Study guide
11.2 Transient Purging and Air Distribution Geometry
CIH Certified Industrial Hygienist Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: The CIH Exam and How to Use This Guide
1.1 CIH Exam Format, Scoring, and Test-Day Logistics 1.2 Eligibility, Application Windows, Fees, and Certification Maintenance 1.3 The BGC Blueprint, Subject Areas, and a Calculation-First Study Plan
2 Chapter 2: Basic Science & Calculations
2.1 Gas Laws and Vapor Calculations 2.2 Unit Conversions: ppm, mg/m³, and Standard Temperature/Pressure 2.3 Fluid Mechanics and Airflow Fundamentals
3 Chapter 3: Air Sampling & Instrumentation
3.1 Active and Passive Air Sampling Strategies 3.2 Particulate and Aerosol Sampling 3.3 Direct-Reading Instruments and Calibration
4 Chapter 4: Analytical Chemistry & Lab Methods
4.1 Gas Chromatography and Mass Spectrometry 4.2 High-Performance Liquid Chromatography and Ion Chromatography 4.3 Spectroscopy and Elemental Analysis 4.4 Gravimetric, Microscopy, and Wet Chemical Methods 4.5 Laboratory Quality Assurance, Chain of Custody, and Desorption Efficiency
5 Chapter 5: Biostatistics & Epidemiology
5.1 Lognormal Distributions and Exposure Data Statistics 5.2 Upper Confidence Limits (UCL95) and Compliance Decision Rules 5.3 Epidemiological Study Designs and Measures of Association 5.4 Sampling Strategy: Sample Size, Power, and Worker Selection
6 Chapter 6: Toxicology & Biological Monitoring
6.1 Dose-Response Relationships and Points of Departure 6.2 Toxicokinetics: Absorption, Distribution, Metabolism, and Elimination 6.3 Aerosol Deposition, Clearance, and Respiratory Tract Dosimetry 6.4 Hepatic, Renal, Neurologic, and Hematologic Target Organ Toxicity 6.5 Pulmonary Toxicology, Carcinogenicity, and Reproductive Hazards 6.6 OEL Frameworks, Classifications, and Excursion Limits 6.7 Chemical Mixtures and Extended Work-Shift OEL Adjustments 6.8 Biological Exposure Indices (BEIs) and Biomonitoring
7 Chapter 7: Biohazards & Indoor Environmental Quality
7.1 Mold, Fungi, and Microbial Contaminants 7.2 Infectious Agents, Bloodborne Pathogens, and Biosafety Levels 7.3 Indoor Environmental Quality (IEQ) Investigations 7.4 Sanitation, Potable Water, and Personal Hygiene Programs
8 Chapter 8: Community Exposure & Environmental Health
8.1 Clean Air Act Framework, NAAQS, and New Source Review 8.2 Hazardous Air Pollutants, CEMS, and EPA Reference Methods 8.3 Atmospheric Stability, Lapse Rates, and Plume Morphology 8.4 Gaussian Plume Modeling, Plume Rise, and Environmental Fate 8.5 HAZWOPER Scope, Mandates, and Training Tiers 8.6 Protection Levels, Site Zoning, Incident Command, and Decontamination 8.7 Water Pollution, Hazardous Waste, and Community Right-to-Know
9 Chapter 9: Health Risk Analysis & Hazard Communication
9.1 GHS Hazard Classification: Health and Physical Hazard Criteria 9.2 GHS Labels, Safety Data Sheets, and Trade Secret Rules 9.3 The AIHA Exposure Assessment Strategy and Similar Exposure Groups 9.4 Qualitative Exposure Profiling and the AIHA Risk Matrix 9.5 Quantitative Health Risk Characterization: HQ, HI, and ELCR 9.6 NIOSH Occupational Exposure Banding 9.7 Risk Communication and Reporting to Affected Parties
10 Chapter 10: Industrial Ventilation Principles & LEV Design
10.1 Elimination, Substitution, Isolation, Containment, and Process Change 10.2 LEV Hood Taxonomy and Capture Velocity Selection 10.3 Hood Airflow Equations, Entry Losses, and Hood Static Pressure 10.4 Particulate Transport Aerodynamics and Duct Sizing 10.5 Duct Friction, Fitting Losses, and System Balancing 10.6 Fan Categories and Pressure Dynamics Across the Fan 10.7 System Curves, the Fan Laws, and Density Corrections
11 Chapter 11: General Ventilation, Air Cleaning & Diagnostics
11.1 Dilution Ventilation Principles and Steady-State Modeling 11.2 Transient Purging and Air Distribution Geometry 11.3 Particulate Air Cleaning: Cyclones, Baghouses, Scrubbers, and ESPs 11.4 Gaseous Emission Control and Air Cleaner Selection 11.5 Ventilation System Troubleshooting and Testing
12 Chapter 12: Noise Measurement & Hearing Conservation
12.1 Acoustic Physics and Decibel Mathematics 12.2 Sound Propagation, Octave Bands, and Frequency Weighting 12.3 Noise Dose Metrics and OSHA versus ACGIH Criteria 12.4 Exchange Rates, Extended Shifts, and Dosimetry Field Protocols 12.5 Engineering Noise Controls and Hearing Protector Attenuation 12.6 Hearing Conservation Programs and Standard Threshold Shifts 12.7 Hand-Arm and Whole-Body Vibration
13 Chapter 13: Thermal Stress Assessment & Control
13.1 Wet Bulb Globe Temperature (WBGT) and Heat Stress Indices 13.2 Heat-Related Disorders, Acclimatization, and Work/Rest Regimens 13.3 Cold Stress Evaluation and Wind Chill
14 Chapter 14: Ionizing Radiation Protection
14.1 Ionizing Radiation Physics and Radioactive Decay Kinetics 14.2 Radiation Units, Radiobiology, and Health Effects 14.3 ALARA, Stay-Time, and the Inverse Square Law 14.4 Shielding Physics, Material Selection, and Gamma Constants 14.5 Radiation Detection Instruments and Spectrometry 14.6 Personnel Dosimetry, Dose Limits, and Contamination Surveys
15 Chapter 15: Non-Ionizing Radiation & Laser Safety
15.1 The Non-Ionizing Spectrum and Static/ELF Field Exposures 15.2 Radiofrequency and Microwave Exposure: SAR, Standards, and Surveys 15.3 Ultraviolet, Visible, and Infrared Radiation Hazards 15.4 Laser Safety Classifications and Optical Density Calculations 15.5 Illumination, Lighting Design, and Visual Performance
16 Chapter 16: Non-Engineering Controls & Personal Protective Equipment
16.1 Respiratory Protection Programs and Assigned Protection Factors 16.2 Maximum Use Concentration, Oxygen Deficiency, and Breathing Air 16.3 Particulate Filters, Sorbent Cartridges, and Change Schedules 16.4 Respirator Fit Testing Protocols 16.5 Chemical Protective Clothing and Dermal Exposure Control
17 Chapter 17: Ergonomics & Workstation Design
17.1 Soft-Tissue Biomechanics and WMSD Pathophysiology 17.2 Ergonomic Risk Factors and Their Interaction Effects 17.3 The Revised NIOSH Lifting Equation 17.4 RULA, REBA, the Strain Index, and the ACGIH HAL TLV 17.5 Anthropometry and Workstation Geometry 17.6 VDT Workstations, Hand Tool Design, and Administrative Ergonomics
18 Chapter 18: Work Environments & Industrial Processes
18.1 Welding Fume Emissions, Metal Fume Fever, and Cr(VI)/Manganese Toxicology 18.2 Foundry Operations and Hot Work Fire Prevention 18.3 Vapor Degreasing, Pickling, Electroplating, and Cyanide Baths 18.4 Spray Coatings, Isocyanates, and Semiconductor Manufacturing 18.5 Confined Spaces and High-Hazard Industrial Operations 18.6 Asbestos, Lead, and Silica: Regulated Substance Programs 18.7 Abrasive Blasting and Surface Preparation
19 Chapter 19: IH Program Management & Professional Ethics
19.1 The BGC Code of Ethics: Canons and Enforcement 19.2 Professional Liability, Standard of Care, and Expert Testimony 19.3 Occupational Health & Safety Management Systems (ISO 45001, ANSI Z10) 19.4 Exposure Records Access and Medical Surveillance 19.5 OSHA Injury and Illness Recordkeeping and Enforcement
11.2 Transient Purging and Air Distribution Geometry
Key Takeaways Explain This Topic AI
Concentration build-up toward steady state and decay after a release both follow exponential first-order behaviour governed by the air change rate Q/V.
The purge equation t = −(V/Q)·ln(C2/C1) gives the time to fall from one concentration to another with no ongoing generation; the number of air changes required depends only on the concentration ratio, not on room size.
One air change removes about 63% of the contaminant, three air changes about 95%, and six air changes about 99.75% — the basis of common re-entry rules.
Supply and exhaust placement determine whether air actually sweeps the breathing zone: short-circuiting between adjacent supply and exhaust can leave a room with a high nominal air change rate and almost no effective dilution.
Last updated: August 2026
Transient Purging and Air Distribution Geometry
Steady-state equations answer "how much air do I need to hold this concentration?" Transient equations answer the questions that come up in practice: how long until the space is safe to enter, and how long after a release before the concentration falls below the limit.
1. Transient Purging and Non-Steady-State Concentration Decay
When a chemical spill occurs, a batch process finishes, or an unventilated storage room must be cleared prior to worker entry, contaminant generation ceases (G = 0), and ventilation air purges the space over time. Concentration reduction follows first-order exponential decay kinetics . +-------------------------------------------------------------------------+
- | TRANSIENT EXPONENTIAL PURGE DECAY |
- +-------------------------------------------------------------------------+
- | |
- | Concentration (C) |
- | ^ |
- | C1|---* |
- | | \ |
- | | \ |
- | | \ |
- | | '. |
- | | \_ |
- | C2|-----------'-._________ |
- | +------------------------------------> Time (t) |
- | 0 Purge Time (Δt) |
- | |
- | Master Equation: ln(C1 / C2) = (Q × Δt × K') / V |
- | Time to Purge: Δt = (V / [Q × K']) × ln(C1 / C2) |
- +-------------------------------------------------------------------------+
- Derivation of the Exponential Purge Equation
The instantaneous rate of change of contaminant mass in a room of volume V (extft³) with zero ongoing generation (G = 0) is governed by the differential mass balance: V d C d t = − Q ′ ⋅ C ( t ) = − ( Q ⋅ K ′ ) ⋅ C ( t ) V \frac{dC}{dt} = -Q' \cdot C(t) = - (Q \cdot K') \cdot C(t) V d t d C = − Q ′ ⋅ C ( t ) = − ( Q ⋅ K ′ ) ⋅ C ( t )
Where:
- V = Room volume (extft³)
- C(t) = Contaminant concentration at time t
- Q = Total volumetric airflow rate (extcfm)
K' = Fractional mixing factor (K' = 1/K, where 0 < K' ≤ 1.0; K' = 1.0 represents ideal mixing, while K' = 0.2 corresponds to K = 5)
Q' = Q · K' = Effective dilution airflow rate (extcfm)
Separating variables and integrating from initial concentration C1 at t = 0 to final concentration C2 at time Δ t: ∫ C 1 C 2 d C C = − Q ⋅ K ′ V ∫ 0 Δ t d t \int_{C_1}^{C_2} \frac{dC}{C} = -\frac{Q \cdot K'}{V} \int_{0}^{\Delta t} dt ∫ C 1 C 2 C d C = − V Q ⋅ K ′ ∫ 0 Δ t d t ln ( C 2 C 1 ) = − Q ⋅ K ′ V Δ t ⟺ ln ( C 1 C 2 ) = Q ⋅ K ′ V Δ t = Q ⋅ Δ t K ⋅ V \ln\left(\frac{C_2}{C_1}\right) = -\frac{Q \cdot K'}{V} \Delta t \quad \Longleftrightarrow \quad \mathbf{\ln\left(\frac{C_1}{C_2}\right) = \frac{Q \cdot K'}{V} \Delta t = \frac{Q \cdot \Delta t}{K \cdot V}} ln ( C 1 C 2 ) = − V Q ⋅ K ′ Δ t ⟺ ln ( C 2 C 1 ) = V Q ⋅ K ′ Δt = K ⋅ V Q ⋅ Δt
Master Equation for Purge Time (Δ t)
Solving explicitly for the time required (Δ t, in minutes) to purge a room from concentration C1 down to target concentration C2: Δ t = V Q ⋅ K ′ ln ( C 1 C 2 ) = K ⋅ V Q ln ( C 1 C 2 ) \mathbf{\Delta t = \frac{V}{Q \cdot K'} \ln\left(\frac{C_1}{C_2}\right) = \frac{K \cdot V}{Q} \ln\left(\frac{C_1}{C_2}\right)} Δt = Q ⋅ K ′ V ln ( C 2 C 1 ) = Q K ⋅ V ln ( C 2 C 1 )
Air Changes per Hour (ACH) Relationship
The nominal room air change rate (N, in hr⁻¹) is defined as: N = Q × 60 V ⟺ Q V = N 60 N = \frac{Q \times 60}{V} \quad \Longleftrightarrow \quad \frac{Q}{V} = \frac{N}{60} N = V Q × 60 ⟺ V Q = 60 N
Substituting N into the purge equation yields the purge time in hours (thr) or minutes (Δ t): Δ t = 60 N ⋅ K ′ ln ( C 1 C 2 ) = 60 ⋅ K N ln ( C 1 C 2 ) [ minutes ] \Delta t = \frac{60}{N \cdot K'} \ln\left(\frac{C_1}{C_2}\right) = \frac{60 \cdot K}{N} \ln\left(\frac{C_1}{C_2}\right) \quad [\text{minutes}] Δ t = N ⋅ K ′ 60 ln ( C 2 C 1 ) = N 60 ⋅ K ln ( C 2 C 1 ) [ minutes ]
Non-Steady-State Concentration Build-Up (Continuous Generation)
If a continuous source is introduced into an initially clean room (C0 = 0) with constant generation G, the concentration build-up over time t approaches steady state exponentially: C ( t ) = G × 10 6 Q ⋅ K ′ ( 1 − e − Q ⋅ K ′ V t ) = C steady-state ( 1 − e − Q ⋅ K ′ V t ) C(t) = \frac{G \times 10^6}{Q \cdot K'} \left(1 - e^{-\frac{Q \cdot K'}{V} t}\right) = C_{\text{steady-state}} \left(1 - e^{-\frac{Q \cdot K'}{V} t}\right) C ( t ) = Q ⋅ K ′ G × 1 0 6 ( 1 − e − V Q ⋅ K ′ t ) = C steady-state ( 1 − e − V Q ⋅ K ′ t )
At t = V/(Q · K') (1 effective time constant), C(t) = 63.2% of steady state.
At t = 3 × V/(Q · K'), C(t) = 95.0% of steady state.
At t = 4.6 × V/(Q · K'), C(t) = 99.0% of steady state.
2. Air Distribution Geometry and Supply/Exhaust Placement
The physical location of supply air diffusers and exhaust air grilles determines the flow streamlines and actual mixing efficiency across the workspace. +-------------------------------------------------------------------------+
- | SUPPLY AND EXHAUST AIR DISTRIBUTION |
- +-------------------------------------------------------------------------+
- | |
- | A. CORRECT DILUTION GEOMETRY (Sweeping Fresh Air): |
- | Fresh supply air enters behind the worker, sweeps across the |
- | breathing zone, carries contaminant away from worker into exhaust. |
- | |
- | [Supply Diffuser] ===> ( Worker ) ===> [ Source ] ===> [ Exhaust ] |
- | Fresh Air ----------> Clean ----------> Vapor --------> Waste |
- | |
- | B. INCORRECT DILUTION GEOMETRY (Contaminant Pulled Over Worker): |
- | Fresh air enters opposite, pulling concentrated vapors directly |
- | through the worker's breathing zone before reaching the exhaust! |
- | |
- | [Supply Diffuser] ===> [ Source ] ===> ( Worker ) ===> [ Exhaust ] |
- | Fresh Air ----------> Vapor --------> Exposure! -------> Waste |
- | |
- | C. SHORT-CIRCUITING FAULT: |
- | Supply and exhaust grilles placed adjacent on ceiling; fresh air |
- | bypasses room volume, leaving stagnant contaminant pools below. |
- | |
- | [Supply Diffuser] ===== (Direct Bypass) =====> [Exhaust Grille] |
- | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
- | [ Stagnant Contaminant Zone ] |
- +-------------------------------------------------------------------------+
- Key Aerodynamic Distribution Rules
Sweeping Airflow Trajectory: Supply air must be introduced so that it passes through the worker's breathing zone before it reaches the contamination source, carrying vapors toward the exhaust register.
Exhaust Placement Relative to Vapor Density:
While solvent vapors diffuse in air as individual molecules (molecular weight effects are largely dominated by turbulent convection at low concentrations), heavy solvent evaporation pools near the floor benefit from low-level exhaust grilles (6--12 inches above the floor) to capture high-density boundary layers.
Buoyant thermal plumes (warm gases, steam) require high ceiling exhausts .
Elimination of Short-Circuiting: Supply inlets and exhaust registers must be separated across the room footprint to prevent clean supply air from immediately entering the exhaust register without mixing throughout the occupied zone.
Cross-Draft Minimization: Supply jet discharge velocities must be engineered to prevent high-velocity drafts (> 50 fpm) from impinging upon nearby local exhaust hoods or disrupting delicate chemical fume hood sashes.
- 3. Worked Step-by-Step Calculation Examples
- Worked Example 10.1.1: Sizing Steady-State Dilution Airflow for Solvent Degreasing
Problem: A manual parts cleaning operation in an aircraft maintenance hangar evaporates 1.5 pints per hour of methyl ethyl ketone (MEK; 2-butanone).
- Molecular weight (MW) = 72.11 g/mol
- Specific gravity (SG) = 0.805
Target airborne concentration (Ctarget) = 100 ppm (OSHA PEL is 200 ppm, but company safety policy enforces a 50% action level)
Because worker proximity is moderate and room air distribution is average, the industrial hygienist specifies an empirical mixing factor K = 4.0.
Calculate the required steady-state dilution ventilation airflow rate (Q) in cubic feet per minute (extcfm).
Solution Steps:
Calculate the vapor generation rate (G) in CFM: G = 403 ⋅ S G ⋅ E R pt/hr 60 ⋅ MW G = \frac{403 \cdot SG \cdot ER_{\text{pt/hr}}}{60 \cdot \text{MW}} G = 60 ⋅ MW 403 ⋅ SG ⋅ E R pt/hr G = 403 × 0.805 × 1.5 60 × 72.11 = 486.6225 4326.6 = 0.11247 cfm of pure MEK vapor G = \frac{403 \times 0.805 \times 1.5}{60 \times 72.11} = \frac{486.6225}{4326.6} = 0.11247\text{ cfm of pure MEK vapor} G = 60 × 72.11 403 × 0.805 × 1.5 = 4326.6 486.6225 = 0.11247 cfm of pure MEK vapor
Calculate required dilution airflow (Q): Q = G × 10 6 C target × K Q = \frac{G \times 10^6}{C_{\text{target}}} \times K Q = C target G × 1 0 6 × K Q = 0.11247 × 10 6 100 ppm × 4.0 = 1124.7 × 4.0 = 4498.8 cfm ≈ 4500 cfm Q = \frac{0.11247 \times 10^6}{100\text{ ppm}} \times 4.0 = 1124.7 \times 4.0 = 4498.8\text{ cfm} \approx 4500\text{ cfm} Q = 100 ppm 0.11247 × 1 0 6 × 4.0 = 1124.7 × 4.0 = 4498.8 cfm ≈ 4500 cfm
Direct single-step formula verification: Q = 6.72 × 10 6 ⋅ S G ⋅ E R pt/hr ⋅ K MW ⋅ C target = 6.72 × 10 6 × 0.805 × 1.5 × 4.0 72.11 × 100 Q = \frac{6.72 \times 10^6 \cdot SG \cdot ER_{\text{pt/hr}} \cdot K}{\text{MW} \cdot C_{\text{target}}} = \frac{6.72 \times 10^6 \times 0.805 \times 1.5 \times 4.0}{72.11 \times 100} Q = MW ⋅ C target 6.72 × 1 0 6 ⋅ SG ⋅ E R pt/hr ⋅ K = 72.11 × 100 6.72 × 1 0 6 × 0.805 × 1.5 × 4.0 Q = 32 , 457 , 600 7211 = 4501.1 cfm ≈ 4500 cfm Q = \frac{32,457,600}{7211} = 4501.1\text{ cfm} \approx 4500\text{ cfm} Q = 7211 32 , 457 , 600 = 4501.1 cfm ≈ 4500 cfm
Result: The required dilution ventilation airflow rate is 4500 cfm .
Worked Example 10.1.2: Confined Space Purge Time Calculation
Problem: A sealed industrial storage vault with dimensions 20 ft × 30 ft × 10 ft (Volume V = 6000 ft³) contains an initial airborne toluene concentration of C1 = 800 ppm following the repair of a solvent piping leak. A portable explosion-proof ventilation blower delivering Q = 1200 cfm is connected to purge the space before entry.
Target entry concentration (C2) = 20 ppm (ACGIH TLV-TWA)
Due to internal structural racking and equipment baffling, the mixing factor is estimated at K = 3.0 (effective mixing fraction K' = 1/K = 0.3333).
Calculate the purge time (Δ t) in minutes required to safely reduce the airborne toluene concentration from 800 ppm to 20 ppm.
Solution Steps:
Identify parameters:
- Room volume V = 20 × 30 × 10 = 6000 ft³
- Airflow rate Q = 1200 cfm
- K = 3.0 → K' = 1 / 3.0 = 0.3333
- Initial concentration C1 = 800 ppm
- Final concentration C2 = 20 ppm
Calculate the concentration ratio logarithm: C 1 C 2 = 800 20 = 40.0 \frac{C_1}{C_2} = \frac{800}{20} = 40.0 C 2 C 1 = 20 800 = 40.0 ln ( 40.0 ) = 3.6889 \ln(40.0) = 3.6889 ln ( 40.0 ) = 3.6889
Calculate purge time (Δ t): Δ t = V ⋅ K Q ln ( C 1 C 2 ) = 6000 × 3.0 1200 × 3.6889 \Delta t = \frac{V \cdot K}{Q} \ln\left(\frac{C_1}{C_2}\right) = \frac{6000 \times 3.0}{1200} \times 3.6889 Δ t = Q V ⋅ K ln ( C 2 C 1 ) = 1200 6000 × 3.0 × 3.6889 Δ t = 18000 1200 × 3.6889 = 15.0 × 3.6889 = 55.33 minutes ≈ 55.3 minutes \Delta t = \frac{18000}{1200} \times 3.6889 = 15.0 \times 3.6889 = 55.33\text{ minutes} \approx 55.3\text{ minutes} Δ t = 1200 18000 × 3.6889 = 15.0 × 3.6889 = 55.33 minutes ≈ 55.3 minutes
Result: The blower must operate for 55.3 minutes before workers may enter the space without air-supplied respirators.
Worked Example 10.1.3: Concentration Build-Up During Non-Steady-State Operation
Problem: A paint mixing room of volume V = 10,000 ft³ has a continuous dilution ventilation rate Q = 2000 cfm with a mixing factor K = 2.0 (K' = 0.50). An open dip tank begins continuously releasing acetone vapor at a generation rate G = 0.20 cfm. Assuming the room was initially clean (C0 = 0 ppm), calculate the acetone concentration in the room after 15 minutes of operation.
Solution Steps:
Calculate steady-state concentration (Css): C ss = G × 10 6 Q ⋅ K ′ = 0.20 × 10 6 2000 × 0.50 = 200 , 000 1000 = 200 ppm C_{\text{ss}} = \frac{G \times 10^6}{Q \cdot K'} = \frac{0.20 \times 10^6}{2000 \times 0.50} = \frac{200,000}{1000} = 200\text{ ppm} C ss = Q ⋅ K ′ G × 1 0 6 = 2000 × 0.50 0.20 × 1 0 6 = 1000 200 , 000 = 200 ppm
Calculate the exponential time constant term ((Q · K')/V t): Q ⋅ K ′ V t = 2000 × 0.50 10 , 000 × 15 = 1000 10 , 000 × 15 = 0.10 × 15 = 1.50 \frac{Q \cdot K'}{V} t = \frac{2000 \times 0.50}{10,000} \times 15 = \frac{1000}{10,000} \times 15 = 0.10 \times 15 = 1.50 V Q ⋅ K ′ t = 10 , 000 2000 × 0.50 × 15 = 10 , 000 1000 × 15 = 0.10 × 15 = 1.50
Calculate concentration at t = 15 min: C ( 15 ) = C ss ( 1 − e − 1.50 ) C(15) = C_{\text{ss}} \left(1 - e^{-1.50}\right) C ( 15 ) = C ss ( 1 − e − 1.50 ) e − 1.50 = 0.2231 e^{-1.50} = 0.2231 e − 1.50 = 0.2231 C ( 15 ) = 200 × ( 1 − 0.2231 ) = 200 × 0.7769 = 155.38 ppm ≈ 155 ppm C(15) = 200 \times (1 - 0.2231) = 200 \times 0.7769 = 155.38\text{ ppm} \approx 155\text{ ppm} C ( 15 ) = 200 × ( 1 − 0.2231 ) = 200 × 0.7769 = 155.38 ppm ≈ 155 ppm
Result: After 15 minutes, the airborne concentration reaches 155 ppm (77.7% of the steady-state maximum of 200 ppm).