Study guide
6.2 Medical History, Diseases, Medications & Allergies
NCLE CLRE Contact Lens Registry Exam Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
0.1 About the CLRE Exam 0.2 How to Use This Study Guide
2 Ocular Anatomy: Adnexa
Tear Film: Layers, Glands & Break-Up Time Conjunctiva, Lids, Lashes, Fornix & Canthi Blink Rate, Lid Function & Contact Lens Wear Effects
3 Ocular Anatomy: Anterior & Posterior Segment
Corneal Layers, Curvature, Topography & Metabolism Iris, Pupil, Sclera & Anterior Chamber Crystalline Lens, Retina, Choroid & Posterior Chamber
4 Refractive Errors & Contact Lens Optics
Myopia, Hyperopia, Astigmatism, Presbyopia & Anisometropia Refraction, Prism, Lacrimal Lens, Accommodation & Transposition Vertex Distance, Sagittal Depth & Spherical Equivalent
5 Measurement Instrumentation
Keratometer/Ophthalmometer: Calibration, Readings & Interpretation Corneal Topography & OCT for Contact Lens Fitting Schirmer Tests & Tear Break-Up Time
6 Observation & Verification Instrumentation
Slit Lamp (Biomicroscope) Operation & Illumination Slit Lamp Evaluation With & Without Contact Lenses Radiuscope, Lensometer, Thickness Gauge & ANSI Z80
7 Prefitting Patient Evaluation
6.1 Lifestyle, Occupation, Environment & Motivation 6.2 Medical History, Diseases, Medications & Allergies 6.3 Contraindications & Factors for Successful Wear 6.4 Relating Corneal Measurements, Rx & Lens Parameters
8 Lens Materials, Design & Parameter Selection
Dk, Dk/t, Thermal Conductivity & Holden-Mertz Water Content, Wetting Angle, Modulus, Silicone Hydrogel & Surface Treatments Toric, Multifocal, Aspheric, Hybrid, Scleral, Orthokeratology & Quadrant-Specific Base Curve, Peripheral Curves, Diameter, Thickness, Power & Edge Design
9 Diagnostic Fitting Procedures
8.1 Lens Selection & Application Procedures 8.2 Fluorescein Pattern Evaluation for RGP Lenses 8.3 Soft Lens Movement, Centration & Coverage
10 Fit Evaluation & Over-Refraction
Toric Lens Axis Rotation, LARS Rule & Stabilization Patient Comfort, Visual Acuity & Over-Refraction Modifying Base Curve, Diameter, Sag & Power from Findings
11 Dispensing: Wearing Schedules & Replacement
Daily, Flexible & Extended/Continuous Wear Schedules Daily, Biweekly, Monthly & Conventional Replacement Adaptation Protocols & Patient Compliance Counseling
12 Dispensing: Lens Care Systems
Solution Compatibility with Lens Types Chemical, Heat/UV, Hydrogen Peroxide & Neutralization Surfactant Cleaners, Protein Removers & Weekly Cleaning Solution Sensitivities, Incompatibilities & Adverse Reactions
13 Dispensing: Handling & Hygiene
12.1 Soft Lens Insertion & Removal Techniques 12.2 RGP Insertion, Removal & Emergency Responses 12.3 Hygiene, Soaps, Cosmetics & Storage Containers 12.4 Verifying Lens Parameters Against the Order at Dispensing
14 Follow-Up: Subjective & Objective Findings
13.1 Subjective Complaints: Dryness, Awareness, Blurry Vision, Pain & Photophobia 13.2 Steep vs Flat Lens Fit (Rigid & Soft) & Everted Lens 13.3 Injection, Edema, Discharge, Vision Loss & Lid Problems 13.4 Visual Acuity, Over-Refraction & Gross Evaluation Techniques
15 Follow-Up: Staining Patterns & Complications
14.1 Staining Patterns: 3 & 9 O'Clock, Foreign Body, SPK, Arcuate, Smile & Dimple Veiling 14.2 SEAL, CLARE, VLK, SLK & CLPU 14.3 Microbial Keratitis, Acanthamoeba, Dendritic Ulcer & Infiltrates 14.4 Corneal Molding/Warpage, Dellen & Mucin Balls
16 Follow-Up: Management Protocols
GPC, Blepharitis, Ptosis & Tarsal Plate Evaluation Daily Wear, Extended, Therapeutic, Postsurgical & Pathology Protocols Changing Lens Parameters at Follow-Up & Documenting Records
17 Regulatory & Administrative
FCLCA, FDA, FTC, Contact Lens Rule & Prescriber Verification HIPAA, PHI, OSHA, CDC, ANSI & Universal Precautions Record Retention, Inventory, Ordering & Documentation Methodology
6.2 Medical History, Diseases, Medications & Allergies
Key Takeaways Explain This Topic AI
Systemic diseases commonly affect CL tolerance: diabetes reduces corneal sensitivity and healing; thyroid disease causes dry eye and exophthalmos; Sjogren's and rheumatoid arthritis cause severe aqueous-deficient dry eye
Isotretinoin (Accutane) is an absolute contraindication for CL wear — it causes severe dry eye and is teratogenic; antihistamines, decongestants, beta-blockers, and oral contraceptives reduce tear volume
Oular allergies (perennial, seasonal, solution preservative, GPC) may require preservative-free care systems, daily disposables, or postponement of fitting
Pregnancy causes fluid retention, corneal curvature steepening, and reduced tear production — fitting new lenses during pregnancy is generally deferred
Age groups require special consideration: pediatric patients need therapeutic/orthokeratology fits with parental supervision; presbyopic patients need multifocal or monovision; geriatric patients face dexterity and tear challenges
Last updated: July 2026
6.2 Medical History, Diseases, Medications & Allergies
Quick Answer: The prefitting medical history targets systemic conditions and drugs that change the ocular surface. Diabetes reduces corneal sensitivity and healing; thyroid disease and Sjogren's syndrome cause dry eye; isotretinoin (Accutane) is an absolute contraindication because it causes severe dry eye. Antihistamines, beta-blockers, decongestants, and oral contraceptives reduce tear volume. Pregnancy, age extremes, and ocular allergies modify lens choice. Document each before fitting.
Why Systemic History Determines CL Success
The cornea is avascular and depends on the tear film for oxygen, nutrients, and immune defense. Any systemic condition or drug that alters tears, lids, innervation, or immunity changes the safety profile of a contact lens. The CLRE blueprint expects candidates to identify which conditions and medications modulate — or prohibit — lens wear.
Systemic Diseases That Affect Contact Lens Wear
Disease Ocular Effect CL Implication
Diabetes mellitus Reduced corneal sensitivity, delayed epithelial healing, recurrent erosions, neurotrophic keratitis Fit with caution; high-Dk lenses; shorter wearing time; closer follow-up
Thyroid disease (hyper/hypo) Dry eye, lid lag, exophthalmos, exposure keratopathy Lubrication; avoid EW; consider scleral for exposure
Sjogren's syndrome Severe aqueous-deficient dry eye, filamentary keratitis Often contraindicated for soft lenses; scleral lenses may be the only option
Rheumatoid arthritis / SLE Secondary Sjogren's, dry eye, episcleritis Same as Sjogren's; scleral lens for severe cases
HIV / AIDS Reduced immune defense, increased infection risk, KCS Fit only when necessary; strict hygiene; daily disposable preferred
Atopic disease (asthma, eczema) Allergic conjunctivitis, GPC risk Daily disposable; preservative-free care; avoid EW
- Hypertension (on beta-blockers) Reduced tear secretion See medications below
- Alcohol, Recreational Drugs & Contact Lens Wear
Domain I pathology also expects recognition of substance-related ocular effects :
Exposure Ocular / Tear Effect CL Implication
Alcohol Dehydration, reduced tear volume, impaired blink/attention Counsel against overnight wear when intoxicated; higher dryness and handling errors
Recreational drugs (e.g., cannabis, stimulants, opioids) Dry eye, pupil changes, reduced compliance, delayed care-seeking Document use; prefer daily disposables; escalate red-eye/pain urgently
Smoking / vaping Tear instability, higher infection risk Strong hygiene counseling; avoid EW
Ask nonjudgmentally during history. A patient who wears lenses while intoxicated or who uses recreational drugs may present with solution noncompliance, case contamination, or delayed reporting of pain — classic CLRE red flags.
Diabetes — A High-Yield Exam Topic
Diabetic patients have reduced corneal sensitivity (diabetic neurotrophic keratopathy) and delayed epithelial healing . A small abrasion that a non-diabetic patient heals overnight may persist for days in a diabetic, escalating to microbial keratitis. Fitting principles:
- Use high-Dk silicone hydrogel or RGP/scleral lenses to maximize oxygen
- Avoid extended wear — overnight hypoxia compounds healing risk
- Shorter wearing time with gradual build-up
- More frequent follow-up in the first month
- Counsel the patient that any red, painful eye is an immediate remove-and-call event
- Thyroid Disease
Both hyperthyroid (Graves') and hypothyroid states affect the ocular surface. Graves' ophthalmopathy causes lid retraction, lagophthalmos, and exophthalmos — the exposed cornea dries, especially at night. Hypothyroidism reduces tear production. Fitting principles:
- Avoid extended wear (already compromised nocturnal protection)
- Use lubricating drops and ointment at bedtime
- Consider scleral lenses for severe exposure — they vault the cornea and hold a fluid reservoir
- Monitor for exposure keratopathy at follow-up
- Medications and Contact Lens Wear
Medication Class Effect on Ocular Surface CL Action
Antihistamines (oral) Anticholinergic effect reduces tear volume Daily disposable; lubricating drops; shorter wearing time
Decongestants (pseudoephedrine) Reduce tear secretion Same as antihistamines
Beta-blockers (timolol, systemic propranolol) Reduce aqueous tear production May need lower water content lens; lubrication
Isotretinoin (Accutane) Severe dry eye, meibomian gland atrophy ABSOLUTE CONTRAINDICATION — defer fitting until 6 months after discontinuation
- Oral contraceptives Mild dry eye, contact lens intolerance in some Change modality if intolerance develops
- Antidepressants (SSRIs, tricyclics) Anticholinergic dry eye Lubrication; daily disposable
- Diuretics Reduced tear volume Lubrication
Immunosuppressants (chemo, biologics) Mucositis, dry eye, infection risk Defer during active treatment; daily disposable when stable
- Amiodarone Corneal verticillata (whorl-like deposits) Usually visually insignificant; document baseline
- Phenothiazines / antimalarials Corneal epithelial deposits Document; usually not a CL contraindication
- The Isotretinoin Rule — Absolute Contraindication
Isotretinoin (Accutane) causes severe, persistent dry eye through meibomian gland atrophy and reduced aqueous tear production. It is also highly teratogenic. The standard of care is to defer contact lens fitting until at least 6 months after discontinuation and tear function has normalized. Some references require Schirmer and TBUT normalization before fitting. The exam may present a patient on isotretinoin requesting lenses — the correct answer is to defer, not to fit with a dry-eye lens.
Allergies and Contact Lens Wear
Allergic history is critical because allergy both reduces tolerance and dictates care-system choice.
Seasonal / perennial allergic conjunctivitis — fit during a quiescent period; daily disposable preferred; prescribe allergy drops (antihistamine/mast-cell stabilizer) if needed.
Giant papillary conjunctivitis (GPC) history — daily disposable or RGP (less mechanical trauma); avoid soft lenses with high lipid deposition; consider mast-cell stabilizer.
Solution preservative allergy (thimerosal, chlorhexidine) — switch to preservative-free or hydrogen peroxide systems; daily disposables eliminate solution exposure entirely.
Pollen / environmental allergy — counsel that symptoms worsen in spring; cool compresses; daily disposable.
- Special Populations
- Pediatric Patients
Pediatric fits are usually therapeutic (aphakia, anisometropic amblyopia, keratoconus, orthokeratology for myopia control). Parental supervision is required for insertion, removal, and hygiene. Children often tolerate lenses well and have robust tears, but the fitter must train the parent and document competence.
Presbyopic Patients (>40 years)
Presbyopia requires a modality decision:
- Multifocal soft lenses — simultaneous vision design; Convenience vs. contrast sensitivity tradeoff
- Monovision — one eye distance, one eye near; high success rate but reduces stereopsis and contrast
- Modified monovision — multifocal in dominant eye, single-vision near in non-dominant
- RGP bifocals / scleral multifocals — better optics for high astigmatism or irregular corneas
- Geriatric Patients (>65 years)
Reduced tear production, lid laxity, and decreased manual dexterity are common. Daily disposable lenses with insertion/removal aids, large-handle tweezers, and a stable wearing schedule are often the best choice.
Pregnancy and Lactation
Pregnancy causes hormonal fluid retention , corneal curvature steepening (myopic shift), reduced tear production , and immunologic modulation . Existing lens wearers may develop intolerance. Fitting new lenses during pregnancy is generally deferred until several weeks postpartum or after lactation, when the refraction and tear film stabilize. Any fit during pregnancy should use daily disposables with conservative wearing time and close follow-up. Isotretinoin and tetracycline-class drugs are also contraindicated in pregnancy — a double reason to defer.
- Key Takeaways
- Diabetes reduces corneal sensitivity and healing — fit with high-Dk lenses, no extended wear, close follow-up
- Isotretinoin (Accutane) is an absolute contraindication — defer 6 months post-discontinuation
Antihistamines, decongestants, beta-blockers, oral contraceptives, SSRIs all reduce tear volume — modulate lens and care regimen
- Pregnancy steepens the cornea and dries the tear film — defer new fits until postpartum
- GPC and preservative allergy favor daily disposables or preservative-free hydrogen peroxide systems