Study guide
13.1 Myocardial Perfusion Imaging
Certified Nuclear Medicine Technologist CNMT
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 Current CNMT Exam Facts 1.2 How to Use This Guide
2 Radiation Physics Fundamentals
2.1 Radioactive Materials, Isotopes, and Decay Modes 2.2 Decay Calculations and Counting Statistics 2.3 Interactions of Radiation with Matter 2.4 Radiation Detector Types and Principles
3 Biological Effects & ALARA
3.1 Biological Effects of Radiation Exposure 3.2 ALARA and Protection Calculations 3.3 Dose Limits, Surveys, and Personal Monitoring
4 NRC & Regulatory Compliance
4.1 NRC Areas, Spills, Waste, and Records 4.2 Written Directives and DOT Shipping 4.3 EPA, OSHA, HIPAA, FDA, and USP Standards 4.4 Radioactive Waste Disposal and Regulatory Records
5 Generators & Kit Preparation
5.1 Radionuclide Generators and Quality Control 5.2 Radiopharmaceutical Kit Preparation 5.3 Radiopharmaceutical Quality Control
6 Tc-99m Diagnostic Agents
6.1 Tc-99m Cardiac Imaging Agents 6.2 Tc-99m Bone, Renal, and GU Agents 6.3 Tc-99m GI and Hepatobiliary Agents 6.4 Tc-99m CNS, Infection, and Labeled Cells
7 Non-Tc Diagnostic & PET Agents
7.1 Iodine and Indium Diagnostic Agents 7.2 Gallium, Thallium, Xenon, and Miscellaneous Agents 7.3 PET Radiopharmaceuticals 7.4 Neurologic, Breast, and Neuroendocrine PET Agents
8 Therapeutics, Adjuncts & Administration
8.1 Therapeutic Radiopharmaceuticals 8.2 Interventional and Adjunct Pharmaceuticals 8.3 Blood Labeling and Administration Techniques 8.4 Blockade, Comfort, and Gastrointestinal Adjunct Agents
9 Non-Imaging Instrumentation
9.1 Well Counters, Probes, and Survey Meters 9.2 Dose Calibrator Quality Control 9.3 Auxiliary and Patient Care Equipment
10 Imaging Systems & Quality Control
10.1 Gamma Camera Quality Control 10.2 SPECT and SPECT/CT Systems 10.3 PET and PET/CT Systems and QC 10.4 CT Systems, PACS, and Information Systems 10.5 CT Radiation Dose, Safety Alerts, and Protocol Optimization
11 Pulmonary, Bone, Oncology & Infection Imaging
11.1 Pulmonary Imaging Procedures 11.2 Bone and Musculoskeletal Imaging 11.3 Oncology Imaging Procedures 11.4 Infection Imaging Procedures
12 Renal, Endocrine & Hematopoietic Imaging
12.1 Renal and Genitourinary Imaging 12.2 Endocrine Imaging (Thyroid, Parathyroid, Adrenal) 12.3 Hematopoietic and Bone Marrow Imaging 12.4 Thyroid Uptake Measurement and Radioiodine Survey Technique
13 Cardiovascular Procedures
13.1 Myocardial Perfusion Imaging 13.2 Cardiac Function, Viability, and Special Studies 13.3 Exercise and Pharmacologic Stress Testing
14 GI, CNS, Therapy & Hybrid CT Procedures
14.1 Gastrointestinal Procedures 14.2 Central Nervous System Procedures 14.3 Radionuclide Therapy Procedures 14.4 CT and Hybrid Imaging in Nuclear Medicine 14.5 CSF Studies: Cisternography, Leak Localization, and Shunt Patency
15 Patient Care & Clinical Workflow
15.1 Patient Care, Education, and Consent 15.2 Scheduling and Radiopharmaceutical Procurement 15.3 Acquisition, Positioning, and Image Quality 15.4 Image Processing and Quantitative Analysis 15.5 Non-Imaging Studies: Specimens, Counting, and Error Analysis
13.1 Myocardial Perfusion Imaging
Key Takeaways Explain This Topic AI
MPI maps relative myocardial blood flow with Tc-99m sestamibi/tetrofosmin SPECT (± ECG gating, prone, SPECT/CT attenuation) or PET agents Rb-82 and N-13 ammonia
One-day Tc protocols use low rest then high stress (≈3× activity); two-day uses roughly equal high doses; inject at peak exercise or peak pharmacologic hyperemia
Patient prep: NPO as ordered, hold caffeine 12–24 h for vasodilator stress, hold beta blockers for exercise stress when the order requires them
Common artifacts—breast attenuation (anterior/anteroseptal), diaphragmatic (inferior), motion, and LBBB-related septal defects—must be recognized before calling ischemia or scar
Gated SPECT adds wall motion and EF; fixed defect with normal thickening often favors attenuation over true infarct
Last updated: August 2026
13.1 Myocardial Perfusion Imaging
Quick Answer: MPI images relative coronary flow at stress and rest. Tc-99m sestamibi/tetrofosmin SPECT (± gating, prone, SPECT/CT AC) is standard; PET uses Rb-82 or N-13 ammonia . Sequence and dose ratios (one-day low→high vs two-day equal) protect image quality. Prep = NPO , no caffeine 12–24 h for vasodilators, hold β-blockers for exercise when ordered. Flag breast, diaphragm, motion, LBBB artifacts.
Domain V cardiac items test protocol choice , timing , prep , and tech-level artifact recognition —not full cardiologist scoring of every coronary territory.
Clinical Role of MPI
- Indication Teaching point
- Suspected CAD / chest pain Stress–rest patterns support ischemia vs scar
- Known CAD risk stratification Extent/severity of ischemia guides management
- Preoperative cardiac risk Functional capacity plus perfusion when indicated
- Viability adjunct (selected) Rest uptake / PET pathways (see §13.2)
The technologist owns dose, injection timing, positioning, gating, and raw-data QC.
Correlate symptoms, ECG changes, and achieved heart rate or pharmacologic adequacy with the images. A technically perfect scan after a failed stress still underestimates ischemia—document peak HR, symptoms, ST changes, and whether caffeine or β-blockers were held.
Planar vs SPECT MPI
Early MPI used planar multi-view imaging (anterior, LAO, left lateral). Planar is historical foundation and rare fallback; modern practice is SPECT (and hybrid SPECT/CT or PET/CT). Tomography separates overlapping walls that planar cannot.
SPECT MPI: Gated and Non-Gated
After IV injection, wait for blood-pool and hepatobiliary clearance (often ~30–60 min rest , ~15–45 min post-stress ; tetrofosmin often earlier than sestamibi). Acquire SPECT with arms up when tolerated.
- Mode What you get Why it matters
- Non-gated SPECT Perfusion only Use if irregular rhythm prevents gating
- ECG-gated SPECT Perfusion + wall motion , thickening, LVEF Normal motion favors attenuation over infarct
- Supine SPECT Default geometry Breast and diaphragm attenuation common
- Prone SPECT Belly down Often reduces inferior diaphragmatic attenuation
- SPECT/CT SPECT + low-dose CT attenuation correction (AC) Still review non-AC and raw projections
Prone + supine (or AC + non-AC) comparison helps when fixed inferior or anterior defects look artifactual. CT-AC caveats: misregistration from breathing or position change creates false defects—check fused alignment before trusting AC-only slices.
PET Myocardial Perfusion
- Agent Half-life / source Teaching notes
- Rb-82 chloride ≈ 75 s ; Sr-82 generator Rest and stress same session; absolute flow possible
- N-13 ammonia ≈ 10 min ; cyclotron High extraction; needs nearby cyclotron
- O-15 water (selected) Very short; cyclotron Quantitation/research
PET offers higher resolution and routine CT attenuation correction. Stress is usually pharmacologic because of short half-lives. Inject and image on a tight clock—especially Rb-82.
Tc-99m Protocols: One-Day vs Two-Day
Tc-99m agents show minimal clinical redistribution ; separate stress and rest injections are required.
- Protocol Dose pattern (adult order-of-magnitude) Sequencing logic
- One-day rest → stress Rest ~8–12 mCi , stress ~24–36 mCi (≈ 3:1 ) High second dose dominates residual
One-day stress → rest (selected) Stress first then higher rest, or stress-only if normal Lab-specific triage pathways
- Two-day ~20–30 mCi each day (roughly equal) Large patients; avoid same-day residual
- Stress-only (selected low-risk) Single stress ~25–40 mCi class Rest canceled if stress clearly normal
Injection timing: at peak treadmill exercise (continue ~1 min when safe) or at peak pharmacologic hyperemia (during adenosine, after regadenoson bolus, or timed with dipyridamole). Secure IV—extravasation ruins relative counts.
Same-day dual-isotope protocols (historical Tl-201 rest + Tc-99m stress) appear on older exams but are less common now; know that different energies and redistribution properties change processing. For pure Tc one-day work, never invert the high/low ratio without a written protocol reason.
Patient Preparation (High-Yield)
- Prep item Why
- NPO / light meal as ordered Lower GI activity; safer stress
Hold caffeine 12–24 h before adenosine, dipyridamole, regadenoson Caffeine antagonizes A2A hyperemia → false-negative MPI
- Hold β-blockers for exercise when ordered Protects diagnostic heart-rate response
- Other meds per order Document what the patient took
- History: LBBB, paced rhythm, COPD/asthma, caffeine today Chooses modality; predicts artifacts
- Pregnancy screen; IV; coach stillness Safety and motion control
- Common Artifacts and Pitfalls
- Artifact Typical appearance Tech response
- Breast attenuation Fixed anterior/anterolateral Rotating cine; prone or AC; normal gated motion
- Diaphragmatic attenuation Fixed inferior wall Prone, AC, gated thickening
- Motion Cine discontinuities, false defects Repeat; validated motion correction
LBBB / RV paced rhythm Septal changes ± “reversible” look Prefer pharmacologic stress when ordered; document rhythm
Subdiaphragmatic liver/bowel Inferior scatter / normalization error Delay, hydrate, fatty snack, re-image
Review the rotating projection cine on every study before reconstruction sign-off. Truncation, upward creep, and arm-down positioning create defects that look like CAD until the raw data are inspected.
Bottom line: match agent and camera mode to the question, protect dose ratio and injection timing , enforce caffeine and med holds , and review raw projections + gating before calling ischemia or scar.