Study guide
4.2 Diagnostic Testing
CMA Certified Medical Assistant Exam Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction: CMA (AAMA) Exam Overview
CMA (AAMA) Certification Exam Overview CMA Certification Process & Eligibility Study Strategies & Test-Taking Tips
2 Chapter 1: General Knowledge (21%)
1.1 Anatomy, Physiology & Medical Terminology 1.2 Pharmacology & Nutrition 1.3 Psychology, Human Behavior & Lifespan Development 1.4 Immunizations, CDC Schedules & Vaccine Safety
3 Chapter 1B: Safety, Infection Control & Emergency Preparedness
Safety, Infection Control & Medical Asepsis Emergency Management, First Aid & Office Preparedness
4 Chapter 2: Administrative Knowledge (20%)
2.1 Medical Business Practices & Insurance 2.2 Scheduling & Records Management
5 Chapter 3: Clinical Knowledge — Patient Care
3.1 Vital Signs & Patient Assessment 3.2 Clinical Procedures & Specimen Collection
6 Chapter 4: Clinical Knowledge — Diagnostic & Lab
4.1 Laboratory Procedures 4.2 Diagnostic Testing
7 Chapter 5: Professional Practice & Communication
5.1 Professional Communication & Patient Education 5.2 Legal & Ethical Practice
4.2 Diagnostic Testing
Key Takeaways Explain This Topic AI
A standard 12-lead ECG/EKG records the electrical activity of the heart from 12 different angles using 10 electrodes (4 limb leads + 6 chest/precordial leads)
The normal ECG waveform consists of the P wave (atrial depolarization), QRS complex (ventricular depolarization), and T wave (ventricular repolarization)
Normal sinus rhythm has a rate of 60-100 bpm with a regular rhythm, upright P waves, and a consistent PR interval (0.12-0.20 seconds)
ECG artifacts are unwanted signals caused by muscle tremor (somatic), electrical interference (AC), or wandering baseline (movement, loose leads)
Pulmonary function testing (PFT) measures lung volumes and airflow — spirometry is the most common PFT and measures FVC and FEV1
Peak flow meters measure the fastest rate of expiration (PEFR) and are used for asthma monitoring — patients maintain a personal best baseline
Holter monitors record continuous ECG for 24-48 hours to detect intermittent arrhythmias not captured on a standard ECG
Patient preparation for ECG includes removing metal jewelry, having the patient lie still, ensuring skin is clean and dry at electrode sites
Last updated: February 2026
Diagnostic testing encompasses various procedures used to evaluate patient health. The CMA exam focuses on ECG/EKG, pulmonary function testing, and other common diagnostic procedures that medical assistants assist with or perform.
Electrocardiography (ECG/EKG)
What Is an ECG?
An electrocardiogram (ECG or EKG) is a non-invasive diagnostic test that records the electrical activity of the heart . It does NOT measure the mechanical pumping action — it measures the electrical impulses that trigger each heartbeat.
Standard 12-Lead ECG Setup
A 12-lead ECG uses 10 electrodes to produce 12 different views of the heart's electrical activity:
Limb Leads (4 electrodes):
- Electrode Placement Color (AHA Standard)
- RA Right arm (wrist or upper arm) White
- LA Left arm (wrist or upper arm) Black
- RL Right leg (ankle or lower leg) Green
- LL Left leg (ankle or lower leg) Red
Memory aid for limb leads: " W hite is R ight (like s now on the c hristmas tree)" — start with white on right arm, then go clockwise: white, black, red, green. Or " S moke (black) over F ire (red)" for the left side.
Precordial/Chest Leads (6 electrodes: V1-V6):
- Lead Placement
- V1 4th intercostal space, RIGHT sternal border
- V2 4th intercostal space, LEFT sternal border
- V3 Midway between V2 and V4
- V4 5th intercostal space, LEFT midclavicular line
- V5 Same horizontal level as V4, anterior axillary line
- V6 Same horizontal level as V4-V5, midaxillary line
- Normal ECG Waveform
- Component What It Represents Normal Duration
- P wave Atrial depolarization (atrial contraction) <0.12 seconds
- PR interval Time from atrial to ventricular depolarization 0.12-0.20 seconds
- QRS complex Ventricular depolarization (ventricular contraction) 0.06-0.12 seconds
- ST segment Period between ventricular depolarization and repolarization Isoelectric (flat at baseline)
- T wave Ventricular repolarization (ventricles resetting) Follows QRS
- Normal Sinus Rhythm Criteria
- Rate : 60-100 beats per minute
- Rhythm : Regular (even spacing between QRS complexes)
- P waves : Present, upright, one before each QRS
- PR interval : 0.12-0.20 seconds, consistent
- QRS complex : <0.12 seconds
- Common ECG Abnormalities (Recognition Level)
- Rhythm Key Features
- Sinus bradycardia Normal rhythm but rate <60 bpm
- Sinus tachycardia Normal rhythm but rate >100 bpm
- Atrial fibrillation Irregularly irregular rhythm, no distinct P waves, fibrillatory baseline
- Premature ventricular contractions (PVCs) Early, wide QRS complexes without preceding P wave
- Ventricular tachycardia Wide QRS at rapid rate (>150 bpm) — emergency
- Ventricular fibrillation Chaotic, no identifiable waves — cardiac arrest
- ECG Artifacts
- Artifact Type Cause Solution
- Somatic tremor Patient muscle movement, shivering Have patient relax, ensure warm room
AC (electrical) interference Nearby electrical equipment, improper grounding Unplug nearby devices, check grounding
- Wandering baseline Patient movement, breathing, loose electrodes Reapply electrodes, have patient lie still
- Interrupted baseline Loose or disconnected lead wire Check all connections, replace lead wire
- Pulmonary Function Testing (PFT)
- Spirometry
Spirometry is the most common pulmonary function test, measuring lung volumes and airflow:
- Measurement What It Measures Normal
- FVC (Forced Vital Capacity) Maximum volume exhaled after maximum inhalation ≥80% of predicted
- FEV1 (Forced Expiratory Volume in 1 second) Volume exhaled in the first second ≥80% of predicted
- FEV1/FVC ratio Percentage of FVC exhaled in 1 second ≥70%
Key interpretations:
- Obstructive disease (asthma, COPD): FEV1/FVC ratio decreased (<70%) — air trapping
- Restrictive disease (pulmonary fibrosis): FVC decreased , FEV1/FVC ratio normal or increased
- Reversibility : If FEV1 improves by ≥12% after bronchodilator, suggests asthma (reversible obstruction)
- Patient Instructions for Spirometry
- Sit upright with feet flat on the floor
- Take the deepest breath possible
- Place the mouthpiece in the mouth, creating a tight seal
- Blow out as hard and fast as possible until lungs are completely empty
- Repeat for at least 3 acceptable attempts (best two within 200 mL of each other)
- Nose clip may be used to prevent air escape through the nose
- Peak Expiratory Flow Rate (PEFR)
- Measures the fastest rate of airflow during forced expiration
- Used primarily for asthma monitoring at home
- Patients establish a personal best when well-controlled
- Green zone (80-100% of personal best): Good control
- Yellow zone (50-80%): Caution — may need medication adjustment
- Red zone (<50%): Medical alert — seek immediate medical attention
- Other Common Diagnostic Tests
- Holter Monitor
- Continuous ECG recording for 24-48 hours (or longer with extended monitors)
- Purpose: Detect intermittent arrhythmias not captured on a standard ECG
- Patient wears electrodes and a small recording device during normal daily activities
- Patient keeps a diary of activities, symptoms, and times
Medical assistant responsibilities: Apply electrodes, instruct patient on diary use, caution about avoiding water/bathing
- Vision Screening
- Snellen chart : Standard eye chart for distance visual acuity (read at 20 feet)
- 20/20 vision : Normal visual acuity — can read at 20 feet what a normal eye reads at 20 feet
- 20/40 vision : Patient must be at 20 feet to read what a normal eye reads at 40 feet
- Jaeger chart : Near vision testing (reading at 14-16 inches)
- Ishihara plates : Color vision testing (color blindness screening)
- Hearing Screening
- Audiometry : Measures hearing sensitivity at different frequencies and volumes
- Sound measured in decibels (dB) and hertz (Hz)
- Normal hearing: 0-25 dB
- Mild hearing loss: 26-40 dB
- Moderate hearing loss: 41-55 dB
- Tympanometry : Measures middle ear function and eardrum movement
- Additional Diagnostic Procedures
- Allergy Testing
Scratch/prick test : Small amounts of allergens are introduced through superficial skin scratches on the forearm or back
- Intradermal test : Small amount injected into the dermis (more sensitive than scratch test)
- Results : Read at 15-20 minutes; a wheal and flare (redness and swelling) indicates a positive reaction
RAST test : Blood test measuring specific IgE antibodies to allergens (no risk of allergic reaction during testing)
Patient preparation : Discontinue antihistamines 3-7 days before testing; have epinephrine available in case of anaphylaxis
Radiology (X-Ray) Basics
Medical assistants may position patients and prepare equipment but do NOT take X-rays unless specifically trained and licensed
Lead shielding : Always protect reproductive organs and the thyroid when not in the field of view
Pregnancy : X-rays should be avoided unless medically necessary; always ask females of childbearing age about pregnancy status
- Distance : Operator should stand behind the protective barrier during exposure
- Radiation monitoring : Personnel wear dosimetry badges to track cumulative radiation exposure
- Common Lab Panels
Panel Tests Included Purpose
BMP (Basic Metabolic Panel) Glucose, BUN, creatinine, sodium, potassium, chloride, CO2, calcium Kidney function, electrolytes, glucose
CMP (Comprehensive Metabolic Panel) BMP + albumin, total protein, ALP, ALT, AST, bilirubin BMP + liver function
- CBC (Complete Blood Count) RBC, WBC, Hgb, Hct, platelets, differential Blood cell counts, anemia, infection
- Lipid Panel Total cholesterol, LDL, HDL, triglycerides Cardiovascular risk assessment
- Thyroid Panel TSH, T3, T4, free T4 Thyroid function
- Hepatic Panel ALT, AST, ALP, total bilirubin, albumin Liver function
- Coagulation Panel PT, INR, PTT Clotting ability
- Drug Testing (Toxicology)
- Most common specimen: urine (observed or unobserved collection per protocol)
- Chain of custody must be maintained for all forensic/workplace drug testing
Chain of custody documentation includes: specimen collection time, collector identity, all persons handling the specimen, and secure storage
Specimens are sealed with tamper-evident tape and signed by the patient and collector
Confirmatory testing : Immunoassay (screening) followed by GC-MS (gas chromatography-mass spectrometry) for confirmation
Detection windows : Most drugs detectable in urine for 2-4 days; marijuana may be detectable for up to 30 days in heavy users