Study guide

4.2 High-Performance Liquid Chromatography and Ion Chromatography

CIH Certified Industrial Hygienist Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: The CIH Exam and How to Use This Guide

1.1 CIH Exam Format, Scoring, and Test-Day Logistics 1.2 Eligibility, Application Windows, Fees, and Certification Maintenance 1.3 The BGC Blueprint, Subject Areas, and a Calculation-First Study Plan

2 Chapter 2: Basic Science & Calculations

2.1 Gas Laws and Vapor Calculations 2.2 Unit Conversions: ppm, mg/m³, and Standard Temperature/Pressure 2.3 Fluid Mechanics and Airflow Fundamentals

3 Chapter 3: Air Sampling & Instrumentation

3.1 Active and Passive Air Sampling Strategies 3.2 Particulate and Aerosol Sampling 3.3 Direct-Reading Instruments and Calibration

4 Chapter 4: Analytical Chemistry & Lab Methods

4.1 Gas Chromatography and Mass Spectrometry 4.2 High-Performance Liquid Chromatography and Ion Chromatography 4.3 Spectroscopy and Elemental Analysis 4.4 Gravimetric, Microscopy, and Wet Chemical Methods 4.5 Laboratory Quality Assurance, Chain of Custody, and Desorption Efficiency

5 Chapter 5: Biostatistics & Epidemiology

5.1 Lognormal Distributions and Exposure Data Statistics 5.2 Upper Confidence Limits (UCL95) and Compliance Decision Rules 5.3 Epidemiological Study Designs and Measures of Association 5.4 Sampling Strategy: Sample Size, Power, and Worker Selection

6 Chapter 6: Toxicology & Biological Monitoring

6.1 Dose-Response Relationships and Points of Departure 6.2 Toxicokinetics: Absorption, Distribution, Metabolism, and Elimination 6.3 Aerosol Deposition, Clearance, and Respiratory Tract Dosimetry 6.4 Hepatic, Renal, Neurologic, and Hematologic Target Organ Toxicity 6.5 Pulmonary Toxicology, Carcinogenicity, and Reproductive Hazards 6.6 OEL Frameworks, Classifications, and Excursion Limits 6.7 Chemical Mixtures and Extended Work-Shift OEL Adjustments 6.8 Biological Exposure Indices (BEIs) and Biomonitoring

7 Chapter 7: Biohazards & Indoor Environmental Quality

7.1 Mold, Fungi, and Microbial Contaminants 7.2 Infectious Agents, Bloodborne Pathogens, and Biosafety Levels 7.3 Indoor Environmental Quality (IEQ) Investigations 7.4 Sanitation, Potable Water, and Personal Hygiene Programs

8 Chapter 8: Community Exposure & Environmental Health

8.1 Clean Air Act Framework, NAAQS, and New Source Review 8.2 Hazardous Air Pollutants, CEMS, and EPA Reference Methods 8.3 Atmospheric Stability, Lapse Rates, and Plume Morphology 8.4 Gaussian Plume Modeling, Plume Rise, and Environmental Fate 8.5 HAZWOPER Scope, Mandates, and Training Tiers 8.6 Protection Levels, Site Zoning, Incident Command, and Decontamination 8.7 Water Pollution, Hazardous Waste, and Community Right-to-Know

9 Chapter 9: Health Risk Analysis & Hazard Communication

9.1 GHS Hazard Classification: Health and Physical Hazard Criteria 9.2 GHS Labels, Safety Data Sheets, and Trade Secret Rules 9.3 The AIHA Exposure Assessment Strategy and Similar Exposure Groups 9.4 Qualitative Exposure Profiling and the AIHA Risk Matrix 9.5 Quantitative Health Risk Characterization: HQ, HI, and ELCR 9.6 NIOSH Occupational Exposure Banding 9.7 Risk Communication and Reporting to Affected Parties

10 Chapter 10: Industrial Ventilation Principles & LEV Design

10.1 Elimination, Substitution, Isolation, Containment, and Process Change 10.2 LEV Hood Taxonomy and Capture Velocity Selection 10.3 Hood Airflow Equations, Entry Losses, and Hood Static Pressure 10.4 Particulate Transport Aerodynamics and Duct Sizing 10.5 Duct Friction, Fitting Losses, and System Balancing 10.6 Fan Categories and Pressure Dynamics Across the Fan 10.7 System Curves, the Fan Laws, and Density Corrections

11 Chapter 11: General Ventilation, Air Cleaning & Diagnostics

11.1 Dilution Ventilation Principles and Steady-State Modeling 11.2 Transient Purging and Air Distribution Geometry 11.3 Particulate Air Cleaning: Cyclones, Baghouses, Scrubbers, and ESPs 11.4 Gaseous Emission Control and Air Cleaner Selection 11.5 Ventilation System Troubleshooting and Testing

12 Chapter 12: Noise Measurement & Hearing Conservation

12.1 Acoustic Physics and Decibel Mathematics 12.2 Sound Propagation, Octave Bands, and Frequency Weighting 12.3 Noise Dose Metrics and OSHA versus ACGIH Criteria 12.4 Exchange Rates, Extended Shifts, and Dosimetry Field Protocols 12.5 Engineering Noise Controls and Hearing Protector Attenuation 12.6 Hearing Conservation Programs and Standard Threshold Shifts 12.7 Hand-Arm and Whole-Body Vibration

13 Chapter 13: Thermal Stress Assessment & Control

13.1 Wet Bulb Globe Temperature (WBGT) and Heat Stress Indices 13.2 Heat-Related Disorders, Acclimatization, and Work/Rest Regimens 13.3 Cold Stress Evaluation and Wind Chill

14 Chapter 14: Ionizing Radiation Protection

14.1 Ionizing Radiation Physics and Radioactive Decay Kinetics 14.2 Radiation Units, Radiobiology, and Health Effects 14.3 ALARA, Stay-Time, and the Inverse Square Law 14.4 Shielding Physics, Material Selection, and Gamma Constants 14.5 Radiation Detection Instruments and Spectrometry 14.6 Personnel Dosimetry, Dose Limits, and Contamination Surveys

15 Chapter 15: Non-Ionizing Radiation & Laser Safety

15.1 The Non-Ionizing Spectrum and Static/ELF Field Exposures 15.2 Radiofrequency and Microwave Exposure: SAR, Standards, and Surveys 15.3 Ultraviolet, Visible, and Infrared Radiation Hazards 15.4 Laser Safety Classifications and Optical Density Calculations 15.5 Illumination, Lighting Design, and Visual Performance

16 Chapter 16: Non-Engineering Controls & Personal Protective Equipment

16.1 Respiratory Protection Programs and Assigned Protection Factors 16.2 Maximum Use Concentration, Oxygen Deficiency, and Breathing Air 16.3 Particulate Filters, Sorbent Cartridges, and Change Schedules 16.4 Respirator Fit Testing Protocols 16.5 Chemical Protective Clothing and Dermal Exposure Control

17 Chapter 17: Ergonomics & Workstation Design

17.1 Soft-Tissue Biomechanics and WMSD Pathophysiology 17.2 Ergonomic Risk Factors and Their Interaction Effects 17.3 The Revised NIOSH Lifting Equation 17.4 RULA, REBA, the Strain Index, and the ACGIH HAL TLV 17.5 Anthropometry and Workstation Geometry 17.6 VDT Workstations, Hand Tool Design, and Administrative Ergonomics

18 Chapter 18: Work Environments & Industrial Processes

18.1 Welding Fume Emissions, Metal Fume Fever, and Cr(VI)/Manganese Toxicology 18.2 Foundry Operations and Hot Work Fire Prevention 18.3 Vapor Degreasing, Pickling, Electroplating, and Cyanide Baths 18.4 Spray Coatings, Isocyanates, and Semiconductor Manufacturing 18.5 Confined Spaces and High-Hazard Industrial Operations 18.6 Asbestos, Lead, and Silica: Regulated Substance Programs 18.7 Abrasive Blasting and Surface Preparation

19 Chapter 19: IH Program Management & Professional Ethics

19.1 The BGC Code of Ethics: Canons and Enforcement 19.2 Professional Liability, Standard of Care, and Expert Testimony 19.3 Occupational Health & Safety Management Systems (ISO 45001, ANSI Z10) 19.4 Exposure Records Access and Medical Surveillance 19.5 OSHA Injury and Illness Recordkeeping and Enforcement

4.2 High-Performance Liquid Chromatography and Ion Chromatography

Key Takeaways Explain This Topic AI

HPLC separates non-volatile, thermally labile, and highly polar analytes that gas chromatography cannot handle without derivatisation or decomposition.

Reversed-phase HPLC uses a non-polar C18 stationary phase with a polar aqueous-organic mobile phase, so more polar analytes elute first.

Isocyanates are collected on a derivatising reagent such as 1-(2-pyridyl)piperazine and analysed by HPLC with ultraviolet and fluorescence detection.

Ion chromatography separates inorganic anions and cations on an ion-exchange column with suppressed conductivity detection, and is the reference technique for hexavalent chromium with post-column diphenylcarbazide.

The choice between GC and HPLC is driven by analyte volatility and thermal stability, not by concentration or sample volume.

Last updated: August 2026

High-Performance Liquid Chromatography and Ion Chromatography

Gas chromatography can only analyse what will vaporise intact. A large and growing fraction of workplace contaminants will not: isocyanates polymerise, formaldehyde is too reactive and volatile to trap conventionally, hexavalent chromium is an inorganic ion, and amines and acids are too polar for a standard GC column. These analytes are handled by liquid-phase chromatography , and the CIH exam expects you to know which technique a given analyte requires and why.

1. The Selection Rule Is the analyte volatile AND thermally stable at 200-300 C?

  • | |
  • YES NO
  • | |
  • Gas Chromatography Is it an ion or ionisable

(GC-FID, GC-MS, GC-ECD) inorganic species?

  • | |
  • YES NO
  • | |
  • Ion Chromatography HPLC
  • (suppressed (reversed-phase,
  • conductivity) UV/fluorescence)

The discriminator is volatility and thermal stability , not concentration or sample size. A candidate who reaches for GC because "it is the standard IH technique" will get isocyanate and chromate questions wrong.

2. High-Performance Liquid Chromatography

In HPLC the mobile phase is a liquid pumped at high pressure (typically 1,000 to 6,000 psi) through a column packed with small (3–5 µm) particles. Separation depends on the analyte's relative affinity for the stationary and mobile phases.

Reversed-phase versus normal-phase

Stationary phase Mobile phase Elution order

Reversed-phase (the workhorse, >80% of IH methods) Non-polar, typically C18 (octadecylsilane) bonded silica Polar: water/acetonitrile or water/methanol Polar analytes elute first ; non-polar are retained longest

Normal-phase Polar, bare silica or amino/cyano bonded Non-polar: hexane with a polar modifier Non-polar analytes elute first

  • The name is historical: normal-phase came first, so the more useful configuration got called "reversed."
  • Isocratic versus gradient elution

Isocratic: mobile phase composition held constant. Simple, reproducible, but poor at resolving mixtures with a wide polarity range.

Gradient: organic fraction increased during the run (for example 20% to 90% acetonitrile). Sharpens late peaks and shortens run time, at the cost of column re-equilibration between injections.

HPLC detectors

Detector Basis Typical IH use

UV-Visible / diode array Absorbance at selected wavelength(s) The general-purpose detector; requires a chromophore

  • Fluorescence Emission after excitation Isocyanate–1-2PP derivatives; far more selective and sensitive than UV
  • Electrochemical Oxidation/reduction at an electrode Phenols, thiols, some amines

Mass spectrometric (LC-MS/MS) Mass-to-charge of ions Confirmation and trace-level quantitation of complex matrices

  • Refractive index Bulk RI change Analytes with no chromophore; insensitive and gradient-incompatible
  • 3. Ion Chromatography

Ion chromatography (IC) is HPLC configured for ionic species . The column carries fixed charged functional groups; analyte ions exchange with counter-ions and are separated by charge density and size.

The defining feature is suppressed conductivity detection . The eluent itself is ionic and would swamp a conductivity detector, so a suppressor placed between the column and the detector chemically converts the eluent to a low-conductivity form (for example, converting sodium hydroxide eluent to water) while converting analyte anions to their more conductive acid forms. The result is a large signal-to-background improvement.

Industrial hygiene applications of IC:

  • Inorganic anions: fluoride, chloride, nitrate, nitrite, phosphate, sulphate
  • Acid gases collected on treated filters or in impingers: HCl, HF, HNO₃, H₂SO₄
  • Amines and quaternary ammonium compounds (cation exchange)
  • Hexavalent chromium , which is the highest-stakes IC application in industrial hygiene
  • Hexavalent chromium: why the method matters

Cr(VI) is a Category 1 carcinogen with an OSHA PEL of 5 µg/m³ and an action level of 2.5 µg/m³. The analytical challenge is that Cr(VI) can be reduced to Cr(III) on the filter by co-collected iron, welding fume, or acidic conditions, producing a falsely low result.

The reference approach separates Cr(VI) by ion chromatography and detects it by post-column reaction with 1,5-diphenylcarbazide , forming an intensely coloured complex measured at about 540 nm. Because the chromatographic step separates Cr(VI) from Cr(III) before the colour reaction, the method reports only the hexavalent species. Sample handling matters as much as the instrument: alkaline extraction and prompt analysis limit inter-conversion.

4. Practical Considerations the Exam Tests

Derivatisation is a collection step, not a lab afterthought. Isocyanate sampling media are impregnated with the derivatising reagent so the reaction occurs at the moment of collection , before the isocyanate can polymerise. Formaldehyde is collected on 2,4-dinitrophenylhydrazine-coated media for the same reason.

Mobile phase composition is part of the method. Substituting methanol for acetonitrile changes retention and can invalidate identification by retention time.

HPLC is not inherently more sensitive than GC. Sensitivity depends on the detector; a fluorescence detector on a derivatised analyte can outperform GC-FID by orders of magnitude, while a refractive index detector is far worse.

Holding times are method-specific. Derivatised isocyanate samples and Cr(VI) samples both have limited stability, and exceeding the holding time is a data quality defect that must be flagged, not silently ignored.