Study guide
Water Content, Wetting Angle, Modulus, Silicone Hydrogel & Surface Treatments
NCLE CLRE Contact Lens Registry Exam Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
0.1 About the CLRE Exam 0.2 How to Use This Study Guide
2 Ocular Anatomy: Adnexa
Tear Film: Layers, Glands & Break-Up Time Conjunctiva, Lids, Lashes, Fornix & Canthi Blink Rate, Lid Function & Contact Lens Wear Effects
3 Ocular Anatomy: Anterior & Posterior Segment
Corneal Layers, Curvature, Topography & Metabolism Iris, Pupil, Sclera & Anterior Chamber Crystalline Lens, Retina, Choroid & Posterior Chamber
4 Refractive Errors & Contact Lens Optics
Myopia, Hyperopia, Astigmatism, Presbyopia & Anisometropia Refraction, Prism, Lacrimal Lens, Accommodation & Transposition Vertex Distance, Sagittal Depth & Spherical Equivalent
5 Measurement Instrumentation
Keratometer/Ophthalmometer: Calibration, Readings & Interpretation Corneal Topography & OCT for Contact Lens Fitting Schirmer Tests & Tear Break-Up Time
6 Observation & Verification Instrumentation
Slit Lamp (Biomicroscope) Operation & Illumination Slit Lamp Evaluation With & Without Contact Lenses Radiuscope, Lensometer, Thickness Gauge & ANSI Z80
7 Prefitting Patient Evaluation
6.1 Lifestyle, Occupation, Environment & Motivation 6.2 Medical History, Diseases, Medications & Allergies 6.3 Contraindications & Factors for Successful Wear 6.4 Relating Corneal Measurements, Rx & Lens Parameters
8 Lens Materials, Design & Parameter Selection
Dk, Dk/t, Thermal Conductivity & Holden-Mertz Water Content, Wetting Angle, Modulus, Silicone Hydrogel & Surface Treatments Toric, Multifocal, Aspheric, Hybrid, Scleral, Orthokeratology & Quadrant-Specific Base Curve, Peripheral Curves, Diameter, Thickness, Power & Edge Design
9 Diagnostic Fitting Procedures
8.1 Lens Selection & Application Procedures 8.2 Fluorescein Pattern Evaluation for RGP Lenses 8.3 Soft Lens Movement, Centration & Coverage
10 Fit Evaluation & Over-Refraction
Toric Lens Axis Rotation, LARS Rule & Stabilization Patient Comfort, Visual Acuity & Over-Refraction Modifying Base Curve, Diameter, Sag & Power from Findings
11 Dispensing: Wearing Schedules & Replacement
Daily, Flexible & Extended/Continuous Wear Schedules Daily, Biweekly, Monthly & Conventional Replacement Adaptation Protocols & Patient Compliance Counseling
12 Dispensing: Lens Care Systems
Solution Compatibility with Lens Types Chemical, Heat/UV, Hydrogen Peroxide & Neutralization Surfactant Cleaners, Protein Removers & Weekly Cleaning Solution Sensitivities, Incompatibilities & Adverse Reactions
13 Dispensing: Handling & Hygiene
12.1 Soft Lens Insertion & Removal Techniques 12.2 RGP Insertion, Removal & Emergency Responses 12.3 Hygiene, Soaps, Cosmetics & Storage Containers 12.4 Verifying Lens Parameters Against the Order at Dispensing
14 Follow-Up: Subjective & Objective Findings
13.1 Subjective Complaints: Dryness, Awareness, Blurry Vision, Pain & Photophobia 13.2 Steep vs Flat Lens Fit (Rigid & Soft) & Everted Lens 13.3 Injection, Edema, Discharge, Vision Loss & Lid Problems 13.4 Visual Acuity, Over-Refraction & Gross Evaluation Techniques
15 Follow-Up: Staining Patterns & Complications
14.1 Staining Patterns: 3 & 9 O'Clock, Foreign Body, SPK, Arcuate, Smile & Dimple Veiling 14.2 SEAL, CLARE, VLK, SLK & CLPU 14.3 Microbial Keratitis, Acanthamoeba, Dendritic Ulcer & Infiltrates 14.4 Corneal Molding/Warpage, Dellen & Mucin Balls
16 Follow-Up: Management Protocols
GPC, Blepharitis, Ptosis & Tarsal Plate Evaluation Daily Wear, Extended, Therapeutic, Postsurgical & Pathology Protocols Changing Lens Parameters at Follow-Up & Documenting Records
17 Regulatory & Administrative
FCLCA, FDA, FTC, Contact Lens Rule & Prescriber Verification HIPAA, PHI, OSHA, CDC, ANSI & Universal Precautions Record Retention, Inventory, Ordering & Documentation Methodology
Water Content, Wetting Angle, Modulus, Silicone Hydrogel & Surface Treatments
Key Takeaways Explain This Topic AI
Traditional hydrogels tie oxygen to water content; silicone hydrogels break that rule with high Dk at low water content.
High-water lenses dehydrate faster in low-humidity environments, shrinking and tightening on the eye — the classic dry-eye tight-lens problem.
Wetting angle below 90° is hydrophilic; modern surface-treated or wetting-agent SiHy achieves 20–60°, similar to traditional hydrogels.
Modulus (Young's modulus) drives mechanical interaction: first-gen SiHy ~1.2 MPa causes lid awareness and SEALs; low-modulus 3rd/4th-gen SiHy ~0.3–0.7 MPa is more comfortable.
SiHy surface strategies: plasma surface treatment, internal wetting agents (PVP/Hydraclear), and surface-coated water-gradient designs.
Last updated: July 2026
Water Content, Wetting Angle, Modulus, Silicone Hydrogel & Surface Treatments
Quick Answer: Traditional hydrogels tie oxygen to water content; silicone hydrogels break that rule with high Dk and low water. Modulus (stiffness) drives comfort and mechanical interaction. Surface treatments and internal wetting agents make the hydrophobic silicone backbone wearable.
Water Content
Water content is the percentage of water by weight in a fully hydrated lens. In traditional hydrogels, water is the oxygen carrier, so:
- Higher water content → higher Dk (in hydrogels only)
- Higher water content → faster dehydration in low-humidity environments
A 70% water lens on a dry eye or in an air-conditioned room loses water to the tear film and atmosphere. As it dehydrates, the lens shrinks, tightens on the eye , steepens the effective base curve, and reduces oxygen transmissibility — the classic "dry eye tight lens" problem. Patients with low tear break-up time (TBUT) or Sjögren syndrome should generally be fit with low-water or non-dehydrating SiHy.
Silicone hydrogels break the water/Dk relationship: a 24% water SiHy can have Dk 140, while a 70% water hydrogel caps out near Dk 40.
Water Content Range Example Materials Behavior
Low (24–38%) etafilcon A, polymacon, lotrafilcon A Stable on dry eye, lower Dk (hydrogel) or very high Dk (SiHy)
- Mid (45–55%) vifilcon A, hilafilcon B, comfilcon A Balanced
- High (60–78%) latocofilcon A, omafilcon A High Dk hydrogel, dehydrates faster
- Wetting Angle
The wetting angle (contact angle) measures how a water droplet spreads on the lens surface:
- Low angle (<90°) = hydrophilic = good wettability
- High angle (>90°) = hydrophobic = poor wettability
- Material Surface Wetting Angle (°)
- PMMA ~65–80
- Traditional hydrogel ~20–40
- SiHy (untreated silicone) ~100+
- SiHy (plasma-treated) ~40–60
- SiHy (HydroPEG / internal wetting) ~20–40
A lower wetting angle means the tear film spreads smoothly → better comfort, less deposit formation, less friction on blink. High wetting angles correlate with lipid/protein deposition and increased lid-plate friction.
Modulus (Material Stiffness)
Modulus = Young's modulus = how much a material resists deformation. Measured in megapascals (MPa) .
- Modulus (MPa) Class Clinical Behavior
- 0.3–0.5 Low-modulus SiHy (senofilcon A, delefilcon A) Very comfortable, fragile handling
- 0.7–1.2 First-gen SiHy (lotrafilcon A, balafilcon A) Stiffer, more mechanical awareness
- 0.3–0.6 Traditional hydrogel Soft, comfortable, lower Dk
High modulus (first-gen SiHy ~1.2 MPa):
- Easier to handle, more mechanically robust
- Better tear exchange and on-eye movement
More mechanical interaction: lid awareness, SEALs (superior epithelial arcuate lesions), papillary conjunctivitis, 3 and 9 o'clock staining
Low modulus (3rd/4th-gen SiHy):
- More comfortable initially
- More fragile, drapes more → less tear exchange
- Less mechanical staining, but may flex more on high Rx
- Silicone Hydrogel Classes & Surface Treatments
Silicone hydrogels use three main strategies to overcome the hydrophobic silicone surface:
Plasma surface treatment — gas plasma oxidizes the surface, creating a permanent hydrophilic layer. Examples: lotrafilcon A (plasma surface oxidation) and balafilcon A (plasma transformation). Surface is permanent but thin.
Internal wetting agents — a wetting molecule (PVP, Hydraclear, Hydraglyde, Aquaform) is incorporated into the polymer matrix, so the surface regenerates with each blink. Examples: senofilcon A, narafilcon A, comfilcon A .
Surface-coated — a separate hydrophilic coating is applied over a SiHy core. Example: delefilcon A (water-gradient lens with a ~2 µm hydrogel skin over a SiHy core, giving a near-hydrogel surface with SiHy Dk).
Non-surface-treated SiHy : materials where the surface chemistry is essentially the same as the bulk (no plasma, no separate coating) — wettability comes from internal wetting agents or inherently wettable silicone monomers. Comfilcon A is the classic example.
Comparison Table — Material Classes
- Class Example Dk Water Modulus (MPa) Surface Strategy
- 1st gen SiHy lotrafilcon A 140 24% 1.2 Plasma surface
- 1st gen SiHy balafilcon A 91 36% 1.1 Plasma surface
- 2nd gen SiHy senofilcon A 103 38% 0.7 Internal wetting (Hydraclear)
- 3rd gen SiHy comfilcon A 128 48% 0.75 Non-surface-treated (Aquaform)
- 4th gen SiHy delefilcon A 140 33% 0.6 Surface-coated (water gradient)
- Traditional hydrogel etafilcon A 28 58% 0.3–0.5 None (intrinsic hydrogel)
- PMMA — 0 0% >100 Wettable only by tear film
- Clinical Selection Logic
- Dry eye / low humidity → low-water SiHy or non-surface-treated SiHy to limit dehydration
- Mechanical sensitivity / SEALs history → low-modulus SiHy (3rd/4th gen)
- Deposit-prone patient → low wetting angle, surface-coated or plasma-treated
- Extended wear candidate → Dk ≥100 SiHy with a proven surface treatment and careful follow-up for infiltrates
Fragile handler (geriatric, tremor) → higher modulus SiHy is easier to insert; consider it despite mild comfort trade-off
Key Takeaways
Dk vs water content : only coupled in traditional hydrogels.
Wetting angle is the single best surface-comfort predictor.
Modulus drives mechanical complications more than comfort itself.
Surface strategy determines whether wettability survives the wearing cycle or degrades over 2–4 weeks.
Surface Treatment Comparison at a Glance
Surface Strategy Advantages Limitations Representative Material
Plasma surface treatment Permanent hydrophilic surface; stable wettability Thin layer, can be damaged by mechanical handling; high modulus lotrafilcon A, balafilcon A
Internal wetting agents (PVP/Hydraclear) Surface regenerates with each blink; comfortable, low modulus Wettability can decline over 2–4 weeks as wetting agent leaches senofilcon A, comfilcon A
Surface-coated (water gradient) Near-hydrogel surface comfort with SiHy core Dk Coating can delaminate with abrasive cleaners delefilcon A
Non-surface-treated No coating to wear off; consistent through wearing cycle Relies on bulk chemistry, slightly less wettable than coated comfilcon A (Aquaform)
Wetting Angle Measurement
The wetting angle is measured by the sessile drop method (a water droplet placed on the lens surface) or the captive bubble method (an air bubble under the lens in saline). The captive bubble method is more reproducible for soft lenses because the lens remains fully hydrated during measurement. Reported values vary by method, so always check which technique the manufacturer used when comparing materials.