Study guide
Solution Sensitivities, Incompatibilities & Adverse Reactions
NCLE CLRE Contact Lens Registry Exam Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
0.1 About the CLRE Exam 0.2 How to Use This Study Guide
2 Ocular Anatomy: Adnexa
Tear Film: Layers, Glands & Break-Up Time Conjunctiva, Lids, Lashes, Fornix & Canthi Blink Rate, Lid Function & Contact Lens Wear Effects
3 Ocular Anatomy: Anterior & Posterior Segment
Corneal Layers, Curvature, Topography & Metabolism Iris, Pupil, Sclera & Anterior Chamber Crystalline Lens, Retina, Choroid & Posterior Chamber
4 Refractive Errors & Contact Lens Optics
Myopia, Hyperopia, Astigmatism, Presbyopia & Anisometropia Refraction, Prism, Lacrimal Lens, Accommodation & Transposition Vertex Distance, Sagittal Depth & Spherical Equivalent
5 Measurement Instrumentation
Keratometer/Ophthalmometer: Calibration, Readings & Interpretation Corneal Topography & OCT for Contact Lens Fitting Schirmer Tests & Tear Break-Up Time
6 Observation & Verification Instrumentation
Slit Lamp (Biomicroscope) Operation & Illumination Slit Lamp Evaluation With & Without Contact Lenses Radiuscope, Lensometer, Thickness Gauge & ANSI Z80
7 Prefitting Patient Evaluation
6.1 Lifestyle, Occupation, Environment & Motivation 6.2 Medical History, Diseases, Medications & Allergies 6.3 Contraindications & Factors for Successful Wear 6.4 Relating Corneal Measurements, Rx & Lens Parameters
8 Lens Materials, Design & Parameter Selection
Dk, Dk/t, Thermal Conductivity & Holden-Mertz Water Content, Wetting Angle, Modulus, Silicone Hydrogel & Surface Treatments Toric, Multifocal, Aspheric, Hybrid, Scleral, Orthokeratology & Quadrant-Specific Base Curve, Peripheral Curves, Diameter, Thickness, Power & Edge Design
9 Diagnostic Fitting Procedures
8.1 Lens Selection & Application Procedures 8.2 Fluorescein Pattern Evaluation for RGP Lenses 8.3 Soft Lens Movement, Centration & Coverage
10 Fit Evaluation & Over-Refraction
Toric Lens Axis Rotation, LARS Rule & Stabilization Patient Comfort, Visual Acuity & Over-Refraction Modifying Base Curve, Diameter, Sag & Power from Findings
11 Dispensing: Wearing Schedules & Replacement
Daily, Flexible & Extended/Continuous Wear Schedules Daily, Biweekly, Monthly & Conventional Replacement Adaptation Protocols & Patient Compliance Counseling
12 Dispensing: Lens Care Systems
Solution Compatibility with Lens Types Chemical, Heat/UV, Hydrogen Peroxide & Neutralization Surfactant Cleaners, Protein Removers & Weekly Cleaning Solution Sensitivities, Incompatibilities & Adverse Reactions
13 Dispensing: Handling & Hygiene
12.1 Soft Lens Insertion & Removal Techniques 12.2 RGP Insertion, Removal & Emergency Responses 12.3 Hygiene, Soaps, Cosmetics & Storage Containers 12.4 Verifying Lens Parameters Against the Order at Dispensing
14 Follow-Up: Subjective & Objective Findings
13.1 Subjective Complaints: Dryness, Awareness, Blurry Vision, Pain & Photophobia 13.2 Steep vs Flat Lens Fit (Rigid & Soft) & Everted Lens 13.3 Injection, Edema, Discharge, Vision Loss & Lid Problems 13.4 Visual Acuity, Over-Refraction & Gross Evaluation Techniques
15 Follow-Up: Staining Patterns & Complications
14.1 Staining Patterns: 3 & 9 O'Clock, Foreign Body, SPK, Arcuate, Smile & Dimple Veiling 14.2 SEAL, CLARE, VLK, SLK & CLPU 14.3 Microbial Keratitis, Acanthamoeba, Dendritic Ulcer & Infiltrates 14.4 Corneal Molding/Warpage, Dellen & Mucin Balls
16 Follow-Up: Management Protocols
GPC, Blepharitis, Ptosis & Tarsal Plate Evaluation Daily Wear, Extended, Therapeutic, Postsurgical & Pathology Protocols Changing Lens Parameters at Follow-Up & Documenting Records
17 Regulatory & Administrative
FCLCA, FDA, FTC, Contact Lens Rule & Prescriber Verification HIPAA, PHI, OSHA, CDC, ANSI & Universal Precautions Record Retention, Inventory, Ordering & Documentation Methodology
Solution Sensitivities, Incompatibilities & Adverse Reactions
Key Takeaways Explain This Topic AI
Solution sensitivities are allergic or immune reactions to preservatives—thimerosal has the highest historical sensitivity rate; polyquad has the lowest
Solution-induced corneal staining (SICS) presents as diffuse punctate staining 2–8 hours after insertion and is most associated with certain SiHy + MPS combinations
Hydrogen peroxide systems and daily disposable lenses are the two management strategies for patients with confirmed solution sensitivity
Some silicone hydrogel materials sorb preservatives (PHMB, alexidine), causing both reduced disinfection and delayed toxicity; verify material-solution compatibility in manufacturer labeling
Solution contamination can cause CLPU (contact lens–induced peripheral ulcer) and infiltrative keratitis; tap water exposure specifically introduces Acanthamoeba
Last updated: July 2026
Solution Sensitivities, Incompatibilities & Adverse Reactions
Quick Answer: Solution sensitivities are allergic or immune reactions to preservatives— thimerosal (mercury-based) has the highest historical sensitivity rate; polyquad the lowest. SICS (solution-induced corneal staining) appears as diffuse punctate staining 2–8 hours after insertion with certain SiHy + MPS combinations. Incompatibilities arise when a SiHy material sorbs a preservative, reducing disinfection and causing delayed toxicity. Management is to switch to hydrogen peroxide (preservative-free) or daily disposable lenses. Tap water exposure introduces Acanthamoeba and is categorically prohibited.
Solution Sensitivities (Preservative Allergies)
A solution sensitivity is a type IV (delayed hypersensitivity) immune reaction to a preservative in the care solution. Symptoms typically build over days to weeks of use and include:
- Redness, itching, burning on insertion
- Conjunctival injection, chemosis
- Follicles on the inferior palpebral conjunctiva ( hallmark sign)
- Papillary reaction in chronic cases
- Mucous discharge
- Foreign body sensation
- Common Culprit Preservatives (Ranked by Sensitivity Risk)
- Preservative Class Sensitivity Risk
- Thimerosal Mercury organic Very high — largely removed from U.S. CL solutions
- Chlorhexidine Biguanide (cationic) High — causes both toxicity and hypersensitivity
- Sorbic acid Organic acid Moderate
- PHMB (polyhexanide) Biguanide Low–moderate, but sorbed by some SiHy materials
- Alexidine Biguanide Low–moderate
- Polyquad (polyquaternium-1) Quaternary ammonium Lowest — large molecule does not penetrate corneal epithelium
- Management of Preservative Sensitivity
- Discontinue the offending solution
Switch to a hydrogen peroxide system — preservative-free after neutralization, eliminates further preservative exposure
Consider daily disposable lenses — eliminates the care system entirely, ideal for recurrent sensitizers
Counsel the patient that symptoms should resolve within 1–2 weeks of switching; persistent symptoms warrant evaluation for GPC or other causes
Incompatibilities: Preservative Sorption by SiHy Materials
Silicone hydrogel lenses have variable surface chemistry. Some SiHy materials (notably older generations with plasma surface treatment or certain wetting agents) sorb preservatives from MPS into the lens matrix. Two clinical consequences follow:
Reduced disinfection efficacy — the preservative concentration in solution drops below the effective kill threshold
Delayed preservative release — the lens releases the bound preservative onto the cornea after insertion, causing toxicity or hypersensitivity
This is the mechanism behind SICS (solution-induced corneal staining). The classic presentation is diffuse punctate staining 2–8 hours after insertion in a SiHy wearer using a PHMB-based MPS. Polyquad-based MPS is generally less prone to SICS because the larger molecule does not penetrate the lens matrix as readily.
- SICS Clinical Features
- Onset 2–8 hours after lens insertion
- Diffuse, fine punctate staining across the cornea
- Mild irritation or foreign body sensation; may be asymptomatic
- Bilateral, symmetrical pattern
- Resolves when the offending solution is discontinued
- Management of SICS
- Switch to a polyquad-based MPS or peroxide system
- Verify SiHy material compatibility in the solution manufacturer's labeling
- Document the reaction in the patient record
- Re-evaluate at 1 week to confirm resolution
- Adverse Reactions Beyond SICS
- Solution Toxicity
Solution toxicity is a direct chemical injury to the corneal epithelium, distinct from hypersensitivity. Causes include:
- Inserting a lens from an unneutralized peroxide case (chemical burn)
- Using a daily cleaner without rinsing completely
- Using expired or contaminated solution
- Using a solution not approved for the lens material
Toxicity presents with acute, severe punctate staining , often in a pattern matching the lens edge or pooling zone, accompanied by pain, redness, and tearing.
Papillary Reaction to Solutions
Chronic preservative exposure can trigger a papillary reaction that resembles GPC but is solution-driven. Signs include:
- Large papillae on the upper tarsal conjunctiva
- Mucous discharge
- Itching and lens intolerance
Switching to peroxide or daily disposable lenses typically resolves the reaction over 2–4 weeks.
Contact Lens–Induced Peripheral Ulcer (CLPU)
CLPU is a sterile inflammatory peripheral corneal infiltrate associated with solution contamination , lens case biofilm, or gram-positive bacterial antigens trapped under the lens. Features:
- Small (1–2 mm) white peripheral infiltrate
- Moderate pain, redness, tearing
- Often unilateral
- No epithelial defect over the infiltrate (sterile)
CLPU must be differentiated from microbial keratitis (which has an epithelial defect, larger infiltrate, and progressive course). Management includes discontinuing lens wear, replacing the lens and case, switching solutions, and referral to rule out infection.
Solution Contamination and the Lens Case
The lens case is the most common source of solution contamination in CL practice. Biofilm forms on the case walls within days of use. Risk factors for case contamination include:
- Not rubbing and rinsing the case daily
- Reusing old solution ("topping off")
- Storing the case in a humid bathroom
- Not replacing the case every 3 months
Counseling points for case hygiene:
- Rub and rinse the case with fresh solution after each use
- Air-dry the case upside-down on a clean tissue
- Replace the case at least every 3 months (or with each new bottle of solution)
- Never top off solution—discard and refill completely
- Tap Water: Acanthamoeba Risk
Tap water exposure is the single most preventable risk factor for Acanthamoeba keratitis , a devastating protozoal infection with poor treatment outcomes. Risk scenarios include:
- Rinsing lenses or the case under the faucet
- Showering in lenses
- Swimming in lenses (pool, lake, ocean, hot tub)
- Using homemade saline or distilled water
- Storing lenses in non-sterile water overnight
Acanthamoeba keratitis presents with severe pain out of proportion to findings , ring infiltrate, epithelial irregularity, and a course that can mimic HSV keratitis. Suspected Acanthamoeba is an ocular emergency requiring immediate ophthalmology referral.
Documentation and Follow-Up
When a solution-related adverse reaction is identified, document:
- The specific solution, lot number, and manufacturer
- The lens material and parameters
- The clinical findings (staining pattern, injection, follicles/papillae)
- The management plan (switch to peroxide, change lens modality, etc.)
- Patient education provided
- Follow-up interval
This documentation supports both patient care and FDA MedWatch adverse event reporting when warranted.