Study guide
11.1 Pulmonary Imaging Procedures
Certified Nuclear Medicine Technologist CNMT
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 Current CNMT Exam Facts 1.2 How to Use This Guide
2 Radiation Physics Fundamentals
2.1 Radioactive Materials, Isotopes, and Decay Modes 2.2 Decay Calculations and Counting Statistics 2.3 Interactions of Radiation with Matter 2.4 Radiation Detector Types and Principles
3 Biological Effects & ALARA
3.1 Biological Effects of Radiation Exposure 3.2 ALARA and Protection Calculations 3.3 Dose Limits, Surveys, and Personal Monitoring
4 NRC & Regulatory Compliance
4.1 NRC Areas, Spills, Waste, and Records 4.2 Written Directives and DOT Shipping 4.3 EPA, OSHA, HIPAA, FDA, and USP Standards 4.4 Radioactive Waste Disposal and Regulatory Records
5 Generators & Kit Preparation
5.1 Radionuclide Generators and Quality Control 5.2 Radiopharmaceutical Kit Preparation 5.3 Radiopharmaceutical Quality Control
6 Tc-99m Diagnostic Agents
6.1 Tc-99m Cardiac Imaging Agents 6.2 Tc-99m Bone, Renal, and GU Agents 6.3 Tc-99m GI and Hepatobiliary Agents 6.4 Tc-99m CNS, Infection, and Labeled Cells
7 Non-Tc Diagnostic & PET Agents
7.1 Iodine and Indium Diagnostic Agents 7.2 Gallium, Thallium, Xenon, and Miscellaneous Agents 7.3 PET Radiopharmaceuticals 7.4 Neurologic, Breast, and Neuroendocrine PET Agents
8 Therapeutics, Adjuncts & Administration
8.1 Therapeutic Radiopharmaceuticals 8.2 Interventional and Adjunct Pharmaceuticals 8.3 Blood Labeling and Administration Techniques 8.4 Blockade, Comfort, and Gastrointestinal Adjunct Agents
9 Non-Imaging Instrumentation
9.1 Well Counters, Probes, and Survey Meters 9.2 Dose Calibrator Quality Control 9.3 Auxiliary and Patient Care Equipment
10 Imaging Systems & Quality Control
10.1 Gamma Camera Quality Control 10.2 SPECT and SPECT/CT Systems 10.3 PET and PET/CT Systems and QC 10.4 CT Systems, PACS, and Information Systems 10.5 CT Radiation Dose, Safety Alerts, and Protocol Optimization
11 Pulmonary, Bone, Oncology & Infection Imaging
11.1 Pulmonary Imaging Procedures 11.2 Bone and Musculoskeletal Imaging 11.3 Oncology Imaging Procedures 11.4 Infection Imaging Procedures
12 Renal, Endocrine & Hematopoietic Imaging
12.1 Renal and Genitourinary Imaging 12.2 Endocrine Imaging (Thyroid, Parathyroid, Adrenal) 12.3 Hematopoietic and Bone Marrow Imaging 12.4 Thyroid Uptake Measurement and Radioiodine Survey Technique
13 Cardiovascular Procedures
13.1 Myocardial Perfusion Imaging 13.2 Cardiac Function, Viability, and Special Studies 13.3 Exercise and Pharmacologic Stress Testing
14 GI, CNS, Therapy & Hybrid CT Procedures
14.1 Gastrointestinal Procedures 14.2 Central Nervous System Procedures 14.3 Radionuclide Therapy Procedures 14.4 CT and Hybrid Imaging in Nuclear Medicine 14.5 CSF Studies: Cisternography, Leak Localization, and Shunt Patency
15 Patient Care & Clinical Workflow
15.1 Patient Care, Education, and Consent 15.2 Scheduling and Radiopharmaceutical Procurement 15.3 Acquisition, Positioning, and Image Quality 15.4 Image Processing and Quantitative Analysis 15.5 Non-Imaging Studies: Specimens, Counting, and Error Analysis
11.1 Pulmonary Imaging Procedures
Key Takeaways Explain This Topic AI
Lung V/Q pairs ventilation (Xe-133 gas or Tc-99m DTPA aerosol) with perfusion (Tc-99m MAA) to evaluate PE and quantify differential function
MAA traps mechanically in pulmonary arterioles; keep adult particle counts roughly 200,000–700,000 and reduce particles when the vascular bed is limited or right-to-left shunt is suspected
Right-to-left shunt allows MAA to reach systemic organs (brain, kidneys)—reduce particles, obtain delayed whole-body views if ordered, and never ignore shunt risk on the requisition
PIOPED-era teaching still drives tech-level PE protocols: match mismatched perfusion defects to ventilation and chest radiograph findings
Planar V/Q remains common; SPECT and SPECT/CT improve localization and reduce indeterminate studies when available and ordered
Last updated: August 2026
11.1 Pulmonary Imaging Procedures
Quick Answer: Ventilation = Xe-133 gas or Tc-99m DTPA aerosol . Perfusion = Tc-99m MAA capillary blockade. Compare V and Q (planar ± SPECT/SPECT-CT) for PE and quantitation . Control particle number ; reduce particles / caution in R-to-L shunt and reduced pulmonary vascular bed.
Domain V pulmonary items test agent choice , sequence , particle safety , and tech-level PE logic —not full radiologist PIOPED scoring fluency.
Clinical Indications
- Indication Why nuclear medicine
- Suspected PE (often when CTPA contrast is limited) Mismatched V/Q pattern supports PE
- Baseline / pre-op lung quantitation Relative right vs left (and lobar) function before resection
- Chronic thromboembolic disease follow-up Regional perfusion defects over time
- Right-to-left shunt evaluation (selected) Systemic MAA foci after perfusion dose
Correlate with chest radiograph (or CT) from the same clinical episode—interpretation frameworks assume a recent CXR.
- Ventilation: Two Main Approaches
- Tc-99m DTPA Radioaerosol
Tc-99m DTPA is nebulized into a fine aerosol the patient inhales through a closed system with a mouthpiece and nose clips (or mask). Particles deposit on airway and alveolar surfaces roughly proportional to regional ventilation . After adequate counts are collected, the patient is imaged in the same projections later used for perfusion.
- Item Teaching values / notes
- Typical activity loaded Often ~25–40 mCi in the nebulizer (much less reaches the lungs)
- Lung deposited activity Roughly on the order of ~1 mCi class (protocol-dependent)
- Energy 140 keV Tc-99m window
- Strength Same camera settings as perfusion; multi-view planar easy
- Weakness Central airway hotspotting if turbulent flow, COPD, or poor technique; clumping
Tech tips: coach slow deep breathing; keep nebulizer upright and tubing free of kinks; wipe face contamination before imaging; document poor cooperation. Heavy central deposition is technical/pathophysiologic—not a PE map by itself.
Xe-133 Gas Ventilation
Xe-133 is an inert noble gas (soft gamma ~81 keV; physical t½ ≈ 5.2 days). Classic phases:
Single-breath / washin — first inspiration or early washin maps ventilating lung.
Equilibrium — rebreathing mixes gas throughout communicating airspaces.
Washout — room air clearance; trapping (retained activity) suggests obstructive disease.
- Item Teaching notes
- Activity Often ~5–20 mCi inhaled (lab-specific)
- Room control Negative pressure room preferred; charcoal trap on exhaust
Order relative to MAA Often ventilation before perfusion so 81 keV is not swamped by Tc-99m downscatter—follow lab SOP
Trap Saturated charcoal trap → room contamination
Xe washout trapping is a ventilation obstruction clue; do not call it PE alone.
Perfusion: Tc-99m MAA
Tc-99m macroaggregated albumin (MAA) particles (typically ~10–90 µm) lodge temporarily in pulmonary arterioles —mechanical microembolization of a tiny fraction of the bed. Regional counts map regional pulmonary arterial blood flow at injection.
- Parameter Typical adult teaching range
- Activity ~1–5 mCi (37–185 MBq) IV
- Particle number Commonly keep roughly 200,000–700,000 particles per dose
Injection Supine preferred for even distribution; gentle agitation— do not draw blood into syringe and clot particles; inject slowly without filters that strip particles
Imaging Anterior, posterior, laterals, and both posterior obliques (standard six- or eight-view sets per protocol)
Particle Number Limits and Contraindications
Too many particles block an excessive fraction of the vascular bed. Reduce particle number (not necessarily activity alone—adjust concentration/volume per pharmacy) when:
- Known or suspected pulmonary hypertension / severely reduced vascular bed
- Pneumonectomy or major lung resection
- Known or suspected right-to-left shunt (particles bypass lungs → brain, kidneys, thyroid systemic foci)
- Some pediatric protocols (weight-based particles and activity)
Right-to-left shunt caution: MAA is relatively contraindicated or requires markedly reduced particles and careful medical direction. If shunt imaging is intentional, whole-body or brain/kidney views may be ordered after injection. Free Tc or poor MAA QC is a different problem (thyroid/stomach)—know both differentials.
Pregnancy / breastfeeding: follow institutional policy; perfusion-only or reduced-dose protocols may be used when PE must be evaluated.
Planar vs SPECT / SPECT-CT
Planar V/Q remains the workhorse for many PE protocols and is fully testable. SPECT (and SPECT/CT ) improves contrast for segmental defects and anatomic localization; CT portion (low-dose) helps exclude alternative findings and register anatomy. Tech responsibilities: identical positioning between V and Q when possible, motion control, and correct SPECT orbit/matrix per SOP.
V/Q Quantitation
For surgical planning, draw lung ROIs (often geometric mean of anterior and posterior) to report percent contribution of each lung—and sometimes zones/lobes—to total counts. Use perfusion images (and ventilation if ordered) consistently; exclude hot artifacts and ensure no rotation error between projections.
PE Protocols and PIOPED Concepts (Tech Level)
PIOPED (and later refinements) taught probability language based on defect size, number, and V/Q relationship relative to chest x-ray:
- Pattern concept Meaning for PE teaching
- Mismatched perfusion defect (Q defect with normal V, clear CXR) Classic support for PE
- Matched V and Q defect Often airway disease / non-PE
- Triple match (V, Q, and CXR opacity same region) Intermediate / less specific—needs physician criteria
- Normal perfusion Very low likelihood of clinically significant PE
Tech role: acquire complete, labeled views; ensure ventilation and perfusion are comparable; provide CXR availability; flag motion, aerosol hotspots, and injection issues. Do not independently assign final PIOPED category on the exam unless the stem asks a pure pattern definition.
Sequence Cheat Sheet
- Step Action
- 1 Verify indication, pregnancy status, prior lung surgery, shunt risk, CXR
- 2 Perform ventilation (Xe or aerosol) per lab order
- 3 Inject MAA with correct particle count ; image perfusion
- 4 Add SPECT/SPECT-CT if ordered
- 5 Quantitate if ordered; complete worksheets
Memorize MAA = particles + shunt caution , aerosol vs Xe strengths , and mismatch = PE teaching pattern .