Study guide
12.2 Sound Propagation, Octave Bands, and Frequency Weighting
CIH Certified Industrial Hygienist Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: The CIH Exam and How to Use This Guide
1.1 CIH Exam Format, Scoring, and Test-Day Logistics 1.2 Eligibility, Application Windows, Fees, and Certification Maintenance 1.3 The BGC Blueprint, Subject Areas, and a Calculation-First Study Plan
2 Chapter 2: Basic Science & Calculations
2.1 Gas Laws and Vapor Calculations 2.2 Unit Conversions: ppm, mg/m³, and Standard Temperature/Pressure 2.3 Fluid Mechanics and Airflow Fundamentals
3 Chapter 3: Air Sampling & Instrumentation
3.1 Active and Passive Air Sampling Strategies 3.2 Particulate and Aerosol Sampling 3.3 Direct-Reading Instruments and Calibration
4 Chapter 4: Analytical Chemistry & Lab Methods
4.1 Gas Chromatography and Mass Spectrometry 4.2 High-Performance Liquid Chromatography and Ion Chromatography 4.3 Spectroscopy and Elemental Analysis 4.4 Gravimetric, Microscopy, and Wet Chemical Methods 4.5 Laboratory Quality Assurance, Chain of Custody, and Desorption Efficiency
5 Chapter 5: Biostatistics & Epidemiology
5.1 Lognormal Distributions and Exposure Data Statistics 5.2 Upper Confidence Limits (UCL95) and Compliance Decision Rules 5.3 Epidemiological Study Designs and Measures of Association 5.4 Sampling Strategy: Sample Size, Power, and Worker Selection
6 Chapter 6: Toxicology & Biological Monitoring
6.1 Dose-Response Relationships and Points of Departure 6.2 Toxicokinetics: Absorption, Distribution, Metabolism, and Elimination 6.3 Aerosol Deposition, Clearance, and Respiratory Tract Dosimetry 6.4 Hepatic, Renal, Neurologic, and Hematologic Target Organ Toxicity 6.5 Pulmonary Toxicology, Carcinogenicity, and Reproductive Hazards 6.6 OEL Frameworks, Classifications, and Excursion Limits 6.7 Chemical Mixtures and Extended Work-Shift OEL Adjustments 6.8 Biological Exposure Indices (BEIs) and Biomonitoring
7 Chapter 7: Biohazards & Indoor Environmental Quality
7.1 Mold, Fungi, and Microbial Contaminants 7.2 Infectious Agents, Bloodborne Pathogens, and Biosafety Levels 7.3 Indoor Environmental Quality (IEQ) Investigations 7.4 Sanitation, Potable Water, and Personal Hygiene Programs
8 Chapter 8: Community Exposure & Environmental Health
8.1 Clean Air Act Framework, NAAQS, and New Source Review 8.2 Hazardous Air Pollutants, CEMS, and EPA Reference Methods 8.3 Atmospheric Stability, Lapse Rates, and Plume Morphology 8.4 Gaussian Plume Modeling, Plume Rise, and Environmental Fate 8.5 HAZWOPER Scope, Mandates, and Training Tiers 8.6 Protection Levels, Site Zoning, Incident Command, and Decontamination 8.7 Water Pollution, Hazardous Waste, and Community Right-to-Know
9 Chapter 9: Health Risk Analysis & Hazard Communication
9.1 GHS Hazard Classification: Health and Physical Hazard Criteria 9.2 GHS Labels, Safety Data Sheets, and Trade Secret Rules 9.3 The AIHA Exposure Assessment Strategy and Similar Exposure Groups 9.4 Qualitative Exposure Profiling and the AIHA Risk Matrix 9.5 Quantitative Health Risk Characterization: HQ, HI, and ELCR 9.6 NIOSH Occupational Exposure Banding 9.7 Risk Communication and Reporting to Affected Parties
10 Chapter 10: Industrial Ventilation Principles & LEV Design
10.1 Elimination, Substitution, Isolation, Containment, and Process Change 10.2 LEV Hood Taxonomy and Capture Velocity Selection 10.3 Hood Airflow Equations, Entry Losses, and Hood Static Pressure 10.4 Particulate Transport Aerodynamics and Duct Sizing 10.5 Duct Friction, Fitting Losses, and System Balancing 10.6 Fan Categories and Pressure Dynamics Across the Fan 10.7 System Curves, the Fan Laws, and Density Corrections
11 Chapter 11: General Ventilation, Air Cleaning & Diagnostics
11.1 Dilution Ventilation Principles and Steady-State Modeling 11.2 Transient Purging and Air Distribution Geometry 11.3 Particulate Air Cleaning: Cyclones, Baghouses, Scrubbers, and ESPs 11.4 Gaseous Emission Control and Air Cleaner Selection 11.5 Ventilation System Troubleshooting and Testing
12 Chapter 12: Noise Measurement & Hearing Conservation
12.1 Acoustic Physics and Decibel Mathematics 12.2 Sound Propagation, Octave Bands, and Frequency Weighting 12.3 Noise Dose Metrics and OSHA versus ACGIH Criteria 12.4 Exchange Rates, Extended Shifts, and Dosimetry Field Protocols 12.5 Engineering Noise Controls and Hearing Protector Attenuation 12.6 Hearing Conservation Programs and Standard Threshold Shifts 12.7 Hand-Arm and Whole-Body Vibration
13 Chapter 13: Thermal Stress Assessment & Control
13.1 Wet Bulb Globe Temperature (WBGT) and Heat Stress Indices 13.2 Heat-Related Disorders, Acclimatization, and Work/Rest Regimens 13.3 Cold Stress Evaluation and Wind Chill
14 Chapter 14: Ionizing Radiation Protection
14.1 Ionizing Radiation Physics and Radioactive Decay Kinetics 14.2 Radiation Units, Radiobiology, and Health Effects 14.3 ALARA, Stay-Time, and the Inverse Square Law 14.4 Shielding Physics, Material Selection, and Gamma Constants 14.5 Radiation Detection Instruments and Spectrometry 14.6 Personnel Dosimetry, Dose Limits, and Contamination Surveys
15 Chapter 15: Non-Ionizing Radiation & Laser Safety
15.1 The Non-Ionizing Spectrum and Static/ELF Field Exposures 15.2 Radiofrequency and Microwave Exposure: SAR, Standards, and Surveys 15.3 Ultraviolet, Visible, and Infrared Radiation Hazards 15.4 Laser Safety Classifications and Optical Density Calculations 15.5 Illumination, Lighting Design, and Visual Performance
16 Chapter 16: Non-Engineering Controls & Personal Protective Equipment
16.1 Respiratory Protection Programs and Assigned Protection Factors 16.2 Maximum Use Concentration, Oxygen Deficiency, and Breathing Air 16.3 Particulate Filters, Sorbent Cartridges, and Change Schedules 16.4 Respirator Fit Testing Protocols 16.5 Chemical Protective Clothing and Dermal Exposure Control
17 Chapter 17: Ergonomics & Workstation Design
17.1 Soft-Tissue Biomechanics and WMSD Pathophysiology 17.2 Ergonomic Risk Factors and Their Interaction Effects 17.3 The Revised NIOSH Lifting Equation 17.4 RULA, REBA, the Strain Index, and the ACGIH HAL TLV 17.5 Anthropometry and Workstation Geometry 17.6 VDT Workstations, Hand Tool Design, and Administrative Ergonomics
18 Chapter 18: Work Environments & Industrial Processes
18.1 Welding Fume Emissions, Metal Fume Fever, and Cr(VI)/Manganese Toxicology 18.2 Foundry Operations and Hot Work Fire Prevention 18.3 Vapor Degreasing, Pickling, Electroplating, and Cyanide Baths 18.4 Spray Coatings, Isocyanates, and Semiconductor Manufacturing 18.5 Confined Spaces and High-Hazard Industrial Operations 18.6 Asbestos, Lead, and Silica: Regulated Substance Programs 18.7 Abrasive Blasting and Surface Preparation
19 Chapter 19: IH Program Management & Professional Ethics
19.1 The BGC Code of Ethics: Canons and Enforcement 19.2 Professional Liability, Standard of Care, and Expert Testimony 19.3 Occupational Health & Safety Management Systems (ISO 45001, ANSI Z10) 19.4 Exposure Records Access and Medical Surveillance 19.5 OSHA Injury and Illness Recordkeeping and Enforcement
12.2 Sound Propagation, Octave Bands, and Frequency Weighting
Key Takeaways Explain This Topic AI
In a free field, sound pressure level drops 6 dB per doubling of distance from a point source and 3 dB per doubling from a line source.
Octave bands are defined by an upper band edge twice the lower edge, with standard centre frequencies of 31.5, 63, 125, 250, 500, 1000, 2000, 4000, 8000, and 16000 Hz.
A-weighting de-emphasises low frequencies to approximate the ear response at conversational levels and is used for hearing damage risk; C-weighting is nearly flat and is used for peak and impulse measurement and for HPD attenuation calculations.
SLOW response uses a 1-second time constant and FAST 125 ms; peak measurements are unweighted or C-weighted and are not the same as the maximum RMS level.
Last updated: August 2026
Sound Propagation, Octave Bands, and Frequency Weighting
Decibel arithmetic tells you how to combine levels. Propagation and frequency analysis tell you what level to expect at a worker position and which part of the spectrum is doing the damage — the two things an engineering noise control decision actually depends on.
1. Geometric Acoustic Spreading and Inverse Square Law
In a free acoustic field (an open space free of reflecting boundaries), sound energy propagates outward from the source, spreading its power across an expanding geometric wavefront surface area. +-------------------------------------------------------------------------+
- | POINT SOURCE VS. LINE SOURCE PROPAGATION |
- +-------------------------------------------------------------------------+
- | |
- | A. SPHERICAL POINT SOURCE (3D Spreading): |
- | - Area of sphere = 4πr² |
- | - Doubling distance spreads energy over 4× the surface area. |
- | - Attenuation rate = -6 dB per distance doubling! |
- | |
- | Source (*) ===> Area A (r=1) ====> Area 4A (r=2) |
- | Lp1 Lp2 = Lp1 - 6 dB |
- | |
- | B. CYLINDRICAL LINE SOURCE (2D Spreading): |
- | - Area of cylinder = 2πrL |
- | - Doubling distance spreads energy over 2× the surface area. |
- | - Attenuation rate = -3 dB per distance doubling! |
- | |
- | Line [=======] ====> Area A (r=1) ====> Area 2A (r=2) |
- | Lp1 Lp2 = Lp1 - 3 dB |
- +-------------------------------------------------------------------------+
- Point Sources (Spherical Wave Propagation)
For an isolated, compact machine whose dimensions are small relative to measurement distance and wavelength (a point source ), sound radiates as expanding concentric spheres (A = 4π r²): L p 2 = L p 1 − 20 log 10 ( r 2 r 1 ) L_{p2} = L_{p1} - 20 \log_{10}\left(\frac{r_2}{r_1}\right) L p 2 = L p 1 − 20 lo g 10 ( r 1 r 2 ) Point Source Rule: Sound pressure level drops by 6 dB per doubling of distance. \mathbf{\text{Point Source Rule: Sound pressure level drops by } 6\text{ dB per doubling of distance.}} Point Source Rule: Sound pressure level drops by 6 dB per doubling of distance.
Line Sources (Cylindrical Wave Propagation)
For continuous, elongated acoustic emitters such as high-velocity industrial pneumatic conveyor lines, continuous overhead duct runs, piping headers, or dense continuous highway traffic (a line source ), sound radiates as expanding concentric cylinders (A = 2π r L): L p 2 = L p 1 − 10 log 10 ( r 2 r 1 ) L_{p2} = L_{p1} - 10 \log_{10}\left(\frac{r_2}{r_1}\right) L p 2 = L p 1 − 10 lo g 10 ( r 1 r 2 ) Line Source Rule: Sound pressure level drops by 3 dB per doubling of distance. \mathbf{\text{Line Source Rule: Sound pressure level drops by } 3\text{ dB per doubling of distance.}} Line Source Rule: Sound pressure level drops by 3 dB per doubling of distance.
Directivity Factor (Q) and Directivity Index (DI)
Real-world industrial machines operate near reflecting room surfaces (floors, walls, corners), which constrain sound radiation into partial spheres, concentrating sound intensity: +-------------------------------------------------------------------------+
- | ACOUSTIC DIRECTIVITY FACTOR (Q) |
- +-------------------------------------------------------------------------+
- | |
- | Q = 1: Full Sphere (Free space / suspended) -> DI = 0 dB |
- | Q = 2: Hemisphere (Machine on hard floor) -> DI = +3 dB |
- | Q = 4: Quarter Sphere (Floor-wall junction) -> DI = +6 dB |
- | Q = 8: Octant (Machine in trihedral corner) -> DI = +9 dB |
- +-------------------------------------------------------------------------+
The relationship between Sound Power Level (Lw), directivity (Q), distance (r in meters), and Sound Pressure Level (Lp) in a free field is: L p = L w + 10 log 10 ( Q 4 π r 2 ) L_p = L_w + 10 \log_{10}\left( \frac{Q}{4 \pi r^2} \right) L p = L w + 10 lo g 10 ( 4 π r 2 Q ) D I = 10 log 10 ( Q ) DI = 10 \log_{10}(Q) D I = 10 lo g 10 ( Q )
2. Frequency Analysis and Octave Bands
Human auditory sensitivity and physical engineering control mechanics (such as barrier transmission loss and silencer design) vary dramatically across the acoustic frequency spectrum (20 Hz to 20,000 Hz). Broadband sound is divided into standardized frequency intervals known as Octave Bands and 1/3-Octave Bands .
Octave Band Center Frequencies and Bandwidths
An octave band represents a frequency interval where the upper cutoff frequency (f2) is exactly twice the lower cutoff frequency (f1): f 2 = 2 × f 1 f_2 = 2 \times f_1 f 2 = 2 × f 1
The geometric center frequency (fc) is the geometric mean of the cutoff frequencies: f c = f 1 × f 2 ⟹ f 1 = f c 2 = 0.7071 f c , f 2 = f c × 2 = 1.4142 f c f_c = \sqrt{f_1 \times f_2} \implies f_1 = \frac{f_c}{\sqrt{2}} = 0.7071 f_c, \quad f_2 = f_c \times \sqrt{2} = 1.4142 f_c f c = f 1 × f 2 ⟹ f 1 = 2 f c = 0.7071 f c , f 2 = f c × 2 = 1.4142 f c Bandwidth ( Δ f ) = f 2 − f 1 = 1.4142 f c − 0.7071 f c = 0.7071 f c \text{Bandwidth (}\Delta f\text{)} = f_2 - f_1 = 1.4142 f_c - 0.7071 f_c = 0.7071 f_c Bandwidth ( Δ f ) = f 2 − f 1 = 1.4142 f c − 0.7071 f c = 0.7071 f c
- Standard Octave Band Center Frequency (fc) Lower Band Edge (f1) Upper Band Edge (f2) Bandwidth (Δ f)
- 31.5 Hz 22.3 Hz 44.5 Hz 22.2 Hz
- 63 Hz 44.5 Hz 89.1 Hz 44.6 Hz
- 125 Hz 89.1 Hz 177 Hz 87.9 Hz
- 250 Hz 177 Hz 354 Hz 177 Hz
- 500 Hz 354 Hz 707 Hz 353 Hz
- 1,000 Hz 707 Hz 1,414 Hz 707 Hz
- 2,000 Hz 1,414 Hz 2,828 Hz 1,414 Hz
- 4,000 Hz 2,828 Hz 5,657 Hz 2,829 Hz
- 8,000 Hz 5,657 Hz 11,314 Hz 5,657 Hz
- 16,000 Hz 11,314 Hz 22,627 Hz 11,313 Hz
1/3-Octave Bands: For pinpointing pure-tone whine, blade-pass frequencies, or resonant structural vibration, each octave band is split into three sub-bands where f2 / f1 = 2(1/3) = ∛2 ≈ 1.2599.
3. Frequency Weighting Networks: A, C, and Z Weightings
The human auditory system does not possess a flat frequency response. The human ear is biologically tuned to be most sensitive in the speech intelligibility frequencies between 1,000 Hz and 4,000 Hz (peaking around the ear canal resonance at 3,000--4,000 Hz) and is remarkably insensitive to low-frequency acoustic energy. +-------------------------------------------------------------------------+
- | FREQUENCY WEIGHTING PROFILES (A, C, Z) |
- +-------------------------------------------------------------------------+
- | |
- | Gain (dB) |
- | +10 | .. C-Weighting (Flat) |
- | 0 |---------------------------------''-------------------- Z-Flat |
- | -10 | .---. |
- | -20 | .' '. A-Weighting (40-phon contour) |
- | -30 | .' |
- | -40 | .----------' |
- | -50 | .' |
- | +-------------------------------------------------------------- |
- | 31.5 63 125 250 500 1k 2k 4k 8k 16k (Hz) |
- +-------------------------------------------------------------------------+
- The Standard Weighting Networks
A-Weighting (extdBA):
Designed to mimic the 40-phon equal-loudness contour (Fletcher-Munson curve).
Heavily penalizes (attenuates) low frequencies (e.g., -39.4 dB at 31.5 Hz; -16.1 dB at 125 Hz) and slightly boosts frequencies around 2.5 kHz.
Regulatory Mandate: Mandated by OSHA (29 CFR 1910.95), ACGIH, and NIOSH for all occupational noise exposure monitoring, dose calculations, and hearing conservation risk assessments.
C-Weighting (extdBC):
Designed to mimic the 100-phon equal-loudness contour for high-intensity acoustic fields.
Provides an essentially flat response across the audible spectrum (31.5 Hz to 8 kHz), attenuating only -3.0 dB at 31.5 Hz and -3.0 dB at 8 kHz.
Primary Uses: Peak/impact noise measurement (140 dBC ceiling), evaluating low-frequency noise (e.g., diesel engines, large fans), and calculating real-world Hearing Protection Device (HPD) attenuation.
Z-Weighting (extdBZ / Linear / Flat):
"Zero-weighting" (IEC 61672-1), providing a flat, unattenuated acoustic response from 10 Hz to 20 kHz ± 1.5 dB .
Primary Uses: Engineering frequency analysis, octave band sound power characterization, and acoustic enclosure design.
Standard Octave Band Weighting Correction Factors
- Octave Band Center Frequency (fc) A-Weighting Correction (Δ LA) C-Weighting Correction (Δ LC)
- 31.5 Hz -39.4 dB -3.0 dB
- 63 Hz -26.2 dB -0.8 dB
- 125 Hz -16.1 dB -0.2 dB
- 250 Hz -8.6 dB 0.0 dB
- 500 Hz -3.2 dB 0.0 dB
- 1,000 Hz 0.0 dB 0.0 dB
- 2,000 Hz +1.2 dB -0.2 dB
- 4,000 Hz +1.0 dB -0.8 dB
- 8,000 Hz -1.1 dB -3.0 dB
- 16,000 Hz -6.6 dB -8.5 dB
Converting Octave Bands to Overall dBA: To calculate the overall A-weighted sound level from octave band measurements: add the A-weighting correction Δ LA to each octave band level, then sum the resulting levels logarithmically.
4. Instrument Dynamic Response Settings and Standards
Sound Level Meters ( SLMs ) and personal noise dosimeters incorporate standardized dynamic ballistic response settings that govern how the meter's detector averages fluctuating acoustic signals over time. +-------------------------------------------------------------------------+
- | INSTRUMENT DYNAMIC TIME CONSTANTS |
- +-------------------------------------------------------------------------+
- | |
- | 1. SLOW RESPONSE (τ = 1000 ms = 1.0 s): |
- | - Heavily damped exponential time-averaging. |
- | - Smooths out fluctuating sound levels to yield a steady reading. |
- | - MANDATED BY OSHA 1910.95 for occupational noise surveys! |
- | |
- | 2. FAST RESPONSE (τ = 125 ms = 1/8 s): |
- | - Rapid response tracking transient sound level variations. |
- | - Used for identifying cycling machinery and brief task events. |
- | |
- | 3. PEAK / IMPULSE DETECTOR (Rise Time < 35 µs to 100 µs): |
- | - Captures instantaneous unweighted or C-weighted pressure peaks. |
- | - Required for impact noise (punch presses, explosions, gunshots). |
- +-------------------------------------------------------------------------+
- Dynamic Response Specifications
Slow Response: Exponential time constant τ = 1,000 ms (1.0 second). Mandated by OSHA for occupational compliance monitoring because it dampens visual meter fluctuations, enabling reproducible human reading.
Fast Response: Exponential time constant τ = 125 ms (1/8 second). Four times faster than slow response; tracks rapidly changing acoustic events.
Peak Response: Rise time constant < 35 microseconds (µs) (ANSI S1.43 / IEC 61672) to capture the true instantaneous acoustic peak pressure (Lpeak), holding the peak value for decay evaluation. Mandated by OSHA for verifying compliance with the 140 dB peak sound pressure limit .
Sound Level Meter (SLM) Classifications (ANSI S1.4 / IEC 61672)
Class 1 / Type 1 (Precision): Laboratory and precision field grade instrument with tight tolerance limits (± 1.0 dB across 10 Hz to 20 kHz). Required for complex acoustic research, legal testimony, and environmental boundary compliance.
Class 2 / Type 2 (General Purpose): General field survey grade instrument with broader tolerance limits (± 2.0 dB across 100 Hz to 8 kHz). Accepted by OSHA for routine workplace occupational noise surveys and dosimeter compliance.
- 5. Worked Step-by-Step Calculation Examples
- Worked Example 11.1.1: Logarithmic Summation of Multiple Machine Sources
Problem: An industrial hygiene survey in a machining shop measures the sound pressure levels of four machines operating independently at a workstation:
- Machine A (Stamping press): 91.0 dBA
- Machine B (CNC milling center): 88.0 dBA
- Machine C (Hydraulic power pack): 88.0 dBA
- Machine D (Parts tumbler): 82.0 dBA
Calculate the total combined sound pressure level (Ltotal) when all four machines operate simultaneously using the exact logarithmic addition formula.
Cross-verify the calculation using the CIH rule-of-thumb shortcut addition method.
Solution Steps:
Apply the exact logarithmic summation formula (Ltotal = 10 log10[Σ 10(Li / 10)]): 10 91.0 / 10 = 10 9.10 = 1 , 258 , 925 , 412 10^{91.0 / 10} = 10^{9.10} = 1,258,925,412 1 0 91.0/10 = 1 0 9.10 = 1 , 258 , 925 , 412 10 88.0 / 10 = 10 8.80 = 630 , 957 , 344 10^{88.0 / 10} = 10^{8.80} = 630,957,344 1 0 88.0/10 = 1 0 8.80 = 630 , 957 , 344 10 88.0 / 10 = 10 8.80 = 630 , 957 , 344 10^{88.0 / 10} = 10^{8.80} = 630,957,344 1 0 88.0/10 = 1 0 8.80 = 630 , 957 , 344 10 82.0 / 10 = 10 8.20 = 158 , 489 , 319 10^{82.0 / 10} = 10^{8.20} = 158,489,319 1 0 82.0/10 = 1 0 8.20 = 158 , 489 , 319 ∑ 10 L i / 10 = 1 , 258 , 925 , 412 + 630 , 957 , 344 + 630 , 957 , 344 + 158 , 489 , 319 = 2 , 679 , 329 , 419 \sum 10^{L_i / 10} = 1,258,925,412 + 630,957,344 + 630,957,344 + 158,489,319 = 2,679,329,419 ∑ 1 0 L i /10 = 1 , 258 , 925 , 412 + 630 , 957 , 344 + 630 , 957 , 344 + 158 , 489 , 319 = 2 , 679 , 329 , 419 L total = 10 log 10 ( 2 , 679 , 329 , 419 ) = 10 × 9.4280 = 94.28 dBA ≈ 94.3 dBA L_{\text{total}} = 10 \log_{10}(2,679,329,419) = 10 \times 9.4280 = 94.28\text{ dBA} \approx \mathbf{94.3\text{ dBA}} L total = 10 lo g 10 ( 2 , 679 , 329 , 419 ) = 10 × 9.4280 = 94.28 dBA ≈ 94.3 dBA
Shortcut Verification:
Combine two identical 88.0 dBA sources: 88.0 + 3.0 = 91.0 dBA.
Combine this with Machine A (91.0 dBA): 91.0 + 91.0 = 91.0 + 3.0 = 94.0 dBA.
Combine 94.0 dBA with Machine D (82.0 dBA): Difference is 94.0 - 82.0 = 12.0 dB (difference ≥ 10 dB → +0.0 dB). Combined total = 94.0 dBA (exact 94.3 dBA).
Result: The total workstation noise level with all machines active is 94.3 dBA .
Worked Example 11.1.2: Correcting for Background Ambient Noise
Problem: An industrial hygienist tests a newly installed exhaust blower. With the blower running, the sound level meter measures a total sound pressure level of Ltotal = 89.0 dBA. When the blower is switched off, the ambient plant background noise level is measured at Lbg = 85.0 dBA. What is the true acoustic sound pressure level generated by the exhaust blower alone (Lblower)?
Solution Steps:
Identify the measured levels: Ltotal = 89.0 dBA, Lbg = 85.0 dBA.
Evaluate difference: Δ L = 89.0 - 85.0 = 4.0 dB. (Since Δ L ≥ 3 dB, background correction is valid).
Apply the logarithmic subtraction formula (Lsource = 10 log10[10^Ltotal/10 - 10^Lbg/10]): 10 89.0 / 10 = 10 8.90 = 794 , 328 , 235 10^{89.0 / 10} = 10^{8.90} = 794,328,235 1 0 89.0/10 = 1 0 8.90 = 794 , 328 , 235 10 85.0 / 10 = 10 8.50 = 316 , 227 , 766 10^{85.0 / 10} = 10^{8.50} = 316,227,766 1 0 85.0/10 = 1 0 8.50 = 316 , 227 , 766 10 L blower / 10 = 794 , 328 , 235 − 316 , 227 , 766 = 478 , 100 , 469 10^{L_{\text{blower}}/10} = 794,328,235 - 316,227,766 = 478,100,469 1 0 L blower /10 = 794 , 328 , 235 − 316 , 227 , 766 = 478 , 100 , 469 L blower = 10 log 10 ( 478 , 100 , 469 ) = 10 × 8.6795 = 86.795 dBA ≈ 86.8 dBA L_{\text{blower}} = 10 \log_{10}(478,100,469) = 10 \times 8.6795 = 86.795\text{ dBA} \approx \mathbf{86.8\text{ dBA}} L blower = 10 lo g 10 ( 478 , 100 , 469 ) = 10 × 8.6795 = 86.795 dBA ≈ 86.8 dBA
Shortcut Verification: For a 4 dB difference (89 - 85), the table instructs subtracting 2.0 dB from Ltotal: 89.0 - 2.0 = 87.0 dBA (in close agreement with 86.8 dBA).
Result: The true sound pressure level generated exclusively by the exhaust blower is 86.8 dBA .
Worked Example 11.1.3: Inverse Square Law Propagation for a Point Source
Problem: A high-pressure air compressor operates as an omnidirectional point source on an open concrete slab (Q = 2, hemispherical radiation). At a distance r1 = 3.0 meters from the compressor, the sound pressure level is measured as Lp1 = 96.0 dBA.
Calculate the sound pressure level (Lp2) at a boundary fence line located r2 = 24.0 meters away, assuming free-field conditions.
Determine the total Sound Power Level (Lw) of the compressor.
Solution Steps:
Apply the Point Source Inverse Square Law (Lp2 = Lp1 - 20 log10[r2 / r1]): r 2 r 1 = 24.0 m 3.0 m = 8.0 \frac{r_2}{r_1} = \frac{24.0\text{ m}}{3.0\text{ m}} = 8.0 r 1 r 2 = 3.0 m 24.0 m = 8.0 20 log 10 ( 8.0 ) = 20 × 0.90309 = 18.06 dB 20 \log_{10}(8.0) = 20 \times 0.90309 = 18.06\text{ dB} 20 lo g 10 ( 8.0 ) = 20 × 0.90309 = 18.06 dB L p 2 = 96.0 dBA − 18.06 dB = 77.94 dBA ≈ 77.9 dBA L_{p2} = 96.0\text{ dBA} - 18.06\text{ dB} = 77.94\text{ dBA} \approx \mathbf{77.9\text{ dBA}} L p 2 = 96.0 dBA − 18.06 dB = 77.94 dBA ≈ 77.9 dBA
(Shortcut check: Distance doubles from 3 to 6 m [-6 dB], 6 to 12 m [-6 dB], and 12 to 24 m [-6 dB]. Total attenuation = 3 × 6 = 18 dB → 96 - 18 = 78 dBA) .
Calculate Sound Power Level (Lw = Lp - 10 log10[Q / (4 π r²)]): L p = 96.0 dB at r = 3.0 m , Q = 2 L_p = 96.0\text{ dB at } r = 3.0\text{ m}, \quad Q = 2 L p = 96.0 dB at r = 3.0 m , Q = 2 Q 4 π r 2 = 2 4 π ( 3.0 ) 2 = 2 113.097 = 0.017684 \frac{Q}{4 \pi r^2} = \frac{2}{4 \pi (3.0)^2} = \frac{2}{113.097} = 0.017684 4 π r 2 Q = 4 π ( 3.0 ) 2 2 = 113.097 2 = 0.017684 10 log 10 ( 0.017684 ) = 10 × ( − 1.7524 ) = − 17.52 dB 10 \log_{10}(0.017684) = 10 \times (-1.7524) = -17.52\text{ dB} 10 lo g 10 ( 0.017684 ) = 10 × ( − 1.7524 ) = − 17.52 dB L w = 96.0 − ( − 17.52 ) = 96.0 + 17.52 = 113.5 dB L_w = 96.0 - (-17.52) = 96.0 + 17.52 = \mathbf{113.5\text{ dB}} L w = 96.0 − ( − 17.52 ) = 96.0 + 17.52 = 113.5 dB
Result: The sound level at 24 meters is 77.9 dBA , and the compressor's sound power level is 113.5 dB .