Study guide
12.6 Hearing Conservation Programs and Standard Threshold Shifts
CIH Certified Industrial Hygienist Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: The CIH Exam and How to Use This Guide
1.1 CIH Exam Format, Scoring, and Test-Day Logistics 1.2 Eligibility, Application Windows, Fees, and Certification Maintenance 1.3 The BGC Blueprint, Subject Areas, and a Calculation-First Study Plan
2 Chapter 2: Basic Science & Calculations
2.1 Gas Laws and Vapor Calculations 2.2 Unit Conversions: ppm, mg/m³, and Standard Temperature/Pressure 2.3 Fluid Mechanics and Airflow Fundamentals
3 Chapter 3: Air Sampling & Instrumentation
3.1 Active and Passive Air Sampling Strategies 3.2 Particulate and Aerosol Sampling 3.3 Direct-Reading Instruments and Calibration
4 Chapter 4: Analytical Chemistry & Lab Methods
4.1 Gas Chromatography and Mass Spectrometry 4.2 High-Performance Liquid Chromatography and Ion Chromatography 4.3 Spectroscopy and Elemental Analysis 4.4 Gravimetric, Microscopy, and Wet Chemical Methods 4.5 Laboratory Quality Assurance, Chain of Custody, and Desorption Efficiency
5 Chapter 5: Biostatistics & Epidemiology
5.1 Lognormal Distributions and Exposure Data Statistics 5.2 Upper Confidence Limits (UCL95) and Compliance Decision Rules 5.3 Epidemiological Study Designs and Measures of Association 5.4 Sampling Strategy: Sample Size, Power, and Worker Selection
6 Chapter 6: Toxicology & Biological Monitoring
6.1 Dose-Response Relationships and Points of Departure 6.2 Toxicokinetics: Absorption, Distribution, Metabolism, and Elimination 6.3 Aerosol Deposition, Clearance, and Respiratory Tract Dosimetry 6.4 Hepatic, Renal, Neurologic, and Hematologic Target Organ Toxicity 6.5 Pulmonary Toxicology, Carcinogenicity, and Reproductive Hazards 6.6 OEL Frameworks, Classifications, and Excursion Limits 6.7 Chemical Mixtures and Extended Work-Shift OEL Adjustments 6.8 Biological Exposure Indices (BEIs) and Biomonitoring
7 Chapter 7: Biohazards & Indoor Environmental Quality
7.1 Mold, Fungi, and Microbial Contaminants 7.2 Infectious Agents, Bloodborne Pathogens, and Biosafety Levels 7.3 Indoor Environmental Quality (IEQ) Investigations 7.4 Sanitation, Potable Water, and Personal Hygiene Programs
8 Chapter 8: Community Exposure & Environmental Health
8.1 Clean Air Act Framework, NAAQS, and New Source Review 8.2 Hazardous Air Pollutants, CEMS, and EPA Reference Methods 8.3 Atmospheric Stability, Lapse Rates, and Plume Morphology 8.4 Gaussian Plume Modeling, Plume Rise, and Environmental Fate 8.5 HAZWOPER Scope, Mandates, and Training Tiers 8.6 Protection Levels, Site Zoning, Incident Command, and Decontamination 8.7 Water Pollution, Hazardous Waste, and Community Right-to-Know
9 Chapter 9: Health Risk Analysis & Hazard Communication
9.1 GHS Hazard Classification: Health and Physical Hazard Criteria 9.2 GHS Labels, Safety Data Sheets, and Trade Secret Rules 9.3 The AIHA Exposure Assessment Strategy and Similar Exposure Groups 9.4 Qualitative Exposure Profiling and the AIHA Risk Matrix 9.5 Quantitative Health Risk Characterization: HQ, HI, and ELCR 9.6 NIOSH Occupational Exposure Banding 9.7 Risk Communication and Reporting to Affected Parties
10 Chapter 10: Industrial Ventilation Principles & LEV Design
10.1 Elimination, Substitution, Isolation, Containment, and Process Change 10.2 LEV Hood Taxonomy and Capture Velocity Selection 10.3 Hood Airflow Equations, Entry Losses, and Hood Static Pressure 10.4 Particulate Transport Aerodynamics and Duct Sizing 10.5 Duct Friction, Fitting Losses, and System Balancing 10.6 Fan Categories and Pressure Dynamics Across the Fan 10.7 System Curves, the Fan Laws, and Density Corrections
11 Chapter 11: General Ventilation, Air Cleaning & Diagnostics
11.1 Dilution Ventilation Principles and Steady-State Modeling 11.2 Transient Purging and Air Distribution Geometry 11.3 Particulate Air Cleaning: Cyclones, Baghouses, Scrubbers, and ESPs 11.4 Gaseous Emission Control and Air Cleaner Selection 11.5 Ventilation System Troubleshooting and Testing
12 Chapter 12: Noise Measurement & Hearing Conservation
12.1 Acoustic Physics and Decibel Mathematics 12.2 Sound Propagation, Octave Bands, and Frequency Weighting 12.3 Noise Dose Metrics and OSHA versus ACGIH Criteria 12.4 Exchange Rates, Extended Shifts, and Dosimetry Field Protocols 12.5 Engineering Noise Controls and Hearing Protector Attenuation 12.6 Hearing Conservation Programs and Standard Threshold Shifts 12.7 Hand-Arm and Whole-Body Vibration
13 Chapter 13: Thermal Stress Assessment & Control
13.1 Wet Bulb Globe Temperature (WBGT) and Heat Stress Indices 13.2 Heat-Related Disorders, Acclimatization, and Work/Rest Regimens 13.3 Cold Stress Evaluation and Wind Chill
14 Chapter 14: Ionizing Radiation Protection
14.1 Ionizing Radiation Physics and Radioactive Decay Kinetics 14.2 Radiation Units, Radiobiology, and Health Effects 14.3 ALARA, Stay-Time, and the Inverse Square Law 14.4 Shielding Physics, Material Selection, and Gamma Constants 14.5 Radiation Detection Instruments and Spectrometry 14.6 Personnel Dosimetry, Dose Limits, and Contamination Surveys
15 Chapter 15: Non-Ionizing Radiation & Laser Safety
15.1 The Non-Ionizing Spectrum and Static/ELF Field Exposures 15.2 Radiofrequency and Microwave Exposure: SAR, Standards, and Surveys 15.3 Ultraviolet, Visible, and Infrared Radiation Hazards 15.4 Laser Safety Classifications and Optical Density Calculations 15.5 Illumination, Lighting Design, and Visual Performance
16 Chapter 16: Non-Engineering Controls & Personal Protective Equipment
16.1 Respiratory Protection Programs and Assigned Protection Factors 16.2 Maximum Use Concentration, Oxygen Deficiency, and Breathing Air 16.3 Particulate Filters, Sorbent Cartridges, and Change Schedules 16.4 Respirator Fit Testing Protocols 16.5 Chemical Protective Clothing and Dermal Exposure Control
17 Chapter 17: Ergonomics & Workstation Design
17.1 Soft-Tissue Biomechanics and WMSD Pathophysiology 17.2 Ergonomic Risk Factors and Their Interaction Effects 17.3 The Revised NIOSH Lifting Equation 17.4 RULA, REBA, the Strain Index, and the ACGIH HAL TLV 17.5 Anthropometry and Workstation Geometry 17.6 VDT Workstations, Hand Tool Design, and Administrative Ergonomics
18 Chapter 18: Work Environments & Industrial Processes
18.1 Welding Fume Emissions, Metal Fume Fever, and Cr(VI)/Manganese Toxicology 18.2 Foundry Operations and Hot Work Fire Prevention 18.3 Vapor Degreasing, Pickling, Electroplating, and Cyanide Baths 18.4 Spray Coatings, Isocyanates, and Semiconductor Manufacturing 18.5 Confined Spaces and High-Hazard Industrial Operations 18.6 Asbestos, Lead, and Silica: Regulated Substance Programs 18.7 Abrasive Blasting and Surface Preparation
19 Chapter 19: IH Program Management & Professional Ethics
19.1 The BGC Code of Ethics: Canons and Enforcement 19.2 Professional Liability, Standard of Care, and Expert Testimony 19.3 Occupational Health & Safety Management Systems (ISO 45001, ANSI Z10) 19.4 Exposure Records Access and Medical Surveillance 19.5 OSHA Injury and Illness Recordkeeping and Enforcement
12.6 Hearing Conservation Programs and Standard Threshold Shifts
Key Takeaways Explain This Topic AI
A hearing conservation programme is triggered at an 8-hour TWA of 85 dBA (the action level), while the OSHA PEL remains 90 dBA — enrolment and compliance thresholds are different numbers.
Required programme elements are monitoring, employee notification, observation of monitoring, audiometric testing, hearing protector provision and fitting, training, and recordkeeping.
A standard threshold shift is an average change of 10 dB or more at 2000, 3000, and 4000 Hz in either ear relative to baseline; age correction may be applied but is optional.
An STS becomes recordable on the OSHA 300 log when the total hearing level averaged over those frequencies is 25 dB or more above audiometric zero in the affected ear.
Last updated: August 2026
Hearing Conservation Programs and Standard Threshold Shifts
Engineering control reduces the hazard; the hearing conservation programme manages the residual risk and produces the audiometric evidence that the programme is or is not working. OSHA prescribes the elements of that programme and the arithmetic of a standard threshold shift.
1. OSHA Hearing Conservation Program (29 CFR 1910.95) Mandatory Elements
Whenever employee noise exposure equals or exceeds an 8-hour TWA of 85 dBA (50% dose or 85 dBA Action Level), the employer must implement a comprehensive Hearing Conservation Program. +-------------------------------------------------------------------------+
- | OSHA 29 CFR 1910.95 HEARING CONSERVATION PROGRAM |
- +-------------------------------------------------------------------------+
- | |
- | 1. EXPOSURE MONITORING: |
- | - Conduct representative 8-hr dosimetry (80 dBA threshold). |
- | - Re-monitor upon process, equipment, or control modifications. |
- | |
- | 2. AUDIOMETRIC TESTING (Free to workers): |
- | - Baseline Audiogram: Within 6 months of exposure (14 hr quiet). |
- | - Annual Audiograms: Compared against baseline for STS. |
- | |
- | 3. HEARING PROTECTORS: |
- | - Provided free of charge; minimum 2 types of plugs & 1 muff. |
- | - Mandatory wear for: TWA >= 90 dBA, or TWA >= 85 dBA if no baseline|
- | yet established, or if employee has experienced an STS. |
- | |
- | 4. EMPLOYEE TRAINING: |
- | - Annual training on noise hazards, HPD selection, fit, and testing.|
- | |
- | 5. RECORDKEEPING: |
- | - Noise measurements retained for AT LEAST 2 YEARS. |
- | - Audiometric test records retained for DURATION OF EMPLOYMENT. |
- +-------------------------------------------------------------------------+
- Audiometric Testing Program Requirements
Baseline Audiogram:
Must be established within 6 months of an employee's first exposure at or above the Action Level (85 dBA TWA), or within 1 year if using mobile test vans (workers must wear HPDs after 6 months until tested).
Mandatory 14-Hour Quiet Period: The baseline test must be preceded by at least 14 hours of quiet free from workplace noise to ensure temporary threshold shift (TTS) has resolved. Wearing hearing protectors with adequate attenuation is legally permitted to satisfy this 14-hour quiet period.
Annual Audiogram:
Tested at pure-tone frequencies: 500, 1000, 2000, 3000, 4000, 6000 Hz in both left and right ears.
Compared directly against the baseline audiogram to detect hearing deterioration.
Audiometer Calibration Schedule:
Daily Biological Check: Test a person with stable hearing; shift ≥ 10 dB requires acoustic calibration.
Annual Acoustic Calibration: Performed annually using an artificial ear/sound level meter.
Biannual Exhaustive Calibration: Full factory electronic recalibration every 2 years .
2. Standard Threshold Shift (STS) Determination and Follow-Up +-------------------------------------------------------------------------+
- | STANDARD THRESHOLD SHIFT (STS) AUDIOGRAM |
- +-------------------------------------------------------------------------+
- | |
- | Hearing Level (dB HL) |
- | 0 | |
- | 10 |---[ Baseline: 10 dB, 10 dB, 15 dB -> Avg = 11.7 dB ] |
- | 20 | |
- | 30 |---\- - - - - - - - - - - - - - - - - - - - - - - - - - - - |
- | 40 | \ [ Annual: 25 dB, 30 dB, 35 dB -> Avg = 30.0 dB ] |
- | 50 | \ |
- | 60 | v Shift = 30.0 - 11.7 = 18.3 dB (>= 10 dB -> STS!) |
- | +-------------------------------------------------------------- |
- | 500 Hz 1 kHz 2 kHz 3 kHz 4 kHz 6 kHz 8 kHz |
- +-------------------------------------------------------------------------+
- Standard Threshold Shift (STS) Definition
A Standard Threshold Shift (STS) is defined by OSHA 29 CFR 1910.95(g)(10) as: Average Shift ≥ 10.0 dB at 2 , 000 Hz , 3 , 000 Hz , and 4 , 000 Hz in either ear relative to baseline. \mathbf{\text{Average Shift } \ge 10.0\text{ dB at } 2,000\text{ Hz}, 3,000\text{ Hz},\text{ and } 4,000\text{ Hz} \text{ in either ear relative to baseline.}} Average Shift ≥ 10.0 dB at 2 , 000 Hz , 3 , 000 Hz , and 4 , 000 Hz in either ear relative to baseline. Shift = ( Δ HL 2000 + Δ HL 3000 + Δ HL 4000 ) 3 ≥ 10.0 dB \text{Shift} = \frac{(\Delta \text{HL}_{2000} + \Delta \text{HL}_{3000} + \Delta \text{HL}_{4000})}{3} \ge 10.0\text{ dB} Shift = 3 ( Δ HL 2000 + Δ HL 3000 + Δ HL 4000 ) ≥ 10.0 dB
Presbycusis Age Correction (OSHA Appendix F)
Normal age-related hearing loss ( presbycusis ) can be mathematically deducted from the annual audiogram using standardized values in OSHA 1910.95 Appendix F (stratified by age and sex).
If the age-corrected shift is < 10.0 dB, an STS has not occurred.
Mandatory Follow-Up Actions upon STS Detection
Retest Option: Employer may conduct an immediate or scheduled retest within 21 calendar days of the annual test. If the retest does not confirm the shift, the STS is negated.
Written Employee Notification: Employer must notify the affected employee in writing within 21 calendar days of the STS determination.
HPD Enforcement & Refitting:
Employees not currently wearing HPDs must be fitted with HPDs, trained in their use, and mandated to wear them .
Employees already wearing HPDs must be refitted, retrained , and provided with higher-attenuation HPDs if current protection is inadequate.
Clinical Referral: Refer employee for audiological or otological evaluation if ear pathology or medical conditions are suspected.
OSHA 300 Log Recordability (29 CFR 1904.10):
An STS must be recorded on the employer's OSHA Form 300 Log within 7 calendar days if all three of the following criteria are met:
Work-Related: The hearing loss is caused or aggravated by workplace noise exposure.
STS Confirmed: A confirmed STS (≥ 10 dB average shift at 2k, 3k, 4k Hz, with optional age correction) is identified in one or both ears.
Total Audiometric Hearing Level Threshold: The employee's current overall hearing level in the affected ear averages 25 dB or greater above audiometric zero across 2000, 3000, and 4000 Hz on the current audiogram.
- 3. Worked Step-by-Step Calculation Examples
- Worked Example 11.3.1: Room Reverberation and Noise Reduction via Sabine Formula
Problem: A plant stamping bay measures L = 60 ft, W = 40 ft, and H = 20 ft (Volume V = 48,000 ft³). The total internal surface area is S = 2(60× 40 + 60× 20 + 40× 20) = 8,800 ft². The unconditioned hard concrete walls, floor, and metal deck ceiling have an average acoustic absorption coefficient of α1 = 0.05.
Calculate the initial room absorption (A1) and reverberation time (T(60,1)).
If acoustic fiberglass baffles are suspended from the ceiling to add 2,200 Sabins of absorption (A2 = A1 + 2200), calculate the new reverberation time (T(60,2)).
Calculate the noise reduction (Δ Lrev) achieved in the reverberant sound field.
Solution Steps:
Calculate initial room absorption and reverberation time: A 1 = S × α 1 = 8 , 800 ft 2 × 0.05 = 440 Sabins A_1 = S \times \alpha_1 = 8,800\text{ ft}^2 \times 0.05 = 440\text{ Sabins} A 1 = S × α 1 = 8 , 800 ft 2 × 0.05 = 440 Sabins T 60 , 1 = 0.049 V A 1 = 0.049 × 48 , 000 440 = 2 , 352 440 = 5.35 seconds T_{60,1} = \frac{0.049 V}{A_1} = \frac{0.049 \times 48,000}{440} = \frac{2,352}{440} = \mathbf{5.35\text{ seconds}} T 60 , 1 = A 1 0.049 V = 440 0.049 × 48 , 000 = 440 2 , 352 = 5.35 seconds
Calculate new absorption and reverberation time with ceiling baffles: A 2 = A 1 + 2 , 200 = 440 + 2 , 200 = 2 , 640 Sabins A_2 = A_1 + 2,200 = 440 + 2,200 = 2,640\text{ Sabins} A 2 = A 1 + 2 , 200 = 440 + 2 , 200 = 2 , 640 Sabins T 60 , 2 = 0.049 × 48 , 000 2 , 640 = 2 , 352 2 , 640 = 0.89 seconds T_{60,2} = \frac{0.049 \times 48,000}{2,640} = \frac{2,352}{2,640} = \mathbf{0.89\text{ seconds}} T 60 , 2 = 2 , 640 0.049 × 48 , 000 = 2 , 640 2 , 352 = 0.89 seconds
Calculate reverberant sound level reduction (Δ L = 10 log10[A2 / A1]): Δ L = 10 log 10 ( 2 , 640 440 ) = 10 log 10 ( 6.0 ) = 10 × 0.77815 = 7.78 dB ≈ 7.8 dBA \Delta L = 10 \log_{10}\left( \frac{2,640}{440} \right) = 10 \log_{10}(6.0) = 10 \times 0.77815 = \mathbf{7.78\text{ dB} \approx 7.8\text{ dBA}} Δ L = 10 lo g 10 ( 440 2 , 640 ) = 10 lo g 10 ( 6.0 ) = 10 × 0.77815 = 7.78 dB ≈ 7.8 dBA
Result: Adding acoustic baffles reduces reverberation time from 5.35 s down to 0.89 s and attenuates reverberant field noise by 7.8 dBA .
Worked Example 11.3.2: Dual Hearing Protection Calculation and Protected Exposure
Problem: A boilermaker is exposed to continuous metal gouging noise at an ambient level of Lp = 104.0 dBA. The worker wears formable foam earplugs with a manufacturer labeled NRR = 31.0 dB combined with circumaural earmuffs with an NRR = 25.0 dB.
Calculate the OSHA Field Derated NRR for the dual protection combination.
Calculate the worker's estimated protected noise exposure level (Lprot).
Determine if the dual protection adequately protects the worker to below the OSHA PEL (90.0 dBA) and Action Level (85.0 dBA).
Solution Steps:
Calculate Dual Protection Field NRR:
Identify the higher NRR device: Earplugs (extNRR = 31.0 dB).
Apply OSHA derating to the higher device: Field NRRprimary = (31.0 - 7)/2 = 24.0/2 = 12.0 dB.
Add the standard 5.0 dB dual protection credit for the secondary device: Field NRR dual = 12.0 dB + 5.0 dB = 17.0 dB \text{Field NRR}_{\text{dual}} = 12.0\text{ dB} + 5.0\text{ dB} = \mathbf{17.0\text{ dB}} Field NRR dual = 12.0 dB + 5.0 dB = 17.0 dB
Calculate Protected Exposure Level (Lprot = Ambient dBA - Field NRRdual): L prot = 104.0 dBA − 17.0 dB = 87.0 dBA L_{\text{prot}} = 104.0\text{ dBA} - 17.0\text{ dB} = \mathbf{87.0\text{ dBA}} L prot = 104.0 dBA − 17.0 dB = 87.0 dBA
Evaluate Protection Adequacy:
Protected exposure is 87.0 dBA , which is below the OSHA PEL of 90.0 dBA (compliant for 8-hour shift).
Note: While compliant with the 90.0 dBA PEL, it remains above the 85.0 dBA Action Level, meaning the worker must remain enrolled in the Hearing Conservation Program.
Result: The derated dual protection provides 17.0 dB of effective attenuation, reducing worker exposure from 104.0 dBA to 87.0 dBA .
Worked Example 11.3.3: Evaluating Audiometric Test Data for STS with Age Correction
Problem: A 48-year-old male machinist receives an annual audiogram. His baseline audiogram (established at age 40) and current annual audiogram show the following pure-tone hearing threshold levels (HTL in dB HL) for the right ear:
Test Frequency Baseline HTL (Age 40) Annual HTL (Age 48) Appendix F Age Values (Age 40) Appendix F Age Values (Age 48)
- 2,000 Hz 10 dB 20 dB 3 dB 5 dB
- 3,000 Hz 15 dB 30 dB 6 dB 11 dB
- 4,000 Hz 15 dB 35 dB 9 dB 17 dB
Calculate the unadjusted average hearing threshold shift at 2k, 3k, and 4k Hz.
Calculate the age-corrected threshold shift using the OSHA Appendix F values.
Determine whether an OSHA Standard Threshold Shift (STS) has occurred.
Solution Steps:
Calculate unadjusted average shift:
- Shift at 2000 Hz: 20 - 10 = 10 dB
- Shift at 3000 Hz: 30 - 15 = 15 dB
Shift at 4000 Hz: 35 - 15 = 20 dB Unadjusted Shift = 10 + 15 + 20 3 = 45 3 = 15.0 dB \text{Unadjusted Shift} = \frac{10 + 15 + 20}{3} = \frac{45}{3} = \mathbf{15.0\text{ dB}} Unadjusted Shift = 3 10 + 15 + 20 = 3 45 = 15.0 dB
(Unadjusted shift of 15.0 dB ≥ 10.0 dB meets initial STS criteria) .
Apply OSHA Appendix F Presbycusis Age Correction:
Age correction factor (Age 48 value minus Age 40 value):
- At 2000 Hz: 5 - 3 = 2 dB
- At 3000 Hz: 11 - 6 = 5 dB
- At 4000 Hz: 17 - 9 = 8 dB
Age-corrected annual thresholds:
- At 2000 Hz: 20 - 2 = 18 dB → Corrected shift = 18 - 10 = 8 dB
- At 3000 Hz: 30 - 5 = 25 dB → Corrected shift = 25 - 15 = 10 dB
At 4000 Hz: 35 - 8 = 27 dB → Corrected shift = 27 - 15 = 12 dB Age-Corrected Average Shift = 8 + 10 + 12 3 = 30 3 = 10.0 dB \text{Age-Corrected Average Shift} = \frac{8 + 10 + 12}{3} = \frac{30}{3} = \mathbf{10.0\text{ dB}} Age-Corrected Average Shift = 3 8 + 10 + 12 = 3 30 = 10.0 dB
Determine STS Status:
The age-corrected average shift is exactly 10.0 dB . Because OSHA defines an STS as an average shift ≥ 10.0 dB, a confirmed Standard Threshold Shift has occurred .
Result: Even after applying full OSHA Appendix F age corrections, the employee exhibits an STS of 10.0 dB in the right ear, triggering mandatory written notification within 21 days and HPD refitting/retraining.