Study guide
8.7 Water Pollution, Hazardous Waste, and Community Right-to-Know
CIH Certified Industrial Hygienist Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: The CIH Exam and How to Use This Guide
1.1 CIH Exam Format, Scoring, and Test-Day Logistics 1.2 Eligibility, Application Windows, Fees, and Certification Maintenance 1.3 The BGC Blueprint, Subject Areas, and a Calculation-First Study Plan
2 Chapter 2: Basic Science & Calculations
2.1 Gas Laws and Vapor Calculations 2.2 Unit Conversions: ppm, mg/m³, and Standard Temperature/Pressure 2.3 Fluid Mechanics and Airflow Fundamentals
3 Chapter 3: Air Sampling & Instrumentation
3.1 Active and Passive Air Sampling Strategies 3.2 Particulate and Aerosol Sampling 3.3 Direct-Reading Instruments and Calibration
4 Chapter 4: Analytical Chemistry & Lab Methods
4.1 Gas Chromatography and Mass Spectrometry 4.2 High-Performance Liquid Chromatography and Ion Chromatography 4.3 Spectroscopy and Elemental Analysis 4.4 Gravimetric, Microscopy, and Wet Chemical Methods 4.5 Laboratory Quality Assurance, Chain of Custody, and Desorption Efficiency
5 Chapter 5: Biostatistics & Epidemiology
5.1 Lognormal Distributions and Exposure Data Statistics 5.2 Upper Confidence Limits (UCL95) and Compliance Decision Rules 5.3 Epidemiological Study Designs and Measures of Association 5.4 Sampling Strategy: Sample Size, Power, and Worker Selection
6 Chapter 6: Toxicology & Biological Monitoring
6.1 Dose-Response Relationships and Points of Departure 6.2 Toxicokinetics: Absorption, Distribution, Metabolism, and Elimination 6.3 Aerosol Deposition, Clearance, and Respiratory Tract Dosimetry 6.4 Hepatic, Renal, Neurologic, and Hematologic Target Organ Toxicity 6.5 Pulmonary Toxicology, Carcinogenicity, and Reproductive Hazards 6.6 OEL Frameworks, Classifications, and Excursion Limits 6.7 Chemical Mixtures and Extended Work-Shift OEL Adjustments 6.8 Biological Exposure Indices (BEIs) and Biomonitoring
7 Chapter 7: Biohazards & Indoor Environmental Quality
7.1 Mold, Fungi, and Microbial Contaminants 7.2 Infectious Agents, Bloodborne Pathogens, and Biosafety Levels 7.3 Indoor Environmental Quality (IEQ) Investigations 7.4 Sanitation, Potable Water, and Personal Hygiene Programs
8 Chapter 8: Community Exposure & Environmental Health
8.1 Clean Air Act Framework, NAAQS, and New Source Review 8.2 Hazardous Air Pollutants, CEMS, and EPA Reference Methods 8.3 Atmospheric Stability, Lapse Rates, and Plume Morphology 8.4 Gaussian Plume Modeling, Plume Rise, and Environmental Fate 8.5 HAZWOPER Scope, Mandates, and Training Tiers 8.6 Protection Levels, Site Zoning, Incident Command, and Decontamination 8.7 Water Pollution, Hazardous Waste, and Community Right-to-Know
9 Chapter 9: Health Risk Analysis & Hazard Communication
9.1 GHS Hazard Classification: Health and Physical Hazard Criteria 9.2 GHS Labels, Safety Data Sheets, and Trade Secret Rules 9.3 The AIHA Exposure Assessment Strategy and Similar Exposure Groups 9.4 Qualitative Exposure Profiling and the AIHA Risk Matrix 9.5 Quantitative Health Risk Characterization: HQ, HI, and ELCR 9.6 NIOSH Occupational Exposure Banding 9.7 Risk Communication and Reporting to Affected Parties
10 Chapter 10: Industrial Ventilation Principles & LEV Design
10.1 Elimination, Substitution, Isolation, Containment, and Process Change 10.2 LEV Hood Taxonomy and Capture Velocity Selection 10.3 Hood Airflow Equations, Entry Losses, and Hood Static Pressure 10.4 Particulate Transport Aerodynamics and Duct Sizing 10.5 Duct Friction, Fitting Losses, and System Balancing 10.6 Fan Categories and Pressure Dynamics Across the Fan 10.7 System Curves, the Fan Laws, and Density Corrections
11 Chapter 11: General Ventilation, Air Cleaning & Diagnostics
11.1 Dilution Ventilation Principles and Steady-State Modeling 11.2 Transient Purging and Air Distribution Geometry 11.3 Particulate Air Cleaning: Cyclones, Baghouses, Scrubbers, and ESPs 11.4 Gaseous Emission Control and Air Cleaner Selection 11.5 Ventilation System Troubleshooting and Testing
12 Chapter 12: Noise Measurement & Hearing Conservation
12.1 Acoustic Physics and Decibel Mathematics 12.2 Sound Propagation, Octave Bands, and Frequency Weighting 12.3 Noise Dose Metrics and OSHA versus ACGIH Criteria 12.4 Exchange Rates, Extended Shifts, and Dosimetry Field Protocols 12.5 Engineering Noise Controls and Hearing Protector Attenuation 12.6 Hearing Conservation Programs and Standard Threshold Shifts 12.7 Hand-Arm and Whole-Body Vibration
13 Chapter 13: Thermal Stress Assessment & Control
13.1 Wet Bulb Globe Temperature (WBGT) and Heat Stress Indices 13.2 Heat-Related Disorders, Acclimatization, and Work/Rest Regimens 13.3 Cold Stress Evaluation and Wind Chill
14 Chapter 14: Ionizing Radiation Protection
14.1 Ionizing Radiation Physics and Radioactive Decay Kinetics 14.2 Radiation Units, Radiobiology, and Health Effects 14.3 ALARA, Stay-Time, and the Inverse Square Law 14.4 Shielding Physics, Material Selection, and Gamma Constants 14.5 Radiation Detection Instruments and Spectrometry 14.6 Personnel Dosimetry, Dose Limits, and Contamination Surveys
15 Chapter 15: Non-Ionizing Radiation & Laser Safety
15.1 The Non-Ionizing Spectrum and Static/ELF Field Exposures 15.2 Radiofrequency and Microwave Exposure: SAR, Standards, and Surveys 15.3 Ultraviolet, Visible, and Infrared Radiation Hazards 15.4 Laser Safety Classifications and Optical Density Calculations 15.5 Illumination, Lighting Design, and Visual Performance
16 Chapter 16: Non-Engineering Controls & Personal Protective Equipment
16.1 Respiratory Protection Programs and Assigned Protection Factors 16.2 Maximum Use Concentration, Oxygen Deficiency, and Breathing Air 16.3 Particulate Filters, Sorbent Cartridges, and Change Schedules 16.4 Respirator Fit Testing Protocols 16.5 Chemical Protective Clothing and Dermal Exposure Control
17 Chapter 17: Ergonomics & Workstation Design
17.1 Soft-Tissue Biomechanics and WMSD Pathophysiology 17.2 Ergonomic Risk Factors and Their Interaction Effects 17.3 The Revised NIOSH Lifting Equation 17.4 RULA, REBA, the Strain Index, and the ACGIH HAL TLV 17.5 Anthropometry and Workstation Geometry 17.6 VDT Workstations, Hand Tool Design, and Administrative Ergonomics
18 Chapter 18: Work Environments & Industrial Processes
18.1 Welding Fume Emissions, Metal Fume Fever, and Cr(VI)/Manganese Toxicology 18.2 Foundry Operations and Hot Work Fire Prevention 18.3 Vapor Degreasing, Pickling, Electroplating, and Cyanide Baths 18.4 Spray Coatings, Isocyanates, and Semiconductor Manufacturing 18.5 Confined Spaces and High-Hazard Industrial Operations 18.6 Asbestos, Lead, and Silica: Regulated Substance Programs 18.7 Abrasive Blasting and Surface Preparation
19 Chapter 19: IH Program Management & Professional Ethics
19.1 The BGC Code of Ethics: Canons and Enforcement 19.2 Professional Liability, Standard of Care, and Expert Testimony 19.3 Occupational Health & Safety Management Systems (ISO 45001, ANSI Z10) 19.4 Exposure Records Access and Medical Surveillance 19.5 OSHA Injury and Illness Recordkeeping and Enforcement
8.7 Water Pollution, Hazardous Waste, and Community Right-to-Know
Key Takeaways Explain This Topic AI
RCRA regulates hazardous waste cradle to grave; generator status is large (1,000 kg/month or more), small (100 to less than 1,000 kg/month), or very small (100 kg/month or less).
A waste is hazardous either because it is listed (F, K, P, or U lists) or because it exhibits ignitability, corrosivity, reactivity, or toxicity by the TCLP.
CERCLA liability for contaminated sites is strict, joint and several, and retroactive, so a contributor of a small fraction can be liable for the entire cleanup.
EPCRA sections 302, 304, 311/312, and 313 govern emergency planning, release notification, chemical inventory reporting, and the Toxics Release Inventory respectively.
The Clean Water Act regulates point-source discharges through NPDES permits and indirect discharges to publicly owned treatment works through pretreatment standards.
Last updated: August 2026
Water Pollution, Hazardous Waste, and Community Right-to-Know
The BGC Community Exposure subject area covers "other IH-related environmental subjects such as emergency planning and response, water pollution, hazardous waste , and environmental fate and transport." The industrial hygienist is frequently the person who determines whether a waste stream is hazardous, whether a release is reportable, and what the community is told.
1. RCRA: Hazardous Waste Cradle to Grave
The Resource Conservation and Recovery Act (1976) governs the generation, transport, treatment, storage, and disposal of hazardous waste under Subtitle C. Its architecture is a chain of custody for waste.
Is it a hazardous waste?
A solid waste is hazardous if it is listed or if it exhibits a characteristic .
Listed wastes (four lists):
- List Meaning Example
- F Non-specific source wastes F001–F005 spent halogenated and non-halogenated solvents
- K Specific source wastes from named industries Wastewater treatment sludge from a named process
- P Acutely hazardous discarded commercial chemical products Sodium cyanide, many pesticides
- U Toxic discarded commercial chemical products Many laboratory solvents
Characteristic wastes (four characteristics):
Characteristic Code Criterion
Ignitability D001 Liquid with flash point below 60 °C (140 °F); also ignitable compressed gases, oxidisers, and certain solids
Corrosivity D002 Aqueous with pH ≤ 2.0 or ≥ 12.5, or corrodes steel faster than 6.35 mm/year at 55 °C
Reactivity D003 Unstable, reacts violently with water, generates toxic gas, or is a cyanide or sulphide bearing waste
Toxicity D004–D043 Leachate from the Toxicity Characteristic Leaching Procedure (TCLP) exceeds a listed limit
The TCLP simulates landfill leaching conditions. A solid that is safe to handle can still be a toxicity-characteristic waste if it leaches lead, cadmium, chromium, or an organic above the regulatory level — which is exactly how blast media, paint chips, and treated wood become hazardous waste.
Generator status
- Category Monthly generation On-site accumulation limit Accumulation time
- Very small quantity generator (VSQG) 100 kg or less 1,000 kg No time limit
Small quantity generator (SQG) more than 100 to less than 1,000 kg 6,000 kg 180 days (270 if transporting more than 200 miles)
Large quantity generator (LQG) 1,000 kg or more, or more than 1 kg of acute hazardous waste No limit 90 days
Generator status is determined monthly , so a single large clean-out can move a facility into a higher category for that month.
The manifest
Hazardous waste shipped off site travels under a Uniform Hazardous Waste Manifest , signed by the generator, each transporter, and the designated facility, with a copy returned to the generator. If the signed copy does not come back within 35 days, the generator must investigate; if it has not arrived within 45 days, an exception report goes to EPA. Generators must also meet satellite accumulation, container labelling and dating, weekly inspection, contingency planning, and personnel training requirements.
2. CERCLA: Superfund
The Comprehensive Environmental Response, Compensation, and Liability Act (1980) addresses abandoned and uncontrolled contaminated sites, rather than ongoing waste management.
Its defining feature is the liability scheme:
Strict — liability without proof of negligence or fault.
Joint and several — any one potentially responsible party can be held liable for the entire cleanup.
Retroactive — applies to disposal that was entirely lawful when it occurred.
Four classes of potentially responsible party: current owners and operators, owners and operators at the time of disposal, generators who arranged for disposal, and transporters who selected the disposal site.
Sites are scored using the Hazard Ranking System , and those scoring above the threshold are placed on the National Priorities List . Cleanup proceeds through remedial investigation and feasibility study, a record of decision, remedial design and action.
Release reporting: a release of a hazardous substance at or above its reportable quantity in a 24-hour period must be reported immediately to the National Response Center .
3. EPCRA: Community Right-to-Know
The Emergency Planning and Community Right-to-Know Act, enacted as SARA Title III in 1986 after the Bhopal disaster, has four reporting programmes that the exam expects you to distinguish by section number.
Section Programme Trigger Goes to
302 Emergency planning Extremely hazardous substance present above its threshold planning quantity State emergency response commission, local emergency planning committee
304 Emergency release notification Release of an extremely hazardous substance or CERCLA hazardous substance above its reportable quantity LEPC, SERC, and National Response Center
311/312 Chemical inventory reporting Chemicals requiring an SDS above threshold quantities Safety data sheets or a list (311) and annual Tier I/Tier II inventory (312) to LEPC, SERC, and fire department
313 Toxics Release Inventory Manufacture, process, or otherwise use a listed toxic chemical above threshold at a covered facility with 10 or more full-time employees Annual Form R to EPA and the state
Two memory hooks: 304 is the phone call made at the time of a release; 313 is the annual report of routine releases and transfers, due July 1 for the previous calendar year.
4. Clean Water Act and Drinking Water
Clean Water Act (1972). Its central prohibition is that no one may discharge a pollutant from a point source to waters of the United States without a permit.
NPDES permits authorise direct point-source discharges, imposing technology-based effluent limitations and, where necessary, water-quality-based limits derived from total maximum daily loads .
Pretreatment standards apply to indirect dischargers sending wastewater to a publicly owned treatment works, preventing pass-through of pollutants the plant cannot treat and interference with its biological processes. This is the programme most industrial facilities actually live under.
Stormwater discharges from industrial activity and construction sites require permit coverage and a stormwater pollution prevention plan.
Spill Prevention, Control, and Countermeasure (SPCC) plans under 40 CFR 112 are required for facilities storing oil above threshold quantities with a reasonable expectation of discharge to navigable waters.
Safe Drinking Water Act. Sets enforceable maximum contaminant levels (MCLs) for public water systems, set as close as feasible to the health-based, non-enforceable maximum contaminant level goals (MCLGs) . The Lead and Copper Rule uses an action level structure rather than an MCL — currently 15 µg/L for lead and 1.3 mg/L for copper at the 90th percentile of tap samples — because the source is distribution-system corrosion rather than the treatment plant. The 2024 Lead and Copper Rule Improvements lower the lead action level to 10 µg/L , but systems generally do not transition to that regime until November 1, 2027 , so 15 µg/L remains the operative action level in the meantime.
5. Why the Industrial Hygienist Owns This
The person who characterises a waste stream is usually the person who understands what is in it — a materials and process question before it is a regulatory one.
Reportable-quantity determinations happen under time pressure during an incident, and the immediate-notification clock is short.
Tier II inventories and TRI reports draw on the same chemical inventory that drives the hazard communication programme, so the data should be maintained once and used for both.
Community exposure questions on the exam frequently combine a release scenario with dispersion, reportable quantities, and notification obligations in a single item.