Study guide
Modifying Base Curve, Diameter, Sag & Power from Findings
NCLE CLRE Contact Lens Registry Exam Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
0.1 About the CLRE Exam 0.2 How to Use This Study Guide
2 Ocular Anatomy: Adnexa
Tear Film: Layers, Glands & Break-Up Time Conjunctiva, Lids, Lashes, Fornix & Canthi Blink Rate, Lid Function & Contact Lens Wear Effects
3 Ocular Anatomy: Anterior & Posterior Segment
Corneal Layers, Curvature, Topography & Metabolism Iris, Pupil, Sclera & Anterior Chamber Crystalline Lens, Retina, Choroid & Posterior Chamber
4 Refractive Errors & Contact Lens Optics
Myopia, Hyperopia, Astigmatism, Presbyopia & Anisometropia Refraction, Prism, Lacrimal Lens, Accommodation & Transposition Vertex Distance, Sagittal Depth & Spherical Equivalent
5 Measurement Instrumentation
Keratometer/Ophthalmometer: Calibration, Readings & Interpretation Corneal Topography & OCT for Contact Lens Fitting Schirmer Tests & Tear Break-Up Time
6 Observation & Verification Instrumentation
Slit Lamp (Biomicroscope) Operation & Illumination Slit Lamp Evaluation With & Without Contact Lenses Radiuscope, Lensometer, Thickness Gauge & ANSI Z80
7 Prefitting Patient Evaluation
6.1 Lifestyle, Occupation, Environment & Motivation 6.2 Medical History, Diseases, Medications & Allergies 6.3 Contraindications & Factors for Successful Wear 6.4 Relating Corneal Measurements, Rx & Lens Parameters
8 Lens Materials, Design & Parameter Selection
Dk, Dk/t, Thermal Conductivity & Holden-Mertz Water Content, Wetting Angle, Modulus, Silicone Hydrogel & Surface Treatments Toric, Multifocal, Aspheric, Hybrid, Scleral, Orthokeratology & Quadrant-Specific Base Curve, Peripheral Curves, Diameter, Thickness, Power & Edge Design
9 Diagnostic Fitting Procedures
8.1 Lens Selection & Application Procedures 8.2 Fluorescein Pattern Evaluation for RGP Lenses 8.3 Soft Lens Movement, Centration & Coverage
10 Fit Evaluation & Over-Refraction
Toric Lens Axis Rotation, LARS Rule & Stabilization Patient Comfort, Visual Acuity & Over-Refraction Modifying Base Curve, Diameter, Sag & Power from Findings
11 Dispensing: Wearing Schedules & Replacement
Daily, Flexible & Extended/Continuous Wear Schedules Daily, Biweekly, Monthly & Conventional Replacement Adaptation Protocols & Patient Compliance Counseling
12 Dispensing: Lens Care Systems
Solution Compatibility with Lens Types Chemical, Heat/UV, Hydrogen Peroxide & Neutralization Surfactant Cleaners, Protein Removers & Weekly Cleaning Solution Sensitivities, Incompatibilities & Adverse Reactions
13 Dispensing: Handling & Hygiene
12.1 Soft Lens Insertion & Removal Techniques 12.2 RGP Insertion, Removal & Emergency Responses 12.3 Hygiene, Soaps, Cosmetics & Storage Containers 12.4 Verifying Lens Parameters Against the Order at Dispensing
14 Follow-Up: Subjective & Objective Findings
13.1 Subjective Complaints: Dryness, Awareness, Blurry Vision, Pain & Photophobia 13.2 Steep vs Flat Lens Fit (Rigid & Soft) & Everted Lens 13.3 Injection, Edema, Discharge, Vision Loss & Lid Problems 13.4 Visual Acuity, Over-Refraction & Gross Evaluation Techniques
15 Follow-Up: Staining Patterns & Complications
14.1 Staining Patterns: 3 & 9 O'Clock, Foreign Body, SPK, Arcuate, Smile & Dimple Veiling 14.2 SEAL, CLARE, VLK, SLK & CLPU 14.3 Microbial Keratitis, Acanthamoeba, Dendritic Ulcer & Infiltrates 14.4 Corneal Molding/Warpage, Dellen & Mucin Balls
16 Follow-Up: Management Protocols
GPC, Blepharitis, Ptosis & Tarsal Plate Evaluation Daily Wear, Extended, Therapeutic, Postsurgical & Pathology Protocols Changing Lens Parameters at Follow-Up & Documenting Records
17 Regulatory & Administrative
FCLCA, FDA, FTC, Contact Lens Rule & Prescriber Verification HIPAA, PHI, OSHA, CDC, ANSI & Universal Precautions Record Retention, Inventory, Ordering & Documentation Methodology
Modifying Base Curve, Diameter, Sag & Power from Findings
Key Takeaways Explain This Topic AI
For soft lenses, a steep (tight) fit is corrected by flattening the base curve or reducing sagittal depth (smaller diameter or flatter BC); a flat (loose) fit is corrected by steepening the base curve or increasing sag (larger diameter or steeper BC).
For RGP lenses, a steep fit shows central pooling and peripheral touch — flatten the base curve; a flat fit shows central touch and peripheral clearance — steepen the base curve.
Sagittal depth (sag) is the most powerful single parameter for changing soft lens fit because sag scales with the square of diameter; a 0.5 mm diameter change can shift sag more than a 0.3 mm base-curve change.
Power modifications incorporate the over-refraction, plus the SAM/FAP adjustment when the RGP base curve changes (Steep Add Minus, Flat Add Plus).
RGP diameter choice determines fitting philosophy: larger diameter (≥9.5 mm) favors lid-attachment fitting; smaller diameter (≤9.0 mm) favors interpalpebral fitting that avoids the lid.
Last updated: July 2026
Modifying Base Curve, Diameter, Sag & Power from Findings
Quick Answer: Once you have assessed fit, comfort, and over-refraction, the next step is translating those findings into parameter changes. For soft lenses, modify sagittal depth (via base curve and/or diameter) and lens power. For RGP lenses, modify base curve, diameter, and power (using SAM/FAP). Each finding maps to a specific parameter change — this section gives you the decision tables.
- Soft Lens Fit Modifications
- Steep (Tight) Soft Lens
Findings: minimal lens movement, tight on blink, conjunctival injection, patient reports "tight" sensation, corneal edema after extended wear, reduced VA with blink, fluorescein shows central pooling with peripheral touch.
Goal: reduce sagittal depth so the lens vaults less and moves more.
- Parameter Change Effect
- Flatten base curve (e.g., 8.40 → 8.60 mm) Reduces sag; lens drapes less
- Reduce diameter (e.g., 14.5 → 14.0 mm) Reduces sag (sag ∝ diameter²); largest single effect
- Both Compounded effect; use when one change is insufficient
- Flat (Loose) Soft Lens
Findings: excessive lens movement, edge standoff visible at slit lamp, lens decentered on blink, patient reports "loose" or "floating" sensation, fluctuating VA, fluorescein shows edge lift and poor corneal coverage.
Goal: increase sagittal depth so the lens vaults more and grips better.
- Parameter Change Effect
- Steepen base curve (e.g., 8.60 → 8.40 mm) Increases sag; lens drapes more
- Increase diameter (e.g., 14.0 → 14.5 mm) Increases sag; largest single effect
- Both Compounded effect; use when one change is insufficient
- Why Sagittal Depth Matters Most
Sagittal depth (sag ≈ D²/8r, where D is diameter and r is base-curve radius) determines how much the lens vaults the cornea. Because sag scales with the square of diameter but only linearly with base-curve radius, a small diameter change can produce a larger sag shift than a typical base-curve change:
A 0.5 mm increase in diameter (e.g., 14.0 → 14.5 mm) on a lens with 8.4 mm base curve raises sag by roughly 0.20 mm
A 0.2 mm flattening of base curve (8.40 → 8.60 mm) on a 14.0 mm lens reduces sag by roughly 0.06 mm
When a soft lens needs a meaningful fit change and you can change only one parameter, change diameter first.
RGP Fit Modifications
RGP fitting relies on fluorescein pattern interpretation to assess the tear lens relationship between the rigid lens and the cornea.
Steep RGP Fit
Fluorescein pattern: central pooling (bright green pool under the optic zone), peripheral touch (dark ring at edge), minimal lens movement, air bubble may be trapped centrally.
Goal: flatten the base curve to reduce vaulting.
- Finding Action
- Central pooling, peripheral touch Flatten base curve by 0.05–0.10 mm
- Trapped air bubble Lens is too steep; flatten base curve
- Injection, tight sensation Flatten base curve; verify diameter is not too large
Power adjustment: flattening the base curve creates a minus tear lens → FAP (Flat Add Plus) → add plus power to the RGP.
Flat RGP Fit
Fluorescein pattern: central touch (dark area under optic zone where the lens contacts the cornea), peripheral clearance (bright green ring at edge), excessive lens movement, edge standoff.
Goal: steepen the base curve to increase vaulting and improve centration.
- Finding Action
- Central touch, peripheral clearance Steepen base curve by 0.05–0.10 mm
- Decentered lens, excessive movement Steepen base curve; consider larger diameter
- Edge standoff irritating lid Steepen base curve or increase diameter
Power adjustment: steepening the base curve creates a plus tear lens → SAM (Steep Add Minus) → add minus power to the RGP.
RGP Diameter and Fitting Philosophy
Diameter determines how the lens interacts with the lids:
- Diameter Range Fitting Philosophy Lid Relationship
- ≤ 9.0 mm (small) Interpalpebral Lens sits between upper and lower lids; avoids lid capture
≥ 9.5 mm (large) Lid-attachment Upper lid captures the lens under the upper lid; lens translates with down-gaze
Interpalpebral fitting is preferred when the upper lid is tight or sharply curbed (lens would be uncomfortable under the lid), or for steep corneas where lid attachment is unstable. Lid-attachment fitting is preferred for normal lid anatomy, with-the-rule astigmatism, and when translation is needed (e.g., translating bifocals).
Diameter also interacts with centration: a larger diameter centers better on a flat cornea but may irritate a tight upper lid. A smaller diameter clears a tight lid but may decenter on a flat cornea.
Power Modifications: Combining Over-Refraction with SAM/FAP
When you change only lens power (no base-curve change), add the over-refraction directly to the current lens power:
New power = current lens power + over-refraction
When you change both base curve AND power, apply SAM/FAP first, then add the over-refraction:
New power = current lens power + over-refraction + SAM/FAP adjustment
Where SAM/FAP adjustment is:
- 0.25 D per 0.05 mm steepened (SAM: steep add minus)
- +0.25 D per 0.05 mm flattened (FAP: flat add plus)
- Worked Example: RGP Power Change with Base-Curve Steepening
Current RGP: base curve 7.85 mm, power -6.00 D. Over-refraction: -0.50 DS. You steepen the base curve to 7.75 mm (0.10 mm steeper) to fix central touch.
- Over-refraction adjustment: -0.50 D
- SAM adjustment: 0.10 mm steepened = 2 × 0.05 mm = -0.50 D (add minus)
- New power = -6.00 + (-0.50) + (-0.50) = -7.00 D
- Worked Example: RGP Power Change with Base-Curve Flattening
Current RGP: base curve 7.70 mm, power -8.00 D. Over-refraction: +0.25 DS. You flatten the base curve to 7.80 mm (0.10 mm flatter) to fix central pooling.
- Over-refraction adjustment: +0.25 D
- FAP adjustment: 0.10 mm flattened = 2 × 0.05 mm = +0.50 D (add plus)
- New power = -8.00 + 0.25 + 0.50 = -7.25 D
- Decision Table: From Finding to Parameter Change
- Lens Type Finding Parameter Change Power Change
- Soft Steep (tight) Flatten BC and/or reduce diameter Add over-refraction
- Soft Flat (loose) Steepen BC and/or increase diameter Add over-refraction
- Soft Decentered (not enough coverage) Increase diameter None unless OR shows error
- Soft Edge standoff irritating lid Steepen BC or reduce diameter None unless OR shows error
- RGP Central pooling (steep) Flatten BC FAP: add plus
- RGP Central touch (flat) Steepen BC SAM: add minus
- RGP Excessive movement Steepen BC or increase diameter SAM if BC changed
RGP Decentered (interpalpebral unstable) Increase diameter or switch to lid-attachment Apply SAM/FAP if BC changed
- RGP Bubble trapped Flatten BC FAP: add plus
- Final Verification
After any parameter change, repeat the full evaluation:
- Reassess comfort, centration, movement, and fluorescein pattern (RGP) after 10–15 minutes of wear
- Repeat over-refraction — it should be closer to plano
- Confirm VA at distance (and near for multifocals)
- Verify toric axis stability across blink and gaze (Section 9.1)
- Document the final parameters and schedule follow-up
Iterative fitting is normal: expect one or two parameter modifications before arriving at the final lens. Patients should always leave with a clear follow-up plan and backup spectacles.