Study guide

15.3 Ultraviolet, Visible, and Infrared Radiation Hazards

CIH Certified Industrial Hygienist Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: The CIH Exam and How to Use This Guide

1.1 CIH Exam Format, Scoring, and Test-Day Logistics 1.2 Eligibility, Application Windows, Fees, and Certification Maintenance 1.3 The BGC Blueprint, Subject Areas, and a Calculation-First Study Plan

2 Chapter 2: Basic Science & Calculations

2.1 Gas Laws and Vapor Calculations 2.2 Unit Conversions: ppm, mg/m³, and Standard Temperature/Pressure 2.3 Fluid Mechanics and Airflow Fundamentals

3 Chapter 3: Air Sampling & Instrumentation

3.1 Active and Passive Air Sampling Strategies 3.2 Particulate and Aerosol Sampling 3.3 Direct-Reading Instruments and Calibration

4 Chapter 4: Analytical Chemistry & Lab Methods

4.1 Gas Chromatography and Mass Spectrometry 4.2 High-Performance Liquid Chromatography and Ion Chromatography 4.3 Spectroscopy and Elemental Analysis 4.4 Gravimetric, Microscopy, and Wet Chemical Methods 4.5 Laboratory Quality Assurance, Chain of Custody, and Desorption Efficiency

5 Chapter 5: Biostatistics & Epidemiology

5.1 Lognormal Distributions and Exposure Data Statistics 5.2 Upper Confidence Limits (UCL95) and Compliance Decision Rules 5.3 Epidemiological Study Designs and Measures of Association 5.4 Sampling Strategy: Sample Size, Power, and Worker Selection

6 Chapter 6: Toxicology & Biological Monitoring

6.1 Dose-Response Relationships and Points of Departure 6.2 Toxicokinetics: Absorption, Distribution, Metabolism, and Elimination 6.3 Aerosol Deposition, Clearance, and Respiratory Tract Dosimetry 6.4 Hepatic, Renal, Neurologic, and Hematologic Target Organ Toxicity 6.5 Pulmonary Toxicology, Carcinogenicity, and Reproductive Hazards 6.6 OEL Frameworks, Classifications, and Excursion Limits 6.7 Chemical Mixtures and Extended Work-Shift OEL Adjustments 6.8 Biological Exposure Indices (BEIs) and Biomonitoring

7 Chapter 7: Biohazards & Indoor Environmental Quality

7.1 Mold, Fungi, and Microbial Contaminants 7.2 Infectious Agents, Bloodborne Pathogens, and Biosafety Levels 7.3 Indoor Environmental Quality (IEQ) Investigations 7.4 Sanitation, Potable Water, and Personal Hygiene Programs

8 Chapter 8: Community Exposure & Environmental Health

8.1 Clean Air Act Framework, NAAQS, and New Source Review 8.2 Hazardous Air Pollutants, CEMS, and EPA Reference Methods 8.3 Atmospheric Stability, Lapse Rates, and Plume Morphology 8.4 Gaussian Plume Modeling, Plume Rise, and Environmental Fate 8.5 HAZWOPER Scope, Mandates, and Training Tiers 8.6 Protection Levels, Site Zoning, Incident Command, and Decontamination 8.7 Water Pollution, Hazardous Waste, and Community Right-to-Know

9 Chapter 9: Health Risk Analysis & Hazard Communication

9.1 GHS Hazard Classification: Health and Physical Hazard Criteria 9.2 GHS Labels, Safety Data Sheets, and Trade Secret Rules 9.3 The AIHA Exposure Assessment Strategy and Similar Exposure Groups 9.4 Qualitative Exposure Profiling and the AIHA Risk Matrix 9.5 Quantitative Health Risk Characterization: HQ, HI, and ELCR 9.6 NIOSH Occupational Exposure Banding 9.7 Risk Communication and Reporting to Affected Parties

10 Chapter 10: Industrial Ventilation Principles & LEV Design

10.1 Elimination, Substitution, Isolation, Containment, and Process Change 10.2 LEV Hood Taxonomy and Capture Velocity Selection 10.3 Hood Airflow Equations, Entry Losses, and Hood Static Pressure 10.4 Particulate Transport Aerodynamics and Duct Sizing 10.5 Duct Friction, Fitting Losses, and System Balancing 10.6 Fan Categories and Pressure Dynamics Across the Fan 10.7 System Curves, the Fan Laws, and Density Corrections

11 Chapter 11: General Ventilation, Air Cleaning & Diagnostics

11.1 Dilution Ventilation Principles and Steady-State Modeling 11.2 Transient Purging and Air Distribution Geometry 11.3 Particulate Air Cleaning: Cyclones, Baghouses, Scrubbers, and ESPs 11.4 Gaseous Emission Control and Air Cleaner Selection 11.5 Ventilation System Troubleshooting and Testing

12 Chapter 12: Noise Measurement & Hearing Conservation

12.1 Acoustic Physics and Decibel Mathematics 12.2 Sound Propagation, Octave Bands, and Frequency Weighting 12.3 Noise Dose Metrics and OSHA versus ACGIH Criteria 12.4 Exchange Rates, Extended Shifts, and Dosimetry Field Protocols 12.5 Engineering Noise Controls and Hearing Protector Attenuation 12.6 Hearing Conservation Programs and Standard Threshold Shifts 12.7 Hand-Arm and Whole-Body Vibration

13 Chapter 13: Thermal Stress Assessment & Control

13.1 Wet Bulb Globe Temperature (WBGT) and Heat Stress Indices 13.2 Heat-Related Disorders, Acclimatization, and Work/Rest Regimens 13.3 Cold Stress Evaluation and Wind Chill

14 Chapter 14: Ionizing Radiation Protection

14.1 Ionizing Radiation Physics and Radioactive Decay Kinetics 14.2 Radiation Units, Radiobiology, and Health Effects 14.3 ALARA, Stay-Time, and the Inverse Square Law 14.4 Shielding Physics, Material Selection, and Gamma Constants 14.5 Radiation Detection Instruments and Spectrometry 14.6 Personnel Dosimetry, Dose Limits, and Contamination Surveys

15 Chapter 15: Non-Ionizing Radiation & Laser Safety

15.1 The Non-Ionizing Spectrum and Static/ELF Field Exposures 15.2 Radiofrequency and Microwave Exposure: SAR, Standards, and Surveys 15.3 Ultraviolet, Visible, and Infrared Radiation Hazards 15.4 Laser Safety Classifications and Optical Density Calculations 15.5 Illumination, Lighting Design, and Visual Performance

16 Chapter 16: Non-Engineering Controls & Personal Protective Equipment

16.1 Respiratory Protection Programs and Assigned Protection Factors 16.2 Maximum Use Concentration, Oxygen Deficiency, and Breathing Air 16.3 Particulate Filters, Sorbent Cartridges, and Change Schedules 16.4 Respirator Fit Testing Protocols 16.5 Chemical Protective Clothing and Dermal Exposure Control

17 Chapter 17: Ergonomics & Workstation Design

17.1 Soft-Tissue Biomechanics and WMSD Pathophysiology 17.2 Ergonomic Risk Factors and Their Interaction Effects 17.3 The Revised NIOSH Lifting Equation 17.4 RULA, REBA, the Strain Index, and the ACGIH HAL TLV 17.5 Anthropometry and Workstation Geometry 17.6 VDT Workstations, Hand Tool Design, and Administrative Ergonomics

18 Chapter 18: Work Environments & Industrial Processes

18.1 Welding Fume Emissions, Metal Fume Fever, and Cr(VI)/Manganese Toxicology 18.2 Foundry Operations and Hot Work Fire Prevention 18.3 Vapor Degreasing, Pickling, Electroplating, and Cyanide Baths 18.4 Spray Coatings, Isocyanates, and Semiconductor Manufacturing 18.5 Confined Spaces and High-Hazard Industrial Operations 18.6 Asbestos, Lead, and Silica: Regulated Substance Programs 18.7 Abrasive Blasting and Surface Preparation

19 Chapter 19: IH Program Management & Professional Ethics

19.1 The BGC Code of Ethics: Canons and Enforcement 19.2 Professional Liability, Standard of Care, and Expert Testimony 19.3 Occupational Health & Safety Management Systems (ISO 45001, ANSI Z10) 19.4 Exposure Records Access and Medical Surveillance 19.5 OSHA Injury and Illness Recordkeeping and Enforcement

15.3 Ultraviolet, Visible, and Infrared Radiation Hazards

Key Takeaways Explain This Topic AI

Optical radiation spans wavelengths from 100 nm (vacuum UV) to 1 mm (far-IR), with biological damage mechanisms governed strictly by photon energy and tissue absorption depth.

The ACGIH UV TLV establishes a peak ocular/skin sensitivity threshold of 3.0 mJ/cm² (30 J/m²) at 270 nm, with permissible exposure time calculated as t_max = 0.003 / E_eff seconds based on the spectral weighting function S(λ).

Photokeratitis ('welder's flash' or arc eye) is an acute, painful superficial corneal injury caused primarily by UV-B and UV-C radiation with a characteristic 6 to 12 hour latent onset.

The retinal hazard region spans 400 to 1400 nm (visible light and IR-A), where the eye's refractive optics focus incident energy onto the retina with an optical concentration gain of approximately 100,000 times.

Welding filter shade numbers are determined by the luminous transmittance formula: Shade Number = (7/3) log₁₀(1/T) + 1, providing simultaneous attenuation against UV actinic damage, intense visible glare, and infrared thermal cataractogenesis.

Last updated: August 2026

Ultraviolet, Visible, and Infrared Radiation Hazards

Optical radiation encompasses the ultraviolet (UV), visible light, and infrared (IR) portions of the electromagnetic spectrum, spanning wavelengths from 100 nm to 1 mm . In occupational environments—including welding operations, foundries, glassworks, UV curing, semiconductor photolithography, and germicidal disinfection—workers are routinely exposed to broadband optical sources. Because optical radiation is absorbed primarily by superficial tissues, the eye and the skin represent the critical target organs. Evaluating these hazards requires an understanding of photobiological mechanisms, wavelength-dependent absorption depths, the ACGIH spectral weighting function (S(λ)), and optical protective equipment selection.

1. Optical Radiation Spectrum and Ocular Tissue Penetration

The biological consequence of optical radiation depends fundamentally on photon wavelength , which dictates whether incident energy is absorbed photochemically or converted thermally, as well as the anatomical depth of penetration into the eye and skin. +---------------------------------------------------------------------------------------------------------+

  • | OPTICAL RADIATION SPECTRUM & OCULAR TARGETS |
  • | |
  • | Band: [ UV-C ] [ UV-B ] [ UV-A ] [ Visible Light ] [ IR-A (Near) ] [ IR-B ] [ IR-C ] |
  • | Wavelength: 100-280 nm 280-315 nm 315-400 nm 400-700 nm 700-1400 nm 1.4-3.0 µm 3.0 µm-1mm|
  • | Target: Cornea & Cornea & Lens Retina (Focused) Retina & Lens Cornea & Cornea |
  • | Conjunctiva Conjunctiva (Fluorescence) (Macula/Cones) (Thermal Burn & Aqueous (Thermal |
  • | (Keratitis) (Welder's) (Cataracts) (Blue Light Hazard) Cataracts) (Keratitis) Keratopathy|
  • +---------------------------------------------------------------------------------------------------------+
  • The Retinal Hazard Region (400 nm to 1400 nm)

The human eye acts as an exceptional optical focusing system. The cornea and crystalline lens are transparent to wavelengths between 400 nm and 1400 nm (visible light and near-infrared IR-A). When a collimated or distant beam enters the pupil, the refractive power of the cornea and lens focuses the incident light onto a microscopic spot on the retina (diameter ≈ 10 to 20 µm at the fovea centralis).

Optical Concentration Gain: The ratio of the dilated pupil area (d ≈ 7 mm) to the retinal focal spot area (d ≈ 10 µm) amplifies the irradiance (power density) by a factor of approximately 100,000 times (10⁵×) : Retinal Irradiance Gain = ( d pupil d spot ) 2 = ( 7.0 mm 0.02 mm ) 2 = ( 350 ) 2 ≈ 1.2 × 10 5 \text{Retinal Irradiance Gain} = \left(\frac{d_{\text{pupil}}}{d_{\text{spot}}}\right)^2 = \left(\frac{7.0\text{ mm}}{0.02\text{ mm}}\right)^2 = (350)^2 \approx 1.2 \times 10^5 Retinal Irradiance Gain = ( d spot ​ d pupil ​ ​ ) 2 = ( 0.02 mm 7.0 mm ​ ) 2 = ( 350 ) 2 ≈ 1.2 × 1 0 5

Vulnerability: Because of this extreme optical amplification, even moderate source radiances within the 400--1400 nm window can cause instantaneous retinal thermal burns or irreversible photochemical maculopathy.

2. Ultraviolet Radiation (UV) Bands and Photobiological Hazards

Ultraviolet radiation (100 to 400 nm) is subdivided into three biological bands defined by the International Commission on Illumination (CIE): +--------------------------------------------------------------------------+

  • | ULTRAVIOLET RADIATION BANDS |
  • | |
  • | • UV-C (100 - 280 nm): Germicidal (254 nm); Ozone generation (< 240 nm);|
  • | Absorbed in corneal epithelium & stratum corneum |
  • | |
  • | • UV-B (280 - 315 nm): "Sunburn / Erythemal"; Photokeratitis peak at |
  • | 270 nm; DNA pyrimidine dimers; Carcinogenesis |
  • | |
  • | • UV-A (315 - 400 nm): "Blacklight / Near-UV"; Deep skin penetration; |
  • | Lens fluorescence; Cataractogenesis; Psoralens |
  • +--------------------------------------------------------------------------+
  • 1. UV-C Band (100 nm to 280 nm: Germicidal & Vacuum UV)

Physical Properties: Solar UV-C is completely absorbed by the stratospheric ozone layer. Industrial sources include low-pressure mercury germicidal lamps (253.7 nm line), excimer lamps (222 nm KrCl), and electric arc welding.

Ozone Hazard: UV wavelengths below 240 nm (particularly the 184.9 nm mercury resonance line) photolyze ambient molecular oxygen (O2), generating toxic ozone (O3) gas. Enclosed UV systems must be evaluated for ozone buildup.

Biological Target: UV-C is strongly absorbed by proteins and nucleic acids in the superficial corneal epithelium and skin stratum corneum, causing acute, self-limiting surface inflammation.

2. UV-B Band (280 nm to 315 nm: Erythemal & Actinic Band)

Biological Potency: UV-B is the most biologically destructive optical band. It induces direct DNA damage via the formation of cyclobutane pyrimidine dimers (CPDs) and 6-4 photoproducts.

Photokeratitis ("Welder's Flash" / "Arc Eye" / Snow Blindness):

Mechanism: Acute photochemical injury and desquamation of corneal epithelial cells.

Latency Period: Characterized by a 6 to 12-hour latent delay between exposure and onset of clinical symptoms.

Symptoms: Severe ocular pain, bilateral gritty foreign-body sensation, intense photophobia, lacrimation, and conjunctival chemosis. Symptoms typically resolve within 24 to 48 hours as the corneal epithelium rapidly regenerates.

Cutaneous Effects: Acute delayed erythema (sunburn) and long-term photocarcinogenesis (basal cell carcinoma, squamous cell carcinoma, and malignant melanoma).

3. UV-A Band (315 nm to 400 nm: Near-UV & Blacklight)

Biological Penetration: Transmitted efficiently through the cornea and absorbed strongly by the crystalline lens of the human eye.

Ocular Effects: Induces fluorescence in the lens, causing immediate visual haze and glare. Chronic occupational exposure generates reactive oxygen species (ROS) that cross-link lens structural proteins, leading to premature cataractogenesis .

Photosensitization: UV-A triggers severe phototoxic and photoallergic contact dermatitis in workers exposed to exogenous photosensitizers, including coal tar pitch volatiles (PAHs) , psoralens (in celery/lime processing), anthracene, and medications (tetracyclines, fluoroquinolones, thiazides).

3. ACGIH UV Threshold Limit Values and Spectral Weighting

The biological hazard of ultraviolet radiation is highly wavelength-dependent. The ACGIH has established a Spectral Weighting Function (S(λ)) —also known as the relative spectral effectiveness —which normalizes biological actinic sensitivity to a peak value of 1.000 at λ = 270 nm .

ACGIH UV Actinic Sensitivity (S(λ)) Across Key Wavelengths

Wavelength (λ, nm) Relative Spectral Effectiveness (S(λ)) ACGIH TLV Radiant Exposure (HTLV, mJ/cm²) ACGIH TLV Radiant Exposure (HTLV, J/m²)

  • 200 nm 0.030 100.0 mJ/cm² 1,000 J/m²
  • 222 nm (Far-UVC) 0.120 25.0 mJ/cm² 250 J/m²
  • 254 nm (Hg Germicidal) 0.500 6.0 mJ/cm² 60 J/m²
  • 270 nm (PEAK HAZARD) 1.000 3.0 mJ/cm² 30 J/m²
  • 280 nm 0.880 3.4 mJ/cm² 34 J/m²
  • 300 nm 0.300 10.0 mJ/cm² 100 J/m²
  • 310 nm 0.015 200.0 mJ/cm² 2,000 J/m²
  • 315 nm (UV-A boundary) 0.001 3,000.0 mJ/cm² 30,000 J/m²
  • Mathematical Formulation of Effective Irradiance (Eeff)

For a broadband or multi-wavelength UV source (180 to 400 nm), the Effective Irradiance (Eeff) is calculated by summing or integrating the spectral irradiance (E(λ), in W/cm²·nm or µW/cm²) weighted by S(λ): E eff = ∑ λ = 180 nm 400 nm E λ ⋅ S ( λ ) ⋅ Δ λ \mathbf{E_{\text{eff}} = \sum_{\lambda = 180\text{ nm}}^{400\text{ nm}} E_\lambda \cdot S(\lambda) \cdot \Delta\lambda} E eff ​ = λ = 180 nm ∑ 400 nm ​ E λ ​ ⋅ S ( λ ) ⋅ Δ λ

Permissible Exposure Time (tmax)

The ACGIH TLV establishes that the total effective radiant exposure (Heff = Eeff × t) to the unprotected eye or skin within an 8-hour workday must not exceed 3.0 mJ/cm² = 0.003 J/cm² = 30 J/m² = 3000 µW·s/cm² .

The Maximum Permissible Exposure Time (tmax, in seconds) for an unprotected worker is: t max = 0.003 J/cm 2 E eff ( W/cm 2 ) = 3.0 mJ/cm 2 E eff ( mW/cm 2 ) = 3000 μ J/cm 2 E eff ( μ W/cm 2 ) \mathbf{t_{\text{max}} = \frac{0.003\text{ J/cm}^2}{E_{\text{eff}}\ (\text{W/cm}^2)} = \frac{3.0\text{ mJ/cm}^2}{E_{\text{eff}}\ (\text{mW/cm}^2)} = \frac{3000\, \mu\text{J/cm}^2}{E_{\text{eff}}\ (\mu\text{W/cm}^2)}} t max ​ = E eff ​ ( W/cm 2 ) 0.003 J/cm 2 ​ = E eff ​ ( mW/cm 2 ) 3.0 mJ/cm 2 ​ = E eff ​ ( μ W/cm 2 ) 3000 μ J/cm 2 ​

Unweighted UV-A Exposure Limit (315 to 400 nm)

In addition to the actinic effective limit, total unweighted UV-A radiant exposure to the eye is restricted to:

For exposure durations t ≤ 1000 seconds: Total radiant exposure HUVA ≤ 1.0 J/cm² (10,000 J/m²).

For exposure durations t > 1000 seconds (> 16.7 min): Total unweighted UV-A irradiance EUVA ≤ 1.0 mW/cm² (10 W/m²) .

4. Visible Light and the Blue Light Retinal Hazard

Visible radiation (400 to 700 nm) enters the eye and stimulates retinal photoreceptors (rods and cones). However, excessive visible irradiance presents two distinct pathophysiological hazards: +--------------------------------------------------------------------------+

  • | RETINAL PHOTOCHEMICAL VS THERMAL HAZARDS |
  • | |
  • | 1. Blue Light Hazard (400 - 500 nm): |
  • | • Photochemical damage to Retinal Pigment Epithelium (RPE) |
  • | • Peak sensitivity at 440 nm; mediated by lipofuscin & ROS |
  • | • Aphakic hazard (eyes without lens) shifts sensitivity down to 300 nm|
  • | |
  • | 2. Thermal Retinal Injury (400 - 1400 nm): |
  • | • High-radiance flash / lasers elevate retinal temperature > 10-20°C |
  • | • Instantaneous protein coagulation and scotoma (blind spot) |
  • +--------------------------------------------------------------------------+
  • The Blue Light Hazard Mechanism (400 to 500 nm)

Photochemical Maculopathy: Short-wavelength visible light (violet and blue, 400--500 nm, peaking at 440 nm ) undergoes photochemical absorption by lipofuscin chromophores in the Retinal Pigment Epithelium (RPE). This triggers the release of singlet oxygen and free radicals, inducing apoptosis of photoreceptors without requiring thermal tissue elevation.

Aphakic Eye Hazard: In aphakic individuals (whose natural crystalline lens has been surgically removed without a UV-absorbing intraocular lens implant), UV-A radiation reaches the retina unimpeded, shifting the blue-light photochemical hazard function down into the UV-A region (300--400 nm) with dramatically increased vulnerability.

5. Infrared Radiation (IR) Physics and Biological Mechanisms

Infrared radiation spans wavelengths from 700 nm (0.7 µm) to 1 mm (1000 µm) and is divided into three CIE bands:

Infrared Band Spectral Range Ocular Absorption Site Pathological Endpoint / Occupational Condition

IR-A (Near-IR) 700 nm to 1400 nm (0.7--1.4 µm) Retina (400--1400 nm) and Crystalline Lens Retinal thermal coagulation burns ; Chronic absorption by the iris/lens causes "Glassblower's Cataract" (furnaceman's cataract / exfoliation of anterior lens capsule)

IR-B (Mid-IR) 1400 nm to 3000 nm (1.4--3.0 µm) Cornea and Aqueous Humor Water absorption leads to thermal corneal burns , stromal haze, and aqueous flare

IR-C (Far-IR) 3000 nm to 1 mm (3.0 µm to 1000 µm) Superficial Corneal Epithelium & Skin Surface thermal keratopathy , corneal clouding, and cutaneous thermal burns

Pathogenesis of Glassblower's / Furnaceman's Cataract

Workers in foundries, steel mills, glassblowing shops, and aluminum smelting operations are exposed to high levels of IR-A emitted by molten materials (> 1200°C). The iris absorbs near-infrared radiation, converting it to heat and conducting it directly into the adjacent anterior lens capsule. Over years of chronic exposure, this localized thermal load causes capsular exfoliation , protein denaturing, and posterior subcapsular cataract formation.

6. Protective Eyewear and Welding Shade Number Selection

Electric arc welding processes (SMAW, GMAW, GTAW) generate extreme broadband optical emissions: intense UV-C/UV-B (inducing photokeratitis), high-radiance blue light (retinal photochemical damage), and intense IR-A/IR-B (corneal and lens thermal load). Protective welding filters must attenuate all three regions simultaneously.

ANSI Z87.1 Welding Filter Shade Number Formula

Under ANSI Z87.1 and OSHA standards, the Shade Number (SN) of a protective welding filter is mathematically defined by its luminous transmittance fraction (TL or T) in the visible spectrum: Shade Number ( S N ) = 7 3 log ⁡ 10 ( 1 T ) + 1 \mathbf{\text{Shade Number } (S_N) = \frac{7}{3} \log_{10}\left(\frac{1}{T}\right) + 1} Shade Number ( S N ​ ) = 3 7 ​ lo g 10 ​ ( T 1 ​ ) + 1

Where:

  • T = Luminous transmittance expressed as a fraction (e.g., for 0.1% transmittance, T = 0.001)
  • log10(1/T) = Optical attenuation density in the visible region

Rearranged to Solve for Luminous Transmittance (T): T = 10 − 3 7 ( S N − 1 ) = 10 − 0.4286 × ( S N − 1 ) \mathbf{T = 10^{-\frac{3}{7}(S_N - 1)} = 10^{-0.4286 \times (S_N - 1)}} T = 1 0 − 7 3 ​ ( S N ​ − 1 ) = 1 0 − 0.4286 × ( S N ​ − 1 )

OSHA / ANSI Recommended Welding Shade Selection Guide

Welding / Cutting Operation Electrode Diameter / Operating Current (Amperes) Minimum Protective Shade (SN) Suggested / Comfortable Shade (SN)

  • Shielded Metal Arc (SMAW / Stick) < 3/32 in (< 60 A) 7 9
  • Shielded Metal Arc (SMAW / Stick) 3/32--5/32 in (60--160 A) 8 10
  • Shielded Metal Arc (SMAW / Stick) 5/32--1/4 in (160--250 A) 10 12
  • Shielded Metal Arc (SMAW / Stick) > 1/4 in (> 250 A) 11 14
  • GMAW (MIG) & GTAW (TIG) < 50 A 8 10
  • GMAW (MIG) & GTAW (TIG) 50--150 A 8 12
  • GMAW (MIG) & GTAW (TIG) 150--500 A 10 14
  • Carbon Arc Gouging (Heavy) > 500 A 11 14
  • Gas Welding (Oxyfuel - Medium) 1/8 to 3/16 in plate 5 5 or 6
  • Oxygen Cutting (Heavy) ≥ 6 inches plate 5 6
  • Torch Soldering / Brazing — 2 (Soldering) / 3 (Brazing) 3 or 4
  • 7. Worked Step-by-Step Calculation Examples
  • Worked Example 14.3: Effective UV Irradiance and Permissible Exposure Time

Scenario: An industrial hygienist conducts an exposure assessment in a pharmaceutical cleanroom where an unshielded low-pressure mercury germicidal lamp (emitting monochromatic radiation at 254 nm) is used for surface sanitization. A direct-reading UV radiometer positioned at a worker's workstation measures an unweighted irradiance of E254 = 1.20 µW/cm².

The ACGIH relative spectral effectiveness for 254 nm is S(254) = 0.500.

Calculate the Effective Irradiance (Eeff) at the workstation in µW/cm² and W/cm².

Calculate the Maximum Permissible Exposure Time (tmax) for an unprotected worker during an 8-hour shift.

Determine whether a worker occupying this station for a 30-minute maintenance task would exceed the ACGIH TLV.

Solution Steps:

Calculate Effective Irradiance (Eeff): E eff = E 254 × S ( 254 ) = 1.20 μ W/cm 2 × 0.500 = 0.60 μ W/cm 2 E_{\text{eff}} = E_{254} \times S(254) = 1.20\, \mu\text{W/cm}^2 \times 0.500 = 0.60\, \mu\text{W/cm}^2 E eff ​ = E 254 ​ × S ( 254 ) = 1.20 μ W/cm 2 × 0.500 = 0.60 μ W/cm 2 Converting to W/cm 2 : E eff = 0.60 × 10 − 6 W/cm 2 = 6.0 × 10 − 7 W/cm 2 \text{Converting to W/cm}^2: \quad E_{\text{eff}} = 0.60 \times 10^{-6}\text{ W/cm}^2 = 6.0 \times 10^{-7}\text{ W/cm}^2 Converting to W/cm 2 : E eff ​ = 0.60 × 1 0 − 6 W/cm 2 = 6.0 × 1 0 − 7 W/cm 2

Calculate Maximum Permissible Exposure Time (tmax): t max = 3000 μ J/cm 2 E eff ( μ W/cm 2 ) = 3000 μ W ⋅ s/cm 2 0.60 μ W/cm 2 = 5 , 000 seconds t_{\text{max}} = \frac{3000\, \mu\text{J/cm}^2}{E_{\text{eff}}\ (\mu\text{W/cm}^2)} = \frac{3000\, \mu\text{W}\cdot\text{s/cm}^2}{0.60\, \mu\text{W/cm}^2} = 5,000\text{ seconds} t max ​ = E eff ​ ( μ W/cm 2 ) 3000 μ J/cm 2 ​ = 0.60 μ W/cm 2 3000 μ W ⋅ s/cm 2 ​ = 5 , 000 seconds Converting to minutes: t max = 5000 s 60 s/min = 83.33 minutes ≈ 1 hour 23 minutes \text{Converting to minutes: } \quad t_{\text{max}} = \frac{5000\text{ s}}{60\text{ s/min}} = 83.33\text{ minutes} \approx 1\text{ hour } 23\text{ minutes} Converting to minutes: t max ​ = 60 s/min 5000 s ​ = 83.33 minutes ≈ 1 hour 23 minutes

Assess Compliance for 30-Minute Task:

The task duration (30 minutes = 1800 seconds) is less than tmax = 83.33 minutes.

Delivered Radiant Exposure: H eff = E eff × t = ( 0.60 μ W/cm 2 ) × 1800 s = 1 , 080 μ J/cm 2 = 1.08 mJ/cm 2 H_{\text{eff}} = E_{\text{eff}} \times t = (0.60\, \mu\text{W/cm}^2) \times 1800\text{ s} = 1,080\, \mu\text{J/cm}^2 = 1.08\text{ mJ/cm}^2 H eff ​ = E eff ​ × t = ( 0.60 μ W/cm 2 ) × 1800 s = 1 , 080 μ J/cm 2 = 1.08 mJ/cm 2

Since 1.08 mJ/cm² < 3.0 mJ/cm², the 30-minute task complies with the ACGIH TLV. However, if the worker remains for > 83.3 minutes without UV-blocking face shields, the TLV will be exceeded.

Worked Example 14.4: Welding Filter Shade Number Calculation

Scenario: A specialized optical filter plate designed for robotic gas metal arc welding (GMAW) inspection is tested using a spectrophotometer. The luminous transmittance of the filter in the visible spectrum is measured as T = 0.00316% (T = 3.16 × 10⁻⁵ as a fraction).

Calculate the exact ANSI Z87.1 welding shade number (SN) for this filter.

Determine the standard rounded commercial shade designation.

Solution Steps:

Apply the ANSI Shade Number Formula: S N = 7 3 log ⁡ 10 ( 1 T ) + 1 S_N = \frac{7}{3} \log_{10}\left(\frac{1}{T}\right) + 1 S N ​ = 3 7 ​ lo g 10 ​ ( T 1 ​ ) + 1 1 T = 1 3.1623 × 10 − 5 = 31 , 622.78 \frac{1}{T} = \frac{1}{3.1623 \times 10^{-5}} = 31,622.78 T 1 ​ = 3.1623 × 1 0 − 5 1 ​ = 31 , 622.78 log ⁡ 10 ( 31 , 622.78 ) = 4.50 \log_{10}(31,622.78) = 4.50 lo g 10 ​ ( 31 , 622.78 ) = 4.50 S N = ( 7 3 × 4.50 ) + 1 = ( 2.3333 × 4.50 ) + 1 = 10.50 + 1 = 11.50 S_N = \left(\frac{7}{3} \times 4.50\right) + 1 = (2.3333 \times 4.50) + 1 = 10.50 + 1 = 11.50 S N ​ = ( 3 7 ​ × 4.50 ) + 1 = ( 2.3333 × 4.50 ) + 1 = 10.50 + 1 = 11.50

Commercial Designation:

The exact mathematical shade number is 11.5 .

Under commercial manufacturing tolerances (ANSI Z87.1), this filter is rated as a Shade 11 or Shade 12 protective plate suitable for high-current MIG welding (150--250 A).