Study guide
16.5 Chemical Protective Clothing and Dermal Exposure Control
CIH Certified Industrial Hygienist Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: The CIH Exam and How to Use This Guide
1.1 CIH Exam Format, Scoring, and Test-Day Logistics 1.2 Eligibility, Application Windows, Fees, and Certification Maintenance 1.3 The BGC Blueprint, Subject Areas, and a Calculation-First Study Plan
2 Chapter 2: Basic Science & Calculations
2.1 Gas Laws and Vapor Calculations 2.2 Unit Conversions: ppm, mg/m³, and Standard Temperature/Pressure 2.3 Fluid Mechanics and Airflow Fundamentals
3 Chapter 3: Air Sampling & Instrumentation
3.1 Active and Passive Air Sampling Strategies 3.2 Particulate and Aerosol Sampling 3.3 Direct-Reading Instruments and Calibration
4 Chapter 4: Analytical Chemistry & Lab Methods
4.1 Gas Chromatography and Mass Spectrometry 4.2 High-Performance Liquid Chromatography and Ion Chromatography 4.3 Spectroscopy and Elemental Analysis 4.4 Gravimetric, Microscopy, and Wet Chemical Methods 4.5 Laboratory Quality Assurance, Chain of Custody, and Desorption Efficiency
5 Chapter 5: Biostatistics & Epidemiology
5.1 Lognormal Distributions and Exposure Data Statistics 5.2 Upper Confidence Limits (UCL95) and Compliance Decision Rules 5.3 Epidemiological Study Designs and Measures of Association 5.4 Sampling Strategy: Sample Size, Power, and Worker Selection
6 Chapter 6: Toxicology & Biological Monitoring
6.1 Dose-Response Relationships and Points of Departure 6.2 Toxicokinetics: Absorption, Distribution, Metabolism, and Elimination 6.3 Aerosol Deposition, Clearance, and Respiratory Tract Dosimetry 6.4 Hepatic, Renal, Neurologic, and Hematologic Target Organ Toxicity 6.5 Pulmonary Toxicology, Carcinogenicity, and Reproductive Hazards 6.6 OEL Frameworks, Classifications, and Excursion Limits 6.7 Chemical Mixtures and Extended Work-Shift OEL Adjustments 6.8 Biological Exposure Indices (BEIs) and Biomonitoring
7 Chapter 7: Biohazards & Indoor Environmental Quality
7.1 Mold, Fungi, and Microbial Contaminants 7.2 Infectious Agents, Bloodborne Pathogens, and Biosafety Levels 7.3 Indoor Environmental Quality (IEQ) Investigations 7.4 Sanitation, Potable Water, and Personal Hygiene Programs
8 Chapter 8: Community Exposure & Environmental Health
8.1 Clean Air Act Framework, NAAQS, and New Source Review 8.2 Hazardous Air Pollutants, CEMS, and EPA Reference Methods 8.3 Atmospheric Stability, Lapse Rates, and Plume Morphology 8.4 Gaussian Plume Modeling, Plume Rise, and Environmental Fate 8.5 HAZWOPER Scope, Mandates, and Training Tiers 8.6 Protection Levels, Site Zoning, Incident Command, and Decontamination 8.7 Water Pollution, Hazardous Waste, and Community Right-to-Know
9 Chapter 9: Health Risk Analysis & Hazard Communication
9.1 GHS Hazard Classification: Health and Physical Hazard Criteria 9.2 GHS Labels, Safety Data Sheets, and Trade Secret Rules 9.3 The AIHA Exposure Assessment Strategy and Similar Exposure Groups 9.4 Qualitative Exposure Profiling and the AIHA Risk Matrix 9.5 Quantitative Health Risk Characterization: HQ, HI, and ELCR 9.6 NIOSH Occupational Exposure Banding 9.7 Risk Communication and Reporting to Affected Parties
10 Chapter 10: Industrial Ventilation Principles & LEV Design
10.1 Elimination, Substitution, Isolation, Containment, and Process Change 10.2 LEV Hood Taxonomy and Capture Velocity Selection 10.3 Hood Airflow Equations, Entry Losses, and Hood Static Pressure 10.4 Particulate Transport Aerodynamics and Duct Sizing 10.5 Duct Friction, Fitting Losses, and System Balancing 10.6 Fan Categories and Pressure Dynamics Across the Fan 10.7 System Curves, the Fan Laws, and Density Corrections
11 Chapter 11: General Ventilation, Air Cleaning & Diagnostics
11.1 Dilution Ventilation Principles and Steady-State Modeling 11.2 Transient Purging and Air Distribution Geometry 11.3 Particulate Air Cleaning: Cyclones, Baghouses, Scrubbers, and ESPs 11.4 Gaseous Emission Control and Air Cleaner Selection 11.5 Ventilation System Troubleshooting and Testing
12 Chapter 12: Noise Measurement & Hearing Conservation
12.1 Acoustic Physics and Decibel Mathematics 12.2 Sound Propagation, Octave Bands, and Frequency Weighting 12.3 Noise Dose Metrics and OSHA versus ACGIH Criteria 12.4 Exchange Rates, Extended Shifts, and Dosimetry Field Protocols 12.5 Engineering Noise Controls and Hearing Protector Attenuation 12.6 Hearing Conservation Programs and Standard Threshold Shifts 12.7 Hand-Arm and Whole-Body Vibration
13 Chapter 13: Thermal Stress Assessment & Control
13.1 Wet Bulb Globe Temperature (WBGT) and Heat Stress Indices 13.2 Heat-Related Disorders, Acclimatization, and Work/Rest Regimens 13.3 Cold Stress Evaluation and Wind Chill
14 Chapter 14: Ionizing Radiation Protection
14.1 Ionizing Radiation Physics and Radioactive Decay Kinetics 14.2 Radiation Units, Radiobiology, and Health Effects 14.3 ALARA, Stay-Time, and the Inverse Square Law 14.4 Shielding Physics, Material Selection, and Gamma Constants 14.5 Radiation Detection Instruments and Spectrometry 14.6 Personnel Dosimetry, Dose Limits, and Contamination Surveys
15 Chapter 15: Non-Ionizing Radiation & Laser Safety
15.1 The Non-Ionizing Spectrum and Static/ELF Field Exposures 15.2 Radiofrequency and Microwave Exposure: SAR, Standards, and Surveys 15.3 Ultraviolet, Visible, and Infrared Radiation Hazards 15.4 Laser Safety Classifications and Optical Density Calculations 15.5 Illumination, Lighting Design, and Visual Performance
16 Chapter 16: Non-Engineering Controls & Personal Protective Equipment
16.1 Respiratory Protection Programs and Assigned Protection Factors 16.2 Maximum Use Concentration, Oxygen Deficiency, and Breathing Air 16.3 Particulate Filters, Sorbent Cartridges, and Change Schedules 16.4 Respirator Fit Testing Protocols 16.5 Chemical Protective Clothing and Dermal Exposure Control
17 Chapter 17: Ergonomics & Workstation Design
17.1 Soft-Tissue Biomechanics and WMSD Pathophysiology 17.2 Ergonomic Risk Factors and Their Interaction Effects 17.3 The Revised NIOSH Lifting Equation 17.4 RULA, REBA, the Strain Index, and the ACGIH HAL TLV 17.5 Anthropometry and Workstation Geometry 17.6 VDT Workstations, Hand Tool Design, and Administrative Ergonomics
18 Chapter 18: Work Environments & Industrial Processes
18.1 Welding Fume Emissions, Metal Fume Fever, and Cr(VI)/Manganese Toxicology 18.2 Foundry Operations and Hot Work Fire Prevention 18.3 Vapor Degreasing, Pickling, Electroplating, and Cyanide Baths 18.4 Spray Coatings, Isocyanates, and Semiconductor Manufacturing 18.5 Confined Spaces and High-Hazard Industrial Operations 18.6 Asbestos, Lead, and Silica: Regulated Substance Programs 18.7 Abrasive Blasting and Surface Preparation
19 Chapter 19: IH Program Management & Professional Ethics
19.1 The BGC Code of Ethics: Canons and Enforcement 19.2 Professional Liability, Standard of Care, and Expert Testimony 19.3 Occupational Health & Safety Management Systems (ISO 45001, ANSI Z10) 19.4 Exposure Records Access and Medical Surveillance 19.5 OSHA Injury and Illness Recordkeeping and Enforcement
16.5 Chemical Protective Clothing and Dermal Exposure Control
Key Takeaways Explain This Topic AI
Chemical protective clothing (CPC) performance is governed by ASTM F739 for Permeation (molecular diffusion rate and Breakthrough Detection Time at 0.1 µg/cm²·min), ASTM D471 for Degradation (physical material breakdown), and ASTM F903 for Penetration (macroscopic seam/closure leakage).
Polymer selection requires chemical matching: Nitrile excels against petroleum fuels and oils; Neoprene resists acids, caustics, and alcohols; Butyl rubber uniquely resists polar organics (ketones, esters) and toxic gases; Viton resists chlorinated and aromatic hydrocarbons; PVA provides an extreme solvent barrier but is water-soluble.
The 'Skin' notation in OEL tables signals significant potential contribution to systemic body burden via cutaneous absorption, mandating dermal controls and biological monitoring regardless of airborne concentration levels.
Barrier laminates (e.g., EVOH/PE multilayer films) provide universal chemical resistance for unknown mixtures and HAZMAT emergencies at the expense of stiffness, reduced dexterity, and mechanical vulnerability.
Administrative controls—including clean/dirty change room transitions, mandatory industrial laundering, and strict prohibition of taking contaminated workwear home—prevent take-home toxic exposures.
Last updated: August 2026
Chemical Protective Clothing and Dermal Exposure Control
Dermal exposure to hazardous chemicals represents a major occupational health pathway that can cause localized cutaneous injury (chemical burns, contact dermatitis, sensitization) and severe systemic toxicity via percutaneous absorption into the bloodstream. In the hierarchy of industrial hygiene controls, when engineering containment (e.g., glove boxes, closed-loop transfers, splash baffles) is insufficient, Chemical Protective Clothing (CPC) and administrative controls must be implemented.
Selecting CPC requires understanding the transport phenomena through polymer barriers: permeation , degradation , and penetration . Misinterpreting these physical mechanisms can lead to catastrophic chemical breakthrough, dermatitis, or systemic poisoning.
1. CPC Performance Metrics: Permeation, Degradation, and Penetration +-------------------------------------------------------------------------+
- | PERMEATION VS. DEGRADATION VS. PENETRATION |
- +-------------------------------------------------------------------------+
- | |
- | A. PERMEATION (ASTM F739) - Molecular Level: |
- | Chemical molecules dissolve into the outer polymer matrix, diffuse |
- | through the molecular chains, and desorb into the interior skin. |
- | |
- | [Chemical Liquid] ===> ( Sorption ) ===> [ Diffusion ] ===> ( Skin )|
- | |
- | B. DEGRADATION (ASTM D471 / F1296) - Physical Property Damage: |
- | Chemical contact physically alters the polymer: swelling, |
- | softening, hardening, shrinking, embrittlement, or dissolution. |
- | |
- | C. PENETRATION (ASTM F903) - Macroscopic Flow: |
- | Bulk liquid or aerosol leaks through pinholes, stitched seams, |
- | zippers, tears, or porous weave imperfections. |
- +-------------------------------------------------------------------------+
- 1. Permeation (ASTM F739 Standard Test Method)
Permeation is the non-porous molecular transport of a liquid or gaseous chemical through intact protective clothing material. It occurs in three continuous sequential steps: (1) Sorption of chemical molecules into the outer contacted surface; (2) Diffusion of absorbed molecules through the polymer bulk matrix governed by Fick's First Law (J = -D dC/dx); and (3) Desorption of molecules from the interior surface into the microclimate adjacent to the worker's skin.
Breakthrough Detection Time (BDT / Normalized Breakthrough Time): The elapsed time between initial chemical contact on the outer surface and the moment the permeation rate reaches the standardized threshold of 0.1 µg/(cm²·min) (or 0.05 µg/(cm²·min) in European EN 374 standards).
Steady-State Permeation Rate (SSPR): The constant, equilibrium mass flux of chemical diffusing through the material per unit area per unit time (expressed in µg/(cm²·min) or mg/(m²·s)).
Cumulative Permeation Mass: The total mass of chemical permeated per unit surface area over a defined exposure duration (e.g., µg/cm² over 8 hours).
2. Degradation (ASTM D471 / ASTM F1296)
Degradation is the deleterious change in one or more physical or mechanical properties of a protective clothing material caused by chemical exposure. Manifestations include swelling, weight gain, softening, loss of tensile strength, cracking, stiffening, shrinkage, or complete dissolution.
Fundamental Rule: Degradation and permeation are independent phenomena . A glove material may show zero visible degradation (retaining perfect physical appearance and flexibility) while permitting rapid, dangerous molecular permeation of a toxicant within minutes! Conversely, a material may degrade physically while exhibiting high permeation resistance.
3. Penetration (ASTM F903 Standard Test Method)
Penetration is the macroscopic movement of a chemical through closures, stitched seams, porous weaves, buttonholes, zippers, punctures, or pinhole defects in a protective clothing material without molecular diffusion. Penetration testing subjects materials to liquid challenge under hydrostatic pressure (1--2 psig) to detect liquid passage.
2. Chemical Protective Polymer Selection Matrix
No single polymer provides universal protection against all chemical classes. Selecting protective clothing requires matching the chemical family, polarity, and molecular structure of the hazard to the polymer matrix. +-------------------------------------------------------------------------+
- | POLYMER COMPATIBILITY SUMMARY MATRIX |
- +-------------------------------------------------------------------------+
- | |
- | Polymer Material | Primary Strengths | Critical Vulnerabilities|
- +---------------------+--------------------------+-------------------------+
- | 1. Nitrile (NBR) | Petroleum fuels, oils, | Ketones (MEK/acetone), |
- | | aliphatics, greases | strong oxidizing acids |
- | 2. Neoprene (CR) | Acids, caustics, bases, | Chlorinated solvents, |
- | | alcohols, moderate oils | aromatic hydrocarbons |
- | 3. Butyl Rubber | Polar organics (ketones, | Aliphatics, aromatics, |
- | | esters), toxic gases | chlorinated solvents |
- | 4. Viton (FKM) | Chlorinated solvents, | Ketones, esters, |
- | | aromatics (benzene/tol) | amines |
- | 5. PVA (Polyvinyl | Aromatic & chlorinated | WATER-SOLUBLE! Destroyed|
- | Alcohol) | solvents, heavy organics | by water, alcohols |
- | 6. Natural Rubber | Dilute acids/bases, salts| Petroleum hydrocarbons, |
- | (Latex) | alcohols, ketones | oils; allergen risk |
- | 7. Barrier Laminate| Universal chemical range | Poor dexterity, stiff, |
- | (4H / Silver) | (unknown mixtures/HAZMAT)| low tear resistance |
- +-------------------------------------------------------------------------+
- Detailed Chemical Class & Polymer Specifics
Nitrile (Acrylonitrile-Butadiene Copolymer, NBR):
Best For: Petroleum distillates, gasoline, diesel, kerosene, aliphatic hydrocarbons (hexane, heptane), hydraulic fluids, animal fats, and general cutting oils. Excellent puncture and abrasion resistance.
Poor For: Ketones (acetone, MEK), strong oxidizing acids (nitric acid), and chlorinated hydrocarbons.
Neoprene (Polychloroprene, CR):
Best For: Broad chemical spectrum including moderate mineral acids, alkaline caustics (sodium hydroxide, potassium hydroxide), alcohols, glycol ethers, organic acids, and moderate petroleum fractions.
Poor For: Aromatic hydrocarbons (benzene, toluene), chlorinated solvents (methylene chloride, TCE), and ketones.
Butyl Rubber (Isobutylene-Isoprene Copolymer, IIR):
Best For: Polar organic compounds —specifically ketones (acetone, methyl ethyl ketone, cyclohexanone), esters (ethyl acetate, butyl acetate), aldehydes, corrosive acid gases (Cl2, SO2, NH3), and chemical warfare agents (mustard, sarin). Outstanding gas-tight impermeability.
Poor For: Non-polar solvents, aliphatic hydrocarbons, aromatic solvents (benzene/toluene), and halogenated hydrocarbons.
Viton / Fluoroelastomer (Vinylidene Fluoride-Hexafluoropropylene, FKM):
Best For: Halogenated and chlorinated hydrocarbons (methylene chloride, trichloroethylene, perchloroethylene, chloroform), aromatic hydrocarbons (benzene, toluene, xylene), and concentrated aggressive mineral acids.
Poor For: Ketones (acetone, MEK cause extreme swelling), esters, aldehydes, and organic amines.
Polyvinyl Alcohol (PVA):
Best For: Exceptional, impermeable barrier against chlorinated solvents, aromatics (benzene, xylene), and heavy industrial solvents.
Critical Vulnerability: Water Soluble. PVA is completely dissolved and destroyed by water, aqueous chemical solutions, and low-molecular-weight alcohols. It can never be used in moist environments or for aqueous operations.
Natural Rubber (Latex, Polyisoprene, NR):
Best For: Dilute aqueous solutions of acids, bases, salts, and low-toxicity alcohols. High elasticity and tactile sensitivity.
Poor For: Petroleum distillates, oils, greases, organic solvents. Carries a high risk of Type I IgE-mediated latex protein allergy .
Barrier Laminates (e.g., Silver Shield / 4H, Tychem TK):
Construction: Multi-layer micro-coextruded films (e.g., Ethylene Vinyl Alcohol [EVOH] laminated between high-density polyethylene [PE] layers).
Best For: Universal chemical resistance across almost all hazardous chemical classes; standard selection for HAZMAT emergency response, unknown chemical spill response, and complex multi-solvent mixtures.
Disadvantages: Non-elastic, zero stretch, stiff, poor dexterity/ergonomics; requires inner/outer protective work gloves to prevent mechanical punctures.
3. Dermal Exposure Assessment & The 'Skin' Notation
In occupational exposure criteria (ACGIH TLVs, OSHA PELs, NIOSH RELs), certain chemical substances carry a designated 'Skin' Notation (e.g., Benzene [Skin], Toluene [Skin], Phenol [Skin], Organophosphate pesticides [Skin]). +-------------------------------------------------------------------------+
- | THE ACGIH / OSHA "SKIN" NOTATION |
- +-------------------------------------------------------------------------+
- | |
- | DEFINITION: |
- | Indicates that dermal absorption through skin, mucous membranes, or |
- | eyes contributes SIGNIFICANTLY to the total systemic body burden. |
- | |
- | CRITICAL IMPLICATIONS: |
- | - Airborne exposure monitoring ALONE is insufficient to ensure worker |
- | safety. Air levels may be well below the PEL/TLV while severe toxic |
- | systemic poisoning occurs via skin absorption! |
- | - Mandates chemical protective clothing (CPC), dermal work practices, |
- | and Biological Exposure Indices (BEIs) monitoring. |
- +-------------------------------------------------------------------------+
- Factors Influencing Percutaneous Absorption
Lipid-Water Partition Coefficient (log Kow): Moderate lipophilicity (log Kow approx 1 text to 3) facilitates transcellular diffusion across the lipid-rich stratum corneum and subsequent partitioning into the aqueous viable epidermis.
Molecular Weight: Substances with MW < 500 Da penetrate human skin readily; large macromolecules (> 1,000 Da) exhibit negligible intact stratum corneum penetration.
Skin Integrity & Hydration: Damaged, abraded, burned, or hydrated/macerated skin exhibits up to 10× higher permeability.
Anatomical Site: Permeability varies dramatically across body locations: Scrotum (40×) > Forehead/Jaw (4--6×) > Back/Abdomen (2×) > Forearm/Palm (1×) > Plantar Sole (0.1×).
Dermal Sampling and Biological Monitoring
Dermal Patch Samplers: Standardized absorbent alpha-cellulose or cotton pads placed on specific anatomical zones under/over clothing to quantify surface deposition rate (µg/cm²).
Skin Wipe Sampling: Solvents or surfactant-wetted pads used to remove surface chemical residues from hands and skin (e.g., OSHA Method for lead or aromatic amines).
Fluorescent Tracing: Non-toxic optical tracers mixed into process chemicals and visualized under UV-A black light to audit glove leaks and cross-contamination during doffing.
Biological Monitoring (BEIs): The ultimate industrial hygiene gold standard for assessing combined inhalation and dermal dose. Measuring parent compounds or metabolites in urine or blood (e.g., urinary S-phenylmercapturic acid for benzene, urinary mandelic acid for styrene, blood lead).
4. Administrative and Work Practice Controls
While PPE acts as a physical barrier, administrative controls alter work patterns, standard operating procedures, and facility policies to minimize chemical contact and eliminate cross-contamination. +-------------------------------------------------------------------------+
- | ADMINISTRATIVE DERMAL CONTROLS SPECTRUM |
- +-------------------------------------------------------------------------+
- | |
- | 1. Job Rotation & Task Duration: Reduce cumulative exposure duration |
- | and manage thermal heat stress inside impermeable protective suits. |
- | |
- | 2. Work Practice Protocols: Use long-handled tools, automated solvent |
- | dispensers, and anti-splash baffles to eliminate direct contact. |
- | |
- | 3. Clean vs. Dirty Change Facilities: "Two-Locker" architecture with |
- | intervening shower decontamination to prevent cross-contamination. |
- | |
- | 4. Strict Take-Home Toxic Controls: Mandatory industrial laundering; |
- | prohibiting workers from taking contaminated workwear home! |
- +-------------------------------------------------------------------------+
- Industrial Hygiene Facility Controls
Clean and Dirty Change Rooms: Facilities handling regulated toxic agents (lead, asbestos, beryllium, carcinogenic aromatic amines) must provide separate clean change rooms (for street clothes) and dirty change rooms (for contaminated PPE) separated by mandatory shower and hygiene stations.
Take-Home Toxin Prevention: Contaminated protective clothing must never be removed from the facility by workers for home laundering. Secondary family exposures to toxic dusts (lead, asbestos, beryllium) have historically caused severe pediatric poisoning and mesothelioma.
Commercial Industrial Laundering: Contaminated clothing must be sealed in impermeable, labeled bags and laundered by specialized commercial facilities equipped with wastewater treatment and hazard warning protocols.
Personal Hygiene Policies: Strict prohibition of eating, drinking, smoking, chewing tobacco, or applying cosmetics in chemical work areas; mandatory hand and face washing prior to break periods.
- 5. Worked Step-by-Step Calculation Examples
- Worked Example 15.3.1: Permeation Flux and Cumulative Dermal Dose Modeling
Problem: A chemical worker's protective gloves are exposed to continuous liquid methyl ethyl ketone (MEK) during manual cleaning.
Glove surface area in contact with solvent = A = 400 cm².
ASTM F739 test data for the selected glove material indicates a Breakthrough Detection Time BDT = 45 minutes and a Steady-State Permeation Rate SSPR = 1.2 µg/(cm²·min).
The worker performs the task continuously for a total shift duration of ttotal = 240 minutes (4 hours).
Calculate the total cumulative mass (Mperm, in milligrams) of MEK that permeates through the gloves to the worker's skin.
Solution Steps:
Determine the active steady-state permeation duration (t_ textperm):
Permeation begins reaching the skin after the breakthrough time (textBDT). Δ t perm = t total − BDT = 240 min − 45 min = 195 minutes \Delta t_{\text{perm}} = t_{\text{total}} - \text{BDT} = 240\text{ min} - 45\text{ min} = 195\text{ minutes} Δ t perm = t total − BDT = 240 min − 45 min = 195 minutes
Calculate cumulative permeated mass (Mperm): M perm = SSPR × A × Δ t perm M_{\text{perm}} = \text{SSPR} \times A \times \Delta t_{\text{perm}} M perm = SSPR × A × Δ t perm M perm = 1.2 μ g / ( cm 2 ⋅ min ) × 400 cm 2 × 195 min M_{\text{perm}} = 1.2\ \mu\text{g}/(\text{cm}^2\cdot\text{min}) \times 400\text{ cm}^2 \times 195\text{ min} M perm = 1.2 μ g / ( cm 2 ⋅ min ) × 400 cm 2 × 195 min M perm = 480 μ g/min × 195 min = 93 , 600 μ g = 93.6 mg M_{\text{perm}} = 480\ \mu\text{g/min} \times 195\text{ min} = 93,600\ \mu\text{g} = 93.6\text{ mg} M perm = 480 μ g/min × 195 min = 93 , 600 μ g = 93.6 mg
Industrial Hygiene Conclusion: Over 93.6 mg of MEK permeates through the gloves directly onto the skin. The glove must be replaced with a material with > 240 min breakthrough time (e.g., Butyl Rubber) or work practices must enforce glove changes every 30 minutes.
Worked Example 15.3.2: Chemical Protective Glove Selection for a Complex Mixture
Problem: A chemical formulation operation utilizes a solvent blend consisting of 60% Methylene Chloride (dichloromethane) and 40% Toluene. An operator proposes using standard Nitrile gloves.
Evaluate the compatibility of Nitrile and recommend the appropriate CPC polymer.
Solution Steps:
Analyze Chemical Families:
Methylene chloride: Halogenated / Chlorinated hydrocarbon (extreme permeation rate through most standard elastomers).
Toluene: Aromatic hydrocarbon .
Evaluate Nitrile Performance:
Nitrile exhibits poor resistance to both chlorinated solvents (breakthrough in < 5 minutes) and aromatic solvents (< 15 minutes). Nitrile is strictly unacceptable .
Evaluate Alternative Polymers:
Butyl Rubber: Poor for aromatics and chlorinated solvents.
Neoprene: Poor for chlorinated and aromatic solvents.
PVA (Polyvinyl Alcohol): Excellent barrier against both methylene chloride and toluene, provided the system contains zero water.
Viton: Superior resistance to chlorinated solvents and aromatics.
Barrier Laminate (Silver Shield / 4H): Multi-layer EVOH/PE laminate provides > 4 hours breakthrough against both solvents.
Recommendation: Specify Viton gloves (or Silver Shield barrier laminates with outer heavy-duty work gloves for mechanical durability).
Worked Example 15.3.3: Evaluating Dermal Absorption and Biomonitoring
Problem: An industrial hygienist conducts personal air sampling on a degreasing line operator handling trichloroethylene (TCE). The 8-hour TWA air concentration is 4.5 ppm (well below the ACGIH TLV-TWA of 10 ppm). However, end-of-shift biological monitoring reveals urinary trichloroacetic acid (TCA) of 25 mg/L (exceeding the BEI of 15 mg/L). TCE carries a "Skin" notation.
Explain the discrepancy and identify the necessary control actions.
Solution Steps:
Identify the Exposure Pathway Discrepancy:
Airborne exposure (4.5 ppm) is compliant with inhalation OELs (< 10 ppm).
The elevated urinary biomarker (25 mg/L > 15 mg/L BEI) proves excessive internal systemic body burden.
Because TCE has a "Skin" notation , the worker is absorbing significant chemical doses cutaneously through direct hand contact, glove breakthrough, or contaminated workwear.
Corrective Control Actions:
Audit glove compatibility (replace leaking or degraded gloves with Viton or Silver Shield).
Implement impermeable forearm sleeves and aprons.
Institute mandatory handwashing and clean/dirty change room protocols.