Study guide

9.3 Auxiliary and Patient Care Equipment

Certified Nuclear Medicine Technologist CNMT

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Exam Overview

1.1 Current CNMT Exam Facts 1.2 How to Use This Guide

2 Radiation Physics Fundamentals

2.1 Radioactive Materials, Isotopes, and Decay Modes 2.2 Decay Calculations and Counting Statistics 2.3 Interactions of Radiation with Matter 2.4 Radiation Detector Types and Principles

3 Biological Effects & ALARA

3.1 Biological Effects of Radiation Exposure 3.2 ALARA and Protection Calculations 3.3 Dose Limits, Surveys, and Personal Monitoring

4 NRC & Regulatory Compliance

4.1 NRC Areas, Spills, Waste, and Records 4.2 Written Directives and DOT Shipping 4.3 EPA, OSHA, HIPAA, FDA, and USP Standards 4.4 Radioactive Waste Disposal and Regulatory Records

5 Generators & Kit Preparation

5.1 Radionuclide Generators and Quality Control 5.2 Radiopharmaceutical Kit Preparation 5.3 Radiopharmaceutical Quality Control

6 Tc-99m Diagnostic Agents

6.1 Tc-99m Cardiac Imaging Agents 6.2 Tc-99m Bone, Renal, and GU Agents 6.3 Tc-99m GI and Hepatobiliary Agents 6.4 Tc-99m CNS, Infection, and Labeled Cells

7 Non-Tc Diagnostic & PET Agents

7.1 Iodine and Indium Diagnostic Agents 7.2 Gallium, Thallium, Xenon, and Miscellaneous Agents 7.3 PET Radiopharmaceuticals 7.4 Neurologic, Breast, and Neuroendocrine PET Agents

8 Therapeutics, Adjuncts & Administration

8.1 Therapeutic Radiopharmaceuticals 8.2 Interventional and Adjunct Pharmaceuticals 8.3 Blood Labeling and Administration Techniques 8.4 Blockade, Comfort, and Gastrointestinal Adjunct Agents

9 Non-Imaging Instrumentation

9.1 Well Counters, Probes, and Survey Meters 9.2 Dose Calibrator Quality Control 9.3 Auxiliary and Patient Care Equipment

10 Imaging Systems & Quality Control

10.1 Gamma Camera Quality Control 10.2 SPECT and SPECT/CT Systems 10.3 PET and PET/CT Systems and QC 10.4 CT Systems, PACS, and Information Systems 10.5 CT Radiation Dose, Safety Alerts, and Protocol Optimization

11 Pulmonary, Bone, Oncology & Infection Imaging

11.1 Pulmonary Imaging Procedures 11.2 Bone and Musculoskeletal Imaging 11.3 Oncology Imaging Procedures 11.4 Infection Imaging Procedures

12 Renal, Endocrine & Hematopoietic Imaging

12.1 Renal and Genitourinary Imaging 12.2 Endocrine Imaging (Thyroid, Parathyroid, Adrenal) 12.3 Hematopoietic and Bone Marrow Imaging 12.4 Thyroid Uptake Measurement and Radioiodine Survey Technique

13 Cardiovascular Procedures

13.1 Myocardial Perfusion Imaging 13.2 Cardiac Function, Viability, and Special Studies 13.3 Exercise and Pharmacologic Stress Testing

14 GI, CNS, Therapy & Hybrid CT Procedures

14.1 Gastrointestinal Procedures 14.2 Central Nervous System Procedures 14.3 Radionuclide Therapy Procedures 14.4 CT and Hybrid Imaging in Nuclear Medicine 14.5 CSF Studies: Cisternography, Leak Localization, and Shunt Patency

15 Patient Care & Clinical Workflow

15.1 Patient Care, Education, and Consent 15.2 Scheduling and Radiopharmaceutical Procurement 15.3 Acquisition, Positioning, and Image Quality 15.4 Image Processing and Quantitative Analysis 15.5 Non-Imaging Studies: Specimens, Counting, and Error Analysis

9.3 Auxiliary and Patient Care Equipment

Key Takeaways Explain This Topic AI

Hot-lab auxiliary equipment (calibrated pipettes, fume hoods/laminar flow as required) supports accurate RP preparation and containment of volatiles and aerosols

Patient-care devices—IV pumps, ECG, pulse oximetry, BP, glucose meters, O₂ delivery, defibrillator, lifts/transfer aids—must be available, functional, and within the technologist’s competence and departmental emergency protocols

Xenon delivery systems require airtight administration and an activated charcoal (or equivalent) trap with saturation monitoring; aerosol systems need tight face seal and contamination control

Exercise treadmills and pharmacologic stress setups integrate with ECG monitoring; crash cart/defibrillator readiness is non-negotiable for stress testing

Rb-82 generators (e.g., Cardiogen-82® systems; Ruby-Fill®/related Rb-82 delivery platforms) require elution QC, infusion system checks, and strict adherence to manufacturer/license procedures for Sr-82/Sr-85 breakthrough

Last updated: August 2026

9.3 Auxiliary and Patient Care Equipment

Quick Answer: Non-imaging Domain IV also covers lab tools , patient monitors and emergency gear , Xe/aerosol delivery , treadmills , LSC , and Rb-82 infusion systems . Your job: correct setup, containment, basic function checks, patient safety, and stop-the-line when equipment fails.

Imaging cameras and dose calibrators do not stand alone. Safe nuclear medicine requires auxiliary devices that prepare doses, care for patients, deliver ventilation agents, and run specialized non-imaging assays.

  • Laboratory Auxiliary Equipment
  • Pipettes and Volume Measurement

Radiopharmacy and blood labeling depend on accurate volumes (kits, QC chromatography, cell labeling).

  • Practice Why it matters
  • Use calibrated micropipettes/syringes per SOP Wrong volume → wrong concentration, failed RCP, bad labels

Match tip type and technique (forward/reverse pipetting as trained) Viscous blood and solvents need correct technique

  • Do not mouth-pipette radioactive or biohazard materials Contamination and exposure risk
  • Document calibration/maintenance when required USP/lab accreditation expectations
  • Fume Hoods and Containment

Chemical fume hoods and specialized radiopharmacy hoods (including laminar-flow or isolator systems where used) protect staff from volatiles (e.g., iodine vapor concerns), aerosols, and chemical fumes.

  • Rule Application
  • Work inside the sash plane Keep contaminants in the hood
  • Maintain required face velocity /certification Annual certification is common
  • Do not block rear vents with clutter Airflow fails silently
  • Use for radioiodine handling and volatile steps as SOP requires Reduces airborne contamination

Trap: Performing volatile iodine work on an open bench because “it will be quick” is an ALARA and regulatory failure.

Patient Care Equipment

Nuclear medicine technologists continuously monitor patients during injections, imaging, and especially stress testing and therapy .

Device Role in NM Tech responsibility (entry-level)

IV pump / infusion devices Controlled pharmacologic stress agents, fluids, some RP infusions Correct drug, concentration, rate, line patency; extravasation watch

ECG monitor Stress testing, gated studies, arrhythmia surveillance Lead placement, readable tracing, recognize when to stop and call for help per protocol

Pulse oximeter Oxygenation during stress, sedation, respiratory compromise Correct probe placement; respond to desaturation

Blood pressure cuff Stress stages, recovery, symptomatic patients Proper cuff size; stage-by-stage measurements

Glucose meter Diabetics before FDG PET or prolonged NPO Verify meter QC when required; know hypo treatment path

Oxygen delivery (cannula, mask) Hypoxemia, ordered O₂ Correct device/flow; fire safety near O₂

Defibrillator / crash cart Cardiac emergencies on stress or in department Know location, code activation, BLS role; do not delay code for imaging

Lifts / transfer aids / stretchers Safe transfers, fall prevention Body mechanics; enough staff; lock wheels

Safety culture: If ECG leads fail, SpO₂ is unreliable, or the defibrillator is missing from the stress lab, fix the line —do not start a treadmill stress “because the camera is free.”

  • Non-Imaging Procedure Equipment
  • Xenon Delivery and Trap

Xe-133 ventilation studies use a closed delivery system: patient breathes xenon for washin/equilibrium/washout while exhaust passes through a charcoal trap (or approved trap) that adsorbs xenon.

  • Checkpoint Why
  • Tight mask/mouthpiece seal Leaks contaminate room air
  • Trap not saturated ; replace per SOP/monitor Saturated trap releases Xe
  • Negative-pressure room / exhaust as required License and ALARA
  • Room survey after study as required Detect residual airborne/surface activity
  • Aerosol Delivery

Tc-99m DTPA aerosol systems nebulize particles for ventilation imaging. Goals: adequate lung deposition, minimal face/hair/room contamination.

Check nebulizer kit integrity and oxygen/air flow per protocol.

Ensure nose clips and tight seal; wipe face after administration if contaminated.

High central airway deposition or room fog suggests technique/equipment problems.

Treadmill and Stress Hardware

Exercise MPI and other stress protocols require a calibrated treadmill (or bicycle), integrated ECG , BP capability, emergency O₂, and immediate access to a defibrillator and crash cart. Technologists coordinate with supervising personnel for test termination criteria (symptoms, ST changes, arrhythmias, patient request).

Liquid Scintillation Counting (LSC)

Liquid scintillation counters detect low-energy beta emitters (e.g., H-3, C-14, and some research/assay applications) by light produced in scintillation cocktail. They are not substitutes for NaI well counters for routine Tc-99m wipes. Know: quench correction concepts at a basic level, cocktail handling as chemical hazard, and that LSC is specialized laboratory equipment with its own QC.

Rb-82 Delivery Systems (Cardiogen-82®, Ruby-Fill®, and Related Platforms)

Rb-82 from Sr-82/Rb-82 generators is infused for PET MPI via manufacturer infusion systems (commonly referenced brand families include Cardiogen-82® generator systems and Ruby-Fill® /associated Rb-82 delivery platforms—know the functions , not marketing trivia).

Responsibility Content

Elution / infusion QC Follow package insert for activity, volume, and Sr-82 / Sr-85 breakthrough limits before patient use

  • System checks Line integrity, waste collection, dose calibrator assay of elution as required
  • Patient safety Correct IV, no extravasation of high-activity PET doses; radiation protection for staff
  • Documentation QC results, patient dose/time, generator status
  • Action on fail Do not infuse if breakthrough or system QC fails; notify RSO/authorized user

Trap: Treating Rb-82 like a unit-dose Tc-99m syringe without generator breakthrough checks.

Integrated Tech Responsibilities

Pre-use checks — power, calibration stickers in date, disposables stocked, emergency equipment present.

Infection control — clean ECG leads, BP cuffs, pulse-ox probes between patients; biohazard handling for blood-labeling gear.

Radiation safety — hoods for volatiles, Xe trap monitoring, aerosol containment, spill kits near use areas.

Competency limits — operate within training; escalate ACLS-level care to qualified responders while initiating BLS/code as trained.

Failure response — broken treadmill, failed xenon trap, out-of-QC Rb-82 system, or nonfunctional defibrillator → cancel or postpone until safe alternatives exist.

Quick Matching Table

  • Need Equipment family
  • Precise kit/blood volumes Calibrated pipettes/syringes
  • Volatile radioiodine work Certified fume hood
  • Xe-133 ventilation Delivery system + charcoal trap
  • DTPA ventilation Nebulizer aerosol system
  • Exercise stress Treadmill + ECG + emergency cart
  • Low-energy beta lab assays Liquid scintillation counter
  • PET Rb-82 MPI Generator infusion system with breakthrough QC
  • Symptomatic patient on table SpO₂, BP, O₂, code activation path

Non-imaging instrumentation mastery is operational safety : the right device, proven to work, used within protocol—every patient, every day.