Study guide
8.2 Hazardous Air Pollutants, CEMS, and EPA Reference Methods
CIH Certified Industrial Hygienist Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: The CIH Exam and How to Use This Guide
1.1 CIH Exam Format, Scoring, and Test-Day Logistics 1.2 Eligibility, Application Windows, Fees, and Certification Maintenance 1.3 The BGC Blueprint, Subject Areas, and a Calculation-First Study Plan
2 Chapter 2: Basic Science & Calculations
2.1 Gas Laws and Vapor Calculations 2.2 Unit Conversions: ppm, mg/m³, and Standard Temperature/Pressure 2.3 Fluid Mechanics and Airflow Fundamentals
3 Chapter 3: Air Sampling & Instrumentation
3.1 Active and Passive Air Sampling Strategies 3.2 Particulate and Aerosol Sampling 3.3 Direct-Reading Instruments and Calibration
4 Chapter 4: Analytical Chemistry & Lab Methods
4.1 Gas Chromatography and Mass Spectrometry 4.2 High-Performance Liquid Chromatography and Ion Chromatography 4.3 Spectroscopy and Elemental Analysis 4.4 Gravimetric, Microscopy, and Wet Chemical Methods 4.5 Laboratory Quality Assurance, Chain of Custody, and Desorption Efficiency
5 Chapter 5: Biostatistics & Epidemiology
5.1 Lognormal Distributions and Exposure Data Statistics 5.2 Upper Confidence Limits (UCL95) and Compliance Decision Rules 5.3 Epidemiological Study Designs and Measures of Association 5.4 Sampling Strategy: Sample Size, Power, and Worker Selection
6 Chapter 6: Toxicology & Biological Monitoring
6.1 Dose-Response Relationships and Points of Departure 6.2 Toxicokinetics: Absorption, Distribution, Metabolism, and Elimination 6.3 Aerosol Deposition, Clearance, and Respiratory Tract Dosimetry 6.4 Hepatic, Renal, Neurologic, and Hematologic Target Organ Toxicity 6.5 Pulmonary Toxicology, Carcinogenicity, and Reproductive Hazards 6.6 OEL Frameworks, Classifications, and Excursion Limits 6.7 Chemical Mixtures and Extended Work-Shift OEL Adjustments 6.8 Biological Exposure Indices (BEIs) and Biomonitoring
7 Chapter 7: Biohazards & Indoor Environmental Quality
7.1 Mold, Fungi, and Microbial Contaminants 7.2 Infectious Agents, Bloodborne Pathogens, and Biosafety Levels 7.3 Indoor Environmental Quality (IEQ) Investigations 7.4 Sanitation, Potable Water, and Personal Hygiene Programs
8 Chapter 8: Community Exposure & Environmental Health
8.1 Clean Air Act Framework, NAAQS, and New Source Review 8.2 Hazardous Air Pollutants, CEMS, and EPA Reference Methods 8.3 Atmospheric Stability, Lapse Rates, and Plume Morphology 8.4 Gaussian Plume Modeling, Plume Rise, and Environmental Fate 8.5 HAZWOPER Scope, Mandates, and Training Tiers 8.6 Protection Levels, Site Zoning, Incident Command, and Decontamination 8.7 Water Pollution, Hazardous Waste, and Community Right-to-Know
9 Chapter 9: Health Risk Analysis & Hazard Communication
9.1 GHS Hazard Classification: Health and Physical Hazard Criteria 9.2 GHS Labels, Safety Data Sheets, and Trade Secret Rules 9.3 The AIHA Exposure Assessment Strategy and Similar Exposure Groups 9.4 Qualitative Exposure Profiling and the AIHA Risk Matrix 9.5 Quantitative Health Risk Characterization: HQ, HI, and ELCR 9.6 NIOSH Occupational Exposure Banding 9.7 Risk Communication and Reporting to Affected Parties
10 Chapter 10: Industrial Ventilation Principles & LEV Design
10.1 Elimination, Substitution, Isolation, Containment, and Process Change 10.2 LEV Hood Taxonomy and Capture Velocity Selection 10.3 Hood Airflow Equations, Entry Losses, and Hood Static Pressure 10.4 Particulate Transport Aerodynamics and Duct Sizing 10.5 Duct Friction, Fitting Losses, and System Balancing 10.6 Fan Categories and Pressure Dynamics Across the Fan 10.7 System Curves, the Fan Laws, and Density Corrections
11 Chapter 11: General Ventilation, Air Cleaning & Diagnostics
11.1 Dilution Ventilation Principles and Steady-State Modeling 11.2 Transient Purging and Air Distribution Geometry 11.3 Particulate Air Cleaning: Cyclones, Baghouses, Scrubbers, and ESPs 11.4 Gaseous Emission Control and Air Cleaner Selection 11.5 Ventilation System Troubleshooting and Testing
12 Chapter 12: Noise Measurement & Hearing Conservation
12.1 Acoustic Physics and Decibel Mathematics 12.2 Sound Propagation, Octave Bands, and Frequency Weighting 12.3 Noise Dose Metrics and OSHA versus ACGIH Criteria 12.4 Exchange Rates, Extended Shifts, and Dosimetry Field Protocols 12.5 Engineering Noise Controls and Hearing Protector Attenuation 12.6 Hearing Conservation Programs and Standard Threshold Shifts 12.7 Hand-Arm and Whole-Body Vibration
13 Chapter 13: Thermal Stress Assessment & Control
13.1 Wet Bulb Globe Temperature (WBGT) and Heat Stress Indices 13.2 Heat-Related Disorders, Acclimatization, and Work/Rest Regimens 13.3 Cold Stress Evaluation and Wind Chill
14 Chapter 14: Ionizing Radiation Protection
14.1 Ionizing Radiation Physics and Radioactive Decay Kinetics 14.2 Radiation Units, Radiobiology, and Health Effects 14.3 ALARA, Stay-Time, and the Inverse Square Law 14.4 Shielding Physics, Material Selection, and Gamma Constants 14.5 Radiation Detection Instruments and Spectrometry 14.6 Personnel Dosimetry, Dose Limits, and Contamination Surveys
15 Chapter 15: Non-Ionizing Radiation & Laser Safety
15.1 The Non-Ionizing Spectrum and Static/ELF Field Exposures 15.2 Radiofrequency and Microwave Exposure: SAR, Standards, and Surveys 15.3 Ultraviolet, Visible, and Infrared Radiation Hazards 15.4 Laser Safety Classifications and Optical Density Calculations 15.5 Illumination, Lighting Design, and Visual Performance
16 Chapter 16: Non-Engineering Controls & Personal Protective Equipment
16.1 Respiratory Protection Programs and Assigned Protection Factors 16.2 Maximum Use Concentration, Oxygen Deficiency, and Breathing Air 16.3 Particulate Filters, Sorbent Cartridges, and Change Schedules 16.4 Respirator Fit Testing Protocols 16.5 Chemical Protective Clothing and Dermal Exposure Control
17 Chapter 17: Ergonomics & Workstation Design
17.1 Soft-Tissue Biomechanics and WMSD Pathophysiology 17.2 Ergonomic Risk Factors and Their Interaction Effects 17.3 The Revised NIOSH Lifting Equation 17.4 RULA, REBA, the Strain Index, and the ACGIH HAL TLV 17.5 Anthropometry and Workstation Geometry 17.6 VDT Workstations, Hand Tool Design, and Administrative Ergonomics
18 Chapter 18: Work Environments & Industrial Processes
18.1 Welding Fume Emissions, Metal Fume Fever, and Cr(VI)/Manganese Toxicology 18.2 Foundry Operations and Hot Work Fire Prevention 18.3 Vapor Degreasing, Pickling, Electroplating, and Cyanide Baths 18.4 Spray Coatings, Isocyanates, and Semiconductor Manufacturing 18.5 Confined Spaces and High-Hazard Industrial Operations 18.6 Asbestos, Lead, and Silica: Regulated Substance Programs 18.7 Abrasive Blasting and Surface Preparation
19 Chapter 19: IH Program Management & Professional Ethics
19.1 The BGC Code of Ethics: Canons and Enforcement 19.2 Professional Liability, Standard of Care, and Expert Testimony 19.3 Occupational Health & Safety Management Systems (ISO 45001, ANSI Z10) 19.4 Exposure Records Access and Medical Surveillance 19.5 OSHA Injury and Illness Recordkeeping and Enforcement
8.2 Hazardous Air Pollutants, CEMS, and EPA Reference Methods
Key Takeaways Explain This Topic AI
Hazardous air pollutants are regulated under Section 112 by technology-based NESHAP standards rather than by ambient concentration limits.
A major HAP source emits 10 tons per year of any single HAP or 25 tons per year of any combination, and must meet Maximum Achievable Control Technology standards.
Continuous emission monitoring systems provide the compliance record for many stack sources, with relative accuracy test audits verifying them against reference methods.
EPA Methods 1 through 5 form a fixed sequence: traverse point selection, velocity by S-type pitot, molecular weight by Orsat, moisture content, and finally isokinetic particulate sampling — and Method 5 is invalid unless sampling is isokinetic within about 10%.
Last updated: August 2026
Hazardous Air Pollutants, CEMS, and EPA Reference Methods
NAAQS govern six ubiquitous pollutants at ambient monitors. A separate part of the Clean Air Act governs the far larger list of hazardous air pollutants at the stack, which is where continuous emission monitoring and the EPA reference test methods come in.
1. Hazardous Air Pollutants (HAPs) and NESHAP (Section 112)
Unlike criteria pollutants regulated by ambient concentration limits, toxic air contaminants are controlled under CAA Section 112 through source-specific emission standards.
Statutory List of HAPs
The 1990 CAA Amendments established a statutory list of 189 hazardous air pollutants (subsequently revised to 187 HAPs , including benzene, asbestos, vinyl chloride, mercury, polychlorinated biphenyls, methylene chloride, and formaldehydes). HAPs are substances known or suspected to cause cancer, genetic mutations, neurotoxicity, or reproductive harm.
Maximum Achievable Control Technology (MACT)
EPA issues National Emission Standards for Hazardous Air Pollutants (NESHAP) based on technology performance:
Major Source Threshold: Any stationary source that emits or has the potential to emit ≥ 10 tons/year of any single HAP or ≥ 25 tons/year of any combination of HAPs.
MACT Floor for Existing Sources: The average emission limitation achieved by the top 12% of best-performing existing sources in that industrial category.
MACT Floor for New Sources: The emission control achieved in practice by the single best-controlled similar source.
Risk and Technology Review (RTR): Eight years after MACT promulgation, EPA conducts a statutory residual risk assessment. If residual cancer risk to the most exposed individual exceeds 1 in 10⁶ (10⁻⁶) , EPA must implement more stringent health-based standards.
2. Stationary Source Continuous Emission Monitoring Systems (CEMS)
Continuous Emission Monitoring Systems (CEMS) provide real-time, uninterrupted measurement of stack gas effluent concentrations (e.g., SO2, NOx, CO, CO2, O2, total VOCs) and volumetric flow rates.
CEMS Architecture
Sample Extraction / Conditioning Interface: Heated sample probe, heated Teflon sample line (> 120°C to prevent acid gas moisture condensation), chiller/dryer to remove water vapor, particulate filters.
Analytical Gas Analyzers:
SO2 & NOx: Non-Dispersive Ultraviolet (NDUV) or Chemiluminescence (for NOx via reaction with ozone: NO + O3 → NO2(*) + hν).
CO & CO2: Non-Dispersive Infrared (NDIR) spectroscopy based on Beer-Lambert infrared light absorption.
O2 Diluent: Zirconium oxide (ZrO2) electrochemical cell or paramagnetic cell.
Data Acquisition and Handling System (DAHS): Logs raw data, performs temperature/pressure/moisture corrections, and computes 1-hour and rolling compliance averages.
Quality Assurance and Performance Specifications (40 CFR Part 60 / Part 75)
Daily Calibration Drift (CD) Test: Zero and span calibration gases injected directly at the probe tip daily. Drift must not exceed ≤ 2.5% of span value.
Relative Accuracy Test Audit (RATA): An annual or semi-annual comprehensive audit comparing CEMS output against concurrent manual EPA Reference Method testing across a minimum of 9 test runs: RA = ∣ d ˉ ∣ + ∣ CC ∣ RM ‾ × 100 % \text{RA} = \frac{|\bar{d}| + |\text{CC}|}{\overline{\text{RM}}} \times 100\% RA = RM ∣ d ˉ ∣ + ∣ CC ∣ × 100%
Where |d̄| is the mean difference between reference method and CEMS, |CC| is the 95% confidence coefficient, and RM-bar is the average reference method value. Regulatory compliance requires RA ≤ 10.0% (or ≤ 20.0% under Part 60 general applications).
3. EPA Stationary Source Reference Methods (Methods 1–5)
EPA 40 CFR Part 60 Appendix A details manual reference methods for stack testing: Method 1: Traverse Point Selection ──► 8 duct diameters downstream / 2 upstream from flow disturbances
- │
- Method 2: Stack Gas Velocity & Flow ─► Type S Pitot Tube + differential manometer (Δp)
- │
- Method 3/3A: Molecular Weight & O2/CO2► Orsat chemical absorption or NDIR/paramagnetic instrumental
- │
- Method 4: Stack Gas Moisture Content ─► Chilled impinger condensation train (volumetric/gravimetric)
- │
- Method 5: Isokinetic Particulate ────► Heated probe + filter (248°F) + isokinetic nozzle control
- EPA Method 1: Sample and Velocity Traverses for Stationary Sources
Selects sampling traverse point locations across the stack cross-section.
Ideal Criteria: Sampling location at least 8 duct diameters downstream and 2 duct diameters upstream from any flow disturbance (bend, expansion, contraction, fan, or damper).
Minimum Acceptable Criteria: At least 2 diameters downstream and 0.5 diameters upstream (requires an increased number of traverse points, up to 48 points for circular stacks).
EPA Method 2: Determination of Stack Gas Velocity and Volumetric Flow Rate
Measures gas velocity pressure using a calibrated Type S Pitot Tube (baseline coefficient Cp ≈ 0.84) and inclined manometer: v s = K p ⋅ C p ⋅ Δ p ⋅ T s P s ⋅ M s v_s = K_p \cdot C_p \cdot \sqrt{\Delta p} \cdot \sqrt{\frac{T_s}{P_s \cdot M_s}} v s = K p ⋅ C p ⋅ Δ p ⋅ P s ⋅ M s T s
Where:
- vs = Stack gas velocity (m/s or ft/sec)
- Kp = Velocity equation constant (34.97 m/s · g/(g-mole·K) · mm Hg/mm H2O or 85.49 ft/s in English units)
- Cp = Pitot tube coefficient (dimensionless)
- Δ p = Velocity head differential pressure (in. H2O or mm H2O)
- Ts = Absolute stack temperature (K or °R)
- Ps = Absolute stack pressure (mm Hg or in. Hg)
- Ms = Wet molecular weight of stack gas (g/g-mole or lb/lb-mole)
- EPA Method 3 / 3A: Gas Analysis for Molecular Weight
Measures concentrations of O2, CO2, and CO to compute dry stack molecular weight (Md): M d = ( 0.440 × % CO 2 ) + ( 0.320 × % O 2 ) + [ 0.280 × ( % N 2 + % CO ) ] M_d = (0.440 \times \%\text{CO}_2) + (0.320 \times \%\text{O}_2) + [0.280 \times (\%\text{N}_2 + \%\text{CO})] M d = ( 0.440 × % CO 2 ) + ( 0.320 × % O 2 ) + [ 0.280 × ( % N 2 + % CO )]
Wet molecular weight (Ms) adjusts for stack moisture content (Bws): M s = M d ⋅ ( 1 − B w s ) + ( 18.0 ⋅ B w s ) M_s = M_d \cdot (1 - B_{ws}) + (18.0 \cdot B_{ws}) M s = M d ⋅ ( 1 − B w s ) + ( 18.0 ⋅ B w s )
EPA Method 4: Stack Gas Moisture Content
Gas is extracted through a chilled condenser/impinger train. Moisture content (Bws) is calculated from condensed water volume (Vlc) and dry metered gas volume (V(m(std))): B w s = V w ( s t d ) V m ( s t d ) + V w ( s t d ) B_{ws} = \frac{V_{w(std)}}{V_{m(std)} + V_{w(std)}} B w s = V m ( s t d ) + V w ( s t d ) V w ( s t d )
EPA Method 5: Determination of Particulate Matter Emissions (Isokinetic Sampling)
Method 5 extracts particulate matter gravimetrically through a precision nozzle, heated probe, and heated filter maintained at 120 ± 14°C (248 ± 25°F) , followed by a chilled impinger train. ┌─────────────────────────────┐
- │ Isokinetic Sampling Physics │
- └──────────────┬──────────────┘
- │
- ┌─────────────────────────────────────────┼─────────────────────────────────────────┐
- ▼ ▼ ▼
- ┌──────────────────────────────┐ ┌──────────────────────────────┐ ┌──────────────────────────────┐
- │ Isokinetic (Vn = Vs) │ │ Under-Isokinetic (Vn < Vs)│ │ Over-Isokinetic (Vn > Vs) │
- ├──────────────────────────────┤ ├──────────────────────────────┤ ├──────────────────────────────┤
- │ • Streamlines enter straight │ │ • Gas streamlines diverge │ │ • Gas streamlines converge │
- │ • True particulate mass │ │ • Large particles over-enter │ │ • Large particles under-enter│
- │ • 100% accurate measurement │ │ • Biased HIGH (False High) │ │ • Biased LOW (False Low) │
- └──────────────────────────────┘ └──────────────────────────────┘ └──────────────────────────────┘
- The Isokinetic Sampling Principle
Isokinetic Condition (vn = vs): The linear gas velocity entering the nozzle probe (vn) equals the stack gas velocity approaching the nozzle (vs). Particulates of all sizes enter proportionally without streamline deflection.
Under-Isokinetic (vn < vs, Sampling Too Slowly, I < 90%): Gas streamlines diverge around the nozzle opening. Heavy particles with high aerodynamic inertia cross the divergent streamlines and enter the nozzle, resulting in an artificially high (falsely elevated) measured mass concentration .
Over-Isokinetic (vn > vs, Sampling Too Fast, I > 110%): Gas streamlines converge into the nozzle opening. Heavy particles resist curvature due to inertia and travel past the nozzle rim, resulting in an artificially low (falsely depressed) measured mass concentration .
Acceptable Regulatory Window: The Isokinetic Variation Percentage (I) must fall within 90% ≤ I ≤ 110% (100 ± 10%) for a test run to be legally valid.
Isokinetic Variation Equation I = 100 ⋅ T s ⋅ [ K 3 ⋅ V l c + ( V m ⋅ Y / T m ) ⋅ ( P b a r + Δ H / 13.6 ) ] θ ⋅ v s ⋅ P s ⋅ A n I = \frac{100 \cdot T_s \cdot [K_3 \cdot V_{lc} + (V_m \cdot Y / T_m) \cdot (P_{bar} + \Delta H / 13.6)]}{\theta \cdot v_s \cdot P_s \cdot A_n} I = θ ⋅ v s ⋅ P s ⋅ A n 100 ⋅ T s ⋅ [ K 3 ⋅ V l c + ( V m ⋅ Y / T m ) ⋅ ( P ba r + Δ H /13.6 )]
Where:
- I = Percent isokinetic variation (must be 90-110%)
- Vlc = Total volume of liquid condensed in impingers (mL)
- Vm = Dry gas meter volume recorded (dcf or dcm)
- Y = Dry gas meter calibration factor
- Tm = Absolute temperature at dry gas meter (°R or K)
- Pbar = Barometric pressure (in. Hg or mm Hg)
- Δ H = Average pressure differential across meter orifice (in. H2O)
- θ = Total elapsed sampling duration (minutes)
- An = Cross-sectional area of sampling nozzle (ft² or m²)
- 4. Worked Step-by-Step Calculation Examples
- Worked Example 7.1: EPA Method 5 Isokinetic Variation (I%) Calculation
Problem: An environmental compliance audit tests a coal-fired boiler stack using EPA Method 5. The field test run yields the following data:
- Stack gas velocity (vs): 50.0 ft/s
- Sampling duration (θ): 60.0 minutes
- Stack temperature (Ts): 240°F = 700 R
- Stack pressure (Ps): 29.80 in. Hg
- Standard dry gas volume sampled (V(m(std))): 45.00 dscf
- Stack moisture content fraction (Bws): 0.0400 (4.0% moisture)
- Sampling nozzle inner diameter (Dn): 0.250 inches
- Standard conditions: Tstd = 528 R, Pstd = 29.92 in. Hg
Verify whether this sampling run meets the EPA Method 5 isokinetic acceptance criterion (90% ≤ I ≤ 110%).
Solution Steps:
Calculate Nozzle Cross-Sectional Area (An): D n = 0.250 in 12 in/ft = 0.020833 ft D_n = \frac{0.250\text{ in}}{12\text{ in/ft}} = 0.020833\text{ ft} D n = 12 in/ft 0.250 in = 0.020833 ft A n = π 4 ⋅ D n 2 = π 4 ⋅ ( 0.020833 ft ) 2 = 3.4088 × 10 − 4 ft 2 A_n = \frac{\pi}{4} \cdot D_n^2 = \frac{\pi}{4} \cdot (0.020833\text{ ft})^2 = 3.4088 \times 10^{-4}\text{ ft}^2 A n = 4 π ⋅ D n 2 = 4 π ⋅ ( 0.020833 ft ) 2 = 3.4088 × 1 0 − 4 ft 2
Apply the Standard Isokinetic Formula: I = 100 ⋅ V m ( s t d ) ⋅ T s ⋅ P s t d T s t d ⋅ P s ⋅ v s ⋅ A n ⋅ θ ⋅ 60 ⋅ ( 1 − B w s ) I = \frac{100 \cdot V_{m(std)} \cdot T_s \cdot P_{std}}{T_{std} \cdot P_s \cdot v_s \cdot A_n \cdot \theta \cdot 60 \cdot (1 - B_{ws})} I = T s t d ⋅ P s ⋅ v s ⋅ A n ⋅ θ ⋅ 60 ⋅ ( 1 − B w s ) 100 ⋅ V m ( s t d ) ⋅ T s ⋅ P s t d
Compute Numerator and Denominator: Numerator = 100 × 45.00 dscf × 700 R × 29.92 in. Hg = 94 , 248 , 000 \text{Numerator} = 100 \times 45.00\text{ dscf} \times 700\text{ R} \times 29.92\text{ in. Hg} = 94,248,000 Numerator = 100 × 45.00 dscf × 700 R × 29.92 in. Hg = 94 , 248 , 000 Denominator = 528 × 29.80 × 50.0 × ( 3.4088 × 10 − 4 ) × 60 × 60 × ( 1 − 0.0400 ) \text{Denominator} = 528 \times 29.80 \times 50.0 \times (3.4088 \times 10^{-4}) \times 60 \times 60 \times (1 - 0.0400) Denominator = 528 × 29.80 × 50.0 × ( 3.4088 × 1 0 − 4 ) × 60 × 60 × ( 1 − 0.0400 ) Denominator = 528 × 29.80 × 50.0 × 0.00034088 × 3600 × 0.9600 = 92 , 624 , 357 \text{Denominator} = 528 \times 29.80 \times 50.0 \times 0.00034088 \times 3600 \times 0.9600 = 92,624,357 Denominator = 528 × 29.80 × 50.0 × 0.00034088 × 3600 × 0.9600 = 92 , 624 , 357
Calculate Percent Isokinetic (I): I = 94 , 248 , 000 92 , 624 , 357 = 101.75 % ≈ 101.8 % I = \frac{94,248,000}{92,624,357} = 101.75\% \approx 101.8\% I = 92 , 624 , 357 94 , 248 , 000 = 101.75% ≈ 101.8%
Result: The isokinetic percentage is 101.8% , which falls well within the required regulatory window of 90% ≤ I ≤ 110% . The test run is valid.
Worked Example 7.2: Particulate Concentration and Mass Emission Rate
Problem: From the Method 5 test in Example 7.1, the total gravimetric particulate catch recovered from the probe wash and filter is mn = 45.0 mg (0.0450 g). The stack has a circular diameter of 6.0 ft with a volumetric stack gas flow rate of Qstd = 22,000 dscfm (dry standard cubic feet per minute).
Calculate the particulate concentration in grains per dry standard cubic foot (gr/dscf) and in milligrams per dry standard cubic meter (mg/dscm). (1 lb = 7,000 grains; 1 grain = 64.7989 mg; 1 dscm = 35.3147 dscf).
Calculate the particulate mass emission rate (E) in pounds per hour (lb/hr).
Solution Steps:
Calculate Particulate Concentration (cs):
Convert mass in mg to grains: Mass in grains = 45.0 mg 64.7989 mg/gr = 0.69446 grains \text{Mass in grains} = \frac{45.0\text{ mg}}{64.7989\text{ mg/gr}} = 0.69446\text{ grains} Mass in grains = 64.7989 mg/gr 45.0 mg = 0.69446 grains
In gr/dscf: c s = 0.69446 grains 45.00 dscf = 0.01543 gr/dscf c_s = \frac{0.69446\text{ grains}}{45.00\text{ dscf}} = 0.01543\text{ gr/dscf} c s = 45.00 dscf 0.69446 grains = 0.01543 gr/dscf
In mg/dscm: V m ( s t d ) ( m 3 ) = 45.00 dscf 35.3147 dscf/m 3 = 1.27426 dscm V_{m(std)} (\text{m}^3) = \frac{45.00\text{ dscf}}{35.3147\text{ dscf/m}^3} = 1.27426\text{ dscm} V m ( s t d ) ( m 3 ) = 35.3147 dscf/m 3 45.00 dscf = 1.27426 dscm c s = 45.0 mg 1.27426 dscm = 35.315 mg/dscm ≈ 35.3 mg/dscm c_s = \frac{45.0\text{ mg}}{1.27426\text{ dscm}} = 35.315\text{ mg/dscm} \approx 35.3\text{ mg/dscm} c s = 1.27426 dscm 45.0 mg = 35.315 mg/dscm ≈ 35.3 mg/dscm
Calculate Mass Emission Rate (E): E = c s ( gr/dscf ) × Q s t d ( dscfm ) × 60 min/hr 7 , 000 gr/lb E = c_s (\text{gr/dscf}) \times Q_{std} (\text{dscfm}) \times \frac{60\text{ min/hr}}{7,000\text{ gr/lb}} E = c s ( gr/dscf ) × Q s t d ( dscfm ) × 7 , 000 gr/lb 60 min/hr E = 0.015432 gr/dscf × 22 , 000 dscfm × 60 7 , 000 E = 0.015432\text{ gr/dscf} \times 22,000\text{ dscfm} \times \frac{60}{7,000} E = 0.015432 gr/dscf × 22 , 000 dscfm × 7 , 000 60 E = 20 , 370.24 7 , 000 = 2.910 lb/hr ≈ 2.91 lb/hr E = \frac{20,370.24}{7,000} = 2.910\text{ lb/hr} \approx 2.91\text{ lb/hr} E = 7 , 000 20 , 370.24 = 2.910 lb/hr ≈ 2.91 lb/hr
Result: The particulate concentration is 0.0154 gr/dscf (35.3 mg/dscm), generating a mass emission rate of 2.91 lb/hr .