Study guide
11.4 Gaseous Emission Control and Air Cleaner Selection
CIH Certified Industrial Hygienist Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: The CIH Exam and How to Use This Guide
1.1 CIH Exam Format, Scoring, and Test-Day Logistics 1.2 Eligibility, Application Windows, Fees, and Certification Maintenance 1.3 The BGC Blueprint, Subject Areas, and a Calculation-First Study Plan
2 Chapter 2: Basic Science & Calculations
2.1 Gas Laws and Vapor Calculations 2.2 Unit Conversions: ppm, mg/m³, and Standard Temperature/Pressure 2.3 Fluid Mechanics and Airflow Fundamentals
3 Chapter 3: Air Sampling & Instrumentation
3.1 Active and Passive Air Sampling Strategies 3.2 Particulate and Aerosol Sampling 3.3 Direct-Reading Instruments and Calibration
4 Chapter 4: Analytical Chemistry & Lab Methods
4.1 Gas Chromatography and Mass Spectrometry 4.2 High-Performance Liquid Chromatography and Ion Chromatography 4.3 Spectroscopy and Elemental Analysis 4.4 Gravimetric, Microscopy, and Wet Chemical Methods 4.5 Laboratory Quality Assurance, Chain of Custody, and Desorption Efficiency
5 Chapter 5: Biostatistics & Epidemiology
5.1 Lognormal Distributions and Exposure Data Statistics 5.2 Upper Confidence Limits (UCL95) and Compliance Decision Rules 5.3 Epidemiological Study Designs and Measures of Association 5.4 Sampling Strategy: Sample Size, Power, and Worker Selection
6 Chapter 6: Toxicology & Biological Monitoring
6.1 Dose-Response Relationships and Points of Departure 6.2 Toxicokinetics: Absorption, Distribution, Metabolism, and Elimination 6.3 Aerosol Deposition, Clearance, and Respiratory Tract Dosimetry 6.4 Hepatic, Renal, Neurologic, and Hematologic Target Organ Toxicity 6.5 Pulmonary Toxicology, Carcinogenicity, and Reproductive Hazards 6.6 OEL Frameworks, Classifications, and Excursion Limits 6.7 Chemical Mixtures and Extended Work-Shift OEL Adjustments 6.8 Biological Exposure Indices (BEIs) and Biomonitoring
7 Chapter 7: Biohazards & Indoor Environmental Quality
7.1 Mold, Fungi, and Microbial Contaminants 7.2 Infectious Agents, Bloodborne Pathogens, and Biosafety Levels 7.3 Indoor Environmental Quality (IEQ) Investigations 7.4 Sanitation, Potable Water, and Personal Hygiene Programs
8 Chapter 8: Community Exposure & Environmental Health
8.1 Clean Air Act Framework, NAAQS, and New Source Review 8.2 Hazardous Air Pollutants, CEMS, and EPA Reference Methods 8.3 Atmospheric Stability, Lapse Rates, and Plume Morphology 8.4 Gaussian Plume Modeling, Plume Rise, and Environmental Fate 8.5 HAZWOPER Scope, Mandates, and Training Tiers 8.6 Protection Levels, Site Zoning, Incident Command, and Decontamination 8.7 Water Pollution, Hazardous Waste, and Community Right-to-Know
9 Chapter 9: Health Risk Analysis & Hazard Communication
9.1 GHS Hazard Classification: Health and Physical Hazard Criteria 9.2 GHS Labels, Safety Data Sheets, and Trade Secret Rules 9.3 The AIHA Exposure Assessment Strategy and Similar Exposure Groups 9.4 Qualitative Exposure Profiling and the AIHA Risk Matrix 9.5 Quantitative Health Risk Characterization: HQ, HI, and ELCR 9.6 NIOSH Occupational Exposure Banding 9.7 Risk Communication and Reporting to Affected Parties
10 Chapter 10: Industrial Ventilation Principles & LEV Design
10.1 Elimination, Substitution, Isolation, Containment, and Process Change 10.2 LEV Hood Taxonomy and Capture Velocity Selection 10.3 Hood Airflow Equations, Entry Losses, and Hood Static Pressure 10.4 Particulate Transport Aerodynamics and Duct Sizing 10.5 Duct Friction, Fitting Losses, and System Balancing 10.6 Fan Categories and Pressure Dynamics Across the Fan 10.7 System Curves, the Fan Laws, and Density Corrections
11 Chapter 11: General Ventilation, Air Cleaning & Diagnostics
11.1 Dilution Ventilation Principles and Steady-State Modeling 11.2 Transient Purging and Air Distribution Geometry 11.3 Particulate Air Cleaning: Cyclones, Baghouses, Scrubbers, and ESPs 11.4 Gaseous Emission Control and Air Cleaner Selection 11.5 Ventilation System Troubleshooting and Testing
12 Chapter 12: Noise Measurement & Hearing Conservation
12.1 Acoustic Physics and Decibel Mathematics 12.2 Sound Propagation, Octave Bands, and Frequency Weighting 12.3 Noise Dose Metrics and OSHA versus ACGIH Criteria 12.4 Exchange Rates, Extended Shifts, and Dosimetry Field Protocols 12.5 Engineering Noise Controls and Hearing Protector Attenuation 12.6 Hearing Conservation Programs and Standard Threshold Shifts 12.7 Hand-Arm and Whole-Body Vibration
13 Chapter 13: Thermal Stress Assessment & Control
13.1 Wet Bulb Globe Temperature (WBGT) and Heat Stress Indices 13.2 Heat-Related Disorders, Acclimatization, and Work/Rest Regimens 13.3 Cold Stress Evaluation and Wind Chill
14 Chapter 14: Ionizing Radiation Protection
14.1 Ionizing Radiation Physics and Radioactive Decay Kinetics 14.2 Radiation Units, Radiobiology, and Health Effects 14.3 ALARA, Stay-Time, and the Inverse Square Law 14.4 Shielding Physics, Material Selection, and Gamma Constants 14.5 Radiation Detection Instruments and Spectrometry 14.6 Personnel Dosimetry, Dose Limits, and Contamination Surveys
15 Chapter 15: Non-Ionizing Radiation & Laser Safety
15.1 The Non-Ionizing Spectrum and Static/ELF Field Exposures 15.2 Radiofrequency and Microwave Exposure: SAR, Standards, and Surveys 15.3 Ultraviolet, Visible, and Infrared Radiation Hazards 15.4 Laser Safety Classifications and Optical Density Calculations 15.5 Illumination, Lighting Design, and Visual Performance
16 Chapter 16: Non-Engineering Controls & Personal Protective Equipment
16.1 Respiratory Protection Programs and Assigned Protection Factors 16.2 Maximum Use Concentration, Oxygen Deficiency, and Breathing Air 16.3 Particulate Filters, Sorbent Cartridges, and Change Schedules 16.4 Respirator Fit Testing Protocols 16.5 Chemical Protective Clothing and Dermal Exposure Control
17 Chapter 17: Ergonomics & Workstation Design
17.1 Soft-Tissue Biomechanics and WMSD Pathophysiology 17.2 Ergonomic Risk Factors and Their Interaction Effects 17.3 The Revised NIOSH Lifting Equation 17.4 RULA, REBA, the Strain Index, and the ACGIH HAL TLV 17.5 Anthropometry and Workstation Geometry 17.6 VDT Workstations, Hand Tool Design, and Administrative Ergonomics
18 Chapter 18: Work Environments & Industrial Processes
18.1 Welding Fume Emissions, Metal Fume Fever, and Cr(VI)/Manganese Toxicology 18.2 Foundry Operations and Hot Work Fire Prevention 18.3 Vapor Degreasing, Pickling, Electroplating, and Cyanide Baths 18.4 Spray Coatings, Isocyanates, and Semiconductor Manufacturing 18.5 Confined Spaces and High-Hazard Industrial Operations 18.6 Asbestos, Lead, and Silica: Regulated Substance Programs 18.7 Abrasive Blasting and Surface Preparation
19 Chapter 19: IH Program Management & Professional Ethics
19.1 The BGC Code of Ethics: Canons and Enforcement 19.2 Professional Liability, Standard of Care, and Expert Testimony 19.3 Occupational Health & Safety Management Systems (ISO 45001, ANSI Z10) 19.4 Exposure Records Access and Medical Surveillance 19.5 OSHA Injury and Illness Recordkeeping and Enforcement
11.4 Gaseous Emission Control and Air Cleaner Selection
Key Takeaways Explain This Topic AI
Gaseous control uses three mechanisms: absorption into a liquid (packed towers), adsorption onto a solid (activated carbon), and destruction by thermal, catalytic, or biological oxidation.
Activated carbon adsorption works well for non-polar organics above about 50 molecular weight but is defeated by high humidity, high temperature, and very volatile or highly polar compounds.
Thermal oxidisers destroy organics at high temperature; catalytic oxidisers achieve the same destruction at several hundred degrees lower, saving fuel but requiring a catalyst that is poisoned by silicones, halogens, and heavy metals.
Selection is driven by contaminant phase, particle size distribution, concentration, temperature, moisture, corrosivity, required efficiency, and disposal route for the collected material.
Last updated: August 2026
Gaseous Emission Control and Air Cleaner Selection
Particulate collectors work on inertia, interception, and electrostatic attraction. None of those mechanisms touches a gas or vapour molecule, which is why gaseous control uses an entirely different family of devices — absorption, adsorption, and oxidation.
1. Gaseous Emission Control: Absorption, Adsorption & Oxidation +-------------------------------------------------------------------------+
- | GASEOUS EMISSION CONTROL TECHNOLOGIES |
- +-------------------------------------------------------------------------+
- | |
- | A. ABSORPTION (Gas-to-Liquid Mass Transfer): |
- | - Soluble gases (HCl, NH3, SO2, Cl2) dissolve into liquid solvent. |
- | - Packed towers with random/structured packing provide high surface.|
- | |
- | B. ADSORPTION (Gas-to-Solid Surface Condensation): |
- | - VOCs captured in micropores of activated carbon (1,000 m²/g). |
- | - Characterized by S-shaped breakthrough curves and bed life. |
- | |
- | C. THERMAL / CATALYTIC OXIDATION (Combustion Destruction): |
- | - VOC + O2 + Heat ===> CO2 + H2O |
- | - Direct Thermal: 1,400 - 1,800°F (High fuel, RTO has 95% recovery) |
- | - Catalytic (Pt/Pd): 600 - 800°F (Lower energy; poison sensitive) |
- +-------------------------------------------------------------------------+
- 1. Packed Bed Absorption Towers (Scrubbers)
Absorption involves transferring a soluble gaseous pollutant from a gas stream into a liquid solvent (physical absorption) followed by chemical neutralization (chemical absorption):
Governing Law: Governed by Henry's Law (pi = Hi · xi, where pi is partial pressure and Hi is Henry's constant).
Column Hydrodynamics: Counter-current packed beds operate between the loading point (where liquid holdup begins to impede gas flow) and the flooding point (where upward gas velocity completely backs up liquid, causing column failure). Towers are designed to operate at 50% to 70% of flooding velocity .
Common Reagents: Sodium hydroxide (NaOH) for acid gases (HCl, SO2, HF); Sulfuric acid (H2SO4) for basic gases (ammonia, amines); Sodium hypochlorite (NaOCl) for odors and sulfur compounds.
2. Adsorption Systems (Activated Carbon)
Adsorption is a surface phenomenon where gas molecules (adsorbate) are attracted and held to the porous solid surface (adsorbent) by physical van der Waals forces ( physisorption ) or covalent chemical bonding ( chemisorption ).
Adsorbent Characteristics: Granular Activated Carbon ( GAC ) possesses an extraordinary specific surface area of 800 to 1,500 m²/g packed into micro- and mesopores (< 2 to 50 nm).
Breakthrough Curve: As gas passes through the carbon bed, an adsorption zone (mass transfer zone, MTZ) moves progressively downstream. When the leading edge of the MTZ reaches the bed exit, the exit concentration abruptly spikes—termed the breakthrough point (Cb, typically defined at 5% of inlet concentration C0). +-------------------------------------------------------------------------+
- | CARBON BED BREAKTHROUGH DYNAMICS |
- +-------------------------------------------------------------------------+
- | |
- | Exit Concentration (C / C0) |
- | 1.0 | ...---* Saturated
- | | ..-'' |
- | | .-' |
- | | .-' (Mass Transfer Zone) |
- | 0.05|-------------------------------------* Breakthrough Point (tb) |
- | 0.0 +-------------------------------------+-------------------> Time |
- | 0 tb |
- +-------------------------------------------------------------------------+
Wheeler-Jonas Bed Depth Service Life (BDSL) Model: The breakthrough time (tb) is calculated from carbon bed mass (W), bulk density (ρb), airflow (Q), adsorptive capacity (We), and adsorption rate constant (kv): t b = W e ⋅ W C 0 ⋅ Q − W e ⋅ ρ b k v ⋅ C 0 ln ( C 0 − C b C b ) t_b = \frac{W_e \cdot W}{C_0 \cdot Q} - \frac{W_e \cdot \rho_b}{k_v \cdot C_0} \ln\left(\frac{C_0 - C_b}{C_b}\right) t b = C 0 ⋅ Q W e ⋅ W − k v ⋅ C 0 W e ⋅ ρ b ln ( C b C 0 − C b )
Regeneration: Saturated carbon beds are desorbed using superheated steam or hot inert gas (extN2 at 250--300°F), recovering solvent and restoring bed capacity.
3. Thermal and Catalytic Oxidizers
Thermal destruction of VOCs converts hydrocarbons into carbon dioxide and water vapor via high-temperature oxidation (CxHy + (x + y/4)O2 → x CO2 + (y/2) H2O):
The 3 T's of Combustion: Complete destruction (> 99%) requires optimizing Time (residence time 0.5 to 2.0 seconds), Temperature , and Turbulence (Reynolds number > 10,000).
Direct Flame Thermal Oxidizers (DFTO): Operate at 1,400 to 1,800°F (760 to 980°C) . High auxiliary fuel consumption unless equipped with recuperative heat exchangers.
Regenerative Thermal Oxidizers (RTO): Utilize multiple ceramic honeycomb/saddle beds to preheat incoming process air with outgoing combustion exhaust, achieving 95%+ thermal energy recovery and allowing self-sustaining (autothermal) operation at VOC concentrations > 1.5--2.0 g/m³.
Catalytic Oxidizers: Pass preheated VOC gas across a noble metal catalyst bed (platinum, palladium, rhodium on ceramic honeycomb). The catalyst lowers the required activation energy, allowing complete oxidation at 600 to 800°F (315 to 425°C) —saving massive auxiliary fuel.
Critical CIH Exam Concept — Catalyst Poisoning & Deactivation: Catalytic oxidizers cannot be used if the exhaust gas contains catalyst poisons or masking agents:
Irreversible Chemical Poisons: Heavy metals (lead, arsenic, mercury), phosphorus, silicones (form glass-like SiO2 crusts over active sites).
Catalyst Inhibitors / Deactivators: Sulfur compounds (SO2, H2S), halogens (chlorinated solvents like TCE or methylene chloride form acidic HCl and corrode/poison noble metals).
2. Comprehensive Air Cleaner Comparison Matrix
Air Cleaning Technology Target Pollutants Operating Temp. Range Typical Pressure Drop (Δ P) Capital vs Operating Cost Key Failure Mode / Limitation
Settling Chamber Large dusts (> 50 µm) Up to 1,000°F 0.1--0.5 in. w.g. Low Cap / Low Op Huge physical footprint; zero submicron collection.
Standard Cyclone Coarse dusts (> 10 µm) Up to 1,000°F 2.0--4.0 in. w.g. Low Cap / Low Op Low efficiency for PM2.5; wall erosion from abrasive dust.
Pulse-Jet Baghouse Fine dusts, metal fumes (0.1--100 µm) Up to 500°F (with Nomex/PTFE) 4.0--8.0 in. w.g. Moderate Cap / Mod Op Bag blinding from moisture/oil (dew point condensation); fire risk.
Venturi Scrubber Submicron fumes, sticky/combustible dusts Gas cooled by adiabatic quench 20.0--60.0 in. w.g. Mod Cap / Very High Op High fan energy; wastewater treatment and acidic corrosion.
Dry ESP Fly ash, cement, metallurgical fumes 250 to 750°F 0.5--1.5 in. w.g. High Cap / Low Op Sensitive to dust resistivity; back corona; explosion hazard with VOCs.
Packed Absorption Column Soluble acid/base gases (HCl, NH3) Up to 150°F (polypro/FRP) 2.0--6.0 in. w.g. Moderate Cap / Mod Op Packing fouling/scaling; chemical consumption; wastewater disposal.
Activated Carbon Adsorber Non-polar VOCs, solvent vapors < 130°F (< 55°C), RH < 60% 3.0--8.0 in. w.g. Moderate Cap / Mod Op Bed breakthrough; desorptive bed fires (ketones); moisture competition.
Regenerative Thermal Oxidizer (RTO) General VOCs, odors 1,400 to 1,600°F combustion chamber 10.0--18.0 in. w.g. High Cap / Mod Op Ceramic media plugging by sticky particulate; high switching valve wear.
Catalytic Oxidizer Low-concentration VOCs 600 to 800°F catalyst bed 4.0--8.0 in. w.g. Mod-High Cap / Mod Op Catalyst poisoning by sulfur, lead, chlorine, or silicones.
- 3. Worked Step-by-Step Calculation Examples
- Worked Example 10.2.1: Sizing a Pulse-Jet Baghouse Filter Area
Problem: An industrial woodworking facility generates fine sawdust and sander dust collected by an LEV system exhausting Q = 18,000 cfm. The engineering design standard specifies a pulse-jet baghouse with needle-punched polyester felt media operating at an Air-to-Cloth ratio (A/C) of 6.0 ft/min. Cylindrical filter bags with a diameter D = 6.0 inches (0.50 ft) and length L = 10.0 feet are specified.
Calculate the total active cloth filtration area (Acloth) required.
Calculate the surface area of an individual filter bag (Abag).
Determine the minimum number of filter bags required in the baghouse.
Solution Steps:
Calculate total required cloth area (Acloth = Q / [A/C]): A cloth = 18 , 000 cfm 6.0 ft/min = 3000 ft 2 A_{\text{cloth}} = \frac{18,000\text{ cfm}}{6.0\text{ ft/min}} = 3000\text{ ft}^2 A cloth = 6.0 ft/min 18 , 000 cfm = 3000 ft 2
Calculate the surface area of one cylindrical bag (Abag = π · D · L): D = 6.0 in = 0.50 ft D = 6.0\text{ in} = 0.50\text{ ft} D = 6.0 in = 0.50 ft A bag = π × 0.50 ft × 10.0 ft = 3.14159 × 5.0 = 15.708 ft 2 A_{\text{bag}} = \pi \times 0.50\text{ ft} \times 10.0\text{ ft} = 3.14159 \times 5.0 = 15.708\text{ ft}^2 A bag = π × 0.50 ft × 10.0 ft = 3.14159 × 5.0 = 15.708 ft 2
Determine the number of bags required (Nbags = Acloth / Abag): N bags = 3000 ft 2 15.708 ft 2 / bag = 190.98 ⟹ 191 bags N_{\text{bags}} = \frac{3000\text{ ft}^2}{15.708\text{ ft}^2/\text{bag}} = 190.98 \implies 191\text{ bags} N bags = 15.708 ft 2 / bag 3000 ft 2 = 190.98 ⟹ 191 bags
(In standard practice, this is rounded up to a symmetrical structural grid, e.g., a 14 × 14 = 196 bag housing) .
Result: The baghouse requires a total active cloth area of 3,000 ft² and a minimum of 191 filter bags .
Worked Example 10.2.2: Electrostatic Precipitator Efficiency via Deutsch-Anderson Equation
Problem: An industrial coal-fired utility boiler utilizes an electrostatic precipitator to clean Q = 120,000 cfm (2000 ft³/sec) of flue gas. The ESP has a total collection plate surface area A = 40,000 ft². Field testing confirms an average particle migration velocity w = 0.35 ft/sec (21.0 ft/min).
Calculate the fractional collection efficiency (η) and percentage efficiency of the ESP.
If the plate area is increased by 25% to Anew = 50,000 ft², calculate the new collection efficiency.
Solution Steps:
Calculate the exponent term ((w · A)/Q): Using consistent units in seconds: w = 0.35 ft/s , A = 40 , 000 ft 2 , Q = 2000 ft 3 / s \text{Using consistent units in seconds: } w = 0.35\text{ ft/s}, \quad A = 40,000\text{ ft}^2, \quad Q = 2000\text{ ft}^3/\text{s} Using consistent units in seconds: w = 0.35 ft/s , A = 40 , 000 ft 2 , Q = 2000 ft 3 / s w ⋅ A Q = 0.35 × 40 , 000 2000 = 14 , 000 2000 = 7.0 \frac{w \cdot A}{Q} = \frac{0.35 \times 40,000}{2000} = \frac{14,000}{2000} = 7.0 Q w ⋅ A = 2000 0.35 × 40 , 000 = 2000 14 , 000 = 7.0
(Using minutes: (21.0 ft/min × 40,000 ft²)/(120,000 cfm) = 840,000/120,000 = 7.0)
Calculate collection efficiency using Deutsch-Anderson equation: η = 1 − e − 7.0 = 1 − 0.0009118 = 0.999088 ⟹ 99.91 % \eta = 1 - e^{-7.0} = 1 - 0.0009118 = 0.999088 \implies \mathbf{99.91\%} η = 1 − e − 7.0 = 1 − 0.0009118 = 0.999088 ⟹ 99.91%
Calculate new efficiency with A = 50,000 ft²: w ⋅ A new Q = 0.35 × 50 , 000 2000 = 8.75 \frac{w \cdot A_{\text{new}}}{Q} = \frac{0.35 \times 50,000}{2000} = 8.75 Q w ⋅ A new = 2000 0.35 × 50 , 000 = 8.75 η new = 1 − e − 8.75 = 1 − 0.0001584 = 0.999842 ⟹ 99.98 % \eta_{\text{new}} = 1 - e^{-8.75} = 1 - 0.0001584 = 0.999842 \implies \mathbf{99.98\%} η new = 1 − e − 8.75 = 1 − 0.0001584 = 0.999842 ⟹ 99.98%
Result: The initial collection efficiency is 99.91% ; expanding the plate area by 25% increases efficiency to 99.98% (reducing particulate emissions by over 82%).
Worked Example 10.2.3: Activated Carbon Adsorber Bed Service Life
Problem: An exhaust stream conveying Q = 2,000 cfm containing C0 = 150 ppm of toluene vapor enters an activated carbon adsorption vessel containing W = 1,200 lbs of virgin GAC.
- Toluene molecular weight = 92.14 g/mol
- Carbon equilibrium capacity (We) = 0.15 lb toluene / lb carbon (15% by weight)
Calculate the operating bed service life in hours before total saturation, assuming ideal sharp breakthrough.
Solution Steps:
Calculate total toluene adsorptive capacity of the carbon bed: Total Capacity = W × W e = 1 , 200 lbs carbon × 0.15 lb toluene/lb carbon = 180 lbs of toluene \text{Total Capacity} = W \times W_e = 1,200\text{ lbs carbon} \times 0.15\text{ lb toluene/lb carbon} = 180\text{ lbs of toluene} Total Capacity = W × W e = 1 , 200 lbs carbon × 0.15 lb toluene/lb carbon = 180 lbs of toluene
Calculate the mass emission rate of toluene entering the bed (ER(lb/hr)): Q = 387 × 10 6 ⋅ E R lb/hr 60 ⋅ MW ⋅ C ppm ⟹ E R lb/hr = Q ⋅ 60 ⋅ MW ⋅ C ppm 387 × 10 6 Q = \frac{387 \times 10^6 \cdot ER_{\text{lb/hr}}}{60 \cdot \text{MW} \cdot C_{\text{ppm}}} \implies ER_{\text{lb/hr}} = \frac{Q \cdot 60 \cdot \text{MW} \cdot C_{\text{ppm}}}{387 \times 10^6} Q = 60 ⋅ MW ⋅ C ppm 387 × 1 0 6 ⋅ E R lb/hr ⟹ E R lb/hr = 387 × 1 0 6 Q ⋅ 60 ⋅ MW ⋅ C ppm E R lb/hr = 2000 × 60 × 92.14 × 150 387 , 000 , 000 = 1 , 658 , 520 , 000 387 , 000 , 000 = 4.2856 lbs of toluene/hr ER_{\text{lb/hr}} = \frac{2000 \times 60 \times 92.14 \times 150}{387,000,000} = \frac{1,658,520,000}{387,000,000} = 4.2856\text{ lbs of toluene/hr} E R lb/hr = 387 , 000 , 000 2000 × 60 × 92.14 × 150 = 387 , 000 , 000 1 , 658 , 520 , 000 = 4.2856 lbs of toluene/hr
Calculate bed service life (tservice): t service = Total Capacity E R lb/hr = 180 lbs 4.2856 lbs/hr = 42.0 hours t_{\text{service}} = \frac{\text{Total Capacity}}{ER_{\text{lb/hr}}} = \frac{180\text{ lbs}}{4.2856\text{ lbs/hr}} = 42.0\text{ hours} t service = E R lb/hr Total Capacity = 4.2856 lbs/hr 180 lbs = 42.0 hours
Result: The carbon bed will reach saturation after 42.0 hours of continuous operation.