1 Introduction & Exam Overview
0.1 About the CLRE Exam 0.2 How to Use This Study Guide
2 Ocular Anatomy: Adnexa
Tear Film: Layers, Glands & Break-Up Time Conjunctiva, Lids, Lashes, Fornix & Canthi Blink Rate, Lid Function & Contact Lens Wear Effects
3 Ocular Anatomy: Anterior & Posterior Segment
Corneal Layers, Curvature, Topography & Metabolism Iris, Pupil, Sclera & Anterior Chamber Crystalline Lens, Retina, Choroid & Posterior Chamber
4 Refractive Errors & Contact Lens Optics
Myopia, Hyperopia, Astigmatism, Presbyopia & Anisometropia Refraction, Prism, Lacrimal Lens, Accommodation & Transposition Vertex Distance, Sagittal Depth & Spherical Equivalent
5 Measurement Instrumentation
Keratometer/Ophthalmometer: Calibration, Readings & Interpretation Corneal Topography & OCT for Contact Lens Fitting Schirmer Tests & Tear Break-Up Time
6 Observation & Verification Instrumentation
Slit Lamp (Biomicroscope) Operation & Illumination Slit Lamp Evaluation With & Without Contact Lenses Radiuscope, Lensometer, Thickness Gauge & ANSI Z80
7 Prefitting Patient Evaluation
6.1 Lifestyle, Occupation, Environment & Motivation 6.2 Medical History, Diseases, Medications & Allergies 6.3 Contraindications & Factors for Successful Wear 6.4 Relating Corneal Measurements, Rx & Lens Parameters
8 Lens Materials, Design & Parameter Selection
Dk, Dk/t, Thermal Conductivity & Holden-Mertz Water Content, Wetting Angle, Modulus, Silicone Hydrogel & Surface Treatments Toric, Multifocal, Aspheric, Hybrid, Scleral, Orthokeratology & Quadrant-Specific Base Curve, Peripheral Curves, Diameter, Thickness, Power & Edge Design
9 Diagnostic Fitting Procedures
8.1 Lens Selection & Application Procedures 8.2 Fluorescein Pattern Evaluation for RGP Lenses 8.3 Soft Lens Movement, Centration & Coverage
10 Fit Evaluation & Over-Refraction
Toric Lens Axis Rotation, LARS Rule & Stabilization Patient Comfort, Visual Acuity & Over-Refraction Modifying Base Curve, Diameter, Sag & Power from Findings
11 Dispensing: Wearing Schedules & Replacement
Daily, Flexible & Extended/Continuous Wear Schedules Daily, Biweekly, Monthly & Conventional Replacement Adaptation Protocols & Patient Compliance Counseling
12 Dispensing: Lens Care Systems
Solution Compatibility with Lens Types Chemical, Heat/UV, Hydrogen Peroxide & Neutralization Surfactant Cleaners, Protein Removers & Weekly Cleaning Solution Sensitivities, Incompatibilities & Adverse Reactions
13 Dispensing: Handling & Hygiene
12.1 Soft Lens Insertion & Removal Techniques 12.2 RGP Insertion, Removal & Emergency Responses 12.3 Hygiene, Soaps, Cosmetics & Storage Containers 12.4 Verifying Lens Parameters Against the Order at Dispensing
14 Follow-Up: Subjective & Objective Findings
13.1 Subjective Complaints: Dryness, Awareness, Blurry Vision, Pain & Photophobia 13.2 Steep vs Flat Lens Fit (Rigid & Soft) & Everted Lens 13.3 Injection, Edema, Discharge, Vision Loss & Lid Problems 13.4 Visual Acuity, Over-Refraction & Gross Evaluation Techniques
15 Follow-Up: Staining Patterns & Complications
14.1 Staining Patterns: 3 & 9 O'Clock, Foreign Body, SPK, Arcuate, Smile & Dimple Veiling 14.2 SEAL, CLARE, VLK, SLK & CLPU 14.3 Microbial Keratitis, Acanthamoeba, Dendritic Ulcer & Infiltrates 14.4 Corneal Molding/Warpage, Dellen & Mucin Balls
16 Follow-Up: Management Protocols
GPC, Blepharitis, Ptosis & Tarsal Plate Evaluation Daily Wear, Extended, Therapeutic, Postsurgical & Pathology Protocols Changing Lens Parameters at Follow-Up & Documenting Records
17 Regulatory & Administrative
FCLCA, FDA, FTC, Contact Lens Rule & Prescriber Verification HIPAA, PHI, OSHA, CDC, ANSI & Universal Precautions Record Retention, Inventory, Ordering & Documentation Methodology
Toric, Multifocal, Aspheric, Hybrid, Scleral, Orthokeratology & Quadrant-Specific
Key Takeaways Explain This Topic AI
Soft toric lenses stabilize using prism ballast, truncation, double slab-off, or peri-ballast; LARS (Left Add, Right Subtract) corrects axis rotation observed at the slit lamp.
Multifocals are either simultaneous vision (concentric, aspheric, diffractive) or alternating/translating; aspheric variants are center-near or center-distance.
Hybrid lenses (RGP center + soft skirt) solve irregular-cornea optics with RGP-quality vision and soft-lens comfort.
Scleral lenses (14.5–18+ mm) vault the cornea and land on the sclera — used for keratoconus, post-PK, severe dry eye, and ocular surface disease.
Ortho-K uses reverse-geometry RGP worn overnight to reshape the cornea, correct myopia ≤−5.00 D and astig ≤−1.50 D, and slow pediatric axial elongation.
Last updated: July 2026
Toric, Multifocal, Aspheric, Hybrid, Scleral, Orthokeratology & Quadrant-Specific Designs
Quick Answer: Lens design matches ocular geometry and visual demand. Toric designs use stabilization features to keep astigmatic correction on-axis. Multifocals use simultaneous or alternating vision. Specialty designs — hybrid, scleral, ortho-K, quadrant-specific — solve irregular-cornea, dry-eye, and myopia-control problems conventional soft lenses cannot.
Toric Lens Designs
Soft toric lenses correct ≥0.75 D of astigmatism. Because a soft lens drapes over the cornea, rotation must be controlled for the cylinder axis to align. Stabilization methods:
- Prism ballast — thicker, heavier bottom edge; gravity pulls it inferiorly
- Truncation — bottom edge cut flat to sit on the lower lid
- Double slab-off — thin top and bottom zones, thick mid-periphery; lids squeeze the lens into place
Peri-ballast — thick zones nasal and temporal to the optical zone, thin top and bottom (reduces prism-induced vertical imbalance)
LARS (Left Add, Right Subtract) : when a toric lens rotates, adjust the axis by the rotation amount — A dd for left rotation, S ubtract for right rotation. Observe the slit-lamp rotation marker (typically a laser-engraved line at 6 o'clock). A lens rotated 10° to the patient's right → subtract 10° from the manifest cylinder axis on reorder.
Multifocal Designs
Two functional classes:
Simultaneous vision — both distance and near images are presented to the retina at the same time; the visual cortex selects the in-focus image.
- Concentric (annular) rings — alternating distance/near zones
- Aspheric — power progresses from center to periphery (or periphery to center)
- Diffractive — fine concentric grooves create simultaneous near and distance foci
Aspheric sub-types :
- Center-near — add increases toward center (popular for early presbyopia, computer users)
- Center-distance — distance in center, add in periphery (better distance in low light, mature presbyopia)
Alternating / Translating — the lens physically shifts with down-gaze (reading), moving the near zone over the pupil. Truncated bottom edge rests on lower lid. Better for high add and mature presbyopia; requires lid interaction and lens movement.
- Design Mechanism Best For
- Concentric simultaneous Rings Moderate add, similar pupil sizes
- Aspheric center-near Progressive Early presbyopia, computer users
- Aspheric center-distance Progressive Mature presbyopia, distance priority
- Translating bifocal Alternating High add, mature presbyopia
Modified monovision — one eye distance, one multifocal — is a common compromise for patients who fail full bifocal fit.
Aspheric Lenses
Aspheric designs progressively flatten (or steepen) from center to periphery, reducing spherical aberration . Positive spherical aberration in conventional lenses reduces image quality in low light (large pupil). Aspheric surfaces improve contrast and reduce halo. The same aspheric geometry is used in multifocal designs and in single-vision lenses for high-quality vision.
Hybrid Lenses
Hybrid lenses combine an RGP center with a soft hydrogel or silicone hydrogel skirt. Examples: ClearKone, SynergEyes, Duette .
Indications:
- Irregular cornea (keratoconus, post-LASIK ectasia, post-PK) where RGP optics are needed but comfort is poor
- Athletes who need RGP-quality vision but cannot risk lens dislodgement
- Patients with RGP intolerance
Fitting matches the soft skirt to the scleral sag and the RGP zone to the cone; the skirt vaults the limbus. Hybrid lenses are a bridge between RGP and scleral options.
Scleral Lenses
Scleral lenses vault the entire cornea and land on the sclera. Diameter 14.5–16.0 mm (mini-scleral) to 18.0+ mm (full-scleral).
Indications:
- Keratoconus and other ectasias
- Post-penetrating keratoplasty (post-PK)
- Severe dry eye (Sjögren, GvHD) — the vaulted tear reservoir bathes the cornea
- Irregular cornea (scarred, post-refractive, post-corneal surgery)
- Ocular surface disease requiring mechanical protection
Fitting keys: vault (sagittal depth) over cornea and limbus, landing zone on sclera without compression or blanching, edge lift for tear exchange. Over-vaulting risks corneal edema; under-vaulting compresses the conjunctiva and causes vascular engorgement. Scleral lenses should show central clearance of ~150–250 µm at insertion, settling to ~50–150 µm after several hours.
Orthokeratology (Ortho-K)
Ortho-K uses a reverse-geometry RGP lens worn overnight to flatten the central cornea, temporarily reducing myopia. The lens creates a central flat zone with a steep "return curve" and a peripheral landing zone, producing corneal epithelial redistribution (central thinning, mid-peripheral thickening).
Indications:
- Myopia ≤ −5.00 D (best results at ≤ −3.00 D)
- Astigmatism ≤ −1.50 D (with-the-rule is easiest)
Myopia control in children — multiple studies show 40–60% slowing of axial elongation versus single-vision spectacles
Lenses removed on waking; effect lasts 1–2 days. Patient must wear nightly to maintain unaided daytime vision. Corneal warpage is reversible, but discontinuation returns the eye to baseline within 1–2 weeks.
Quadrant-Specific Designs
Quadrant-specific (or quadrant-asymmetric) lenses vary geometry across quadrants to match asymmetric corneas — post-LASIK with nasal steepening, pellucid marginal degeneration, post-PK with suture-induced astigmatism. Each quadrant can have independent sagittal depth, tangent, or eccentricity. Used in specialty RGP, scleral, and hybrid designs.
Lenticular Designs
Lenticular designs reduce thickness in high Rx lenses:
- Plus lentic — thinned mid-periphery to reduce center thickness and mass in high-plus (aphakic) lenses
- Minus lentic — thinned edge zone to reduce edge thickness in high-minus lenses
Reducing thickness raises Dk/t, improves comfort, and reduces lid interaction — critical for high Rx patients who would otherwise suffer hypoxic and mechanical complications.
Design Selection Cheat Sheet
- Clinical Need First-Line Design
- ≤0.75 D astig, no presbyopia Spherical soft or SiHy
- ≥0.75 D astig Soft toric; RGP if irregular
- Early presbyopia Aspheric center-near multifocal
- Mature presbyopia, high add Translating bifocal or center-distance multifocal
- Irregular cornea, RGP intolerant Hybrid or scleral
- Severe dry eye Scleral (vaulted reservoir)
- Pediatric myopia control Ortho-K or distance-center multifocal soft
- Asymmetric ectasia Quadrant-specific scleral