Crystalline Lens, Retina, Choroid & Posterior Chamber

NCLE CLRE Contact Lens Registry Exam Study Guide Exam

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Exam Overview

0.1 About the CLRE Exam 0.2 How to Use This Study Guide

2 Ocular Anatomy: Adnexa

Tear Film: Layers, Glands & Break-Up Time Conjunctiva, Lids, Lashes, Fornix & Canthi Blink Rate, Lid Function & Contact Lens Wear Effects

3 Ocular Anatomy: Anterior & Posterior Segment

Corneal Layers, Curvature, Topography & Metabolism Iris, Pupil, Sclera & Anterior Chamber Crystalline Lens, Retina, Choroid & Posterior Chamber

4 Refractive Errors & Contact Lens Optics

Myopia, Hyperopia, Astigmatism, Presbyopia & Anisometropia Refraction, Prism, Lacrimal Lens, Accommodation & Transposition Vertex Distance, Sagittal Depth & Spherical Equivalent

5 Measurement Instrumentation

Keratometer/Ophthalmometer: Calibration, Readings & Interpretation Corneal Topography & OCT for Contact Lens Fitting Schirmer Tests & Tear Break-Up Time

6 Observation & Verification Instrumentation

Slit Lamp (Biomicroscope) Operation & Illumination Slit Lamp Evaluation With & Without Contact Lenses Radiuscope, Lensometer, Thickness Gauge & ANSI Z80

7 Prefitting Patient Evaluation

6.1 Lifestyle, Occupation, Environment & Motivation 6.2 Medical History, Diseases, Medications & Allergies 6.3 Contraindications & Factors for Successful Wear 6.4 Relating Corneal Measurements, Rx & Lens Parameters

8 Lens Materials, Design & Parameter Selection

Dk, Dk/t, Thermal Conductivity & Holden-Mertz Water Content, Wetting Angle, Modulus, Silicone Hydrogel & Surface Treatments Toric, Multifocal, Aspheric, Hybrid, Scleral, Orthokeratology & Quadrant-Specific Base Curve, Peripheral Curves, Diameter, Thickness, Power & Edge Design

9 Diagnostic Fitting Procedures

8.1 Lens Selection & Application Procedures 8.2 Fluorescein Pattern Evaluation for RGP Lenses 8.3 Soft Lens Movement, Centration & Coverage

10 Fit Evaluation & Over-Refraction

Toric Lens Axis Rotation, LARS Rule & Stabilization Patient Comfort, Visual Acuity & Over-Refraction Modifying Base Curve, Diameter, Sag & Power from Findings

11 Dispensing: Wearing Schedules & Replacement

Daily, Flexible & Extended/Continuous Wear Schedules Daily, Biweekly, Monthly & Conventional Replacement Adaptation Protocols & Patient Compliance Counseling

12 Dispensing: Lens Care Systems

Solution Compatibility with Lens Types Chemical, Heat/UV, Hydrogen Peroxide & Neutralization Surfactant Cleaners, Protein Removers & Weekly Cleaning Solution Sensitivities, Incompatibilities & Adverse Reactions

13 Dispensing: Handling & Hygiene

12.1 Soft Lens Insertion & Removal Techniques 12.2 RGP Insertion, Removal & Emergency Responses 12.3 Hygiene, Soaps, Cosmetics & Storage Containers 12.4 Verifying Lens Parameters Against the Order at Dispensing

14 Follow-Up: Subjective & Objective Findings

13.1 Subjective Complaints: Dryness, Awareness, Blurry Vision, Pain & Photophobia 13.2 Steep vs Flat Lens Fit (Rigid & Soft) & Everted Lens 13.3 Injection, Edema, Discharge, Vision Loss & Lid Problems 13.4 Visual Acuity, Over-Refraction & Gross Evaluation Techniques

15 Follow-Up: Staining Patterns & Complications

14.1 Staining Patterns: 3 & 9 O'Clock, Foreign Body, SPK, Arcuate, Smile & Dimple Veiling 14.2 SEAL, CLARE, VLK, SLK & CLPU 14.3 Microbial Keratitis, Acanthamoeba, Dendritic Ulcer & Infiltrates 14.4 Corneal Molding/Warpage, Dellen & Mucin Balls

16 Follow-Up: Management Protocols

GPC, Blepharitis, Ptosis & Tarsal Plate Evaluation Daily Wear, Extended, Therapeutic, Postsurgical & Pathology Protocols Changing Lens Parameters at Follow-Up & Documenting Records

17 Regulatory & Administrative

FCLCA, FDA, FTC, Contact Lens Rule & Prescriber Verification HIPAA, PHI, OSHA, CDC, ANSI & Universal Precautions Record Retention, Inventory, Ordering & Documentation Methodology

Crystalline Lens, Retina, Choroid & Posterior Chamber

Key Takeaways Explain This Topic AI

The crystalline lens contributes ~+19.00 D of refractive power and is the organ of accommodation, with presbyopia beginning in the early 40s

Aphakia requires ~+10 to +14 D of plus correction; aphakic contact lenses reduce image magnification to ~7% versus ~25% with spectacles, minimizing aniseikonia

The fovea contains cones only and supports 20/20 acuity; macular disease limits the acuity any contact lens can achieve

The choroid supplies the outer third of the retina through the choriocapillaris; choroidal disease reduces visual potential

Diabetes affects cornea (reduced sensitivity, delayed healing), lens (osmotic cataract), and retina (diabetic retinopathy), requiring high-Dk/t lenses and shorter wearing schedules

Last updated: July 2026

Crystalline Lens, Retina, Choroid & Posterior Chamber

Quick Answer: The posterior segment houses the crystalline lens (the eye's ~+19.00 D accommodation mechanism), the retina (which contains the macula, fovea, and the photoreceptors that define visual acuity), the choroid (the vascular supply to the outer retina), and the posterior chamber (the aqueous-filled space behind the iris). Posterior segment disease—cataract, pseudophakia, aphakia, diabetic retinopathy, macular degeneration—changes what a contact lens can and cannot achieve for a given patient.

Although contact lenses rest on the anterior segment, the CLRE candidate must understand posterior segment anatomy and pathology because best-corrected acuity with a contact lens cannot exceed the retinal potential . A perfectly fit lens on a diseased retina yields disappointing acuity, and some posterior conditions (aphakia, aniseikonia, pseudophakic anisometropia) are direct contact lens indications.

Crystalline Lens

The crystalline lens is a biconvex, avascular structure suspended behind the iris by the zonules of Zinn (attached to the ciliary body). It contributes ~+19.00 D to the eye's total ~+60.00 D and is the organ of accommodation.

  • Structure Description
  • Capsule Acellular basement membrane of the lens epithelium
  • Epithelium Single layer beneath anterior capsule; produces new lens fibers
  • Cortex Outer fiber mass
  • Nucleus Central, oldest, densest fibers (embryonic, fetal, infantile, adult nuclei)

Accommodation : ciliary muscle contracts → zonules relax → lens assumes a more spherical shape → anterior surface curvature increases → power increases. Presbyopia (loss of accommodation) begins in the early 40s; multifocal and bifocal contact lenses are designed around this mechanism.

Cataract, Pseudophakia, and Aphakia

Cataract — any opacity of the crystalline lens. Visual impact depends on type (nuclear sclerotic, cortical, posterior subcapsular). Contact lens fitting is generally deferred until cataract surgery is complete because refractive error will change.

Pseudophakia — status post cataract extraction with intraocular lens (IOL) implantation. The IOL is usually monofocal; residual refractive error can be corrected with contact lenses. Anisometropia between eyes (different IOL powers, different axial lengths) is a classic contact lens indication to avoid image-size disparity (aniseikonia) that spectacles would produce.

Aphakia — no crystalline lens and no IOL. Aphakic eyes are extremely hyperopic (~+10 to +14 D). An aphakic contact lens is the optical correction of choice when secondary IOL implantation is contraindicated (e.g., pediatric traumatic cataract, capsule compromise). Spectacles create ~25% image magnification and significant aniseikonia; contact lenses produce ~7% magnification—much better tolerated.

Retina

The retina is the neurosensory tissue lining the posterior two-thirds of the eye. It converts light into neural signals carried by the optic nerve.

  • Structure Function
  • Macula ~5.5 mm diameter; central retina; responsible for fine detail and color
  • Fovea ~1.5 mm depression at macular center; cones only; no overlying ganglion cells
  • Foveola ~0.35 mm; thinnest retina; highest cone density; serves 20/20 acuity
  • Optic disc Cup/disc ratio ~0.3; site of optic nerve exit; blind spot
  • Peripheral retina Rod-dominant; motion and low-light detection

Rods — ~120 million; peak density 20° from fovea; contain rhodopsin; scotopic vision; high sensitivity, low acuity. Cones — ~6 million; concentrated at the fovea; three pigments (long-, medium-, short-wavelength); photopic vision; high acuity, color perception.

Retinal Abnormalities Relevant to Contact Lens Candidacy

Diabetic retinopathy — microvascular disease causing macular edema, hemorrhages, neovascularization. Diabetic patients also have reduced corneal sensitivity and delayed epithelial healing , which raises the risk of neurotrophic ulcers with contact lens wear. Fitting requires high-Dk/t materials and shorter wearing schedules.

Age-related macular degeneration (AMD) — central visual loss; reduced acuity expectations with contact lenses. Multifocal CLs may be unsuitable; distance single-vision CLs plus reading glasses over them are often better.

Retinal detachment / retinoschisis — surgical repair (scleral buckle, vitrectomy) changes axial length and astigmatism; refit contact lenses postoperatively after refractive stability (~3 months).

Retinitis pigmentosa — progressive rod dysfunction; constricted visual fields; photophobia. High-water-content lenses may improve comfort from reduced tear production.

Choroid

The choroid is the highly vascular layer between the retina and the sclera. It supplies oxygen and nutrients to the outer third of the retina (photoreceptors), which the retinal circulation does not reach.

  • Choriocapillaris — single layer of capillaries; densest near the fovea
  • Sattler's layer — medium vessels
  • Haller's layer — large outer vessels
  • Bruch's membrane — acellular layer between choroid and retinal pigment epithelium (RPE)

Choroidal pathology (choroidal neovascular membrane, central serous chorioretinopathy) reduces visual potential and therefore limits what contact lens correction can achieve. Choroidal melanoma is the most common primary intraocular malignancy in adults and is unrelated to contact lens wear but may be discovered on dilated exam prior to fitting.

Posterior Chamber

The posterior chamber is the small, aqueous-filled space between the iris and the lens zonules (anatomic posterior chamber, distinct from the vitreous-containing posterior segment). Aqueous humor produced by the ciliary body epithelium flows from here through the pupil into the anterior chamber.

Diabetes: The Cross-Segment Condition

Diabetes deserves special emphasis because it affects both segments:

  • Cornea — reduced sensitivity, delayed epithelial healing, punctate keratopathy
  • Retina — diabetic retinopathy, macular edema, neovascularization
  • Lens — osmotic cataract ("snowflake" cataract) from sorbitol accumulation during hyperglycemia

Fitting diabetics requires:

  • High-Dk/t silicone hydrogel or scleral lenses
  • Daily wear or daily disposable modalities when possible
  • Close monitoring for epithelial defects and infiltrates
  • Co-management with the patient's retinal specialist
  • Refraction when glucose is stable (refractive fluctuation can be ±0.50 D or more with glucose swings)
  • Key Takeaways for the CLRE

The crystalline lens contributes ~+19.00 D; aphakia requires ~+10 to +14 D of plus power—contact lenses minimize aniseikonia versus spectacles.

The fovea contains cones only; macular disease limits contact lens acuity expectations.

The choroid supplies the outer retina; choroidal disease reduces visual potential.

Diabetic patients need higher-Dk/t lenses, shorter wearing schedules, and co-management.

Pseudophakic anisometropia is a classic contact lens indication to avoid spectacle-induced aniseikonia.

Additional CL-Related Pathology High-Yield Items

Several Domain I pathology items span anterior and posterior findings and appear on both anatomy and follow-up questions:

Bullous keratopathy — endothelial failure with epithelial bullae and pain. Soft bandage lenses may be used therapeutically for comfort under medical direction; elective cosmetic/EW soft wear is generally contraindicated until the cornea is managed.

Media opacities — any opacity in the optical pathway (cornea, aqueous, lens/cataract, vitreous) that reduces best-corrected acuity. Contact lenses cannot improve acuity beyond the retinal/media limit; document acuity potential before promising CL outcomes.

Motility problems — disorders of lid/eye position such as entropion, ectropion, and strabismus . Entropion/ectropion alter lid/lens interaction and staining risk; large-angle strabismus can complicate binocular CL goals and prism needs. Flag lid malpositions before fitting.