1 Introduction & Exam Overview

0.1 About the CLRE Exam 0.2 How to Use This Study Guide

2 Ocular Anatomy: Adnexa

Tear Film: Layers, Glands & Break-Up Time Conjunctiva, Lids, Lashes, Fornix & Canthi Blink Rate, Lid Function & Contact Lens Wear Effects

3 Ocular Anatomy: Anterior & Posterior Segment

Corneal Layers, Curvature, Topography & Metabolism Iris, Pupil, Sclera & Anterior Chamber Crystalline Lens, Retina, Choroid & Posterior Chamber

4 Refractive Errors & Contact Lens Optics

Myopia, Hyperopia, Astigmatism, Presbyopia & Anisometropia Refraction, Prism, Lacrimal Lens, Accommodation & Transposition Vertex Distance, Sagittal Depth & Spherical Equivalent

5 Measurement Instrumentation

Keratometer/Ophthalmometer: Calibration, Readings & Interpretation Corneal Topography & OCT for Contact Lens Fitting Schirmer Tests & Tear Break-Up Time

6 Observation & Verification Instrumentation

Slit Lamp (Biomicroscope) Operation & Illumination Slit Lamp Evaluation With & Without Contact Lenses Radiuscope, Lensometer, Thickness Gauge & ANSI Z80

7 Prefitting Patient Evaluation

6.1 Lifestyle, Occupation, Environment & Motivation 6.2 Medical History, Diseases, Medications & Allergies 6.3 Contraindications & Factors for Successful Wear 6.4 Relating Corneal Measurements, Rx & Lens Parameters

8 Lens Materials, Design & Parameter Selection

Dk, Dk/t, Thermal Conductivity & Holden-Mertz Water Content, Wetting Angle, Modulus, Silicone Hydrogel & Surface Treatments Toric, Multifocal, Aspheric, Hybrid, Scleral, Orthokeratology & Quadrant-Specific Base Curve, Peripheral Curves, Diameter, Thickness, Power & Edge Design

9 Diagnostic Fitting Procedures

8.1 Lens Selection & Application Procedures 8.2 Fluorescein Pattern Evaluation for RGP Lenses 8.3 Soft Lens Movement, Centration & Coverage

10 Fit Evaluation & Over-Refraction

Toric Lens Axis Rotation, LARS Rule & Stabilization Patient Comfort, Visual Acuity & Over-Refraction Modifying Base Curve, Diameter, Sag & Power from Findings

11 Dispensing: Wearing Schedules & Replacement

Daily, Flexible & Extended/Continuous Wear Schedules Daily, Biweekly, Monthly & Conventional Replacement Adaptation Protocols & Patient Compliance Counseling

12 Dispensing: Lens Care Systems

Solution Compatibility with Lens Types Chemical, Heat/UV, Hydrogen Peroxide & Neutralization Surfactant Cleaners, Protein Removers & Weekly Cleaning Solution Sensitivities, Incompatibilities & Adverse Reactions

13 Dispensing: Handling & Hygiene

12.1 Soft Lens Insertion & Removal Techniques 12.2 RGP Insertion, Removal & Emergency Responses 12.3 Hygiene, Soaps, Cosmetics & Storage Containers 12.4 Verifying Lens Parameters Against the Order at Dispensing

14 Follow-Up: Subjective & Objective Findings

13.1 Subjective Complaints: Dryness, Awareness, Blurry Vision, Pain & Photophobia 13.2 Steep vs Flat Lens Fit (Rigid & Soft) & Everted Lens 13.3 Injection, Edema, Discharge, Vision Loss & Lid Problems 13.4 Visual Acuity, Over-Refraction & Gross Evaluation Techniques

15 Follow-Up: Staining Patterns & Complications

14.1 Staining Patterns: 3 & 9 O'Clock, Foreign Body, SPK, Arcuate, Smile & Dimple Veiling 14.2 SEAL, CLARE, VLK, SLK & CLPU 14.3 Microbial Keratitis, Acanthamoeba, Dendritic Ulcer & Infiltrates 14.4 Corneal Molding/Warpage, Dellen & Mucin Balls

16 Follow-Up: Management Protocols

GPC, Blepharitis, Ptosis & Tarsal Plate Evaluation Daily Wear, Extended, Therapeutic, Postsurgical & Pathology Protocols Changing Lens Parameters at Follow-Up & Documenting Records

17 Regulatory & Administrative

FCLCA, FDA, FTC, Contact Lens Rule & Prescriber Verification HIPAA, PHI, OSHA, CDC, ANSI & Universal Precautions Record Retention, Inventory, Ordering & Documentation Methodology

6.4 Relating Corneal Measurements, Rx & Lens Parameters

Key Takeaways Explain This Topic AI

Keratometry (K) readings and corneal topography provide the central corneal curvature data that inform lens base curve selection; the average normal K is approximately 43.00-44.00 D (7.5-7.8 mm radius)

For soft lenses, the base curve is typically selected 0.8-1.2 mm flatter than the flat K (or based on average K) to allow sagittal vaulting; for RGP lenses the fitting philosophy (on-K, steeper-than-flat-K, or flatter-than-flat-K) determines the base curve

Prescription drives lens type: spherical soft for low astigmatism ≤0.75 D, toric soft for ≥0.75 D cylinder, RGP for irregular cornea, scleral for keratoconus or severe irregularity, hybrid for irregular cornea with soft-lens comfort

Scleral lenses vault the cornea and rest on the conjunctiva/sclera; they are the modality of choice for keratoconus, post-corneal transplant, and severe ocular surface disease

A decision flowchart integrating K readings, prescription, slit-lamp findings, and lifestyle guides modality selection from spherical soft through toric, RGP, hybrid, and scleral

Last updated: July 2026

6.4 Relating Corneal Measurements, Rx & Lens Parameters

Quick Answer: The contact lens fitter integrates three data streams — corneal curvature (K readings or topography), patient prescription (sphere, cylinder, axis, add), and slit-lamp findings (lid tone, tear film, corneal integrity) — to choose a lens modality and parameters. Soft lens base curves are typically 0.8-1.2 mm flatter than the flat K (or based on average K). RGP base curves follow an on-K, steeper-than-flat-K, or flatter-than-flat-K fitting philosophy. Spherical soft lenses are used for low astigmatism ≤0.75 D, toric soft for ≥0.75 D cylinder, RGP for irregular corneas, and scleral lenses for keratoconus or severe irregularity.

The Three Data Streams

  • Data Stream Source What It Tells You
  • Corneal curvature Keratometry (K), topography, tomography Base curve, lens diameter, modality

Prescription (Rx) Refraction (sphere, cylinder, axis, add) Lens power, lens type (spherical, toric, multifocal)

Ocular surface & lids Slit-lamp, TBUT, Schirmer, lid evaluation Material, wearing schedule, modality tolerability

Keratometry Refresher

A keratometer measures the central ~3 mm of the cornea and reports curvature in diopters (D) of the steep and flat meridians. To convert diopters to radius of curvature in millimeters, use the formula:

r (mm) = 337.5 / K (D)

A K of 43.00 D corresponds to a radius of 7.85 mm. The normal cornea is approximately 43.00-44.00 D (7.67-7.85 mm radius), with the flat meridian typically horizontal and the steep vertical (with-the-rule astigmatism).

Soft Lens Base Curve Selection

Soft lenses drape over the cornea and rely on sagittal (sag) depth for centration and movement. Two common fitting rules:

Flatter-than-flat-K rule : choose a base curve 0.8-1.2 mm flatter than the flat K (in mm radius). If flat K is 7.80 mm, choose a base curve of 8.4-8.6 mm.

Average-K rule : average the flat and steep K readings (in mm radius) and select the closest standard base curve (often 8.4 or 8.6 mm).

A soft lens that is too steep binds, limits movement, and causes mechanical staining and neovascularization. A soft lens that is too flat moves excessively, decenteres, causes discomfort, and fluctuates vision — especially in toric designs.

RGP Base Curve Selection — Fitting Philosophies

RGP lenses interact with the tear lens to neutralize corneal astigmatism and irregularity. The base curve is selected by philosophy:

  • Philosophy Base Curve vs. Flat K Tear Lens Best For
  • On-K Equal to flat K Plano (no power adjustment) Spherical corneas, simple fits
  • Steeper-than-flat-K 0.25-0.50 D steeper Plus tear lens; add + power to lens Steep corneas, higher lid tension

Flatter-than-flat-K 0.25-0.50 D flatter Minus tear lens; add - power to lens Flat corneas, against-the-rule astigmatism

The tear lens is the fluid layer between the RGP and cornea. Its power equals the difference between the corneal curvature and the lens base curve. The final lens power equals the ocular refraction minus the tear lens power:

Lens Power = Ocular Rx - Tear Lens Power

This relationship is a high-yield exam concept. If the flat K is 43.00 D and you fit on-K (base curve 43.00 D), the tear lens is plano and the lens power equals the ocular Rx. If you fit 0.50 D steeper (base curve 43.50 D), the tear lens is +0.50 D and you must subtract +0.50 D from the ocular Rx to obtain the lens power.

Prescription and Lens Type Selection

  • Prescription Pattern Recommended Lens Type
  • Sphere only, no astigmatism Spherical soft lens
  • Astigmatism ≤0.75 D Spherical soft (cylinder often masked by tear lens in soft, or fit spherical equivalent)
  • Astigmatism ≥0.75 D Soft toric lens
  • Astigmatism ≥2.00 D Consider RGP or scleral for crisper optics
  • Irregular astigmatism (keratoconus, post-PK, post-LASIK ectasia, scar) RGP, hybrid, or scleral
  • Keratoconus (moderate to advanced) Scleral lens first-line; RGP or hybrid if centered
  • Presbyopia Multifocal soft, multifocal RGP/scleral, or monovision
  • Aphakia High-plus soft or RGP; often pediatric
  • Anisometropia >3 D Contact lens to avoid image-size disparity
  • Soft vs. RGP vs. Scleral vs. Hybrid — Decision Criteria
  • Soft Lenses

Best for : low-to-moderate astigmatism, cosmetic motivation, comfort-sensitive patients, sports, first-time wearers

  • Limit : masks only small corneal irregularity; oxygen transmission limited by material
  • RGP Lenses

Best for : irregular corneas (early keratoconus, post-LASIK, post-PK, scar), high astigmatism, presbyopia (multifocal RGP), patients wanting crisp optics

  • Limit : adaptation period (1-4 weeks), dislocation risk, debris under lens, comfort
  • Scleral Lenses

Best for : moderate-to-advanced keratoconus, post-corneal transplant, corneal ectasia, severe ocular surface disease (Stevens-Johnson, ocular cicatricial pemphigoid), high irregular astigmatism, exposure keratopathy

  • Mechanism : vaults the cornea entirely; lands on the conjunctiva/sclera; fluid reservoir bathes the cornea
  • Limit : insertion/removal learning curve, midday fogging, higher cost, longer chair time
  • Hybrid Lenses

Best for : irregular cornea patients who want RGP optics with soft-lens comfort; early keratoconus; post-LASIK ectasia

Limit : limited parameter range; higher cost; Dk limits; can induce neovascularization at the skirt

Decision Flowchart — Modality Selection Step 1: Is there an absolute contraindication?

  • YES → Defer fitting; treat; re-evaluate
  • NO → Continue

Step 2: Is the cornea irregular (keratoconus, post-PK, post-LASIK ectasia, scar)?

  • YES → Step 2a
  • NO → Step 3

Step 2a: How advanced is the irregularity?

  • Mild / central → RGP or hybrid
  • Moderate / advanced → Scleral lens (first-line)
  • Eccentric / advanced → Scleral lens

Step 3: What is the magnitude of astigmatism?

  • ≤0.75 D → Spherical soft lens
  • 0.75-2.00 D → Soft toric lens
  • ≥2.00 D → Soft toric, RGP, or scleral based on lifestyle and slit-lamp

Step 4: Is the patient presbyopic?

  • YES → Multifocal soft / monovision / multifocal RGP / scleral multifocal
  • NO → Continue
  • Step 5: Match base curve to K readings
  • Soft → 0.8-1.2 mm flatter than flat K (or average K rule)
  • RGP → on-K / steeper / flatter by philosophy; calculate tear lens power
  • Scleral → sagittal depth based on sag; not K-driven
  • Step 6: Confirm with slit-lamp and over-refraction at dispensing
  • Worked Example: Soft Toric Fit

A 28-year-old patient has K readings of 43.00 / 44.50 D and a refraction of -2.50 -1.25 x 180 . Convert K to radius: flat K = 337.5/43.00 = 7.85 mm , steep K = 337.5/44.50 = 7.58 mm . Apply the flatter-than-flat-K rule: 7.85 + 0.8 = 8.65 mm — select a soft lens base curve of 8.6 mm . Because cylinder is 1.25 D (≥0.75 D), select a soft toric lens with power -2.50 -1.25 x 180. Confirm centration, rotation (typically ≤5 degrees acceptable for a toric), and movement at dispensing.

Worked Example: RGP Fit (On-K)

A 40-year-old patient has K readings of 42.00 / 43.00 D and an ocular refraction of -3.00 -1.00 x 090 . The fitter chooses an on-K fit on the flat K (42.00 D, radius 8.04 mm). The tear lens is plano, so the lens power equals the ocular Rx: -3.00 -1.00 x 090 . (Note: most RGP fittings use the manifest refraction reduced to the corneal plane.) If the fitter instead fits 0.50 D steeper (base curve 42.50 D), the tear lens is +0.50 D and the lens power becomes -3.50 -1.00 x 090. The relationship must be tracked through every parameter change.

Key Takeaways

Soft lens base curve : 0.8-1.2 mm flatter than flat K (or average K rule); choose from standard curves (8.4, 8.6, 8.8 mm)

RGP base curve : on-K, steeper-than-flat-K, or flatter-than-flat-K by philosophy; calculate the tear lens and adjust lens power

Modality : spherical soft ≤0.75 D astig; toric soft ≥0.75 D; RGP for irregular cornea; scleral for keratoconus/severe irregularity; hybrid for irregular with comfort priority

Scleral lenses vault the cornea and rest on conjunctiva — first-line for moderate-to-advanced keratoconus and severe ocular surface disease

Lens Power = Ocular Rx - Tear Lens Power for RGP fits — a high-yield formula