Study guide
Schirmer Tests & Tear Break-Up Time
NCLE CLRE Contact Lens Registry Exam Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
0.1 About the CLRE Exam 0.2 How to Use This Study Guide
2 Ocular Anatomy: Adnexa
Tear Film: Layers, Glands & Break-Up Time Conjunctiva, Lids, Lashes, Fornix & Canthi Blink Rate, Lid Function & Contact Lens Wear Effects
3 Ocular Anatomy: Anterior & Posterior Segment
Corneal Layers, Curvature, Topography & Metabolism Iris, Pupil, Sclera & Anterior Chamber Crystalline Lens, Retina, Choroid & Posterior Chamber
4 Refractive Errors & Contact Lens Optics
Myopia, Hyperopia, Astigmatism, Presbyopia & Anisometropia Refraction, Prism, Lacrimal Lens, Accommodation & Transposition Vertex Distance, Sagittal Depth & Spherical Equivalent
5 Measurement Instrumentation
Keratometer/Ophthalmometer: Calibration, Readings & Interpretation Corneal Topography & OCT for Contact Lens Fitting Schirmer Tests & Tear Break-Up Time
6 Observation & Verification Instrumentation
Slit Lamp (Biomicroscope) Operation & Illumination Slit Lamp Evaluation With & Without Contact Lenses Radiuscope, Lensometer, Thickness Gauge & ANSI Z80
7 Prefitting Patient Evaluation
6.1 Lifestyle, Occupation, Environment & Motivation 6.2 Medical History, Diseases, Medications & Allergies 6.3 Contraindications & Factors for Successful Wear 6.4 Relating Corneal Measurements, Rx & Lens Parameters
8 Lens Materials, Design & Parameter Selection
Dk, Dk/t, Thermal Conductivity & Holden-Mertz Water Content, Wetting Angle, Modulus, Silicone Hydrogel & Surface Treatments Toric, Multifocal, Aspheric, Hybrid, Scleral, Orthokeratology & Quadrant-Specific Base Curve, Peripheral Curves, Diameter, Thickness, Power & Edge Design
9 Diagnostic Fitting Procedures
8.1 Lens Selection & Application Procedures 8.2 Fluorescein Pattern Evaluation for RGP Lenses 8.3 Soft Lens Movement, Centration & Coverage
10 Fit Evaluation & Over-Refraction
Toric Lens Axis Rotation, LARS Rule & Stabilization Patient Comfort, Visual Acuity & Over-Refraction Modifying Base Curve, Diameter, Sag & Power from Findings
11 Dispensing: Wearing Schedules & Replacement
Daily, Flexible & Extended/Continuous Wear Schedules Daily, Biweekly, Monthly & Conventional Replacement Adaptation Protocols & Patient Compliance Counseling
12 Dispensing: Lens Care Systems
Solution Compatibility with Lens Types Chemical, Heat/UV, Hydrogen Peroxide & Neutralization Surfactant Cleaners, Protein Removers & Weekly Cleaning Solution Sensitivities, Incompatibilities & Adverse Reactions
13 Dispensing: Handling & Hygiene
12.1 Soft Lens Insertion & Removal Techniques 12.2 RGP Insertion, Removal & Emergency Responses 12.3 Hygiene, Soaps, Cosmetics & Storage Containers 12.4 Verifying Lens Parameters Against the Order at Dispensing
14 Follow-Up: Subjective & Objective Findings
13.1 Subjective Complaints: Dryness, Awareness, Blurry Vision, Pain & Photophobia 13.2 Steep vs Flat Lens Fit (Rigid & Soft) & Everted Lens 13.3 Injection, Edema, Discharge, Vision Loss & Lid Problems 13.4 Visual Acuity, Over-Refraction & Gross Evaluation Techniques
15 Follow-Up: Staining Patterns & Complications
14.1 Staining Patterns: 3 & 9 O'Clock, Foreign Body, SPK, Arcuate, Smile & Dimple Veiling 14.2 SEAL, CLARE, VLK, SLK & CLPU 14.3 Microbial Keratitis, Acanthamoeba, Dendritic Ulcer & Infiltrates 14.4 Corneal Molding/Warpage, Dellen & Mucin Balls
16 Follow-Up: Management Protocols
GPC, Blepharitis, Ptosis & Tarsal Plate Evaluation Daily Wear, Extended, Therapeutic, Postsurgical & Pathology Protocols Changing Lens Parameters at Follow-Up & Documenting Records
17 Regulatory & Administrative
FCLCA, FDA, FTC, Contact Lens Rule & Prescriber Verification HIPAA, PHI, OSHA, CDC, ANSI & Universal Precautions Record Retention, Inventory, Ordering & Documentation Methodology
Schirmer Tests & Tear Break-Up Time
Key Takeaways Explain This Topic AI
Schirmer I (no anesthesia) measures basal plus reflex tearing; normal is >=10-15 mm wetting in 5 minutes and <10 mm suggests dry eye.
Schirmer II (with topical anesthesia) isolates basal secretion; <5 mm is abnormal and indicates aqueous-deficient dry eye.
Phenol red thread test is a 15-second, less irritating alternative; normal is >=10 mm wetting.
Tear break-up time (TBUT) measures tear film stability with fluorescein; normal is >=10 seconds and <10 seconds is unstable.
Low tear volume and unstable tear film drive CL intolerance, deposits, staining, and soft lens dehydration.
Last updated: July 2026
Schirmer Tests & Tear Break-Up Time
Quick Answer: Tear film testing determines whether a patient's tear volume and stability can support contact lens wear. Schirmer I (no anesthesia) measures basal plus reflex tearing — normal is >=10-15 mm of wetting in 5 minutes. Schirmer II (with anesthesia) isolates basal secretion; <5 mm is abnormal. The phenol red thread test is a faster, less irritating alternative. Tear break-up time (TBUT) measures tear film stability — normal is >=10 seconds, and <10 seconds indicates an unstable tear film that predicts contact lens intolerance, deposits, and staining.
Why Tear Film Testing Matters for CL
A contact lens floats on and within the tear film. Tear deficiency or instability causes:
Lens awareness and discomfort — the leading cause of CL drop-out.
Protein and lipid deposits — concentrated in poor tear films.
Corneal and conjunctival staining — exposure keratopathy and 3-9 staining.
Reduced wearing time and lens surface drying.
Soft lens dehydration — low tear volume draws water out of the lens.
Schirmer Test I (Without Anesthesia)
Purpose : measures basal + reflex tear secretion.
Procedure :
Dry the eye of excess tears with a cotton-tipped applicator.
Fold a standardized Whatman #41 filter paper strip (5 x 35 mm) at the notch.
Place the folded end in the lateral third of the lower conjunctival fornix (not the caruncle).
The patient closes the eyes gently for 5 minutes (or looks downward).
Remove the strip and measure wetting from the notch in millimeters.
Interpretation :
- Wetting (mm / 5 min) Interpretation
- >=15 Normal
- 10-14 Borderline
- 5-9 Mild-to-moderate dry eye
- <5 Severe dry eye
A normal result effectively rules out aqueous deficiency; a low result prompts further work-up such as Schirmer II, osmolarity, or MMP-9 testing.
Schirmer Test II (With Anesthesia)
Purpose : isolates basal secretion by blocking reflex tearing.
Procedure :
Instill a drop of topical anesthetic (proparacaine or tetracaine).
Blot the remaining tears and excess anesthetic from the lower fornix.
Place the filter strip as in Schirmer I.
Wait 5 minutes and measure.
Interpretation :
- >=10 mm normal basal secretion
- 5-9 mm mild basal deficiency
- <5 mm abnormal basal secretion — aqueous-deficient dry eye
Schirmer II helps distinguish aqueous-deficient dry eye (Sjögren's, lacrimal gland disease) from evaporative dry eye.
Phenol Red Thread Test
A less-stimulating alternative to Schirmer.
Use a cotton thread impregnated with phenol red (a pH indicator).
Place the folded end in the lateral lower fornix for 15 seconds .
Measure the wetted (red-colored) length in millimeters.
Normal : >=10 mm wetting per 15 seconds.
Abnormal : <6 mm.
Advantages: minimal reflex stimulation, faster, better tolerated — useful in sensitive patients and children.
Tear Break-Up Time (TBUT)
Purpose : evaluates tear film stability (not volume).
Procedure (fluorescein method) :
Instill a small amount of fluorescein (dye strip moistened with saline, or a fluoret).
Ask the patient to blink a few times, then hold the blink open.
Examine with the cobalt blue filter on the slit lamp (or use a TearScope for non-invasive TBUT).
Start a timer at the last complete blink.
Stop at the appearance of the first dry spot (dark area) in the tear film.
Interpretation :
- TBUT Interpretation
- >=10 sec Normal / stable
- 5-9 sec Marginal instability
- <5 sec Unstable tear film
A TBUT <10 seconds suggests meibomian gland dysfunction or mucin deficiency and predicts CL intolerance.
Other Tear Film Tests (Brief)
Tear osmolarity (>312 mOsm/L suggests dry eye; more specific than Schirmer).
MMP-9 (InflammaDry) — elevated in inflammatory dry eye.
Lipid layer evaluation (TearScope, interferometry) — assesses meibum quality.
Meibography — imaging of meibomian gland structure.
Rose Bengal / Lissamine Green staining — marks devitalized epithelial cells.
Applying Results to Contact Lens Fitting
- Finding CL Implication
- Schirmer I <10 mm Avoid extended wear; consider daily disposables; rule out dry eye disease first
- Schirmer II <5 mm Likely intolerant; refer for dry eye management before fitting
- TBUT <10 sec High risk of deposits and discomfort; favor silicone hydrogel with wetting agents
Phenol red thread <6 mm Similar to low Schirmer; consider punctal plugs or a low-water lens to limit dehydration
Note on lens water content : paradoxically, high-water-content lenses can dehydrate faster in dry eyes, drawing tears from an already low reservoir. A low-water, silicone hydrogel lens with a surface wetting agent often performs better than a high-water traditional hydrogel.
Worked Clinical Scenario
A 52-year-old CL candidate reports afternoon dryness and blur with her current soft lenses. Work-up shows:
Schirmer I (no anesthesia) : 8 mm / 5 min — borderline low, indicating reduced total tear secretion.
Schirmer II (with anesthesia) : 6 mm / 5 min — mild basal deficiency (still above the 5 mm severe cutoff).
TBUT : 6 seconds — unstable tear film; meibomian gland dysfunction suspected.
Phenol red thread : 8 mm / 15 sec — mildly reduced.
Interpretation: this is a mixed aqueous-deficient and evaporative dry eye . Plan: lid hygiene and warm compresses for meibomian gland dysfunction, switch to a daily disposable silicone hydrogel with surface wetting agents , avoid extended wear, consider punctal plugs if symptoms persist, and re-evaluate after 4-6 weeks of treatment before authorizing continued CL use. Documenting these numbers in the chart supports your medical decision-making and protects the fitting as evidence-based.
Documentation Tips
Record the test type, eye, time, and value (e.g., "Schirmer I OD 8 mm / 5 min without anesthesia").
Note anesthetic used for Schirmer II so the basal-only result is not mistaken for a Schirmer I value.
For TBUT, average three trials and record the mean; one short reading may be a blink artifact.
Compare to baseline at follow-up visits to demonstrate treatment response or progression.