Study guide
Slit Lamp Evaluation With & Without Contact Lenses
NCLE CLRE Contact Lens Registry Exam Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
0.1 About the CLRE Exam 0.2 How to Use This Study Guide
2 Ocular Anatomy: Adnexa
Tear Film: Layers, Glands & Break-Up Time Conjunctiva, Lids, Lashes, Fornix & Canthi Blink Rate, Lid Function & Contact Lens Wear Effects
3 Ocular Anatomy: Anterior & Posterior Segment
Corneal Layers, Curvature, Topography & Metabolism Iris, Pupil, Sclera & Anterior Chamber Crystalline Lens, Retina, Choroid & Posterior Chamber
4 Refractive Errors & Contact Lens Optics
Myopia, Hyperopia, Astigmatism, Presbyopia & Anisometropia Refraction, Prism, Lacrimal Lens, Accommodation & Transposition Vertex Distance, Sagittal Depth & Spherical Equivalent
5 Measurement Instrumentation
Keratometer/Ophthalmometer: Calibration, Readings & Interpretation Corneal Topography & OCT for Contact Lens Fitting Schirmer Tests & Tear Break-Up Time
6 Observation & Verification Instrumentation
Slit Lamp (Biomicroscope) Operation & Illumination Slit Lamp Evaluation With & Without Contact Lenses Radiuscope, Lensometer, Thickness Gauge & ANSI Z80
7 Prefitting Patient Evaluation
6.1 Lifestyle, Occupation, Environment & Motivation 6.2 Medical History, Diseases, Medications & Allergies 6.3 Contraindications & Factors for Successful Wear 6.4 Relating Corneal Measurements, Rx & Lens Parameters
8 Lens Materials, Design & Parameter Selection
Dk, Dk/t, Thermal Conductivity & Holden-Mertz Water Content, Wetting Angle, Modulus, Silicone Hydrogel & Surface Treatments Toric, Multifocal, Aspheric, Hybrid, Scleral, Orthokeratology & Quadrant-Specific Base Curve, Peripheral Curves, Diameter, Thickness, Power & Edge Design
9 Diagnostic Fitting Procedures
8.1 Lens Selection & Application Procedures 8.2 Fluorescein Pattern Evaluation for RGP Lenses 8.3 Soft Lens Movement, Centration & Coverage
10 Fit Evaluation & Over-Refraction
Toric Lens Axis Rotation, LARS Rule & Stabilization Patient Comfort, Visual Acuity & Over-Refraction Modifying Base Curve, Diameter, Sag & Power from Findings
11 Dispensing: Wearing Schedules & Replacement
Daily, Flexible & Extended/Continuous Wear Schedules Daily, Biweekly, Monthly & Conventional Replacement Adaptation Protocols & Patient Compliance Counseling
12 Dispensing: Lens Care Systems
Solution Compatibility with Lens Types Chemical, Heat/UV, Hydrogen Peroxide & Neutralization Surfactant Cleaners, Protein Removers & Weekly Cleaning Solution Sensitivities, Incompatibilities & Adverse Reactions
13 Dispensing: Handling & Hygiene
12.1 Soft Lens Insertion & Removal Techniques 12.2 RGP Insertion, Removal & Emergency Responses 12.3 Hygiene, Soaps, Cosmetics & Storage Containers 12.4 Verifying Lens Parameters Against the Order at Dispensing
14 Follow-Up: Subjective & Objective Findings
13.1 Subjective Complaints: Dryness, Awareness, Blurry Vision, Pain & Photophobia 13.2 Steep vs Flat Lens Fit (Rigid & Soft) & Everted Lens 13.3 Injection, Edema, Discharge, Vision Loss & Lid Problems 13.4 Visual Acuity, Over-Refraction & Gross Evaluation Techniques
15 Follow-Up: Staining Patterns & Complications
14.1 Staining Patterns: 3 & 9 O'Clock, Foreign Body, SPK, Arcuate, Smile & Dimple Veiling 14.2 SEAL, CLARE, VLK, SLK & CLPU 14.3 Microbial Keratitis, Acanthamoeba, Dendritic Ulcer & Infiltrates 14.4 Corneal Molding/Warpage, Dellen & Mucin Balls
16 Follow-Up: Management Protocols
GPC, Blepharitis, Ptosis & Tarsal Plate Evaluation Daily Wear, Extended, Therapeutic, Postsurgical & Pathology Protocols Changing Lens Parameters at Follow-Up & Documenting Records
17 Regulatory & Administrative
FCLCA, FDA, FTC, Contact Lens Rule & Prescriber Verification HIPAA, PHI, OSHA, CDC, ANSI & Universal Precautions Record Retention, Inventory, Ordering & Documentation Methodology
Slit Lamp Evaluation With & Without Contact Lenses
Key Takeaways Explain This Topic AI
Without-lens evaluation proceeds tissue by tissue: lids, conjunctiva (with upper lid eversion to find GPC/papillae), cornea, and tear film; fluorescein staining reveals pattern-specific causes (SPK, 3 & 9 o'clock, foreign body track).
RGP fit patterns are interpreted with fluorescein and cobalt blue: apical touch is dark central (flat fit), apical clearance is bright central pool (steep fit), alignment is a uniform thin layer, and edge lift shows as a peripheral band.
Soft lenses do not produce a usable fluorescein fit pattern; fluorescein is used to detect corneal staining under or around the lens after the lens is removed, because soft materials absorb fluorescein.
Soft lens fit is judged by coverage, movement (~0.5-1.5 mm/blink), centration, lid interaction, and edge behavior in white light, not by a fluorescein pattern.
Lens surface evaluation covers deposits (protein, lipid, inorganic, microbial), wettability, coating, and physical defects such as scratches, nicks, and cracks.
Last updated: July 2026
Slit Lamp Evaluation With & Without Contact Lenses
A CLRE slit-lamp evaluation happens in two phases: the without-lens ocular health exam and the with-lens fit and surface exam. Both use the same instrument, but each has its own sequence, staining strategy, and pattern vocabulary. Domain III treats pattern recognition as testable material, so the candidate must connect a clinical picture to a structural cause, not just name it.
Phase 1: Without Contact Lenses
Before any lens is placed, the slit lamp must clear the eye for contact lens wear. Work tissue by tissue:
Tissue What to check Technique
Lids & lashes Blepharitis, lid wiper, Meibomian gland orifice plugging, lash misdirection Diffuse beam, low magnification; express Meibomian glands
Conjunctiva (bulbar) Injection, chemosis, pinguecula, pterygium Diffuse, broad beam
Conjunctiva (tarsal) Papillae, follicles, giant papillary conjunctivitis (GPC) Evert the upper lid — large papillae hide here
Cornea Staining, edema, infiltrates, vascularization (pannus) Direct focal optical section + cobalt blue after fluorescein
- Tear film Meniscus height, debris, lipid layer, TBUT Tangential / broad beam; fluorescein for TBUT
- Staining Patterns and Meaning
Fluorescein staining indicates compromised epithelium. Recognizing the pattern's location and shape points to a cause:
Punctate staining (SPK) — fine, dotted, diffuse; often dry eye, solution toxicity, or mild mechanical trauma.
3 & 9 o'clock staining — staining at the 3 and 9 o'clock positions of the cornea; classic for RGP wearers due to poor tear exchange and lid interaction at those positions; often improved with edge design changes.
Foreign body staining — linear or arcuate tracks from a foreign body under the lens or lid; tracks follow the path of the offending particle.
Inferior arcuate staining — often soft lens-related, due to lens dehydration or interaction with the inferior lid margin.
Dimple veiling — punctate staining from mechanical compression (often from overnight wear or a steep lens).
Central corneal staining — possible tight lens syndrome, solution toxicity, or epithelial hypoxia.
Phase 2: With Contact Lenses
Once ocular health is confirmed, the fit and surface of the lens are evaluated on the eye .
RGP Lenses with Fluorescein
Fluorescein is essential for evaluating RGP fit patterns. Instill a small amount of fluorescein and observe with cobalt blue:
Pattern Fluorescein appearance Interpretation
Apical touch Dark central area (no fluorescein between lens and cornea) Flat fit; cornea bears on lens back surface
Apical clearance Bright central pool of fluorescein Steep fit; excessive tear lens centrally
Alignment Thin, uniform fluorescein layer across the central cornea Ideal fit — base curve matches corneal curvature
Midperipheral bearing Dark zone in the midperiphery with central clearance Peripheral curve too steep or excessive central clearance
Excessive edge lift Wide bright band at the lens edge Edge stands off too far — risk of air bubbles and decentration
Insufficient edge lift No fluorescein band at the edge Edge too tight — reduced tear exchange, 3 & 9 staining risk
- Air bubbles Dark round voids, often peripherally Excessive edge lift or trapped bubbles under a steep lens
- Soft Lens Evaluation
Soft lenses do not require fluorescein for fit pattern — the lens drapes over the cornea and a fluorescein pattern is not visible. However, fluorescein is useful to:
Detect corneal staining under or around a soft lens (remove the lens to evaluate properly, since the lens may absorb fluorescein).
Confirm lens fit indirectly — excessive movement, edge lift, or conjunctival interaction may show as staining patterns after lens removal.
Soft lens fit evaluation on the eye uses white light and observation of:
Coverage — lens should cover the entire cornea, ideally 0.5-1.0 mm beyond the limbus.
Movement — ~0.5-1.5 mm with the blink; too little = tight; too much = loose.
Centration — ideally centered; temporal or nasal decentration suggests base curve or diameter mismatch.
Lid interaction — lens should not ride under the upper lid excessively (causes discomfort and upper lid staining).
Edge — should not compress conjunctiva (causes vascular blanching) or stand off (causes awareness and debris entry).
Lens Surface Evaluation
The lens surface is examined at low and medium magnification with diffuse illumination and direct focal beam:
Deposits — protein (white/opaque film), lipid (oily, glistening), inorganic (calcium, colored), and microbial (colonies, fungal filaments).
Wettability — poor wetting shows as dry spots on the lens surface; tear film breaks over the lens quickly.
Coating — visible film indicates cleaning or replacement interval problem.
Scratches, nicks, cracks — visible defects indicating handling damage or material fatigue.
For RGP surfaces, fogging or poor wetting often responds to in-office cleaning (surfactant, enzymatic, or solvent); scratches require polishing or replacement.
Common Traps
Forgetting to evert the upper lid — GPC's large papillae are not visible without eversion.
Evaluating a soft lens FIT with fluorescein — soft lens draping does not produce a usable fluorescein pattern.
Misreading apical touch vs clearance — touch is dark (lens touches cornea), clearance is bright (pool of tears).
Assessing soft lens staining with the lens on — fluorescein absorbs into soft materials, so the lens must be removed before evaluating corneal staining.
Missing 3 & 9 o'clock staining — it is almost pathognomonic for RGP-related tear exchange issues.
Sequence Checklist
A complete CL slit-lamp evaluation, in order:
Without lens: lids, then conjunctiva (evert upper lid), then cornea, then tear film.
Without lens: fluorescein for TBUT and baseline staining.
Insert lens: evaluate surface (deposits, wetting).
With lens: movement, centration, coverage (soft) or fluorescein pattern (RGP).
After lens removal: corneal staining pattern, conjunctival staining, lid wiper.