Study guide

7.1 Mold, Fungi, and Microbial Contaminants

CIH Certified Industrial Hygienist Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: The CIH Exam and How to Use This Guide

1.1 CIH Exam Format, Scoring, and Test-Day Logistics 1.2 Eligibility, Application Windows, Fees, and Certification Maintenance 1.3 The BGC Blueprint, Subject Areas, and a Calculation-First Study Plan

2 Chapter 2: Basic Science & Calculations

2.1 Gas Laws and Vapor Calculations 2.2 Unit Conversions: ppm, mg/m³, and Standard Temperature/Pressure 2.3 Fluid Mechanics and Airflow Fundamentals

3 Chapter 3: Air Sampling & Instrumentation

3.1 Active and Passive Air Sampling Strategies 3.2 Particulate and Aerosol Sampling 3.3 Direct-Reading Instruments and Calibration

4 Chapter 4: Analytical Chemistry & Lab Methods

4.1 Gas Chromatography and Mass Spectrometry 4.2 High-Performance Liquid Chromatography and Ion Chromatography 4.3 Spectroscopy and Elemental Analysis 4.4 Gravimetric, Microscopy, and Wet Chemical Methods 4.5 Laboratory Quality Assurance, Chain of Custody, and Desorption Efficiency

5 Chapter 5: Biostatistics & Epidemiology

5.1 Lognormal Distributions and Exposure Data Statistics 5.2 Upper Confidence Limits (UCL95) and Compliance Decision Rules 5.3 Epidemiological Study Designs and Measures of Association 5.4 Sampling Strategy: Sample Size, Power, and Worker Selection

6 Chapter 6: Toxicology & Biological Monitoring

6.1 Dose-Response Relationships and Points of Departure 6.2 Toxicokinetics: Absorption, Distribution, Metabolism, and Elimination 6.3 Aerosol Deposition, Clearance, and Respiratory Tract Dosimetry 6.4 Hepatic, Renal, Neurologic, and Hematologic Target Organ Toxicity 6.5 Pulmonary Toxicology, Carcinogenicity, and Reproductive Hazards 6.6 OEL Frameworks, Classifications, and Excursion Limits 6.7 Chemical Mixtures and Extended Work-Shift OEL Adjustments 6.8 Biological Exposure Indices (BEIs) and Biomonitoring

7 Chapter 7: Biohazards & Indoor Environmental Quality

7.1 Mold, Fungi, and Microbial Contaminants 7.2 Infectious Agents, Bloodborne Pathogens, and Biosafety Levels 7.3 Indoor Environmental Quality (IEQ) Investigations 7.4 Sanitation, Potable Water, and Personal Hygiene Programs

8 Chapter 8: Community Exposure & Environmental Health

8.1 Clean Air Act Framework, NAAQS, and New Source Review 8.2 Hazardous Air Pollutants, CEMS, and EPA Reference Methods 8.3 Atmospheric Stability, Lapse Rates, and Plume Morphology 8.4 Gaussian Plume Modeling, Plume Rise, and Environmental Fate 8.5 HAZWOPER Scope, Mandates, and Training Tiers 8.6 Protection Levels, Site Zoning, Incident Command, and Decontamination 8.7 Water Pollution, Hazardous Waste, and Community Right-to-Know

9 Chapter 9: Health Risk Analysis & Hazard Communication

9.1 GHS Hazard Classification: Health and Physical Hazard Criteria 9.2 GHS Labels, Safety Data Sheets, and Trade Secret Rules 9.3 The AIHA Exposure Assessment Strategy and Similar Exposure Groups 9.4 Qualitative Exposure Profiling and the AIHA Risk Matrix 9.5 Quantitative Health Risk Characterization: HQ, HI, and ELCR 9.6 NIOSH Occupational Exposure Banding 9.7 Risk Communication and Reporting to Affected Parties

10 Chapter 10: Industrial Ventilation Principles & LEV Design

10.1 Elimination, Substitution, Isolation, Containment, and Process Change 10.2 LEV Hood Taxonomy and Capture Velocity Selection 10.3 Hood Airflow Equations, Entry Losses, and Hood Static Pressure 10.4 Particulate Transport Aerodynamics and Duct Sizing 10.5 Duct Friction, Fitting Losses, and System Balancing 10.6 Fan Categories and Pressure Dynamics Across the Fan 10.7 System Curves, the Fan Laws, and Density Corrections

11 Chapter 11: General Ventilation, Air Cleaning & Diagnostics

11.1 Dilution Ventilation Principles and Steady-State Modeling 11.2 Transient Purging and Air Distribution Geometry 11.3 Particulate Air Cleaning: Cyclones, Baghouses, Scrubbers, and ESPs 11.4 Gaseous Emission Control and Air Cleaner Selection 11.5 Ventilation System Troubleshooting and Testing

12 Chapter 12: Noise Measurement & Hearing Conservation

12.1 Acoustic Physics and Decibel Mathematics 12.2 Sound Propagation, Octave Bands, and Frequency Weighting 12.3 Noise Dose Metrics and OSHA versus ACGIH Criteria 12.4 Exchange Rates, Extended Shifts, and Dosimetry Field Protocols 12.5 Engineering Noise Controls and Hearing Protector Attenuation 12.6 Hearing Conservation Programs and Standard Threshold Shifts 12.7 Hand-Arm and Whole-Body Vibration

13 Chapter 13: Thermal Stress Assessment & Control

13.1 Wet Bulb Globe Temperature (WBGT) and Heat Stress Indices 13.2 Heat-Related Disorders, Acclimatization, and Work/Rest Regimens 13.3 Cold Stress Evaluation and Wind Chill

14 Chapter 14: Ionizing Radiation Protection

14.1 Ionizing Radiation Physics and Radioactive Decay Kinetics 14.2 Radiation Units, Radiobiology, and Health Effects 14.3 ALARA, Stay-Time, and the Inverse Square Law 14.4 Shielding Physics, Material Selection, and Gamma Constants 14.5 Radiation Detection Instruments and Spectrometry 14.6 Personnel Dosimetry, Dose Limits, and Contamination Surveys

15 Chapter 15: Non-Ionizing Radiation & Laser Safety

15.1 The Non-Ionizing Spectrum and Static/ELF Field Exposures 15.2 Radiofrequency and Microwave Exposure: SAR, Standards, and Surveys 15.3 Ultraviolet, Visible, and Infrared Radiation Hazards 15.4 Laser Safety Classifications and Optical Density Calculations 15.5 Illumination, Lighting Design, and Visual Performance

16 Chapter 16: Non-Engineering Controls & Personal Protective Equipment

16.1 Respiratory Protection Programs and Assigned Protection Factors 16.2 Maximum Use Concentration, Oxygen Deficiency, and Breathing Air 16.3 Particulate Filters, Sorbent Cartridges, and Change Schedules 16.4 Respirator Fit Testing Protocols 16.5 Chemical Protective Clothing and Dermal Exposure Control

17 Chapter 17: Ergonomics & Workstation Design

17.1 Soft-Tissue Biomechanics and WMSD Pathophysiology 17.2 Ergonomic Risk Factors and Their Interaction Effects 17.3 The Revised NIOSH Lifting Equation 17.4 RULA, REBA, the Strain Index, and the ACGIH HAL TLV 17.5 Anthropometry and Workstation Geometry 17.6 VDT Workstations, Hand Tool Design, and Administrative Ergonomics

18 Chapter 18: Work Environments & Industrial Processes

18.1 Welding Fume Emissions, Metal Fume Fever, and Cr(VI)/Manganese Toxicology 18.2 Foundry Operations and Hot Work Fire Prevention 18.3 Vapor Degreasing, Pickling, Electroplating, and Cyanide Baths 18.4 Spray Coatings, Isocyanates, and Semiconductor Manufacturing 18.5 Confined Spaces and High-Hazard Industrial Operations 18.6 Asbestos, Lead, and Silica: Regulated Substance Programs 18.7 Abrasive Blasting and Surface Preparation

19 Chapter 19: IH Program Management & Professional Ethics

19.1 The BGC Code of Ethics: Canons and Enforcement 19.2 Professional Liability, Standard of Care, and Expert Testimony 19.3 Occupational Health & Safety Management Systems (ISO 45001, ANSI Z10) 19.4 Exposure Records Access and Medical Surveillance 19.5 OSHA Injury and Illness Recordkeeping and Enforcement

7.1 Mold, Fungi, and Microbial Contaminants

Key Takeaways Explain This Topic AI

Water activity (aw) thresholds strictly govern fungal colonization: primary/xerophilic colonizers (aw = 0.70-0.80, e.g., Aspergillus, Penicillium), secondary/mesophilic colonizers (aw = 0.80-0.90, e.g., Cladosporium, Alternaria), and tertiary/hydrophilic colonizers (aw > 0.90, e.g., Stachybotrys chartarum, Chaetomium globosum).

Spore trap non-viable impaction (e.g., Air-O-Cell at 15 L/min for 2-10 min) quantifies total spores/m³ but cannot morphologically distinguish Aspergillus from Penicillium (reported as 'Asp/Pen-like'); culturable viable impaction (Andersen N6 at 28.3 L/min onto MEA or DG-18) requires positive-hole statistical correction to report CFU/m³.

No health-based numerical Occupational Exposure Limits (OELs, PELs, TLVs) exist for airborne mold spores; data interpretation relies on indoor vs. outdoor rank-order genus comparison, dominant indoor taxa identification, and baseline building differentials.

IICRC S520 establishes fungal building ecology conditions: Condition 1 (Normal fungal ecology), Condition 2 (Settled spores/debris), and Condition 3 (Actual active/dormant growth); EPA remediation guidelines mandate full containment with HEPA negative air machines (NAMs) for contiguous amplification areas exceeding 100 square feet.

Last updated: August 2026

Mold, Fungi, and Microbial Contaminants

Bioaerosols and fungal contamination represent critical challenges in occupational hygiene and building science. Unlike abiotic chemical toxins with established dose-response curves and numerical exposure limits, biological agents such as fungi, bacteria, and their metabolic byproducts interact dynamically with building envelopes, HVAC systems, and occupant immune systems. Certified Industrial Hygienists must master the ecological physics of moisture transfer, water activity (aw), fungal taxonomy, specialized bioaerosol sampling physics, comparative data interpretation, and containment engineering for remediation.

1. Fungal Ecology, Moisture Dynamics, and Water Activity (aw)

Fungi are eukaryotic, heterotrophic micro-organisms that reproduce by dispersing microscopic spores (conidia) and propagate vegetative filamentous structures called hyphae , which collectively form a mycelium . Fungi do not synthesize chlorophyll and require an external organic carbon substrate (e.g., cellulose in drywall paper backing, wood studs, ceiling tiles, carpet dust, or wallpaper paste) combined with bioavailable moisture to germinate and amplify.

Water Activity (aw) vs. Moisture Content

In building materials, the presence of liquid water is characterized by two distinct metrics:

Moisture Content (MC%): The gravimetric ratio of the mass of water to the dry mass of the solid material, expressed as a percentage.

Water Activity (aw): The fundamental thermodynamic measure of the chemical potential or bioavailability of free water in a substrate. It is mathematically defined as the ratio of the equilibrium vapor pressure of water in or on the material (p) to the saturated vapor pressure of pure water (p0) at the identical temperature: a w = p p 0 = Equilibrium Relative Humidity (ERH) 100 a_w = \frac{p}{p_0} = \frac{\text{Equilibrium Relative Humidity (ERH)}}{100} a w ​ = p 0 ​ p ​ = 100 Equilibrium Relative Humidity (ERH) ​

Where ERH is the relative humidity of the interstitial air in thermodynamic equilibrium with the material.

Fungal Colonization Succession Hierarchy

Fungal species colonize building materials in a predictable ecological succession dictated primarily by substrate water activity:

Colonization Class Water Activity (aw) Range Equilibrium RH Representative Fungal Genera & Species Typical Substrates & Ecological Behavior

Primary Colonizers (Xerophilic / Xerotolerant) aw = 0.70 - 0.80 70% - 80% Aspergillus versicolor , Aspergillus restrictus , Penicillium chrysogenum , Penicillium brevicompactum , Eurotium spp., Wallemia sebi Dust reservoirs, wallpaper, wallboard facing under chronically high ambient humidity; early biofilm formation.

Secondary Colonizers (Mesophilic) aw = 0.80 - 0.90 80% - 90% Cladosporium sphaerospermum , Cladosporium herbarum , Alternaria alternata , Curvularia , Phoma spp. Moderately damp drywall, painted surfaces, HVAC coils, window frame condensation points.

Tertiary Colonizers (Hydrophilic / 'Water Damage' Indicators) aw > 0.90 > 90% Stachybotrys chartarum , Chaetomium globosum , Trichoderma viride , Ulocladium chartarum , Acremonium spp. Chronic, severe water saturation (leaks, plumbing bursts, flooding) on high-cellulose/low-nitrogen substrates (gypsum drywall paper).

Key Principle: The physical presence of viable tertiary colonizers like Stachybotrys chartarum or Chaetomium globosum indoors is a definitive indicator of chronic liquid water intrusion (aw > 0.90). Because Stachybotrys conidia are enveloped in a wet, heavy, slimy polysaccharide matrix, they are not easily aerosolized during quiescent conditions unless the substrate dries out, is physically disturbed, or undergoes mechanical demolition.

2. Microbial Secondary Metabolites: Mycotoxins, mVOCs, and β-Glucans

Fungi exert physiological effects on building occupants not only via direct allergic hypersensitivity to structural spore proteins, but also through non-allergic and toxicological pathways driven by secondary metabolites and cell-wall components.

Mycotoxins

Mycotoxins are non-volatile, low-molecular-weight secondary fungal metabolites synthesized during stationary growth phases, often as biochemical defenses against competing micro-organisms:

Aflatoxins: Synthesized by Aspergillus flavus and Aspergillus parasiticus . Potent difuranocoumarin derivatives; Aflatoxin B1 is one of the most potent known hepatocarcinogens (IARC Group 1) and causes severe cytochrome P450-mediated DNA adducts and liver failure.

Trichothecenes (Macrocyclic Trichothecenes): Synthesized by Stachybotrys chartarum , Myrothecium , and Fusarium . Compounds include Satratoxin G and H , Roridin E , and Verrucarin J . They are potent inhibitors of eukaryotic protein synthesis via peptidyl transferase binding on the 60S ribosomal subunit, causing cytotoxicity, mucous membrane ulceration, and immune dysregulation.

Ochratoxin A: Synthesized by Aspergillus ochraceus and Penicillium verrucosum . Potent nephrotoxin, teratogen, and putative renal carcinogen that interferes with phenylalanine-tRNA synthetase.

Sterigmatocystin: Structurally related precursor to aflatoxin produced by Aspergillus versicolor ; hepatotoxic and genotoxic.

Microbial Volatile Organic Compounds (mVOCs)

mVOCs are low-molecular-weight metabolic byproducts of active fungal and bacterial digestion that possess high vapor pressures at room temperature. They are responsible for the characteristic pungent, moldy, or "earthy" odor associated with hidden microbial amplification:

1-Octen-3-ol ("Mushroom alcohol"): Imparts a heavy, pungent mold odor; acts as an upper airway irritant.

Geosmin (trans-1,10-dimethyl-trans-9-decalol): Imparts an intense earthy/dirt odor; synthesized by both fungi and filamentous actinomycetes ( Streptomyces ), with human olfactory detection thresholds below 10 ng/L (parts-per-trillion levels).

2-Methylisoborneol (MIB): Musty, camphorous odor.

3-Methylfuran, 2-Hexanone, and 2-Heptanone: Common volatile ketones/furans contributing to indoor odor complaints and transient mucous membrane irritation.

Exam Fact: While mVOCs cause significant subjective discomfort, headache, and olfactory fatigue, indoor mass concentrations of mVOCs are typically in the sub-ppb or low µg/m³ range—orders of magnitude below industrial toxicological Permissible Exposure Limits (PELs) for corresponding industrial VOCs.

(1→ 3)-β-D-Glucans

β-Glucans are glucose polymers that form the structural backbone of fungal cell walls. They are biologically potent pathogen-associated molecular patterns (PAMPs) that trigger macrophage and neutrophil activation via Dectin-1 and toll-like receptors (TLR-2/6), inducing non-allergic airway inflammation, cough, and subfebrile reactions.

3. Bioaerosol Sampling Physics, Methods, and Calibration

Industrial hygienists utilize both non-culturable and culturable air sampling modalities to evaluate bioaerosols. Each method has distinct operational physics, sampling flow rates, and analytical constraints. ┌─────────────────────────────┐

  • │ Bioaerosol Sampling Modality │
  • └──────────────┬──────────────┘
  • │
  • ┌───────────────────────────┴───────────────────────────┐
  • ▼ ▼
  • ┌───────────────────────────────┐ ┌───────────────────────────────┐
  • │ Non-Culturable Spore Traps │ │ Culturable Viable Samplers │
  • │ (e.g., Air-O-Cell, Allergenco)│ │ (e.g., Andersen N6 Impactor) │
  • ├───────────────────────────────┤ ├───────────────────────────────┤
  • │ • Flow Rate: 15.0 L/min │ │ • Flow Rate: 28.3 L/min (1 CFM)│
  • │ • Duration: 2 - 10 minutes │ │ • Duration: 1 - 5 minutes │
  • │ • Captures viable + dead │ │ • Agar: MEA, DG-18 │
  • │ • Direct optical microscopy │ │ • Requires Positive-Hole Corr.│
  • │ • Reports: Total Spores/m³ │ │ • Reports: CFU/m³ │
  • └───────────────────────────────┘ └───────────────────────────────┘
  • Non-Culturable Spore-Trap Impaction (e.g., Air-O-Cell, Allergenco-D)

Operating Principle: Air is accelerated through a narrow rectangular slit nozzle (15.0 L/min) and impacts an adhesive-coated glass slide. Inertial impaction traps particles with aerodynamic diameters typically down to ~ 1.5-2.0µm.

Sampling Duration: Typically 2 to 10 minutes. In clean indoor environments, 10 minutes (150 L) is standard; in dusty construction zones or heavy amplification, 2 to 5 minutes prevents slide overloading (particle masking).

Laboratory Analysis: Direct optical light microscopy at 400×-1000× magnification. Both viable and non-viable spores are counted.

Critical Morphological Limitation: Spores of Aspergillus and Penicillium are small (2-5µm), round-to-ovoid, hyaline conidia that lack distinguishing morphological features under optical light microscopy without reproductive structures (conidiophores). Laboratories must report them as a combined group: "Aspergillus/Penicillium-like" (or "Asp/Pen group" ).

Culturable Viable Air Impaction (Andersen N6 Sampler)

Operating Principle: A single-stage sieve impactor with 400 precision-drilled orifices operating at a calibrated critical airflow of 28.3 L/min (1.0 CFM) . Air jets direct airborne particles directly onto an agar nutrient plate situated below the jet stage.

Culture Media:

Malt Extract Agar (MEA): Broad-spectrum general fungal growth medium (aw ≈ 0.98).

Dichloran 18% Glycerol Agar (DG-18): Low water activity (aw ≈ 0.95) medium that inhibits fast-growing spreading mucoraceous fungi and selectively promotes xerophilic species ( Aspergillus , Penicillium , Wallemia ).

The Positive-Hole Correction Method: When sampling high concentrations of airborne viable spores, there is a statistical probability that two or more spores will pass through the same orifice jet and land at the exact same location on the agar, forming a single colony-forming unit (CFU). Industrial hygienists must convert the raw counted colony count (r) to a statistically corrected colony count (C) using the Macher positive-hole correction formula or published tables before computing concentration: C = N ⋅ [ 1 N + 1 N − 1 + 1 N − 2 + ⋯ + 1 N − r + 1 ] = N ⋅ ln ⁡ ( N N − r ) C = N \cdot \left[\frac{1}{N} + \frac{1}{N-1} + \frac{1}{N-2} + \dots + \frac{1}{N-r+1}\right] = N \cdot \ln\left(\frac{N}{N - r}\right) C = N ⋅ [ N 1 ​ + N − 1 1 ​ + N − 2 1 ​ + ⋯ + N − r + 1 1 ​ ] = N ⋅ ln ( N − r N ​ )

Where N = 400 (total number of stage orifices) and r is the observed raw colony count.

Surface and Bulk Sampling Protocols

Tape Lift / Tape Slide: Clear cellophane adhesive tape applied lightly to visible discoloration and adhered to a glass microscope slide. Provides immediate direct identification of mycelial growth structures (hyphae, conidiophores) versus settled inert dust.

Swab Sampling: Sterile Dacron/cotton swab in liquid transport medium for culturable colony isolation or molecular PCR analysis.

Bulk Destructive Sampling: 2× 2 inch square of suspect sheetrock or carpet backing excised for laboratory extraction.

4. Bioaerosol Data Interpretation and Comparative Analysis

There are no health-based numerical Occupational Exposure Limits (PELs, RELs, or TLVs) for airborne mold or fungi. Fungal susceptibility is governed by individual host immunological status, atopic sensitization, and pre-existing respiratory disease rather than linear toxic thresholds. Therefore, data interpretation relies on a comparative epidemiological framework .

Principles of Bioaerosol Data Interpretation

Concurrent Outdoor Baseline Comparison: Outdoor air samples collected simultaneously (both upwind and downwind of the building) serve as the ecological reference baseline for ambient spore burden.

Quantitative Differential: In a non-problem, mechanically ventilated building equipped with standard filtration (MERV 8 or higher) under closed-window conditions, total indoor fungal concentrations are typically significantly lower than outdoor concentrations (I/O ratio < 0.5-0.7).

Qualitative / Rank-Order Equivalence: The relative abundance and rank-order of dominant fungal genera indoors should mirror outdoor air (where phylloplane fungi such as Cladosporium , Alternaria , and basidiospores naturally dominate).

Dominance of Problematic Taxa: Indoor dominance of Aspergillus/Penicillium-like spores, or any detectable presence of tertiary water-damage indicators ( Stachybotrys chartarum , Chaetomium , Trichoderma ) in indoor air when absent outdoors, strongly indicates an active, amplification reservoir.

5. Mold Remediation Standards, IICRC S520, and Containment Protocols

Remediation of indoor fungal ecology must follow established consensus standards, notably the IICRC S520 (Standard for Professional Mold Remediation) and EPA's Mold Remediation in Schools and Commercial Buildings .

IICRC S520 Environmental Condition Classifications

Condition 1 (Normal Fungal Ecology): An indoor environment that may have settled spores, fungal fragments, or traces of actual growth whose identity, location, and quantity are reflective of a normal fungal ecology for an indoor environment.

Condition 2 (Settled Spores): An indoor environment contaminated with settled spores or fungal fragments that were dispersed from a Condition 3 area, but where active vegetative growth is not occurring on surfaces.

Condition 3 (Actual Growth): An indoor environment contaminated with the presence of actual mold growth (active or dormant), associated with moisture intrusion or structural water damage.

EPA Containment & Engineering Control Thresholds

Remediation Level Contaminated Surface Area Engineering Containment Required Ventilation & Negative Pressure Worker Personal Protective Equipment (PPE)

Small / Level I < 10 ft² (< 0.9 m²) None required; isolate immediate work zone. Standard room ventilation; seal local return vents. N95 filtering facepiece respirator, safety goggles, nitrile/nitrile-blend gloves.

Medium / Level II 10 - 100 ft² (0.9 - 9.3 m²) Limited containment: 6-mil polyethylene sheet dust barrier isolating work area; seal HVAC supply/return. HEPA-filtered air scrubber or exhaust negative air machine (NAM) recommended. Half-mask elastomeric APR with P100 filters, eye goggles, protective disposable gloves.

Large / Level III & IV > 100 ft² (> 9.3 m²) contiguous Full Containment: Double-layer 6-mil polyethylene sheeting, decontamination chamber (airlock/anteroom with flapped zipper doors). Continuous negative pressure (≥ -0.02 in. w.g. / -5 Pa) with dedicated HEPA NAMs exhausted directly outdoors (≥ 4-8 ACH). Full-facepiece elastomeric APR or PAPR with P100 HEPA filters, disposable Tyvek coveralls with integrated hood and boots.

Post-Remediation Verification (PRV) / Clearance Criteria

Before containment barriers are disassembled, a formal PRV must be conducted by an independent certified industrial hygienist (not the remediation contractor):

Visual & Tactile Inspection: Complete absence of visible mold, dust, debris, and moisture on all structural framing and surfaces inside containment.

Moisture Equilibrium: Structural wood moisture content must be < 15%-17% wood moisture equivalent (WME).

Air / Surface Clearance Sampling: Verification that the indoor fungal ecology has been returned to Condition 1 status.

  • 6. Worked Step-by-Step Calculation Examples
  • Worked Example 6.1: Spore Trap Airborne Concentration & Trace Analysis

Problem: An industrial hygienist collects a non-viable spore trap sample using an Air-O-Cell cassette operated at a calibrated flow rate of 15.0 L/min for 10 minutes in a corporate boardroom. The analytical laboratory analyzes 100% of the impaction trace (trace area = 14.4 mm²) under 1000× magnification and counts 48 conidia of Aspergillus/Penicillium-like spores and 6 conidia of Stachybotrys chartarum .

Calculate the total air volume sampled in cubic meters (m³).

Calculate the airborne concentration of each fungal category in spores/m³.

Solution Steps:

Calculate total sampled air volume (V): V = Q × t = 15.0 L/min × 10 min = 150.0 Liters V = Q \times t = 15.0\text{ L/min} \times 10\text{ min} = 150.0\text{ Liters} V = Q × t = 15.0 L/min × 10 min = 150.0 Liters V = 150.0 L 1 , 000 L/m 3 = 0.150 m 3 V = \frac{150.0\text{ L}}{1,000\text{ L/m}^3} = 0.150\text{ m}^3 V = 1 , 000 L/m 3 150.0 L ​ = 0.150 m 3

Calculate airborne concentration (C): C = Raw Spore Count Volume in m 3 C = \frac{\text{Raw Spore Count}}{\text{Volume in m}^3} C = Volume in m 3 Raw Spore Count ​

For Aspergillus/Penicillium-like : C Asp/Pen = 48 spores 0.150 m 3 = 320 spores/m 3 C_{\text{Asp/Pen}} = \frac{48\text{ spores}}{0.150\text{ m}^3} = 320\text{ spores/m}^3 C Asp/Pen ​ = 0.150 m 3 48 spores ​ = 320 spores/m 3

For Stachybotrys chartarum : C Stachybotrys = 6 spores 0.150 m 3 = 40 spores/m 3 C_{\text{Stachybotrys}} = \frac{6\text{ spores}}{0.150\text{ m}^3} = 40\text{ spores/m}^3 C Stachybotrys ​ = 0.150 m 3 6 spores ​ = 40 spores/m 3

Result: The room air contains 320 spores/m³ of Aspergillus/Penicillium-like and 40 spores/m³ of Stachybotrys chartarum . Even at 40 spores/m³, the presence of Stachybotrys indicates active hydrophilic water damage within the building envelope.

Worked Example 6.2: Culturable Andersen N6 Positive-Hole Correction Calculation

Problem: An Andersen N6 single-stage viable impactor (400 holes) is operated at 28.3 L/min for 3.0 minutes onto a Malt Extract Agar plate. Following 5 days of incubation at 25°C, the laboratory counts r = 72 raw colonies on the agar surface.

Calculate the statistically corrected colony count (C) using the Macher approximation formula: C = 400 · ln(400/(400 - r)).

Calculate the airborne culturable fungal concentration in CFU/m³.

Solution Steps:

Calculate corrected colony count (C): C = 400 ⋅ ln ⁡ ( 400 400 − 72 ) = 400 ⋅ ln ⁡ ( 400 328 ) = 400 ⋅ ln ⁡ ( 1.21951 ) C = 400 \cdot \ln\left(\frac{400}{400 - 72}\right) = 400 \cdot \ln\left(\frac{400}{328}\right) = 400 \cdot \ln(1.21951) C = 400 ⋅ ln ( 400 − 72 400 ​ ) = 400 ⋅ ln ( 328 400 ​ ) = 400 ⋅ ln ( 1.21951 ) C = 400 ⋅ 0.19845 = 79.38 ≈ 79.4 Corrected CFUs C = 400 \cdot 0.19845 = 79.38 \approx 79.4\text{ Corrected CFUs} C = 400 ⋅ 0.19845 = 79.38 ≈ 79.4 Corrected CFUs

Calculate total sampled air volume (V): V = 28.3 L/min × 3.0 min = 84.9 Liters = 0.0849 m 3 V = 28.3\text{ L/min} \times 3.0\text{ min} = 84.9\text{ Liters} = 0.0849\text{ m}^3 V = 28.3 L/min × 3.0 min = 84.9 Liters = 0.0849 m 3

Calculate airborne concentration in CFU/m³: Concentration = 79.38 CFU 0.0849 m 3 = 934.98 CFU/m 3 ≈ 935 CFU/m 3 \text{Concentration} = \frac{79.38\text{ CFU}}{0.0849\text{ m}^3} = 934.98\text{ CFU/m}^3 \approx 935\text{ CFU/m}^3 Concentration = 0.0849 m 3 79.38 CFU ​ = 934.98 CFU/m 3 ≈ 935 CFU/m 3

Result: The statistically corrected viable fungal concentration is 935 CFU/m³ .