Study guide

12.4 Exchange Rates, Extended Shifts, and Dosimetry Field Protocols

CIH Certified Industrial Hygienist Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: The CIH Exam and How to Use This Guide

1.1 CIH Exam Format, Scoring, and Test-Day Logistics 1.2 Eligibility, Application Windows, Fees, and Certification Maintenance 1.3 The BGC Blueprint, Subject Areas, and a Calculation-First Study Plan

2 Chapter 2: Basic Science & Calculations

2.1 Gas Laws and Vapor Calculations 2.2 Unit Conversions: ppm, mg/m³, and Standard Temperature/Pressure 2.3 Fluid Mechanics and Airflow Fundamentals

3 Chapter 3: Air Sampling & Instrumentation

3.1 Active and Passive Air Sampling Strategies 3.2 Particulate and Aerosol Sampling 3.3 Direct-Reading Instruments and Calibration

4 Chapter 4: Analytical Chemistry & Lab Methods

4.1 Gas Chromatography and Mass Spectrometry 4.2 High-Performance Liquid Chromatography and Ion Chromatography 4.3 Spectroscopy and Elemental Analysis 4.4 Gravimetric, Microscopy, and Wet Chemical Methods 4.5 Laboratory Quality Assurance, Chain of Custody, and Desorption Efficiency

5 Chapter 5: Biostatistics & Epidemiology

5.1 Lognormal Distributions and Exposure Data Statistics 5.2 Upper Confidence Limits (UCL95) and Compliance Decision Rules 5.3 Epidemiological Study Designs and Measures of Association 5.4 Sampling Strategy: Sample Size, Power, and Worker Selection

6 Chapter 6: Toxicology & Biological Monitoring

6.1 Dose-Response Relationships and Points of Departure 6.2 Toxicokinetics: Absorption, Distribution, Metabolism, and Elimination 6.3 Aerosol Deposition, Clearance, and Respiratory Tract Dosimetry 6.4 Hepatic, Renal, Neurologic, and Hematologic Target Organ Toxicity 6.5 Pulmonary Toxicology, Carcinogenicity, and Reproductive Hazards 6.6 OEL Frameworks, Classifications, and Excursion Limits 6.7 Chemical Mixtures and Extended Work-Shift OEL Adjustments 6.8 Biological Exposure Indices (BEIs) and Biomonitoring

7 Chapter 7: Biohazards & Indoor Environmental Quality

7.1 Mold, Fungi, and Microbial Contaminants 7.2 Infectious Agents, Bloodborne Pathogens, and Biosafety Levels 7.3 Indoor Environmental Quality (IEQ) Investigations 7.4 Sanitation, Potable Water, and Personal Hygiene Programs

8 Chapter 8: Community Exposure & Environmental Health

8.1 Clean Air Act Framework, NAAQS, and New Source Review 8.2 Hazardous Air Pollutants, CEMS, and EPA Reference Methods 8.3 Atmospheric Stability, Lapse Rates, and Plume Morphology 8.4 Gaussian Plume Modeling, Plume Rise, and Environmental Fate 8.5 HAZWOPER Scope, Mandates, and Training Tiers 8.6 Protection Levels, Site Zoning, Incident Command, and Decontamination 8.7 Water Pollution, Hazardous Waste, and Community Right-to-Know

9 Chapter 9: Health Risk Analysis & Hazard Communication

9.1 GHS Hazard Classification: Health and Physical Hazard Criteria 9.2 GHS Labels, Safety Data Sheets, and Trade Secret Rules 9.3 The AIHA Exposure Assessment Strategy and Similar Exposure Groups 9.4 Qualitative Exposure Profiling and the AIHA Risk Matrix 9.5 Quantitative Health Risk Characterization: HQ, HI, and ELCR 9.6 NIOSH Occupational Exposure Banding 9.7 Risk Communication and Reporting to Affected Parties

10 Chapter 10: Industrial Ventilation Principles & LEV Design

10.1 Elimination, Substitution, Isolation, Containment, and Process Change 10.2 LEV Hood Taxonomy and Capture Velocity Selection 10.3 Hood Airflow Equations, Entry Losses, and Hood Static Pressure 10.4 Particulate Transport Aerodynamics and Duct Sizing 10.5 Duct Friction, Fitting Losses, and System Balancing 10.6 Fan Categories and Pressure Dynamics Across the Fan 10.7 System Curves, the Fan Laws, and Density Corrections

11 Chapter 11: General Ventilation, Air Cleaning & Diagnostics

11.1 Dilution Ventilation Principles and Steady-State Modeling 11.2 Transient Purging and Air Distribution Geometry 11.3 Particulate Air Cleaning: Cyclones, Baghouses, Scrubbers, and ESPs 11.4 Gaseous Emission Control and Air Cleaner Selection 11.5 Ventilation System Troubleshooting and Testing

12 Chapter 12: Noise Measurement & Hearing Conservation

12.1 Acoustic Physics and Decibel Mathematics 12.2 Sound Propagation, Octave Bands, and Frequency Weighting 12.3 Noise Dose Metrics and OSHA versus ACGIH Criteria 12.4 Exchange Rates, Extended Shifts, and Dosimetry Field Protocols 12.5 Engineering Noise Controls and Hearing Protector Attenuation 12.6 Hearing Conservation Programs and Standard Threshold Shifts 12.7 Hand-Arm and Whole-Body Vibration

13 Chapter 13: Thermal Stress Assessment & Control

13.1 Wet Bulb Globe Temperature (WBGT) and Heat Stress Indices 13.2 Heat-Related Disorders, Acclimatization, and Work/Rest Regimens 13.3 Cold Stress Evaluation and Wind Chill

14 Chapter 14: Ionizing Radiation Protection

14.1 Ionizing Radiation Physics and Radioactive Decay Kinetics 14.2 Radiation Units, Radiobiology, and Health Effects 14.3 ALARA, Stay-Time, and the Inverse Square Law 14.4 Shielding Physics, Material Selection, and Gamma Constants 14.5 Radiation Detection Instruments and Spectrometry 14.6 Personnel Dosimetry, Dose Limits, and Contamination Surveys

15 Chapter 15: Non-Ionizing Radiation & Laser Safety

15.1 The Non-Ionizing Spectrum and Static/ELF Field Exposures 15.2 Radiofrequency and Microwave Exposure: SAR, Standards, and Surveys 15.3 Ultraviolet, Visible, and Infrared Radiation Hazards 15.4 Laser Safety Classifications and Optical Density Calculations 15.5 Illumination, Lighting Design, and Visual Performance

16 Chapter 16: Non-Engineering Controls & Personal Protective Equipment

16.1 Respiratory Protection Programs and Assigned Protection Factors 16.2 Maximum Use Concentration, Oxygen Deficiency, and Breathing Air 16.3 Particulate Filters, Sorbent Cartridges, and Change Schedules 16.4 Respirator Fit Testing Protocols 16.5 Chemical Protective Clothing and Dermal Exposure Control

17 Chapter 17: Ergonomics & Workstation Design

17.1 Soft-Tissue Biomechanics and WMSD Pathophysiology 17.2 Ergonomic Risk Factors and Their Interaction Effects 17.3 The Revised NIOSH Lifting Equation 17.4 RULA, REBA, the Strain Index, and the ACGIH HAL TLV 17.5 Anthropometry and Workstation Geometry 17.6 VDT Workstations, Hand Tool Design, and Administrative Ergonomics

18 Chapter 18: Work Environments & Industrial Processes

18.1 Welding Fume Emissions, Metal Fume Fever, and Cr(VI)/Manganese Toxicology 18.2 Foundry Operations and Hot Work Fire Prevention 18.3 Vapor Degreasing, Pickling, Electroplating, and Cyanide Baths 18.4 Spray Coatings, Isocyanates, and Semiconductor Manufacturing 18.5 Confined Spaces and High-Hazard Industrial Operations 18.6 Asbestos, Lead, and Silica: Regulated Substance Programs 18.7 Abrasive Blasting and Surface Preparation

19 Chapter 19: IH Program Management & Professional Ethics

19.1 The BGC Code of Ethics: Canons and Enforcement 19.2 Professional Liability, Standard of Care, and Expert Testimony 19.3 Occupational Health & Safety Management Systems (ISO 45001, ANSI Z10) 19.4 Exposure Records Access and Medical Surveillance 19.5 OSHA Injury and Illness Recordkeeping and Enforcement

12.4 Exchange Rates, Extended Shifts, and Dosimetry Field Protocols

Key Takeaways Explain This Topic AI

The 3 dB exchange rate is the equal-energy rule: halving the exposure time permits a 3 dB increase because acoustic energy doubles every 3 dB.

The 5 dB OSHA rate assumes intermittency allows partial cochlear recovery; it is less protective than 3 dB for variable exposures and is not supported by current evidence.

OSHA adjusts the PEL for extended shifts as L = 90 − 16.61·log10(h/8), giving about 87.1 dBA for a 12-hour shift; the ACGIH adjustment uses 10·log10(8/h) with the 3 dB rate.

Field protocol requires calibrating the dosimeter before and after the shift, placing the microphone in the hearing zone within about 30 cm of the ear on the noisier shoulder, and documenting the configuration because the dose is meaningless without it.

Last updated: August 2026

Exchange Rates, Extended Shifts, and Dosimetry Field Protocols

The two standards disagree about a single parameter — the exchange rate — and that disagreement propagates into every allowable duration, every extended-shift adjustment, and every dosimeter setup decision.

1. Exchange Rate Physics: 3 dB (Equal Energy) vs. 5 dB (OSHA Rule)

The choice of Exchange Rate (q) —the increment of decibel increase that requires cutting allowable exposure duration in half—represents one of the most critical conceptual divides in occupational health:

The 3 dB Exchange Rate (Equal Energy Rule - ACGIH / NIOSH / ISO):

Based on the acoustic physical law where sound energy doubles every 3.01 dB (10log10(2) = 3.01).

Assumes that equal amounts of total acoustic energy cause equal amounts of sensorineural cochlear hair cell damage, regardless of temporal distribution.

Halves allowable exposure time for every 3 dBA increase.

The 5 dB Exchange Rate (OSHA Trading Rule - 29 CFR 1910.95):

Adopted by OSHA in 1971 from the Walsh-Healey Public Contracts Act.

Incorporated an empirical "intermittent rest recovery factor," hypothesizing that workplace noise intermittency allows biological recovery of the auditory hair cells during quiet lulls.

Halves allowable exposure time for every 5 dBA increase.

Modern Audiological Consensus: The 5 dB exchange rate significantly underestimates hearing loss risk for intermittent industrial noise, which is why ACGIH, NIOSH, the U.S. Department of Defense (DoD), and international standards enforce the 3 dB rule.

2. Allowable Daily Exposure Duration Comparison Table

The table below demonstrates how the 3 dB and 5 dB exchange rates diverge across occupational sound levels:

Sound Level (Lp) OSHA Permissible Duration (5 dB Rule) ACGIH / NIOSH Permissible Duration (3 dB Rule) Ratio of OSHA to ACGIH Allowable Time

  • 80 dBA 32.0 hours 25.4 hours (25 hr 24 min) 1.26×
  • 82 dBA 24.3 hours 16.0 hours 1.52×
  • 85 dBA 16.0 hours 8.0 hours 2.00×
  • 88 dBA 10.6 hours (10 hr 34 min) 4.0 hours 2.64×
  • 90 dBA 8.0 hours 2.52 hours (2 hr 31 min) 3.17×
  • 91 dBA 6.96 hours (6 hr 58 min) 2.0 hours 3.48×
  • 94 dBA 4.60 hours (4 hr 36 min) 1.0 hour (60 min) 4.60×
  • 95 dBA 4.0 hours 0.794 hours (47.6 min) 5.04×
  • 97 dBA 3.03 hours (3 hr 2 min) 0.50 hours (30 min) 6.06×
  • 100 dBA 2.0 hours 0.25 hours (15 min) 8.00×
  • 103 dBA 1.32 hours (1 hr 19 min) 0.125 hours (7.5 min) 10.56×
  • 105 dBA 1.0 hour (60 min) 0.0625 hours (3.75 min) 16.00×
  • 110 dBA 0.50 hours (30 min) 0.0156 hours (56.2 sec) 32.00×
  • 115 dBA 0.25 hours (15 min) (OSHA max!) 0.0039 hours (14.1 sec) 64.00×

Critical Takeaway: At 100 dBA, OSHA allows 2.0 hours of unprotected exposure, whereas ACGIH permits only 15 minutes —an 8-fold difference in allowable exposure duration!

3. Extended and Non-Standard Work Shifts

With 10-hour and 12-hour compressed work shifts becoming standard across industrial operations, industrial hygienists must adjust permissible exposure criteria to prevent occupational overexposure.

Mathematical Shift Adjustments

OSHA Extended Shift Interpretation:

Under OSHA 29 CFR 1910.95, compliance for extended shifts (h > 8 hr) is determined by calculating the 8-hour TWA using the total cumulative dose (D) across the entire extended shift: TWA = 16.61 log10(D / 100) + 90. If the resulting TWA exceeds 85 dBA, the employee must be enrolled in the Hearing Conservation Program.

Adjusted Action Level for Extended Shifts (Ladj): L adj = 90 − 16.61 log ⁡ 10 ( h 8 ) L_{\text{adj}} = 90 - 16.61 \log_{10}\left(\frac{h}{8}\right) L adj ​ = 90 − 16.61 lo g 10 ​ ( 8 h ​ )

For a 10-hour shift : Ladj = 90 - 16.61 log10(10/8) = 90 - 16.61(0.0969) = 88.4 dBA PEL (Action Level = 83.4 dBA).

For a 12-hour shift : Ladj = 90 - 16.61 log10(12/8) = 90 - 16.61(0.1761) = 87.1 dBA PEL (Action Level = 82.1 dBA ).

ACGIH / NIOSH Extended Shift (3 dB Rule): L adj = 85 − 10 log ⁡ 10 ( h 8 ) L_{\text{adj}} = 85 - 10 \log_{10}\left(\frac{h}{8}\right) L adj ​ = 85 − 10 lo g 10 ​ ( 8 h ​ )

For a 12-hour shift : Ladj = 85 - 10 log10(12/8) = 85 - 1.76 = 83.2 dBA.

4. Personal Noise Dosimetry Field Sampling Protocols

To ensure legally defensible and audiological valid exposure data, industrial hygienists must enforce strict field sampling protocols: +-------------------------------------------------------------------------+

  • | DOSIMETER FIELD DEPLOYMENT PROTOCOL |
  • +-------------------------------------------------------------------------+
  • | |
  • | Microphone Placement: |
  • | - Top of shoulder, mid-collarbone (halfway between neck & shoulder)|
  • | - Pointed upward toward ear canal |
  • | - Fitted with acoustic open-cell foam windscreen |
  • | |
  • | [ HEAD / EAR ] |
  • | | |
  • | +--- Microphone here! |
  • | / (Top of shoulder) |
  • | [ SHOULDER ] |
  • | | |
  • | [ TORSO ] ===> Dosimeter unit clipped to belt |
  • +-------------------------------------------------------------------------+
  • Mandatory Sampling Procedures

Microphone Placement: Position the dosimeter microphone on the top of the employee's shoulder , halfway between the neck and the outer edge of the shoulder, oriented facing vertically upward. (For tasks with a localized directional noise source, position on the shoulder facing the source).

Acoustic Windscreen Requirement: An open-cell reticulated polyurethane foam windscreen must be fitted over the microphone at all times to prevent false acoustic energy spikes generated by room air currents, HVAC supply diffusers, or convective drafts.

Pre- and Post-Calibration Verification:

Perform field calibration before and after every monitoring session using an approved acoustic calibrator operating at a known level (e.g., 114.0 dB or 94.0 dB at 1,000 Hz).

Calibration Drift Limit: If the post-calibration reading differs by more than 0.5 dB from the pre-calibration reading, the entire sampling survey is invalidated and must be repeated.

Time-Activity Logging: The hygienist must maintain an active field time-and-motion log documenting worker locations, tasks, machinery cycled, and non-occupational acoustic events (e.g., dropped objects, microphone bumps, shouting) to interpret dosimeter time-history trend graphs.

  • 5. Worked Step-by-Step Calculation Examples
  • Worked Example 11.2.1: OSHA Noise Dose and 8-Hour TWA Calculation

Problem: A maintenance mechanic's 8-hour shift involves three distinct tasks with the following sound level exposures:

  • Task 1 (Boiler room maintenance): 90.0 dBA for C1 = 3.0 hours
  • Task 2 (Operating angle grinder): 95.0 dBA for C2 = 1.5 hours
  • Task 3 (Shop bench assembly): 85.0 dBA for C3 = 3.5 hours

Calculate the employee's OSHA Noise Dose (D) for Hearing Conservation compliance (80 dBA threshold, 5 dB exchange rate).

Calculate the corresponding OSHA 8-hour Time-Weighted Average (TWA).

Determine whether the employee exceeds the OSHA Action Level (85 dBA) and/or OSHA PEL (90 dBA).

Solution Steps:

Determine allowable reference times (Ti = 8 / 2([(Li - 90)/5])) under OSHA:

  • At L1 = 90.0 dBA: T1 = 8 / 2⁰ = 8.0 hours
  • At L2 = 95.0 dBA: T2 = 8 / 2([(95-90)/5]) = 8 / 2¹ = 4.0 hours
  • At L3 = 85.0 dBA: T3 = 8 / 2([(85-90)/5]) = 8 / 2⁻¹ = 16.0 hours

Calculate cumulative OSHA Noise Dose (D = 100 × Σ [Ci / Ti]): D = 100 × ( 3.0 8.0 + 1.5 4.0 + 3.5 16.0 ) D = 100 \times \left( \frac{3.0}{8.0} + \frac{1.5}{4.0} + \frac{3.5}{16.0} \right) D = 100 × ( 8.0 3.0 ​ + 4.0 1.5 ​ + 16.0 3.5 ​ ) D = 100 × ( 0.3750 + 0.3750 + 0.21875 ) = 100 × 0.96875 = 96.88 % D = 100 \times (0.3750 + 0.3750 + 0.21875) = 100 \times 0.96875 = \mathbf{96.88\%} D = 100 × ( 0.3750 + 0.3750 + 0.21875 ) = 100 × 0.96875 = 96.88%

Calculate OSHA 8-hour TWA (TWA = 16.61 log10[D / 100] + 90): D 100 = 0.96875 \frac{D}{100} = 0.96875 100 D ​ = 0.96875 log ⁡ 10 ( 0.96875 ) = − 0.013788 \log_{10}(0.96875) = -0.013788 lo g 10 ​ ( 0.96875 ) = − 0.013788 TWA = 16.61 × ( − 0.013788 ) + 90 = − 0.229 + 90 = 89.771 dBA ≈ 89.8 dBA \text{TWA} = 16.61 \times (-0.013788) + 90 = -0.229 + 90 = 89.771\text{ dBA} \approx \mathbf{89.8\text{ dBA}} TWA = 16.61 × ( − 0.013788 ) + 90 = − 0.229 + 90 = 89.771 dBA ≈ 89.8 dBA

Evaluate Regulatory Compliance:

Action Level (85.0 dBA / 50% Dose): Exceeded (96.88% > 50%; 89.8 dBA > 85.0 dBA). The employer must enroll the worker in a Hearing Conservation Program.

PEL (90.0 dBA / 100% Dose): Not exceeded (96.88% < 100%; 89.8 dBA < 90.0 dBA). Feasible engineering controls are not legally mandated, though recommended.

Result: The worker's OSHA dose is 96.9% and 8-hour TWA is 89.8 dBA (exceeding the Action Level but below the PEL).

Worked Example 11.2.2: ACGIH TLV Dose and TWA Calculation under 3 dB Rule

Problem: Evaluate the exact same worker's exposure profile from Example 11.2.1 under the ACGIH TLV guidelines (85 dBA criterion, 3 dB exchange rate, 80 dBA threshold):

  • Task 1: 90.0 dBA for 3.0 hr
  • Task 2: 95.0 dBA for 1.5 hr
  • Task 3: 85.0 dBA for 3.5 hr

Solution Steps:

Determine allowable reference times (Ti = 8 / 2([(Li - 85)/3])) under ACGIH:

  • At L1 = 90.0 dBA: T1 = 8 / 2([(90-85)/3]) = 8 / 2(1.6667) = 8 / 3.1748 = 2.520 hours
  • At L2 = 95.0 dBA: T2 = 8 / 2([(95-85)/3]) = 8 / 2(3.3333) = 8 / 10.0794 = 0.7937 hours (47.6 min)
  • At L3 = 85.0 dBA: T3 = 8 / 2([(85-85)/3]) = 8 / 2⁰ = 8.000 hours

Calculate cumulative ACGIH Noise Dose (DACGIH): D ACGIH = 100 × ( 3.0 2.520 + 1.5 0.7937 + 3.5 8.000 ) D_{\text{ACGIH}} = 100 \times \left( \frac{3.0}{2.520} + \frac{1.5}{0.7937} + \frac{3.5}{8.000} \right) D ACGIH ​ = 100 × ( 2.520 3.0 ​ + 0.7937 1.5 ​ + 8.000 3.5 ​ ) D ACGIH = 100 × ( 1.1905 + 1.8899 + 0.4375 ) = 100 × 3.5179 = 351.8 % D_{\text{ACGIH}} = 100 \times (1.1905 + 1.8899 + 0.4375) = 100 \times 3.5179 = \mathbf{351.8\%} D ACGIH ​ = 100 × ( 1.1905 + 1.8899 + 0.4375 ) = 100 × 3.5179 = 351.8%

Calculate ACGIH 8-hour TWA (TWA = 10 log10[D / 100] + 85): D 100 = 3.5179 \frac{D}{100} = 3.5179 100 D ​ = 3.5179 log ⁡ 10 ( 3.5179 ) = 0.54628 \log_{10}(3.5179) = 0.54628 lo g 10 ​ ( 3.5179 ) = 0.54628 TWA ACGIH = 10 × 0.54628 + 85 = 5.463 + 85 = 90.5 dBA \text{TWA}_{\text{ACGIH}} = 10 \times 0.54628 + 85 = 5.463 + 85 = \mathbf{90.5\text{ dBA}} TWA ACGIH ​ = 10 × 0.54628 + 85 = 5.463 + 85 = 90.5 dBA

Result: Under ACGIH TLV criteria, the worker receives a 351.8% Dose and an 8-hour TWA of 90.5 dBA , severely exceeding the TLV (100% / 85 dBA).

Worked Example 11.2.3: Converting Noise Dose to TWA for a Non-8-Hour Shift

Problem: A miner works a 10-hour shift. A personal noise dosimeter configured to OSHA Hearing Conservation parameters (90 dBA criterion, 5 dB exchange rate, 80 dBA threshold) runs for the full 10-hour shift (600 minutes) and displays a cumulative dose of D = 180.0%.

Calculate the equivalent 8-hour Time-Weighted Average (TWA(8-hr)).

Calculate the actual 10-hour average sound level (Lavg).

Solution Steps:

Calculate equivalent 8-hour TWA (standard OSHA compliance formula): TWA 8 -hr = 16.61 log ⁡ 10 ( 180.0 100 ) + 90 \text{TWA}_{8\text{-hr}} = 16.61 \log_{10}\left(\frac{180.0}{100}\right) + 90 TWA 8 -hr ​ = 16.61 lo g 10 ​ ( 100 180.0 ​ ) + 90 log ⁡ 10 ( 1.80 ) = 0.25527 \log_{10}(1.80) = 0.25527 lo g 10 ​ ( 1.80 ) = 0.25527 TWA 8 -hr = 16.61 × 0.25527 + 90 = 4.240 + 90 = 94.24 dBA \text{TWA}_{8\text{-hr}} = 16.61 \times 0.25527 + 90 = 4.240 + 90 = \mathbf{94.24\text{ dBA}} TWA 8 -hr ​ = 16.61 × 0.25527 + 90 = 4.240 + 90 = 94.24 dBA

Calculate 10-hour average sound level (Lavg): L avg = 16.61 log ⁡ 10 ( D 100 × 8 T actual ) + 90 L_{\text{avg}} = 16.61 \log_{10}\left( \frac{D}{100} \times \frac{8}{T_{\text{actual}}} \right) + 90 L avg ​ = 16.61 lo g 10 ​ ( 100 D ​ × T actual ​ 8 ​ ) + 90 L avg = 16.61 log ⁡ 10 ( 1.80 × 8 10 ) + 90 = 16.61 log ⁡ 10 ( 1.44 ) + 90 L_{\text{avg}} = 16.61 \log_{10}\left( 1.80 \times \frac{8}{10} \right) + 90 = 16.61 \log_{10}(1.44) + 90 L avg ​ = 16.61 lo g 10 ​ ( 1.80 × 10 8 ​ ) + 90 = 16.61 lo g 10 ​ ( 1.44 ) + 90 log ⁡ 10 ( 1.44 ) = 0.15836 \log_{10}(1.44) = 0.15836 lo g 10 ​ ( 1.44 ) = 0.15836 L avg = 16.61 × 0.15836 + 90 = 2.630 + 90 = 92.63 dBA L_{\text{avg}} = 16.61 \times 0.15836 + 90 = 2.630 + 90 = \mathbf{92.63\text{ dBA}} L avg ​ = 16.61 × 0.15836 + 90 = 2.630 + 90 = 92.63 dBA

Result: The 8-hour TWA is 94.2 dBA (used for regulatory compliance), and the actual average exposure over the 10-hour period is 92.6 dBA .