Study guide
14.6 Personnel Dosimetry, Dose Limits, and Contamination Surveys
CIH Certified Industrial Hygienist Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: The CIH Exam and How to Use This Guide
1.1 CIH Exam Format, Scoring, and Test-Day Logistics 1.2 Eligibility, Application Windows, Fees, and Certification Maintenance 1.3 The BGC Blueprint, Subject Areas, and a Calculation-First Study Plan
2 Chapter 2: Basic Science & Calculations
2.1 Gas Laws and Vapor Calculations 2.2 Unit Conversions: ppm, mg/m³, and Standard Temperature/Pressure 2.3 Fluid Mechanics and Airflow Fundamentals
3 Chapter 3: Air Sampling & Instrumentation
3.1 Active and Passive Air Sampling Strategies 3.2 Particulate and Aerosol Sampling 3.3 Direct-Reading Instruments and Calibration
4 Chapter 4: Analytical Chemistry & Lab Methods
4.1 Gas Chromatography and Mass Spectrometry 4.2 High-Performance Liquid Chromatography and Ion Chromatography 4.3 Spectroscopy and Elemental Analysis 4.4 Gravimetric, Microscopy, and Wet Chemical Methods 4.5 Laboratory Quality Assurance, Chain of Custody, and Desorption Efficiency
5 Chapter 5: Biostatistics & Epidemiology
5.1 Lognormal Distributions and Exposure Data Statistics 5.2 Upper Confidence Limits (UCL95) and Compliance Decision Rules 5.3 Epidemiological Study Designs and Measures of Association 5.4 Sampling Strategy: Sample Size, Power, and Worker Selection
6 Chapter 6: Toxicology & Biological Monitoring
6.1 Dose-Response Relationships and Points of Departure 6.2 Toxicokinetics: Absorption, Distribution, Metabolism, and Elimination 6.3 Aerosol Deposition, Clearance, and Respiratory Tract Dosimetry 6.4 Hepatic, Renal, Neurologic, and Hematologic Target Organ Toxicity 6.5 Pulmonary Toxicology, Carcinogenicity, and Reproductive Hazards 6.6 OEL Frameworks, Classifications, and Excursion Limits 6.7 Chemical Mixtures and Extended Work-Shift OEL Adjustments 6.8 Biological Exposure Indices (BEIs) and Biomonitoring
7 Chapter 7: Biohazards & Indoor Environmental Quality
7.1 Mold, Fungi, and Microbial Contaminants 7.2 Infectious Agents, Bloodborne Pathogens, and Biosafety Levels 7.3 Indoor Environmental Quality (IEQ) Investigations 7.4 Sanitation, Potable Water, and Personal Hygiene Programs
8 Chapter 8: Community Exposure & Environmental Health
8.1 Clean Air Act Framework, NAAQS, and New Source Review 8.2 Hazardous Air Pollutants, CEMS, and EPA Reference Methods 8.3 Atmospheric Stability, Lapse Rates, and Plume Morphology 8.4 Gaussian Plume Modeling, Plume Rise, and Environmental Fate 8.5 HAZWOPER Scope, Mandates, and Training Tiers 8.6 Protection Levels, Site Zoning, Incident Command, and Decontamination 8.7 Water Pollution, Hazardous Waste, and Community Right-to-Know
9 Chapter 9: Health Risk Analysis & Hazard Communication
9.1 GHS Hazard Classification: Health and Physical Hazard Criteria 9.2 GHS Labels, Safety Data Sheets, and Trade Secret Rules 9.3 The AIHA Exposure Assessment Strategy and Similar Exposure Groups 9.4 Qualitative Exposure Profiling and the AIHA Risk Matrix 9.5 Quantitative Health Risk Characterization: HQ, HI, and ELCR 9.6 NIOSH Occupational Exposure Banding 9.7 Risk Communication and Reporting to Affected Parties
10 Chapter 10: Industrial Ventilation Principles & LEV Design
10.1 Elimination, Substitution, Isolation, Containment, and Process Change 10.2 LEV Hood Taxonomy and Capture Velocity Selection 10.3 Hood Airflow Equations, Entry Losses, and Hood Static Pressure 10.4 Particulate Transport Aerodynamics and Duct Sizing 10.5 Duct Friction, Fitting Losses, and System Balancing 10.6 Fan Categories and Pressure Dynamics Across the Fan 10.7 System Curves, the Fan Laws, and Density Corrections
11 Chapter 11: General Ventilation, Air Cleaning & Diagnostics
11.1 Dilution Ventilation Principles and Steady-State Modeling 11.2 Transient Purging and Air Distribution Geometry 11.3 Particulate Air Cleaning: Cyclones, Baghouses, Scrubbers, and ESPs 11.4 Gaseous Emission Control and Air Cleaner Selection 11.5 Ventilation System Troubleshooting and Testing
12 Chapter 12: Noise Measurement & Hearing Conservation
12.1 Acoustic Physics and Decibel Mathematics 12.2 Sound Propagation, Octave Bands, and Frequency Weighting 12.3 Noise Dose Metrics and OSHA versus ACGIH Criteria 12.4 Exchange Rates, Extended Shifts, and Dosimetry Field Protocols 12.5 Engineering Noise Controls and Hearing Protector Attenuation 12.6 Hearing Conservation Programs and Standard Threshold Shifts 12.7 Hand-Arm and Whole-Body Vibration
13 Chapter 13: Thermal Stress Assessment & Control
13.1 Wet Bulb Globe Temperature (WBGT) and Heat Stress Indices 13.2 Heat-Related Disorders, Acclimatization, and Work/Rest Regimens 13.3 Cold Stress Evaluation and Wind Chill
14 Chapter 14: Ionizing Radiation Protection
14.1 Ionizing Radiation Physics and Radioactive Decay Kinetics 14.2 Radiation Units, Radiobiology, and Health Effects 14.3 ALARA, Stay-Time, and the Inverse Square Law 14.4 Shielding Physics, Material Selection, and Gamma Constants 14.5 Radiation Detection Instruments and Spectrometry 14.6 Personnel Dosimetry, Dose Limits, and Contamination Surveys
15 Chapter 15: Non-Ionizing Radiation & Laser Safety
15.1 The Non-Ionizing Spectrum and Static/ELF Field Exposures 15.2 Radiofrequency and Microwave Exposure: SAR, Standards, and Surveys 15.3 Ultraviolet, Visible, and Infrared Radiation Hazards 15.4 Laser Safety Classifications and Optical Density Calculations 15.5 Illumination, Lighting Design, and Visual Performance
16 Chapter 16: Non-Engineering Controls & Personal Protective Equipment
16.1 Respiratory Protection Programs and Assigned Protection Factors 16.2 Maximum Use Concentration, Oxygen Deficiency, and Breathing Air 16.3 Particulate Filters, Sorbent Cartridges, and Change Schedules 16.4 Respirator Fit Testing Protocols 16.5 Chemical Protective Clothing and Dermal Exposure Control
17 Chapter 17: Ergonomics & Workstation Design
17.1 Soft-Tissue Biomechanics and WMSD Pathophysiology 17.2 Ergonomic Risk Factors and Their Interaction Effects 17.3 The Revised NIOSH Lifting Equation 17.4 RULA, REBA, the Strain Index, and the ACGIH HAL TLV 17.5 Anthropometry and Workstation Geometry 17.6 VDT Workstations, Hand Tool Design, and Administrative Ergonomics
18 Chapter 18: Work Environments & Industrial Processes
18.1 Welding Fume Emissions, Metal Fume Fever, and Cr(VI)/Manganese Toxicology 18.2 Foundry Operations and Hot Work Fire Prevention 18.3 Vapor Degreasing, Pickling, Electroplating, and Cyanide Baths 18.4 Spray Coatings, Isocyanates, and Semiconductor Manufacturing 18.5 Confined Spaces and High-Hazard Industrial Operations 18.6 Asbestos, Lead, and Silica: Regulated Substance Programs 18.7 Abrasive Blasting and Surface Preparation
19 Chapter 19: IH Program Management & Professional Ethics
19.1 The BGC Code of Ethics: Canons and Enforcement 19.2 Professional Liability, Standard of Care, and Expert Testimony 19.3 Occupational Health & Safety Management Systems (ISO 45001, ANSI Z10) 19.4 Exposure Records Access and Medical Surveillance 19.5 OSHA Injury and Illness Recordkeeping and Enforcement
14.6 Personnel Dosimetry, Dose Limits, and Contamination Surveys
Key Takeaways Explain This Topic AI
Film badges, thermoluminescent dosimeters, and optically stimulated luminescence dosimeters give a legal dose of record; direct-reading pocket dosimeters and electronic personal dosimeters give real-time readings for stay-time control.
Under 10 CFR 20 the occupational limit is 5 rem (0.05 Sv) total effective dose equivalent per year, with 15 rem to the lens of the eye, 50 rem to skin or any extremity, and 50 rem to any individual organ.
A declared pregnant worker is limited to 0.5 rem (5 mSv) to the embryo/fetus over the entire gestation, and members of the public to 0.1 rem (1 mSv) per year.
Removable contamination is quantified by wipe survey: activity in dpm equals (gross cpm − background cpm) divided by the product of detector efficiency and wipe collection efficiency, with 10% pickup assumed when unmeasured.
Last updated: August 2026
Personnel Dosimetry, Dose Limits, and Contamination Surveys
Survey instruments characterise the field. Personnel dosimeters produce the legal record of individual dose, and that record is compared against a regulatory limit matrix that differs by organ, by age, and by pregnancy status.
1. Occupational Personnel Dosimetry Technologies
Personal dosimeters measure the cumulative dose received by an individual worker over monitoring intervals (typically monthly or quarterly). Dosimeters are worn on the torso between the waist and neck to measure Whole Body Total Effective Dose Equivalent (TEDE). +-------------------------------------------------------------------------------------------------+
- | PERSONNEL DOSIMETRY MODALITIES |
- | |
- | DOSIMETER TYPE SENSITIVE MATERIAL READOUT STIMULATION RE-READABLE? THRESHOLD |
- | ─────────────────────────────────────────────────────────────────────────────────────────── |
- | • OSL Al₂O₃:C (Aluminum Green Laser Light YES 1 mrem |
- | Oxide Carbon-doped) (532 nm) (Non-destruct) (10 µSv) |
- | |
- | • TLD LiF:Mg,Ti (Lithium Linear Thermal Heating NO 10 mrem |
- | Fluoride crystals) (Up to 300°C glow curve) (Traps cleared)(100 µSv) |
- | |
- | • Film Badge Photographic Silver Chemical Developing YES 10-20 mrem |
- | Halide Emulsion (Optical Densitometer) (Permanent) (100-200µSv)|
- | |
- | • EPD (Electronic) Silicon Diode / GM Direct Real-Time Solid YES 0.1 mrem |
- | Miniature Sensor State Digital Readout (Real-time) (1 µSv) |
- +-------------------------------------------------------------------------------------------------+
- Detailed Personnel Dosimeter Analysis
Optically Stimulated Luminescence (OSL) Dosimeters:
Material: Carbon-doped aluminum oxide (Al2O3:C) crystalline matrix.
Operating Principle: Ionizing radiation excites electrons into crystal lattice traps. In the reader, stimulation by green laser light (532 nm) releases trapped electrons, which emit blue luminescence (420 nm) proportional to dose.
Key Advantages: Ultra-high sensitivity down to 1 mrem (10 µSv) ; re-readable multiple times (laser stimulation depletes only a minute fraction of trapped electrons); unaffected by environmental moisture or temperature extremes.
Thermoluminescent Dosimeters (TLD):
Material: Magnesium- and Titanium-doped Lithium Fluoride (LiF:Mg,Ti) or Manganese-doped Calcium Fluoride (CaF2:Mn).
Operating Principle: Radiation traps electrons in metastable energy states. In the reader, the crystal is heated linearly up to 300°C , releasing trapped electrons with emission of light recorded on a Glow Curve .
Key Advantages: Tissue-equivalent effective atomic number (Zeff = 8.2 for LiF vs. 7.4 for human soft tissue); compact size ideal for extremity ring badges .
Limitation: Readout permanently empties the traps ( destructive readout—cannot be re-read ).
Film Badges:
Material: Fine-grain photographic emulsion containing Silver Bromide (AgBr) crystals mounted inside a badge with an array of metallic filters (lead, copper, cadmium, plastic, open window).
Operating Principle: Radiation ionizes Ag⁺ into metallic silver atoms, producing optical density (darkening) measured with a densitometer.
Limitation: Susceptible to heat/humidity fogging and latent image fading; being largely phased out in favor of OSL.
Direct-Reading Electronic Personal Dosimeters (EPD):
Sensor: Silicon surface-barrier diode or miniature energy-compensated GM tube.
Operating Principle: Provides instant, digital real-time readout of both accumulated dose and instantaneous dose rate. Features programmable audible, visual, and vibrating alarms for ALARA compliance in high-risk zones.
2. NRC and OSHA Regulatory Occupational Dose Limits
Occupational exposure limits are codified in 10 CFR Part 20 Subpart C (NRC) and 29 CFR 1910.1096 (OSHA). All licensees and employers must enforce these annual exposure ceilings. +-------------------------------------------------------------------------------------------------+
- | NRC & OSHA STATUTORY OCCUPATIONAL DOSE LIMITS |
- | |
- | EXPOSURE CATEGORY ANNUAL DOSE LIMIT (TRADITIONAL) ANNUAL DOSE LIMIT (SI) |
- | ─────────────────────────────────────────────────────────────────────────────────────────── |
- | • Whole Body (TEDE = DDE + CEDE) 5.0 rem / year 50 mSv / year (0.05 Sv) |
- | • Lens of the Eye (LDE) 15.0 rem / year 150 mSv / year (0.15 Sv)|
- | • Skin / Extremities (SDE_ME) 50.0 rem / year 500 mSv / year (0.50 Sv)|
- | • Individual Organ (TODE=DDE+CDE) 50.0 rem / year 500 mSv / year (0.50 Sv)|
- | • Declared Pregnant Worker (Fetus) 0.50 rem / gestation period 5.0 mSv / gestation |
- | (and ≤ 0.05 rem / month) (and ≤ 0.5 mSv / month) |
- | • Minors (< 18 years of age) 0.50 rem / year (10% adult limit) 5.0 mSv / year |
- | • General Public Dose Limit 0.10 rem / year 1.0 mSv / year (100 mrem|
- | • Unrestricted Area Boundary Rate ≤ 0.002 rem in any 1 hour ≤ 0.02 mSv / hour |
- +-------------------------------------------------------------------------------------------------+
- Comprehensive Dosimetric Definitions and Acronyms
Deep Dose Equivalent (DDE): External whole-body exposure evaluated at a tissue depth of 1.0 cm (1,000 mg/cm²).
Eye Dose Equivalent (LDE): External exposure to the lens of the eye evaluated at a tissue depth of 0.3 cm (300 mg/cm²).
Shallow Dose Equivalent (SDE): External exposure to the skin or extremity evaluated at a tissue depth of 0.007 cm (7 mg/cm²) averaged over an area of 10 cm².
Committed Dose Equivalent (CDE, H(T,50)): Dose equivalent to a specific organ/tissue that will be accumulated over a 50-year commitment period following the intake of radioactive material.
Committed Effective Dose Equivalent (CEDE, E50): Sum of the weighted committed dose equivalents to all irradiated organs from internal intake: CEDE = Σ wT × CDET.
Total Effective Dose Equivalent (TEDE): The fundamental whole-body regulatory compliance parameter: TEDE = DDE + CEDE \mathbf{\text{TEDE} = \text{DDE} + \text{CEDE}} TEDE = DDE + CEDE
Total Organ Dose Equivalent (TODE): Regulatory compliance metric for individual non-stochastic deterministic organ protection: TODE = DDE + CDE organ ≤ 50 rem/year \mathbf{\text{TODE} = \text{DDE} + \text{CDE}_{\text{organ}} \le 50\text{ rem/year}} TODE = DDE + CDE organ ≤ 50 rem/year
Declared Pregnant Worker Regulations (10 CFR 20.1208)
The declaration of pregnancy is strictly voluntary , must be in written form , and can be revoked by the worker at any time without penalty.
Once declared, the licensee must ensure that the dose to the embryo/fetus does not exceed 0.5 rem (5.0 mSv or 500 mrem) over the entire gestation period.
Licensees must avoid substantial monthly dose variations, maintaining exposure at or below approximately 0.05 rem/month (50 mrem/month) .
If the fetal dose has already exceeded 0.5 rem by the time the worker submits the written declaration, the licensee is compliant provided an additional dose of no more than 0.05 rem (50 mrem) is received during the remainder of the pregnancy.
3. Contamination Surveys, Wipe Testing, and Sealed Source Leak Criteria
Radioactive contamination is categorized as fixed (bound to surfaces) or removable (transferred by contact or air currents). +-------------------------------------------------------------------------------------------------+
- | SEALED RADIOACTIVE SOURCE LEAK TEST STANDARDS |
- | |
- | • REGULATORY REMOVAL THRESHOLD: 0.005 µCi = 185 Bq = 11,100 dpm |
- | |
- | • Testing Frequency: Every 6 months (gamma/beta); Every 3 months (alpha) |
- | • Standard Wipe Surface Area: 100 cm² swipe using moderate pressure |
- | • Mandatory Reporting: If wipe ≥ 0.005 µCi, IMMEDIATELY remove source from service, |
- | isolate in sealed container, and file formal NRC / Agreement|
- | State report within 5 days. |
- +-------------------------------------------------------------------------------------------------+
- Removable Contamination Smear Calculation
When evaluating a 100 cm² surface wipe counted on a laboratory detector: Activity (dpm) = Gross Count Rate (cpm) − Background Count Rate (cpm) Detector Efficiency ( ϵ det ) × Wipe Collection Efficiency ( ϵ wipe ) \mathbf{\text{Activity (dpm)} = \frac{\text{Gross Count Rate (cpm)} - \text{Background Count Rate (cpm)}}{\text{Detector Efficiency } (\epsilon_{\text{det}}) \times \text{Wipe Collection Efficiency } (\epsilon_{\text{wipe}})}} Activity (dpm) = Detector Efficiency ( ϵ det ) × Wipe Collection Efficiency ( ϵ wipe ) Gross Count Rate (cpm) − Background Count Rate (cpm) Activity ( μ Ci) = Activity (dpm) 2.22 × 10 6 dpm/ μ Ci \mathbf{\text{Activity (}\mu\text{Ci)} = \frac{\text{Activity (dpm)}}{2.22 \times 10^6\text{ dpm/}\mu\text{Ci}}} Activity ( μ Ci) = 2.22 × 1 0 6 dpm/ μ Ci Activity (dpm)
Note: Where wipe collection efficiency is unknown, a conservative standard default factor of εwipe = 0.10 (10% pickup efficiency) is standard practice.
- 4. Worked Step-by-Step Calculation Examples
- Worked Example 13.5: TEDE Evaluation and Annual Regulatory Compliance Assessment
Scenario: A radiochemist's annual dosimetry records reveal the following exposure parameters over a calendar year:
Deep Dose Equivalent (DDE) from external gamma radiation = 1.85 rem (18.5 mSv).
Shallow Dose Equivalent to the hands (ring badge, SDEME) = 14.20 rem (142.0 mSv).
Eye Dose Equivalent (LDE) = 2.40 rem (24.0 mSv).
Internal intake of Radioiodine-131 resulting in a Committed Dose Equivalent (CDE) to the Thyroid of 45.0 rem (450.0 mSv). (ICRP 103 tissue weighting factor for thyroid w(T,thyroid) = 0.04).
Calculate the radiochemist's Committed Effective Dose Equivalent (CEDE).
Calculate the Total Effective Dose Equivalent (TEDE) and evaluate compliance against the NRC 10 CFR 20 annual limit.
Calculate the Total Organ Dose Equivalent (TODE) to the thyroid and evaluate compliance against the non-stochastic organ limit.
Assess compliance for the extremities (extSDE) and lens of the eye (extLDE).
Solution Steps:
Calculate Committed Effective Dose Equivalent (CEDE): CEDE = CDE thyroid × w T , thyroid = 45.0 rem × 0.04 = 1.80 rem ( 18.0 mSv ) \text{CEDE} = \text{CDE}_{\text{thyroid}} \times w_{T,\text{thyroid}} = 45.0\text{ rem} \times 0.04 = 1.80\text{ rem} \quad (18.0\text{ mSv}) CEDE = CDE thyroid × w T , thyroid = 45.0 rem × 0.04 = 1.80 rem ( 18.0 mSv )
Calculate Total Effective Dose Equivalent (TEDE): TEDE = DDE + CEDE = 1.85 rem + 1.80 rem = 3.65 rem ( 36.5 mSv ) \text{TEDE} = \text{DDE} + \text{CEDE} = 1.85\text{ rem} + 1.80\text{ rem} = 3.65\text{ rem} \quad (36.5\text{ mSv}) TEDE = DDE + CEDE = 1.85 rem + 1.80 rem = 3.65 rem ( 36.5 mSv )
Regulatory Limit: 5.00 rem/year.
Compliance: Since TEDE = 3.65 rem ≤ 5.00 rem, whole-body exposure is in compliance .
Calculate Total Organ Dose Equivalent (TODE) to Thyroid: TODE thyroid = DDE + CDE thyroid = 1.85 rem + 45.0 rem = 46.85 rem ( 468.5 mSv ) \text{TODE}_{\text{thyroid}} = \text{DDE} + \text{CDE}_{\text{thyroid}} = 1.85\text{ rem} + 45.0\text{ rem} = 46.85\text{ rem} \quad (468.5\text{ mSv}) TODE thyroid = DDE + CDE thyroid = 1.85 rem + 45.0 rem = 46.85 rem ( 468.5 mSv )
Regulatory Limit: 50.00 rem/year to any individual organ.
Compliance: Since TODE = 46.85 rem ≤ 50.00 rem, organ exposure is in compliance .
Evaluate Extremities and Eye Dose Compliance:
Extremities (SDEME) = 14.20 rem ≤ 50.00 rem/year limit ( Compliant ).
Lens of Eye (LDE) = 2.40 rem ≤ 15.00 rem/year limit ( Compliant ).
Conclusion: All occupational exposures comply with NRC 10 CFR 20 statutory limits.
Worked Example 13.6: Sealed Source Leak Wipe Test Assessment
Scenario: An industrial hygienist performs a 6-month regulatory leak test on a 5.0 Ci (185 GBq) Cesium-137 sealed level gauge. A standard 100 cm² smear wipe of the housing is counted on a gas-flow proportional counter:
- Gross Count Rate = 3,450 cpm
- Instrument Background Count Rate = 45 cpm
- Sample Count Time = 10.0 minutes
- Detector 4-pi counting efficiency (εdet) = 38.0% (0.380)
- Smear wipe collection efficiency (εwipe) = assumed standard default of 10.0% (0.10)
Calculate the net removable activity on the wipe in disintegrations per minute (dpm).
Calculate the removable activity in microcuries (µCi) and Becquerels (Bq).
Determine whether the sealed source exceeds the statutory leak threshold under NRC regulations.
Solution Steps:
Calculate Net Count Rate (cpm): Net CPM = Gross CPM − Background CPM = 3 , 450 cpm − 45 cpm = 3 , 405 cpm \text{Net CPM} = \text{Gross CPM} - \text{Background CPM} = 3,450\text{ cpm} - 45\text{ cpm} = 3,405\text{ cpm} Net CPM = Gross CPM − Background CPM = 3 , 450 cpm − 45 cpm = 3 , 405 cpm
Calculate Total Removable Disintegration Rate (dpm): Activity (dpm) = Net CPM ϵ det × ϵ wipe = 3 , 405 cpm 0.380 × 0.10 = 3 , 405 0.0380 = 89 , 605 dpm \text{Activity (dpm)} = \frac{\text{Net CPM}}{\epsilon_{\text{det}} \times \epsilon_{\text{wipe}}} = \frac{3,405\text{ cpm}}{0.380 \times 0.10} = \frac{3,405}{0.0380} = 89,605\text{ dpm} Activity (dpm) = ϵ det × ϵ wipe Net CPM = 0.380 × 0.10 3 , 405 cpm = 0.0380 3 , 405 = 89 , 605 dpm
Convert to Microcuries (µCi) and Becquerels (Bq): Activity ( μ Ci) = 89 , 605 dpm 2.22 × 10 6 dpm/ μ Ci = 0.04036 μ Ci \text{Activity (}\mu\text{Ci)} = \frac{89,605\text{ dpm}}{2.22 \times 10^6\text{ dpm/}\mu\text{Ci}} = 0.04036\ \mu\text{Ci} Activity ( μ Ci) = 2.22 × 1 0 6 dpm/ μ Ci 89 , 605 dpm = 0.04036 μ Ci Activity (Bq) = 0.04036 μ Ci × 3.700 × 10 4 Bq/ μ Ci = 1 , 493.4 Bq \text{Activity (Bq)} = 0.04036\ \mu\text{Ci} \times 3.700 \times 10^4\text{ Bq/}\mu\text{Ci} = 1,493.4\text{ Bq} Activity (Bq) = 0.04036 μ Ci × 3.700 × 1 0 4 Bq/ μ Ci = 1 , 493.4 Bq
Evaluate Against NRC Statutory Threshold:
NRC statutory leak threshold = 0.005 µCi (185 Bq or 11,100 dpm) .
Measured removable activity = 0.0404 µCi (1,493 Bq) , which is over 8 times the legal limit .
Mandatory Action: The sealed source is leaking . Immediately remove the source from service, isolate the unit within a secure container, post contamination warning signs, and submit a formal report to the NRC or Agreement State regulator within 5 days .