Study guide

10.4 Particulate Transport Aerodynamics and Duct Sizing

CIH Certified Industrial Hygienist Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: The CIH Exam and How to Use This Guide

1.1 CIH Exam Format, Scoring, and Test-Day Logistics 1.2 Eligibility, Application Windows, Fees, and Certification Maintenance 1.3 The BGC Blueprint, Subject Areas, and a Calculation-First Study Plan

2 Chapter 2: Basic Science & Calculations

2.1 Gas Laws and Vapor Calculations 2.2 Unit Conversions: ppm, mg/m³, and Standard Temperature/Pressure 2.3 Fluid Mechanics and Airflow Fundamentals

3 Chapter 3: Air Sampling & Instrumentation

3.1 Active and Passive Air Sampling Strategies 3.2 Particulate and Aerosol Sampling 3.3 Direct-Reading Instruments and Calibration

4 Chapter 4: Analytical Chemistry & Lab Methods

4.1 Gas Chromatography and Mass Spectrometry 4.2 High-Performance Liquid Chromatography and Ion Chromatography 4.3 Spectroscopy and Elemental Analysis 4.4 Gravimetric, Microscopy, and Wet Chemical Methods 4.5 Laboratory Quality Assurance, Chain of Custody, and Desorption Efficiency

5 Chapter 5: Biostatistics & Epidemiology

5.1 Lognormal Distributions and Exposure Data Statistics 5.2 Upper Confidence Limits (UCL95) and Compliance Decision Rules 5.3 Epidemiological Study Designs and Measures of Association 5.4 Sampling Strategy: Sample Size, Power, and Worker Selection

6 Chapter 6: Toxicology & Biological Monitoring

6.1 Dose-Response Relationships and Points of Departure 6.2 Toxicokinetics: Absorption, Distribution, Metabolism, and Elimination 6.3 Aerosol Deposition, Clearance, and Respiratory Tract Dosimetry 6.4 Hepatic, Renal, Neurologic, and Hematologic Target Organ Toxicity 6.5 Pulmonary Toxicology, Carcinogenicity, and Reproductive Hazards 6.6 OEL Frameworks, Classifications, and Excursion Limits 6.7 Chemical Mixtures and Extended Work-Shift OEL Adjustments 6.8 Biological Exposure Indices (BEIs) and Biomonitoring

7 Chapter 7: Biohazards & Indoor Environmental Quality

7.1 Mold, Fungi, and Microbial Contaminants 7.2 Infectious Agents, Bloodborne Pathogens, and Biosafety Levels 7.3 Indoor Environmental Quality (IEQ) Investigations 7.4 Sanitation, Potable Water, and Personal Hygiene Programs

8 Chapter 8: Community Exposure & Environmental Health

8.1 Clean Air Act Framework, NAAQS, and New Source Review 8.2 Hazardous Air Pollutants, CEMS, and EPA Reference Methods 8.3 Atmospheric Stability, Lapse Rates, and Plume Morphology 8.4 Gaussian Plume Modeling, Plume Rise, and Environmental Fate 8.5 HAZWOPER Scope, Mandates, and Training Tiers 8.6 Protection Levels, Site Zoning, Incident Command, and Decontamination 8.7 Water Pollution, Hazardous Waste, and Community Right-to-Know

9 Chapter 9: Health Risk Analysis & Hazard Communication

9.1 GHS Hazard Classification: Health and Physical Hazard Criteria 9.2 GHS Labels, Safety Data Sheets, and Trade Secret Rules 9.3 The AIHA Exposure Assessment Strategy and Similar Exposure Groups 9.4 Qualitative Exposure Profiling and the AIHA Risk Matrix 9.5 Quantitative Health Risk Characterization: HQ, HI, and ELCR 9.6 NIOSH Occupational Exposure Banding 9.7 Risk Communication and Reporting to Affected Parties

10 Chapter 10: Industrial Ventilation Principles & LEV Design

10.1 Elimination, Substitution, Isolation, Containment, and Process Change 10.2 LEV Hood Taxonomy and Capture Velocity Selection 10.3 Hood Airflow Equations, Entry Losses, and Hood Static Pressure 10.4 Particulate Transport Aerodynamics and Duct Sizing 10.5 Duct Friction, Fitting Losses, and System Balancing 10.6 Fan Categories and Pressure Dynamics Across the Fan 10.7 System Curves, the Fan Laws, and Density Corrections

11 Chapter 11: General Ventilation, Air Cleaning & Diagnostics

11.1 Dilution Ventilation Principles and Steady-State Modeling 11.2 Transient Purging and Air Distribution Geometry 11.3 Particulate Air Cleaning: Cyclones, Baghouses, Scrubbers, and ESPs 11.4 Gaseous Emission Control and Air Cleaner Selection 11.5 Ventilation System Troubleshooting and Testing

12 Chapter 12: Noise Measurement & Hearing Conservation

12.1 Acoustic Physics and Decibel Mathematics 12.2 Sound Propagation, Octave Bands, and Frequency Weighting 12.3 Noise Dose Metrics and OSHA versus ACGIH Criteria 12.4 Exchange Rates, Extended Shifts, and Dosimetry Field Protocols 12.5 Engineering Noise Controls and Hearing Protector Attenuation 12.6 Hearing Conservation Programs and Standard Threshold Shifts 12.7 Hand-Arm and Whole-Body Vibration

13 Chapter 13: Thermal Stress Assessment & Control

13.1 Wet Bulb Globe Temperature (WBGT) and Heat Stress Indices 13.2 Heat-Related Disorders, Acclimatization, and Work/Rest Regimens 13.3 Cold Stress Evaluation and Wind Chill

14 Chapter 14: Ionizing Radiation Protection

14.1 Ionizing Radiation Physics and Radioactive Decay Kinetics 14.2 Radiation Units, Radiobiology, and Health Effects 14.3 ALARA, Stay-Time, and the Inverse Square Law 14.4 Shielding Physics, Material Selection, and Gamma Constants 14.5 Radiation Detection Instruments and Spectrometry 14.6 Personnel Dosimetry, Dose Limits, and Contamination Surveys

15 Chapter 15: Non-Ionizing Radiation & Laser Safety

15.1 The Non-Ionizing Spectrum and Static/ELF Field Exposures 15.2 Radiofrequency and Microwave Exposure: SAR, Standards, and Surveys 15.3 Ultraviolet, Visible, and Infrared Radiation Hazards 15.4 Laser Safety Classifications and Optical Density Calculations 15.5 Illumination, Lighting Design, and Visual Performance

16 Chapter 16: Non-Engineering Controls & Personal Protective Equipment

16.1 Respiratory Protection Programs and Assigned Protection Factors 16.2 Maximum Use Concentration, Oxygen Deficiency, and Breathing Air 16.3 Particulate Filters, Sorbent Cartridges, and Change Schedules 16.4 Respirator Fit Testing Protocols 16.5 Chemical Protective Clothing and Dermal Exposure Control

17 Chapter 17: Ergonomics & Workstation Design

17.1 Soft-Tissue Biomechanics and WMSD Pathophysiology 17.2 Ergonomic Risk Factors and Their Interaction Effects 17.3 The Revised NIOSH Lifting Equation 17.4 RULA, REBA, the Strain Index, and the ACGIH HAL TLV 17.5 Anthropometry and Workstation Geometry 17.6 VDT Workstations, Hand Tool Design, and Administrative Ergonomics

18 Chapter 18: Work Environments & Industrial Processes

18.1 Welding Fume Emissions, Metal Fume Fever, and Cr(VI)/Manganese Toxicology 18.2 Foundry Operations and Hot Work Fire Prevention 18.3 Vapor Degreasing, Pickling, Electroplating, and Cyanide Baths 18.4 Spray Coatings, Isocyanates, and Semiconductor Manufacturing 18.5 Confined Spaces and High-Hazard Industrial Operations 18.6 Asbestos, Lead, and Silica: Regulated Substance Programs 18.7 Abrasive Blasting and Surface Preparation

19 Chapter 19: IH Program Management & Professional Ethics

19.1 The BGC Code of Ethics: Canons and Enforcement 19.2 Professional Liability, Standard of Care, and Expert Testimony 19.3 Occupational Health & Safety Management Systems (ISO 45001, ANSI Z10) 19.4 Exposure Records Access and Medical Surveillance 19.5 OSHA Injury and Illness Recordkeeping and Enforcement

10.4 Particulate Transport Aerodynamics and Duct Sizing

Key Takeaways Explain This Topic AI

Minimum transport velocity prevents settling: roughly 2,000 to 2,500 fpm for vapours, gases, and fumes; 3,500 to 4,000 fpm for average industrial dust; and 4,500 fpm or more for heavy or moist material.

Settling velocity follows Stokes law for particles below about 50 µm, scaling with the square of particle diameter and with particle density.

Continuity (Q = V·A) links duct area to velocity, so undersizing a duct raises velocity and friction loss while oversizing it drops velocity below transport velocity and lets material settle out.

Round duct is preferred over rectangular because it resists collapse under negative pressure and has a lower perimeter-to-area ratio, reducing friction for the same flow.

Last updated: August 2026

Particulate Transport Aerodynamics and Duct Sizing

The ductwork system in Local Exhaust Ventilation ( LEV ) serves as the pneumatic conveying pipeline connecting the intake hoods to the air cleaning device and exhaust fan. Proper duct design must balance two competing aerodynamic requirements: maintaining sufficient air velocity to convey solid particulates without settling (preventing duct plugging and combustible dust hazards) while minimizing fluid friction and dynamic fitting losses to conserve fan electrical power.

1. Particulate Transport Aerodynamics & Settling Physics

When particulate-laden air flows through a horizontal duct, two opposing forces act upon every suspended particle:

Gravitational Sedimentation: Gravitational force accelerates particles downward at their terminal settling velocity (Vs) , governed by Stokes' Law.

Turbulent Upward Diffusion: Turbulent eddies generated by high-velocity shear stress near the duct walls impart upward velocity vectors that keep particles entrained in the fluid stream. +-------------------------------------------------------------------------+

  • | PARTICULATE DEPOSITION IN A DUCT RUN |
  • +-------------------------------------------------------------------------+
  • | |
  • | A. INSUFFICIENT VELOCITY (V_duct < V_tr): |
  • | Gravitational settling overwhelms turbulent mixing. Dust falls out |
  • | and accumulates along the bottom of horizontal ducts. |
  • | |
  • | Duct Wall -----------------------------------------------+ |
  • | ===> ===> ===> (Low Velocity Air Stream) | |
  • | . . . (Particles settle downward) | |
  • | Dust Bed -> ==============================================| |
  • | Duct Wall -----------------------------------------------+ |
  • | * Consequence: Duct plugging, reduced hood Q, combustible fire/boom!|
  • | |
  • | B. PROPER TRANSPORT VELOCITY (V_duct >= V_tr): |
  • | Turbulent eddies maintain continuous pneumatic suspension. |
  • | |
  • | Duct Wall -----------------------------------------------+ |
  • | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~| |
  • | ====> * ===> * ====> * ====> * ====| |
  • | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~| |
  • | Duct Wall -----------------------------------------------+ |
  • +-------------------------------------------------------------------------+

If the duct velocity (Vd) drops below the minimum transport velocity (Vtr) , particles settle out along the duct invert (bottom). This causes three severe failures:

Progressive Duct Choking: Accumulated dust reduces the effective cross-sectional area, increasing system resistance and starving intake hoods of design capture airflow.

Catastrophic Structural Collapse: The weight of accumulated solid dust (e.g., sand, lead dust, steel shot) can exceed duct hanger weight ratings, causing physical duct collapse.

Combustible Dust Deflagration: A thick dust bed inside ductwork provides fuel for explosive deflagration propagation (NFPA 652 / NFPA 654) if an ignition spark travels through the duct.

2. Minimum Particulate Transport Velocities (Vtr)

The ACGIH Industrial Ventilation Manual specifies standardized minimum transport velocities based on contaminant physical state, particle size, and specific gravity:

Contaminant Classification Examples & Industrial Processes Minimum Transport Velocity (Vtr)

Gases, Vapors, Smoke, Fumes Solvent vapors, acid mists, paint fumes, welding smoke (non-condensing) 1,000 to 2,000 fpm (5.0 to 10.0 m/s) (Governed by economics/noise)

Light Particulates & Dusts Cotton lint, wood flour, grain dust, tobacco, fine textile fibers 2,000 to 2,500 fpm (10.0 to 12.5 m/s)

Standard Industrial Dusts Silica sand, cement dust, limestone, dry sawdust, metal grinding dust, foundry shakeout 3,500 to 4,000 fpm (18.0 to 20.0 m/s)

Heavy or Moist Dusts Lead oxide dust, heavy foundry sand, spray paint mist, wet sawdust, sticky buffing lint 4,000 to 4,500 fpm (20.0 to 23.0 m/s)

Extremely Heavy / Settling Particulates Metal turnings, lead shot, cast iron chips, wet foundry sand, brass shavings 4,500+ fpm (23.0+ m/s, often 5,000 fpm)

Exam Rule of Thumb: For standard mineral and abrasive dusts (silica, grinding, dry wood, cement), the standard CIH design transport velocity is 3,500 to 4,000 fpm (4,000 fpm is standard). For gases, vapors, and clean air, duct velocity is sized at 1,000 to 2,000 fpm to minimize acoustic noise and fan energy consumption.

  • 3. Duct Sizing Mechanics: Continuity and Geometry
  • Duct Sizing Calculation

Duct cross-sectional area (Ad, in ft²) is calculated from volumetric flow rate (Q, in cfm) and target transport velocity (Vd, in fpm): A d = Q V d A_d = \frac{Q}{V_d} A d ​ = V d ​ Q ​

For a circular (round) duct of diameter D (in inches): A d = π ⋅ D 2 4 × 144 = π D 2 576 ⟹ D = 576 ⋅ A d π = 4 ⋅ A d π × 12 A_d = \frac{\pi \cdot D^2}{4 \times 144} = \frac{\pi D^2}{576} \implies \mathbf{D = \sqrt{\frac{576 \cdot A_d}{\pi}} = \sqrt{\frac{4 \cdot A_d}{\pi}} \times 12} A d ​ = 4 × 144 π ⋅ D 2 ​ = 576 π D 2 ​ ⟹ D = π 576 ⋅ A d ​ ​ ​ = π 4 ⋅ A d ​ ​ ​ × 12

Round vs. Rectangular Ductwork

In industrial LEV design, round ductwork is strictly preferred over rectangular ductwork for particulate conveying: +-------------------------------------------------------------------------+

  • | ROUND VS. RECTANGULAR DUCT GEOMETRY |
  • +-------------------------------------------------------------------------+
  • | |
  • | ROUND DUCT (Standard LEV): RECTANGULAR DUCT (HVAC Only): |
  • | |
  • | /-------\ +-----------------------+ |
  • | / \ | * Dead corner * | |
  • | | Uniform | | (Velocity -> 0 fpm) | |
  • | | Velocity | | Core Flow | |
  • | \ Profile / | | |
  • | \-------/ +-----------------------+ |
  • | * Dust deposits in 4 corners! |
  • | - Maximum structural hoop strength - High collapse risk under SP |
  • | - Zero dead-velocity corners - Particulate fallout corners |
  • | - Lowest sheet-metal weight per area - Higher friction per volume |
  • +-------------------------------------------------------------------------+

Aspiration Hoop Strength: Under negative static pressures (e.g., -5 to -15 in. w.g.), round ducts maintain structural rigidity. Flat-sided rectangular ducts experience high bending moments and readily collapse inward unless heavily reinforced.

Velocity Profile Uniformity: Rectangular ducts possess four 90° corners where boundary layer wall friction drops fluid velocity toward zero. Particulates deposit into these dead corners, progressively filling the duct.

Frictional Economy: Round ducts offer the minimum perimeter (wetted wall area) per unit cross-sectional area, minimizing surface drag and sheet metal material costs.