Study guide
Refraction, Prism, Lacrimal Lens, Accommodation & Transposition
NCLE CLRE Contact Lens Registry Exam Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
0.1 About the CLRE Exam 0.2 How to Use This Study Guide
2 Ocular Anatomy: Adnexa
Tear Film: Layers, Glands & Break-Up Time Conjunctiva, Lids, Lashes, Fornix & Canthi Blink Rate, Lid Function & Contact Lens Wear Effects
3 Ocular Anatomy: Anterior & Posterior Segment
Corneal Layers, Curvature, Topography & Metabolism Iris, Pupil, Sclera & Anterior Chamber Crystalline Lens, Retina, Choroid & Posterior Chamber
4 Refractive Errors & Contact Lens Optics
Myopia, Hyperopia, Astigmatism, Presbyopia & Anisometropia Refraction, Prism, Lacrimal Lens, Accommodation & Transposition Vertex Distance, Sagittal Depth & Spherical Equivalent
5 Measurement Instrumentation
Keratometer/Ophthalmometer: Calibration, Readings & Interpretation Corneal Topography & OCT for Contact Lens Fitting Schirmer Tests & Tear Break-Up Time
6 Observation & Verification Instrumentation
Slit Lamp (Biomicroscope) Operation & Illumination Slit Lamp Evaluation With & Without Contact Lenses Radiuscope, Lensometer, Thickness Gauge & ANSI Z80
7 Prefitting Patient Evaluation
6.1 Lifestyle, Occupation, Environment & Motivation 6.2 Medical History, Diseases, Medications & Allergies 6.3 Contraindications & Factors for Successful Wear 6.4 Relating Corneal Measurements, Rx & Lens Parameters
8 Lens Materials, Design & Parameter Selection
Dk, Dk/t, Thermal Conductivity & Holden-Mertz Water Content, Wetting Angle, Modulus, Silicone Hydrogel & Surface Treatments Toric, Multifocal, Aspheric, Hybrid, Scleral, Orthokeratology & Quadrant-Specific Base Curve, Peripheral Curves, Diameter, Thickness, Power & Edge Design
9 Diagnostic Fitting Procedures
8.1 Lens Selection & Application Procedures 8.2 Fluorescein Pattern Evaluation for RGP Lenses 8.3 Soft Lens Movement, Centration & Coverage
10 Fit Evaluation & Over-Refraction
Toric Lens Axis Rotation, LARS Rule & Stabilization Patient Comfort, Visual Acuity & Over-Refraction Modifying Base Curve, Diameter, Sag & Power from Findings
11 Dispensing: Wearing Schedules & Replacement
Daily, Flexible & Extended/Continuous Wear Schedules Daily, Biweekly, Monthly & Conventional Replacement Adaptation Protocols & Patient Compliance Counseling
12 Dispensing: Lens Care Systems
Solution Compatibility with Lens Types Chemical, Heat/UV, Hydrogen Peroxide & Neutralization Surfactant Cleaners, Protein Removers & Weekly Cleaning Solution Sensitivities, Incompatibilities & Adverse Reactions
13 Dispensing: Handling & Hygiene
12.1 Soft Lens Insertion & Removal Techniques 12.2 RGP Insertion, Removal & Emergency Responses 12.3 Hygiene, Soaps, Cosmetics & Storage Containers 12.4 Verifying Lens Parameters Against the Order at Dispensing
14 Follow-Up: Subjective & Objective Findings
13.1 Subjective Complaints: Dryness, Awareness, Blurry Vision, Pain & Photophobia 13.2 Steep vs Flat Lens Fit (Rigid & Soft) & Everted Lens 13.3 Injection, Edema, Discharge, Vision Loss & Lid Problems 13.4 Visual Acuity, Over-Refraction & Gross Evaluation Techniques
15 Follow-Up: Staining Patterns & Complications
14.1 Staining Patterns: 3 & 9 O'Clock, Foreign Body, SPK, Arcuate, Smile & Dimple Veiling 14.2 SEAL, CLARE, VLK, SLK & CLPU 14.3 Microbial Keratitis, Acanthamoeba, Dendritic Ulcer & Infiltrates 14.4 Corneal Molding/Warpage, Dellen & Mucin Balls
16 Follow-Up: Management Protocols
GPC, Blepharitis, Ptosis & Tarsal Plate Evaluation Daily Wear, Extended, Therapeutic, Postsurgical & Pathology Protocols Changing Lens Parameters at Follow-Up & Documenting Records
17 Regulatory & Administrative
FCLCA, FDA, FTC, Contact Lens Rule & Prescriber Verification HIPAA, PHI, OSHA, CDC, ANSI & Universal Precautions Record Retention, Inventory, Ordering & Documentation Methodology
Refraction, Prism, Lacrimal Lens, Accommodation & Transposition
Key Takeaways Explain This Topic AI
Prentice's rule (P = c × F) governs decentration prism; contact lenses eliminate it because the lens moves with the eye and the optical center stays aligned with the visual axis.
The lacrimal (tear) lens behind an RGP masks corneal astigmatism; a soft lens drapes over the cornea and reveals it as residual astigmatism.
SAM/FAP rule: a base curve steeper than the flat K creates a plus tear lens, so add minus (SAM); a base curve flatter than the flat K creates a minus tear lens, so add plus (FAP).
Myopes accommodate more in CLs than in spectacles; hyperopes accommodate less in CLs than in spectacles because of vertex distance and vergence-accommodation effects.
Transposition from plus-cylinder to minus-cylinder: new sphere = old sphere + old cyl, new cyl = -(old cyl), new axis = old axis ± 90°; spherical equivalent = sphere + cyl/2.
Last updated: July 2026
Refraction, Prism, Lacrimal Lens, Accommodation & Transposition
Quick Answer: Contact lens optics differ from spectacle optics because the lens sits on the tear film at the corneal plane. The lacrimal (tear) lens formed behind an RGP masks corneal astigmatism; decentration prism is negligible because the lens moves with the eye; and accommodative demand differs from spectacles because vertex distance is zero. The SAM/FAP rule and transposition formulas let you adjust power reliably.
Refraction Principles
When light crosses an interface between media of different refractive indices, it bends according to Snell's law : n₁ sin θ₁ = n₂ sin θ₂. A contact lens's refractive index (~1.40 for soft hydrogel, ~1.49 for RGP) and the curvature of its optic zone combine with the tear film and cornea to focus light on the retina.
Total corneal power is approximately +43 D (dominated by the steep anterior surface); the crystalline lens adds ~+19 D. The contact lens adds or subtracts the residual refractive error needed to bring the image to focus on the retina. Because the CL sits millimeters from the corneal apex, its effective power and its interactions with the tear film differ fundamentally from a spectacle lens at 12 mm.
Prismatic Effects
Prentice's rule: P = c × F, where P is prism in prism diopters (Δ), c is decentration in centimeters, and F is lens power in diopters.
With spectacles , off-axis gaze through the lens periphery induces prism — a -10.00 D lens decentered 1 cm produces 10Δ of base-in prism. In anisometropia, this causes vertical imbalance in down-gaze (often symptomatic above 1.5Δ of vertical differential prism).
With contact lenses , the lens moves with the eye. The optical center stays aligned with the visual axis under all gaze positions, so decentration prism is essentially eliminated. This is why anisometropic patients tolerate CLs far better than spectacles and why spectacle-only prescriptions can fail in high anisometropia.
Diffraction (Domain II Optics Terminology)
Diffraction is the bending and spreading of light waves as they pass an aperture or edge — for example, the pupil margin or a multifocal zone transition. Diffraction limits how finely an optical system can resolve detail (Airy disk) and contributes to night glare/halos when pupils dilate. On the CLRE, distinguish:
- Term What it is CL relevance
- Refraction Bending of light at an interface (Snell's law) Spectacle vs CL power, tear lens
Diffraction Wave spreading at an aperture/edge Pupil size effects; multifocal/diffractive designs; night vision complaints
Prismatic effects Image displacement from decentration (Prentice's rule) Anisometropia; why CLs reduce differential prism vs spectacles
Know the word diffraction as an optics principle related to contact lenses — not only as a marketing label on "diffractive" multifocal designs.
Residual Astigmatism: What RGP Masks vs. Soft Reveals
The lacrimal lens (tear lens) is the thin tear layer between the back surface of an RGP and the front surface of the cornea. Because the RGP is rigid, the tear layer fills in any irregular or toric corneal shape — optically, the corneal surface becomes the smooth back curve of the RGP.
- Lens Type Behavior with Corneal Astigmatism
- RGP Tear lens masks corneal astigmatism → residual astigmatism ≈ 0 (only lenticular astigmatism remains)
- Soft CL Drapes over cornea → corneal astigmatism is "revealed" → must be corrected with a toric soft lens
- Scleral Vaults cornea; fluid reservoir masks both corneal and irregular astigmatism
Lenticular astigmatism (from the crystalline lens) cannot be masked by any contact lens — it remains as residual astigmatism regardless of lens type. If a patient has more than ~0.75 D of residual astigmatism with an RGP, a toric CL (soft toric or RGP back-surface toric) is typically required.
The Lacrimal Lens & SAM/FAP Rule
The lacrimal lens has refractive power that depends on the relationship between the RGP base curve and the corneal curvature (K readings).
If RGP base curve is steeper than the flat K → tear lens is plus power → must add minus to the CL to compensate ( SAM = Steep Add Minus)
If RGP base curve is flatter than the flat K → tear lens is minus power → must add plus to the CL ( FAP = Flat Add Plus)
- If RGP base curve matches the flat K → no tear lens power adjustment needed
- Worked Example A (SAM)
- Corneal Ks: 43.00 / 44.50 D (1.50 D WTR astigmatism)
RGP fitted "on flat K" with base curve = 43.00 D → no tear lens adjustment; the 1.50 D of corneal astigmatism is masked by the tear lens and needs no cyl in the CL.
RGP fitted 0.50 D steeper, base curve = 43.50 D → tear lens is +0.50 D → add −0.50 D to the CL power (SAM).
Worked Example B (FAP)
RGP fitted 0.75 D flatter than flat K, base curve = 42.25 D → tear lens is −0.75 D → add +0.75 D to the CL power (FAP).
Memory aid: SAM the FAP — "Steep Add Minus, Flat Add Plus." Always reference the flat K (not the steep K) when computing the difference.
Accommodation Differences: CL vs. Spectacle
Because contact lenses sit at the corneal plane (vertex distance ≈ 0) and spectacles sit ~12 mm away, effective power at the eye differs — and so does the accommodative demand for near work.
Myopes: contact lens wearers accommodate more than spectacle wearers. The spectacle minus lens at 12 mm has less minus at the corneal plane, effectively reducing near demand; the CL delivers full minus to the cornea, removing that assist.
Hyperopes: contact lens wearers accommodate less than spectacle wearers. The spectacle plus lens at 12 mm has more plus at the corneal plane than its labeled power, and base-out prism at near drives vergence-accommodation; CLs remove both effects.
Clinical implication: a 40-year-old emerging presbyope who is a high myope in spectacles may not yet need a near add, but may need one when refit with CLs because the accommodative "help" from the spectacles is gone. Conversely, a high hyperope may find near tasks easier in CLs than in spectacles.
Transposition of Prescriptions
Ophthalmic prescriptions can be written in plus-cylinder (ophthalmology convention) or minus-cylinder (optometry and CL convention). Contact lens manufacturers specify prescriptions in minus cylinder. To convert plus-cyl to minus-cyl:
- New sphere = old sphere + old cylinder
- New cylinder = −(old cylinder) (sign flipped, magnitude same)
- New axis = old axis ± 90° (transpose 90°)
- Worked Example
- +1.00 +2.00 × 090 (plus cyl) →
- New sphere: +1.00 + 2.00 = +3.00
- New cyl: −2.00
- New axis: 090 + 90 = 180
- Result: +3.00 −2.00 × 180
Verify by computing the spherical equivalent (SE) of both forms — they must match: SE = +1.00 + 2.00/2 = +2.00 D, and SE = +3.00 + (−2.00)/2 = +2.00 D. ✓
Spherical Equivalent
The spherical equivalent collapses a spherocylindrical prescription into a single sphere value. It is used for trial lens fitting, soft CL power selection when only spherical lenses are available, and for vertex compensation calculations.
SE = sphere + (cylinder / 2)
Examples:
- −2.00 −1.00 × 180 → SE = −2.00 + (−0.50) = −2.50 D
- +1.50 +0.75 × 090 → SE = +1.50 + 0.375 = +1.875 D (round to +1.75 or +2.00)
- 5.00 -2.00 × 180 → SE = -5.00 + (-1.00) = -6.00 D