Study guide
12.1 Soft Lens Insertion & Removal Techniques
NCLE CLRE Contact Lens Registry Exam Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
0.1 About the CLRE Exam 0.2 How to Use This Study Guide
2 Ocular Anatomy: Adnexa
Tear Film: Layers, Glands & Break-Up Time Conjunctiva, Lids, Lashes, Fornix & Canthi Blink Rate, Lid Function & Contact Lens Wear Effects
3 Ocular Anatomy: Anterior & Posterior Segment
Corneal Layers, Curvature, Topography & Metabolism Iris, Pupil, Sclera & Anterior Chamber Crystalline Lens, Retina, Choroid & Posterior Chamber
4 Refractive Errors & Contact Lens Optics
Myopia, Hyperopia, Astigmatism, Presbyopia & Anisometropia Refraction, Prism, Lacrimal Lens, Accommodation & Transposition Vertex Distance, Sagittal Depth & Spherical Equivalent
5 Measurement Instrumentation
Keratometer/Ophthalmometer: Calibration, Readings & Interpretation Corneal Topography & OCT for Contact Lens Fitting Schirmer Tests & Tear Break-Up Time
6 Observation & Verification Instrumentation
Slit Lamp (Biomicroscope) Operation & Illumination Slit Lamp Evaluation With & Without Contact Lenses Radiuscope, Lensometer, Thickness Gauge & ANSI Z80
7 Prefitting Patient Evaluation
6.1 Lifestyle, Occupation, Environment & Motivation 6.2 Medical History, Diseases, Medications & Allergies 6.3 Contraindications & Factors for Successful Wear 6.4 Relating Corneal Measurements, Rx & Lens Parameters
8 Lens Materials, Design & Parameter Selection
Dk, Dk/t, Thermal Conductivity & Holden-Mertz Water Content, Wetting Angle, Modulus, Silicone Hydrogel & Surface Treatments Toric, Multifocal, Aspheric, Hybrid, Scleral, Orthokeratology & Quadrant-Specific Base Curve, Peripheral Curves, Diameter, Thickness, Power & Edge Design
9 Diagnostic Fitting Procedures
8.1 Lens Selection & Application Procedures 8.2 Fluorescein Pattern Evaluation for RGP Lenses 8.3 Soft Lens Movement, Centration & Coverage
10 Fit Evaluation & Over-Refraction
Toric Lens Axis Rotation, LARS Rule & Stabilization Patient Comfort, Visual Acuity & Over-Refraction Modifying Base Curve, Diameter, Sag & Power from Findings
11 Dispensing: Wearing Schedules & Replacement
Daily, Flexible & Extended/Continuous Wear Schedules Daily, Biweekly, Monthly & Conventional Replacement Adaptation Protocols & Patient Compliance Counseling
12 Dispensing: Lens Care Systems
Solution Compatibility with Lens Types Chemical, Heat/UV, Hydrogen Peroxide & Neutralization Surfactant Cleaners, Protein Removers & Weekly Cleaning Solution Sensitivities, Incompatibilities & Adverse Reactions
13 Dispensing: Handling & Hygiene
12.1 Soft Lens Insertion & Removal Techniques 12.2 RGP Insertion, Removal & Emergency Responses 12.3 Hygiene, Soaps, Cosmetics & Storage Containers 12.4 Verifying Lens Parameters Against the Order at Dispensing
14 Follow-Up: Subjective & Objective Findings
13.1 Subjective Complaints: Dryness, Awareness, Blurry Vision, Pain & Photophobia 13.2 Steep vs Flat Lens Fit (Rigid & Soft) & Everted Lens 13.3 Injection, Edema, Discharge, Vision Loss & Lid Problems 13.4 Visual Acuity, Over-Refraction & Gross Evaluation Techniques
15 Follow-Up: Staining Patterns & Complications
14.1 Staining Patterns: 3 & 9 O'Clock, Foreign Body, SPK, Arcuate, Smile & Dimple Veiling 14.2 SEAL, CLARE, VLK, SLK & CLPU 14.3 Microbial Keratitis, Acanthamoeba, Dendritic Ulcer & Infiltrates 14.4 Corneal Molding/Warpage, Dellen & Mucin Balls
16 Follow-Up: Management Protocols
GPC, Blepharitis, Ptosis & Tarsal Plate Evaluation Daily Wear, Extended, Therapeutic, Postsurgical & Pathology Protocols Changing Lens Parameters at Follow-Up & Documenting Records
17 Regulatory & Administrative
FCLCA, FDA, FTC, Contact Lens Rule & Prescriber Verification HIPAA, PHI, OSHA, CDC, ANSI & Universal Precautions Record Retention, Inventory, Ordering & Documentation Methodology
12.1 Soft Lens Insertion & Removal Techniques
Key Takeaways Explain This Topic AI
Always wash and dry hands before handling soft lenses; non-cream soap and lint-free towels prevent deposits and contamination
Use the 'taco test' to verify orientation: a correct soft lens curls inward like a taco; if edges flare outward, the lens is inside out
Soft lenses are placed on the sclera below the cornea, never directly on the cornea; release the lower lid before the upper lid to avoid dislodging
Removal uses the temporal sclera pinch technique: look up, slide lens temporally, pinch gently between thumb and index finger
The lateral canthal insertion method is a useful alternative for patients with sensitive eyes or strong blink reflexes
Last updated: July 2026
Soft Lens Insertion & Removal Techniques
Quick Answer: Soft lens insertion follows a fixed sequence: clean hands, verify orientation with the "taco test," control the lids, place the lens on the inferior sclera, release the lower lid first, then the upper lid, and blink. Removal uses a temporal pinch after sliding the lens off the cornea.
Domain VI of the CLRE blueprint expects you to know not just the steps but the why behind each one. Fitters who can explain the rationale teach patients correctly and reduce dropouts.
Pre-Insertion Setup
Wash hands with non-cream soap; rinse thoroughly.
Dry with a lint-free towel — paper towels and terry cloth shed fibers that cling to hydrogel surfaces.
Inspect the lens for nicks, deposits, or inside-out orientation.
Verifying Orientation: The Taco Test
A soft lens can sit on the finger in one of two orientations. Inserting an inside-out lens causes immediate discomfort and poor optics.
- Orientation Appearance When Squeezed Gently Result
- Correct (right-side out) Edges curl inward like a taco shell Comfortable, optics stable
- Inside out Edges flare outward like a plate Foreign-body sensation, lens moves excessively
Some lenses also feature laser markings (typically "123" or an "OK" engraved mark) that read correctly only in the proper orientation; the taco test remains the fastest bedside check.
Standard Insertion Technique
The textbook method places the lens on the inferior sclera , not directly on the cornea. Scleral placement triggers fewer blink reflexes and lets capillary action seat the lens.
Place the lens on the tip of the index finger of the dominant hand (concave side up).
With the non-dominant middle finger, hold the upper lid against the brow bone — firm pressure prevents blinking.
With the dominant middle finger, pull the lower lid down .
Instruct the patient to look up or straight ahead .
Place the lens on the inferior sclera , just below the cornea.
Release the lower lid first — this anchors the lens against the globe.
Have the patient look down, then release the upper lid slowly .
Instruct the patient to blink gently a few times and check comfort and centration.
Repeat for the left eye (OS).
Alternate: Lateral Canthal Insertion
For patients with a strong blink reflex , hypersensitivity, or ptosis that limits upper lid control, use the lateral canthal method:
Pull both lids temporally with the index and middle fingers, creating a "stretched" interpalpebral fissure .
Place the lens on the index finger, look toward the nose, and apply the lens to the temporal sclera.
Have the patient slowly look toward the lens while releasing the lids.
This technique bypasses the central corneal reflex arc and is often taught to first-time wearers who struggle with the standard method.
Soft Lens Removal Technique
Look up — this exposes the inferior sclera and moves the lens off the visual axis.
Pull the lower lid down with the dominant middle finger.
Slide the lens to the temporal sclera using the index finger pad (never a fingernail).
Pinch gently between the thumb and index finger — the lens buckles and lifts off the ocular surface.
Place the lens in the appropriate case compartment (right or left).
Repeat for the fellow eye.
Common Insertion/Removal Errors to Avoid
Using fingernails — tears the lens edge; use finger pads only.
Placing the lens on the cornea directly — provokes an immediate blink reflex and risk of corneal abrasion.
Releasing the upper lid first — the lid sweeps the lens off the globe before the lower lid can anchor it.
Pinching too aggressively during removal — can fold the lens tightly and cause micro-tears.
Patient Education Pointers
Recommend a consistent insertion order (e.g., right eye first) to prevent mixing up lenses with different parameters.
Have new wearers practice with the non-dominant hand controlling the upper lid — dominant hand steadiness matters more for lens placement.
Warn patients that eye rubbing over a lens can displace or damage it.
Key Takeaways
The taco test is the fastest on-eye orientation check; inside-out lenses flare outward like a plate.
Soft lenses belong on the inferior sclera , not the cornea.
Release the lower lid first , then the upper lid, to seat the lens.
For sensitive patients, lateral canthal insertion bypasses the central blink reflex.
Removal combines a temporal slide with a gentle pinch to lift the lens off the sclera.