Study guide
11.3 CPT and ICD-10 Coding for LTM Services
ABRET Certified Long Term Monitoring Technologist CLTM
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Pre-Study Preparation & Clinical Indications
1.1 Clinical Indications for Long-Term Monitoring 1.2 Patient History, Clinical Assessment & Neurological Evaluation 1.3 Recording Strategy, Protocol Planning & Patient Communication
2 Chapter 2: Electrodes, Montages & Technical Setup
2.1 Electrode Selection, Application & Scalp Integrity 2.2 True and Modified Montages for LTM 2.3 Instrument Settings, Calibration & Differential Amplification 2.4 Signal Integrity, Impedance Monitoring & Artifact Troubleshooting
3 Chapter 3: Seizure Classification, Semiology & Clinical Events
3.1 ILAE 2017 Seizure Classification Framework 3.2 Seizure Semiology & Ictal Phenotypes 3.3 Differentiating Epileptic vs Non-Epileptic Events 3.4 Event Button Workflow, Clinical Testing & Ictal Observation
4 Chapter 4: EEG Waveform Identification & Interictal Discharges
4.1 Normal Variants and Benign Epileptiform Patterns 4.2 Interictal Epileptiform Discharges (IEDs) 4.3 Electrographic and Electroclinical Seizure Patterns
5 Chapter 5: ICU Continuous EEG & Critical Care Monitoring
5.1 ACNS Standardized Critical Care Terminology 5.2 Non-Convulsive Status Epilepticus (NCSE) & Salzburg Criteria 5.3 Coma Patterns, Burst Suppression & Prognostication 5.4 Quantitative EEG (qEEG) Trends & ICU Trending Tools
6 Chapter 6: Age-Specific Monitoring: Neonatal & Pediatric LTM
6.1 Neonatal EEG & Continuous Monitoring 6.2 Pediatric Epilepsy Syndromes in the EMU 6.3 Pediatric Technical Considerations & Behavioral Strategies
7 Chapter 7: Invasive Intracranial Monitoring & Functional Mapping
7.1 Intracranial Recording Modalities (Grids, Strips, SEEG) 7.2 Extraoperative Functional Brain Mapping & Cortical Stimulation 7.3 Somatosensory Evoked Potentials (SEPs) & Central Sulcus Localization
8 Chapter 8: Provocative Testing & In-Study Interventions
8.1 Activation Procedures in LTM (HV, Photic, Sleep Deprivation) 8.2 Medication Withdrawal & Provocation Protocols 8.3 Emergency Escalation & Status Epilepticus Management
9 Chapter 9: Post-Study Procedures, Technical Reporting & Localization
9.1 Technical Summary & Technologist Reporting 9.2 Data Review, Reformatting & Montage Re-montaging 9.3 Localization Techniques & Dipole Principles 9.4 Study Completion, Electrode Removal & Infection Prevention
10 Chapter 10: Data & Equipment Management
10.1 Video-EEG Synchronization & Audio-Visual Systems 10.2 Data Pruning, Clipping & Archiving 10.3 Network Infrastructure, Server Systems & Hardware Maintenance
11 Chapter 11: Ethics, Patient Safety & Professional Standards
11.1 Patient Safety Protocols & Fall Prevention in the EMU 11.2 Regulatory Compliance: HIPAA, HITECH & Video Privacy 11.3 CPT and ICD-10 Coding for LTM Services 11.4 ABRET Code of Ethics & Professional Practice Standards
11.3 CPT and ICD-10 Coding for LTM Services
Key Takeaways Explain This Topic AI
The American Medical Association (AMA) restructured Long-Term EEG Monitoring CPT coding, replacing legacy codes (95950–95956) with a granular framework separating Technical Component services (95700–95716) from Professional Component services (95717–95726).
Technical billing is selected by video versus EEG-only, 2–12 versus 12–26 hours, and monitoring intensity: unmonitored, intermittent review at least every 2 hours, or continuous real-time monitoring by a technologist responsible for no more than four patients.
Technical setup, electrode application, patient education, ongoing maintenance, and electrode takedown is billed once per multi-day monitoring session using CPT code 95700.
ICD-10-CM diagnostic coding for seizure disorders is centered in the G40 category, where the 5th character denotes intractability (0 = not intractable, 1 = intractable/refractory) and the 6th character indicates the presence of status epilepticus (1 = with status epilepticus, 9 = without status epilepticus).
Non-epileptic conditions evaluated in the EMU must be coded accurately using specific ICD-10-CM codes, including F44.5 for conversion disorder with seizures/PNES, R55 for syncope and collapse, and R56.9 for unspecified convulsions.
Last updated: August 2026
11.3 CPT and ICD-10 Coding for LTM Services
Accurate procedural and diagnostic coding is essential for operational compliance, regulatory transparency, and appropriate reimbursement in neurodiagnostic clinical practice. The coding architecture for Long-Term EEG Monitoring (LTM) underwent a comprehensive overhaul by the American Medical Association (AMA) CPT Editorial Panel, completely replacing legacy codes (such as 95950, 95951, 95953, and 95956). The modern framework establishes a distinct separation between Technical Component services (performed by neurodiagnostic technologists and facilities) and Professional Component services (physician review, clinical interpretation, and formal report generation).
Certified Long Term Monitoring Technologists (CLTM) must thoroughly understand the technical CPT coding matrix, duration thresholds, technologist-to-patient staffing ratios, and corresponding ICD-10-CM diagnostic categories.
1. Modern CPT Framework for Long-Term EEG Technical Services
Technical code selection uses four facts: whether video is recorded, whether the increment is 2–12 or 12–26 hours, how the technologist monitored the recording, and whether setup/takedown is being reported. The actual documented service—not the care setting or credential alone—controls the code.
- Recording and duration Unmonitored Intermittent monitoring Continuous real-time monitoring
- EEG without video, 2–12 hours 95705 95706 95707
- EEG without video, 12–26 hours 95708 95709 95710
- EEG with video, 2–12 hours 95711 95712 95713
- EEG with video, 12–26 hours 95714 95715 95716
95700 reports setup and takedown for the continuous recording, including patient education, electrode application, and removal. It is reported once for the recording period, not once per day.
Unmonitored means no technologist monitoring during the service increment. Intermittent monitoring requires technologist review at least every two hours, with no more than 12 recordings monitored concurrently by one technologist. Continuous real-time monitoring requires ongoing observation and a maximum technologist responsibility of four recordings. If staffing or workflow does not meet a definition, report the service that was actually performed; do not “downgrade” to a specific code without also checking video, duration, and whether intermittent-review criteria were met.
Examples:
Six hours of continuous real-time video-EEG at an eligible ratio uses 95713, plus 95700 when setup/takedown is reportable.
A 20-hour unmonitored ambulatory video-EEG increment uses 95714.
A 20-hour intermittently monitored video-EEG increment uses 95715.
A 20-hour continuously monitored video-EEG increment at an eligible ratio uses 95716.
A 20-hour continuous real-time EEG without video increment uses 95710, not a video code.
2. Timing Increments & Calendar Day Billing Rules
CPT coding guidelines establish precise duration rules for reporting technical LTM services: +-----------------------------------------------------------------------------+
- | LTM TIME-INCREMENT BILLING RULES |
- | |
- | RECORDING DURATION < 2 HOURS: |
- | - Cannot bill LTM codes (95700-95716). |
- | - Must bill standard routine / extended EEG codes: |
- | * 95816: Routine EEG, awake and drowsy (20-40 min) |
- | * 95819: Routine EEG, awake and asleep |
- | * 95812: Extended EEG (41-60 minutes) |
- | * 95813: Extended EEG (>60 minutes, up to 119 minutes) |
- | |
- | SHORT DURATION LTM (2 TO 12 HOURS): |
- | - Billed when total recording duration in an epoch is between 2 and 12 hrs|
- | - Examples: 95705, 95706, 95707, 95711, 95712, 95713 |
- | |
- | LONG DURATION LTM (12 TO 26 HOURS PER CALENDAR DAY): |
- | - Billed once per 24-hour calendar day epoch (between 12 and 26 hours) |
- | - Examples: 95708, 95709, 95710, 95714, 95715, 95716 |
- | - A continuous 72-hour EMU admission typically yields: |
- | * 1 unit of 95700 (Setup / Takedown) |
- | * 3 units of 95716 (One unit per calendar day of continuous VEEG) |
- +-----------------------------------------------------------------------------+
- 3. Professional Component Services (Physician Interpretation)
While technologists bill the technical series, interpreting physicians bill dedicated professional CPT codes for data review, electroclinical correlation, medical synthesis, and generation of the final medical report:
Professional CPT Code Duration & Modality Clinical Scope / Requirements
95717 2–12 hrs, without video Physician review of EEG data, interpretation, and written report.
95718 2–12 hrs, with video Physician review of synchronized video and EEG data, clinical semiology correlation, and written report.
95719 12–26 hrs, without video Daily review of EEG background and discharges, interpretation, and daily written report.
95720 12–26 hrs, with video Daily review of synchronized VEEG, seizure semiology analysis, and daily written report.
95721–95726 Multi-day / Extended (36–84+ hrs) Cumulative multi-day physician review and final comprehensive report across extended monitoring admissions (with or without video and ASM tapering).
4. ICD-10-CM Clinical Coding for Seizure Disorders & Epilepsy
Diagnostic coding for neurodiagnostic procedures utilizes the International Classification of Diseases, Tenth Revision, Clinical Modification (ICD-10-CM) . Seizure disorders are classified primarily within the G40 category (Epilepsy and recurrent seizures) . +-----------------------------------------------------------------------------+
- | ICD-10-CM G40 EPILEPSY CATEGORY STRUCTURE |
- | |
- | [BASE CATEGORY CODES] |
- | - G40.0: Localization-related (focal) idiopathic epilepsy |
- | (e.g., Benign childhood epilepsy with centrotemporal spikes / Rolandic) |
- | - G40.1: Localization-related symptomatic epilepsy with simple partial |
- | seizures (Focal Aware Seizures) |
- | - G40.2: Localization-related symptomatic epilepsy with complex partial |
- | seizures (Focal Impaired Awareness Seizures) |
- | - G40.3: Generalized idiopathic epilepsy and epileptic syndromes |
- | (e.g., Childhood Absence Epilepsy, Juvenile Myoclonic Epilepsy / JME) |
- | - G40.4: Other generalized epilepsy (e.g., Lennox-Gastaut Syndrome) |
- | - G40.8: Other epilepsy (e.g., Epilepsia partialis continua) |
- | - G40.9: Epilepsy, unspecified |
- +-----------------------------------------------------------------------------+
- 5th and 6th Character Subclassifications
The G40 series requires 5th and 6th characters to specify intractability (pharmacoresistance) and the presence of status epilepticus : G 4 0 . X [5th] [6th]
- | |
- +------------------------------+ +------------------------------+
- | 5th Character: INTRACTABILITY | 6th Character: STATUS EPILEPTICUS
- | 0 = Not intractable (Controlled) | 1 = With status epilepticus
- | 1 = Intractable (Refractory / | 9 = Without status epilepticus
- | Pharmacoresistant) |
- +-------------------------------------+------------------------------+
Clinical Coding Examples:
G40.211: Localization-related (focal) symptomatic epilepsy with complex partial seizures, intractable , with status epilepticus .
G40.219: Localization-related (focal) symptomatic epilepsy with complex partial seizures, intractable , without status epilepticus (the most frequent ICD-10 code for adult presurgical EMU admissions).
G40.309: Generalized idiopathic epilepsy, not intractable , without status epilepticus .
G40.419: Other generalized epilepsy (Lennox-Gastaut syndrome), intractable , without status epilepticus .
5. Non-Epileptic Paroxysmal Event ICD-10 Coding
A major indication for EMU admission is the differential diagnosis of paroxysmal spells that mimic epileptic seizures. Technologists must be familiar with the standardized diagnostic codes for non-epileptic conditions:
ICD-10-CM Code Clinical Diagnostic Term Diagnostic & Clinical Characteristics
F44.5 Conversion disorder with seizures or convulsions Psychogenic Non-Epileptic Seizures (PNES) / Functional Neurological Disorder (FND); paroxysmal spells with motor thrashing or unresponsiveness without concurrent ictal electrographic discharge or post-ictal slowing.
R55 Syncope and collapse Vasovagal syncope, orthostatic hypotension, or cardiogenic syncope; characterized on EEG by generalized slowing evolving to diffuse voltage attenuation during cerebral hypoperfusion.
R56.9 Unspecified convulsions Convulsive episode of undetermined etiology, frequently used as the provisional admission diagnosis prior to definitive VEEG monitoring.
G47.411 / G47.419 Narcolepsy with / without cataplexy Rapid sleep onset REM periods, sleep paralysis, and sudden loss of motor tone triggered by emotion without epileptic EEG activity.
G25.3 Myoclonus Non-epileptic physiological, metabolic, or essential myoclonus lacking cortical epileptiform spike triggers.
6. Comprehensive Coding Vignettes for the CLTM Examination ===============================================================================
- CLINICAL CODING SCENARIOS & CODE SELECTION
- ===============================================================================
CASE 1: Inpatient Presurgical EMU Evaluation (3-Day Admission)
- Patient: 29-year-old female with drug-resistant focal temporal lobe epilepsy.
- Procedure: Continuous video-EEG monitoring in EMU from Monday 09:00 to Thursday
09:00 (72 continuous hours) with dedicated technologist 1:3 staffing ratio.
- Diagnosis: Refractory complex partial seizures without status epilepticus.
- Appropriate Coding:
- * Technical Setup: 95700 (1 unit)
- * Technical Monitoring: 95716 x 3 units (1 unit per calendar day epoch)
- * Primary ICD-10: G40.219 (Localization-related symptomatic epilepsy with
- complex partial seizures, intractable, without status epilepticus)
CASE 2: Diagnostic Spell Characterization (6-Hour EMU Study)
- Patient: 42-year-old male with recurrent unprovoked paroxysmal shaking spells.
- Procedure: 6-hour continuous video-EEG study monitored in real-time by technologist.
- Findings: Habitual spell captured with out-of-phase limb thrashing, preserved
waking alpha background, and no epileptiform discharge.
- Final Physician Diagnosis: Psychogenic Non-Epileptic Seizures (Conversion Disorder).
- Appropriate Coding:
- * Technical Setup: 95700 (1 unit)
- * Technical Monitoring: 95713 (2 to 12 hours continuous VEEG with technologist)
- * Primary ICD-10: F44.5 (Conversion disorder with seizures or convulsions)
CASE 3: Ambulatory Unmonitored Home Video-EEG (48-Hour Study)
- Patient: 16-year-old male with suspected juvenile absence epilepsy.
- Procedure: Take-home ambulatory VEEG recorder; no real-time technologist review.
- Diagnosis: Generalized idiopathic epilepsy, not intractable.
- Appropriate Coding:
- * Technical Setup: 95700 (1 unit)
- * Technical Monitoring: 95714 x 2 units (12-26 hr unmonitored VEEG per increment)
- * Primary ICD-10: G40.309 (Generalized idiopathic epilepsy, not intractable)
- ===============================================================================