; binder-free; thermally stable up to 800°C Diesel Particulate Matter (DPM), elemental/organic carbon, polycyclic organics Thermal-Optical Transmittance (TOT) / Flame Ionization (NIOSH 5040)
Glass Fiber Borosilicate glass; high loading capacity; high flow permeability Pesticides, non-volatile organic aerosols, high-volume ambient particulate Solvent extraction / GC-ECD / HPLC
Particle Size Distribution: MMAD and GSD
Aerosol populations in occupational settings are rarely monodisperse (all particles having identical size). Instead, they exhibit lognormal particle size distributions . Cumulative Mass % (Probability Scale)
- 99.9 +
- |
- 84.1 +--------------------------------------------o (d84.1)
- | /|
- | / |
- 50.0 +---------------------------------o (MMAD)/ |
- | /| / |
- 15.9 +-----------------------o (d15.9)/| / |
- | /| / | / |
- 0.1 +---------------------+--------+------+------+-----> Log Particle Aerodynamic
- d15.9 MMAD d84.1 Diameter (dae, µm)
- Definitions & Formulae
Mass Median Aerodynamic Diameter (MMAD) : The aerodynamic diameter (d50) at which exactly 50% of the total aerosol mass is contained in particles smaller than this diameter, and 50% in particles larger.
Geometric Standard Deviation (GSD, σg) : The measure of aerosol polydispersity (breadth of the particle size spread), determined from log-probability plots: σ g = d 84.1 % d 50 % = d 50 % d 15.9 % = d 84.1 % d 15.9 % \sigma_{\text{g}} = \frac{d_{84.1\%}}{d_{50\%}} = \frac{d_{50\%}}{d_{15.9\%}} = \sqrt{\frac{d_{84.1\%}}{d_{15.9\%}}} σ g = d 50% d 84.1% = d 15.9% d 50% = d 15.9% d 84.1%
Monodisperse Aerosol : σg < 1.2 (typically generated only in laboratory aerosol research).
Polydisperse Aerosol : σg ≥ 1.2 (virtually all real-world occupational aerosols, with typical workplace GSD values ranging from 1.5 to 3.5).
Cascade Impactors
Cascade impactors (e.g., the 8-stage Andersen Cascade Impactor or personal Marple impactors) measure particle size distributions directly. Air is drawn through successive stages with progressively smaller nozzles. At each stage, air jets accelerate; particles exceeding the stage cut point (d50) possess sufficient inertia to break out of air streamlines and impact onto an impaction substrate, while smaller particles remain entrained and pass to the next stage.
Worked Step-by-Step Example: Respirable Silica Exposure Calculation ========================================================================================
- WORKED EXAMPLE: Respirable Crystalline Silica Compliance Assessment
- ========================================================================================
Scenario:
- An industrial hygienist conducts personal exposure monitoring on a concrete grinding
- worker. A 37-mm PVC filter (5.0 µm pore size) mounted in an SKC Aluminum Cyclone is
operated at 2.50 L/min for 420 minutes (7.0 hours).
Laboratory Analytical Results (NIOSH 0600 / NIOSH 7500 XRD):
- Pre-sampling filter tare weight (W1) = 15.420 mg
- Post-sampling filter gross weight (W2) = 16.295 mg
- Field blank net weight change (W_blank) = +0.015 mg
- Crystalline quartz mass via XRD (m_silica) = 48.0 µg
- ---------------------------------------------------------------------------------------
- Step 1: Calculate Total Air Volume Sampled (V)
- V = Q × t = 2.50 L/min × 420 min = 1050 L
- V = 1050 L / 1000 L/m³ = 1.050 m³
- Step 2: Calculate Net Respirable Dust Mass on Sample Filter
- m_gross_dust = W2 - W1 = 16.295 mg - 15.420 mg = 0.875 mg
- m_net_dust = m_gross_dust - W_blank = 0.875 mg - 0.015 mg = 0.860 mg (860 µg)
- Step 3: Calculate Respirable Dust Concentration
- C_dust = m_net_dust / V = 0.860 mg / 1.050 m³ = 0.819 mg/m³ (819 µg/m³)
- Step 4: Calculate Respirable Crystalline Quartz Concentration
- C_silica = m_silica / V = 48.0 µg / 1.050 m³ = 45.71 µg/m³ (0.0457 mg/m³)
- Step 5: Calculate Percentage Quartz in the Respirable Dust
- % Quartz = (m_silica / m_net_dust) × 100%
- % Quartz = (48.0 µg / 860 µg) × 100% = 5.58%
- Step 6: Evaluate Compliance against OSHA Standards
- OSHA Permissible Exposure Limit (PEL) for Respirable Crystalline Silica = 50.0 µg/m³
- OSHA Action Level (AL) for Respirable Crystalline Silica = 25.0 µg/m³
- Finding: The worker's 8-hour TWA exposure is 45.71 µg/m³. This is below the PEL (50 µg/m³)
- but exceeds the OSHA Action Level (25 µg/m³), triggering mandatory periodic exposure
monitoring, medical surveillance, and inclusion in the written exposure control plan.