Study guide

10.6 Fan Categories and Pressure Dynamics Across the Fan

CIH Certified Industrial Hygienist Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: The CIH Exam and How to Use This Guide

1.1 CIH Exam Format, Scoring, and Test-Day Logistics 1.2 Eligibility, Application Windows, Fees, and Certification Maintenance 1.3 The BGC Blueprint, Subject Areas, and a Calculation-First Study Plan

2 Chapter 2: Basic Science & Calculations

2.1 Gas Laws and Vapor Calculations 2.2 Unit Conversions: ppm, mg/m³, and Standard Temperature/Pressure 2.3 Fluid Mechanics and Airflow Fundamentals

3 Chapter 3: Air Sampling & Instrumentation

3.1 Active and Passive Air Sampling Strategies 3.2 Particulate and Aerosol Sampling 3.3 Direct-Reading Instruments and Calibration

4 Chapter 4: Analytical Chemistry & Lab Methods

4.1 Gas Chromatography and Mass Spectrometry 4.2 High-Performance Liquid Chromatography and Ion Chromatography 4.3 Spectroscopy and Elemental Analysis 4.4 Gravimetric, Microscopy, and Wet Chemical Methods 4.5 Laboratory Quality Assurance, Chain of Custody, and Desorption Efficiency

5 Chapter 5: Biostatistics & Epidemiology

5.1 Lognormal Distributions and Exposure Data Statistics 5.2 Upper Confidence Limits (UCL95) and Compliance Decision Rules 5.3 Epidemiological Study Designs and Measures of Association 5.4 Sampling Strategy: Sample Size, Power, and Worker Selection

6 Chapter 6: Toxicology & Biological Monitoring

6.1 Dose-Response Relationships and Points of Departure 6.2 Toxicokinetics: Absorption, Distribution, Metabolism, and Elimination 6.3 Aerosol Deposition, Clearance, and Respiratory Tract Dosimetry 6.4 Hepatic, Renal, Neurologic, and Hematologic Target Organ Toxicity 6.5 Pulmonary Toxicology, Carcinogenicity, and Reproductive Hazards 6.6 OEL Frameworks, Classifications, and Excursion Limits 6.7 Chemical Mixtures and Extended Work-Shift OEL Adjustments 6.8 Biological Exposure Indices (BEIs) and Biomonitoring

7 Chapter 7: Biohazards & Indoor Environmental Quality

7.1 Mold, Fungi, and Microbial Contaminants 7.2 Infectious Agents, Bloodborne Pathogens, and Biosafety Levels 7.3 Indoor Environmental Quality (IEQ) Investigations 7.4 Sanitation, Potable Water, and Personal Hygiene Programs

8 Chapter 8: Community Exposure & Environmental Health

8.1 Clean Air Act Framework, NAAQS, and New Source Review 8.2 Hazardous Air Pollutants, CEMS, and EPA Reference Methods 8.3 Atmospheric Stability, Lapse Rates, and Plume Morphology 8.4 Gaussian Plume Modeling, Plume Rise, and Environmental Fate 8.5 HAZWOPER Scope, Mandates, and Training Tiers 8.6 Protection Levels, Site Zoning, Incident Command, and Decontamination 8.7 Water Pollution, Hazardous Waste, and Community Right-to-Know

9 Chapter 9: Health Risk Analysis & Hazard Communication

9.1 GHS Hazard Classification: Health and Physical Hazard Criteria 9.2 GHS Labels, Safety Data Sheets, and Trade Secret Rules 9.3 The AIHA Exposure Assessment Strategy and Similar Exposure Groups 9.4 Qualitative Exposure Profiling and the AIHA Risk Matrix 9.5 Quantitative Health Risk Characterization: HQ, HI, and ELCR 9.6 NIOSH Occupational Exposure Banding 9.7 Risk Communication and Reporting to Affected Parties

10 Chapter 10: Industrial Ventilation Principles & LEV Design

10.1 Elimination, Substitution, Isolation, Containment, and Process Change 10.2 LEV Hood Taxonomy and Capture Velocity Selection 10.3 Hood Airflow Equations, Entry Losses, and Hood Static Pressure 10.4 Particulate Transport Aerodynamics and Duct Sizing 10.5 Duct Friction, Fitting Losses, and System Balancing 10.6 Fan Categories and Pressure Dynamics Across the Fan 10.7 System Curves, the Fan Laws, and Density Corrections

11 Chapter 11: General Ventilation, Air Cleaning & Diagnostics

11.1 Dilution Ventilation Principles and Steady-State Modeling 11.2 Transient Purging and Air Distribution Geometry 11.3 Particulate Air Cleaning: Cyclones, Baghouses, Scrubbers, and ESPs 11.4 Gaseous Emission Control and Air Cleaner Selection 11.5 Ventilation System Troubleshooting and Testing

12 Chapter 12: Noise Measurement & Hearing Conservation

12.1 Acoustic Physics and Decibel Mathematics 12.2 Sound Propagation, Octave Bands, and Frequency Weighting 12.3 Noise Dose Metrics and OSHA versus ACGIH Criteria 12.4 Exchange Rates, Extended Shifts, and Dosimetry Field Protocols 12.5 Engineering Noise Controls and Hearing Protector Attenuation 12.6 Hearing Conservation Programs and Standard Threshold Shifts 12.7 Hand-Arm and Whole-Body Vibration

13 Chapter 13: Thermal Stress Assessment & Control

13.1 Wet Bulb Globe Temperature (WBGT) and Heat Stress Indices 13.2 Heat-Related Disorders, Acclimatization, and Work/Rest Regimens 13.3 Cold Stress Evaluation and Wind Chill

14 Chapter 14: Ionizing Radiation Protection

14.1 Ionizing Radiation Physics and Radioactive Decay Kinetics 14.2 Radiation Units, Radiobiology, and Health Effects 14.3 ALARA, Stay-Time, and the Inverse Square Law 14.4 Shielding Physics, Material Selection, and Gamma Constants 14.5 Radiation Detection Instruments and Spectrometry 14.6 Personnel Dosimetry, Dose Limits, and Contamination Surveys

15 Chapter 15: Non-Ionizing Radiation & Laser Safety

15.1 The Non-Ionizing Spectrum and Static/ELF Field Exposures 15.2 Radiofrequency and Microwave Exposure: SAR, Standards, and Surveys 15.3 Ultraviolet, Visible, and Infrared Radiation Hazards 15.4 Laser Safety Classifications and Optical Density Calculations 15.5 Illumination, Lighting Design, and Visual Performance

16 Chapter 16: Non-Engineering Controls & Personal Protective Equipment

16.1 Respiratory Protection Programs and Assigned Protection Factors 16.2 Maximum Use Concentration, Oxygen Deficiency, and Breathing Air 16.3 Particulate Filters, Sorbent Cartridges, and Change Schedules 16.4 Respirator Fit Testing Protocols 16.5 Chemical Protective Clothing and Dermal Exposure Control

17 Chapter 17: Ergonomics & Workstation Design

17.1 Soft-Tissue Biomechanics and WMSD Pathophysiology 17.2 Ergonomic Risk Factors and Their Interaction Effects 17.3 The Revised NIOSH Lifting Equation 17.4 RULA, REBA, the Strain Index, and the ACGIH HAL TLV 17.5 Anthropometry and Workstation Geometry 17.6 VDT Workstations, Hand Tool Design, and Administrative Ergonomics

18 Chapter 18: Work Environments & Industrial Processes

18.1 Welding Fume Emissions, Metal Fume Fever, and Cr(VI)/Manganese Toxicology 18.2 Foundry Operations and Hot Work Fire Prevention 18.3 Vapor Degreasing, Pickling, Electroplating, and Cyanide Baths 18.4 Spray Coatings, Isocyanates, and Semiconductor Manufacturing 18.5 Confined Spaces and High-Hazard Industrial Operations 18.6 Asbestos, Lead, and Silica: Regulated Substance Programs 18.7 Abrasive Blasting and Surface Preparation

19 Chapter 19: IH Program Management & Professional Ethics

19.1 The BGC Code of Ethics: Canons and Enforcement 19.2 Professional Liability, Standard of Care, and Expert Testimony 19.3 Occupational Health & Safety Management Systems (ISO 45001, ANSI Z10) 19.4 Exposure Records Access and Medical Surveillance 19.5 OSHA Injury and Illness Recordkeeping and Enforcement

10.6 Fan Categories and Pressure Dynamics Across the Fan

Key Takeaways Explain This Topic AI

Centrifugal fans (radial, forward-curved, backward-inclined, airfoil) develop higher static pressure and suit ducted LEV; axial fans move high volumes at low pressure and suit dilution and general ventilation.

Radial-blade fans are the rugged choice for particulate-laden and abrasive air streams; airfoil fans are the most efficient but are damaged by dust and cannot tolerate erosion.

Backward-inclined and airfoil fans are non-overloading — brake horsepower peaks and then falls as flow increases — while forward-curved fans overload the motor if system resistance drops.

Fan total pressure equals the difference in total pressure across the fan, and fan static pressure equals fan total pressure minus outlet velocity pressure.

Last updated: August 2026

Fan Categories and Pressure Dynamics Across the Fan

The industrial exhaust fan is the mechanical prime mover of a Local Exhaust Ventilation ( LEV ) system, converting electrical energy into aerodynamic fluid power. The fan creates the static pressure differential required to overcome hood entry losses, duct friction, dynamic fitting turbulence, and air cleaner pressure drops, inducing continuous contaminant capture and pneumatic transport. Selecting the correct fan type, understanding fan-system curve interactions, and mastering the Fan Laws are essential competencies for certified industrial hygienists.

1. Aerodynamic Fan Categories and Operational Profiles

Industrial fans are divided into two major aerodynamic classes based on the flow path of air through the impeller: Centrifugal Fans and Axial Fans . +-------------------------------------------------------------------------+

  • | CENTRIFUGAL VS. AXIAL FAN FLOW PATHS |
  • +-------------------------------------------------------------------------+
  • | |
  • | CENTRIFUGAL FAN (Radial Flow): AXIAL FAN (Axial Flow): |
  • | Air enters parallel to the shaft, Air enters and exits along the |
  • | turns 90°, and is accelerated same parallel longitudinal axis |
  • | radially outward by centrifugal force. through the propeller/impeller. |
  • | |
  • | Outlet (Air Exits) |
  • | ^ |
  • | | |
  • | +----+----+ |
  • | | Scroll | +=======================+ |
  • | | Housing | | Cylindrical | |
  • | Inlet | (O) | | Housing | |
  • | (Air Enters)+----+----+ | (==|Propeller|==) | |
  • | ------> Drive Shaft +=======================+ |
  • | Air In ---> ---> Air Out |
  • +-------------------------------------------------------------------------+
  • Centrifugal Fan Categories

Centrifugal fans are classified by the curvature and orientation of their impeller blades: +-------------------------------------------------------------------------+

  • | CENTRIFUGAL FAN BLADE GEOMETRIES |
  • +-------------------------------------------------------------------------+
  • | |
  • | 1. RADIAL BLADE (Paddle Wheel): |
  • | - Straight, flat blades radiating from center. |
  • | - Self-cleaning, open wheel. Ideal for heavy dust & material. |
  • | - Moderate efficiency (55 - 65%). Power curve rises steadily. |
  • | |
  • | 2. BACKWARD INCLINED / AIRFOIL: |
  • | - Blades curve away from the direction of rotation. |
  • | - Highest aerodynamic efficiency (75 - 85%). Clean air / light dust.|
  • | - NON-OVERLOADING power curve (motor protected if resistance drops).|
  • | |
  • | 3. FORWARD CURVED (Squirrel Cage): |
  • | - Large number of small blades curved in direction of rotation. |
  • | - Compact, quiet HVAC supply; low static pressure (< 3 in. w.g.). |
  • | - OVERLOADING power curve. Unsuited for LEV (dust clogs cups). |
  • +-------------------------------------------------------------------------+

Radial Blade Fans ("Paddle Wheel"):

Design: Heavy steel blades oriented straight radially from the hub. Open-wheel construction provides large clearances between blades and housing.

Performance: Moderate static efficiency (55% to 65%). High static pressure capability (up to 30 in. w.g. or more).

Industrial Hygiene Application: The industry workhorse for material handling and heavy particulate exhaust. Ideal for conveying heavy mineral dusts, wood shavings, buffing lint, metal grindings, and sticky particulates. Self-cleaning blade geometry prevents particulate deposition and wheel unbalance.

Backward-Inclined / Backward-Curved / Airfoil Fans:

Design: Heavy backward-swept blades (or streamlined aerodynamic hollow airfoil blades) leaning away from the direction of rotation.

Performance: Highest aerodynamic efficiency (75% to 85%) of any centrifugal class. Operates at higher rotational speeds.

Power Curve Characteristic: Non-overloading power curve. Brake horsepower reaches a maximum near the point of peak efficiency and then flattens or decreases as airflow increases toward free delivery. If a duct breaks or system resistance drops, the motor will not draw excessive current or burn out.

Application: Clean air exhaust, gas/vapor collection, HVAC supply, and downstream of high-efficiency dust collectors (baghouses, scrubbers) where air is particulate-free.

Forward-Curved Fans ("Squirrel-Cage"):

Design: Many shallow blades curved forward in the direction of rotation.

Performance: Delivers high volumetric flow at low rotational speeds and low static pressures (< 2.5--3.0 in. w.g.). Low efficiency (50% to 60%).

Power Curve Characteristic: Severely overloading power curve. Power rises exponentially with increasing airflow.

Application: HVAC clean air supply and residential blowers. Strictly unsuited for industrial LEV particulate exhaust because dust rapidly accumulates inside the concave cup pockets of the blades, severely unbalancing the wheel and causing catastrophic bearing failure.

Axial Fan Categories

Axial fans move air parallel to the impeller rotational axis:

Propeller Fans (Panel / Wall Fans):

Operates against negligible static pressure (< 0.5 in. w.g.). Moves large air volumes at low cost. Used exclusively for general dilution ventilation, warehouse wall exhaust, and roof purge units .

Tubeaxial Fans:

Heavy-duty propeller encased in a cylindrical duct section. Develops medium static pressures (up to 2.0--2.5 in. w.g.). Used in ducted industrial applications without high particulate loadings, such as paint spray booths and solvent drying tunnels .

Vaneaxial Fans:

Highly engineered axial impeller housed in a precision casing equipped with downstream aerodynamic stator guide vanes . The guide vanes straighten the rotating helical discharge swirl, recovering rotational kinetic energy into usable static pressure.

Develops high static pressures (up to 8.0--10.0 in. w.g.) with high efficiencies (75% to 85%). Used in compact inline industrial ventilation, marine exhaust, and underground tunnel ventilation .

Fan Category & Type Static Efficiency Pressure Range Particulate Tolerance Power Curve Primary Industrial Hygiene Application

Radial Blade Centrifugal 55%--65% Very High (> 20 in. w.g.) Excellent (Heavy dust, abrasive solids) Rising / Overloading Raw material pneumatic conveying, abrasive grinding, foundry dust exhaust.

Backward Inclined Centrifugal 75%--85% High (up to 15 in. w.g.) Poor to Fair (Clean air / fine mist) Non-Overloading Clean air LEV, solvent vapor exhaust, baghouse exhaust side.

Forward Curved Centrifugal 50%--60% Low (< 3 in. w.g.) Very Poor (Dust clogs blades) Strongly Overloading Clean makeup air units, HVAC supply, low-pressure package units.

Propeller Axial 40%--50% Near Zero (< 0.5 in. w.g.) Fair (Direct drive) Overloads at high SP General dilution, wall purge exhaust, cooling towers.

Tubeaxial 50%--65% Low-Med (< 2.5 in. w.g.) Fair (Belt-drive isolated) Overloads at high SP Spray paint booth exhaust, ducted vapor exhaust.

Vaneaxial 75%--85% High (up to 10 in. w.g.) Moderate (Clean/fume) Moderate overload Straight-through inline LEV, mine ventilation, marine systems.

2. Pressure Dynamics Across the Fan: FTP, FSP, and VP

To specify and test an industrial fan, an industrial hygienist must define total, static, and velocity pressures at the fan inlet (suction) and fan outlet (discharge). +-------------------------------------------------------------------------+

  • | PRESSURE PROFILE ACROSS AN LEV EXHAUST SYSTEM |
  • +-------------------------------------------------------------------------+
  • | Pressure (in. w.g.) |
  • | (+) | * TP_outlet |
  • | | /| |
  • | | / |* SP_outlet |
  • | 0.0 +--------------------------------/--+----------------------------> |
  • | | Hood Entry / | Stack Discharge |
  • | | * SPh / | |
  • | | \ Duct Friction / | |
  • | | \ Losses / | |
  • | | \--------* TP_inlet / | |
  • | (-) | \ / | |
  • | | \ / | |
  • | | * SP_inlet | |
  • | +-----------------------------------+----------------------------+ |
  • | [ HOOD ] ===> [ DUCT ] ===> [ FAN ] ===> [ STACK ] |
  • +-------------------------------------------------------------------------+
  • Fan Total Pressure (FTP)

Fan Total Pressure (FTP) is the total mechanical energy per unit volume imparted by the fan to the airstream, calculated as the algebraic difference between Total Pressure at the fan outlet (TPoutlet) and Total Pressure at the fan inlet (TPinlet): F T P = T P outlet − T P inlet = ( S P outlet + V P outlet ) − ( S P inlet + V P inlet ) FTP = TP_{\text{outlet}} - TP_{\text{inlet}} = (SP_{\text{outlet}} + VP_{\text{outlet}}) - (SP_{\text{inlet}} + VP_{\text{inlet}}) FTP = T P outlet ​ − T P inlet ​ = ( S P outlet ​ + V P outlet ​ ) − ( S P inlet ​ + V P inlet ​ )

Fan Static Pressure (FSP)

Fan Static Pressure (FSP) is defined by AMCA (Air Movement and Control Association) as the Fan Total Pressure minus the fan outlet velocity pressure (VPoutlet): F S P = F T P − V P outlet FSP = FTP - VP_{\text{outlet}} FSP = FTP − V P outlet ​

Substituting FTP = (SPoutlet + VPoutlet) - (SPinlet + VPinlet) into the FSP equation yields: F S P = S P outlet − S P inlet − V P inlet \mathbf{FSP = SP_{\text{outlet}} - SP_{\text{inlet}} - VP_{\text{inlet}}} FSP = S P outlet ​ − S P inlet ​ − V P inlet ​

Exam Key Formulation: When a fan exhausts directly to the outdoors without an outlet discharge duct (SPoutlet = 0), the equation simplifies to: FSP = |SPinlet| - VPinlet.