7.2 Air Gaps and the Backflow Preventer Family
Colorado Journeyworker Plumber Journeyman Plumber
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Passing the Colorado Journeyworker Plumber Exam
1.1 Exam Blueprint, Format, and the 2024 Code Changeover 1.2 Colorado Licenses, Experience Hours, and Apprentice Supervision 1.3 Permits, Inspections, Blue Tags, and Board Enforcement
2 Chapter 2: General Regulations (IPC Chapter 3)
2.1 Approved Materials, Certification, and General Installation Rules 2.2 Protection of Pipes: Contact, Notching, Shield Plates, and Freezing 2.3 Piping Support, Trenching, Bedding, and Backfill 2.4 Required Tests: Water, Air, and Backflow Assembly Testing
3 Chapter 3: Fixtures and Equipment (IPC Chapter 4)
3.1 Minimum Fixture Counts, Separate Facilities, and Toilet Room Location 3.2 Fixture Clearances, Compartments, and Setting Requirements 3.3 Water Closets, Urinals, Lavatories, Sinks, and Flush Devices 3.4 Showers, Bathtubs, Fixture Fittings, and Scald Protection
4 Chapter 4: Water Heaters (IPC Chapter 5)
4.1 Water Heater Installation, Location, Access, and Clearances 4.2 Relief Valves and Discharge Piping 4.3 Water Heater Pans, Pan Drains, and Storage Tank Requirements 4.4 Thermal Expansion Control and Hot Water Temperature Limits
5 Chapter 5: Water Supply Materials and Installation (IPC Chapter 6)
5.1 Water Service and Distribution Materials, and Sewer Separation 5.2 Joints, Connections, and Dissimilar Materials in Water Piping 5.3 Valves, Shutoffs, and Required Valve Locations
6 Chapter 6: Water Supply Sizing and Pressure (IPC Chapter 6 and Appendix E)
6.1 Pressure Limits, Pressure Reducing Valves, and Water Hammer 6.2 Water Supply Fixture Units and Estimating Demand 6.3 Sizing Water Piping with Appendix E and Table E104.1
7 Chapter 7: Cross-Connection Control and Backflow Prevention (IPC Sections 608-610, Chapter 13)
7.1 Cross-Connection Principles, Backsiphonage, and Backpressure 7.2 Air Gaps and the Backflow Preventer Family 7.3 Applying Backflow Protection to Specific Connections 7.4 Nonpotable Water Systems, Identification, and Reclaimed Water
8 Chapter 8: Sanitary Drainage Materials and Fittings (IPC Chapter 7)
8.1 Sanitary Drainage Materials and Where Each May Be Used 8.2 Drainage Joints, Transitions, and Prohibited Connections 8.3 Fittings for Change of Direction and Drainage Flow Patterns
9 Chapter 9: Sanitary Drainage Sizing (IPC Sections 704, 709-711)
9.1 Drainage Fixture Units and Load Estimation 9.2 Slope of Horizontal Drainage and Installation Rules 9.3 Sizing Building Drains, Building Sewers, and Horizontal Branches 9.4 Stacks, Branch Intervals, and Offsets in Tall Buildings
10 Chapter 10: Cleanouts, Sumps and Below-Sewer Drainage (IPC Sections 708, 712-716)
10.1 Cleanouts, Manholes, and Access Requirements 10.2 Backwater Valves and Fixtures Below the Sewer Level 10.3 Sumps, Sewage Ejectors, and Macerating Toilet Systems 10.4 Building Sewers, Private Disposal, and Special Drainage Conditions
11 Chapter 11: Vent Fundamentals and Terminals (IPC Sections 901-905, 908)
11.1 How Vents Work, Trap Seal Loss, and the One-Inch Rule 11.2 Vent Terminals, Roof Penetrations, and Sidewall Terminations 11.3 Vent Connections, Grade, and the Six-Inch Rules
12 Chapter 12: Vent Types and Sizing (IPC Sections 906-911, 917)
12.1 Individual Vents, Common Vents, and Vents for Stack Offsets 12.2 Trap-to-Vent Distance, Trap Arms, and Fixture Drains 12.3 Sizing Stack Vents, Vent Stacks, Branch Vents, and Headers 12.4 Putting a Vent System Together: A Worked Building
13 Chapter 13: Engineered and Special Venting (IPC Sections 912-916, 918-920)
13.1 Horizontal and Vertical Wet Venting 13.2 Waste Stack Vents, Circuit Vents, and Combination Waste and Vent 13.3 Island Fixture Venting and Air Admittance Valves
14 Chapter 14: Traps, Interceptors and Separators (IPC Chapter 10)
14.1 Fixture Traps, Trap Seals, and Prohibited Trap Types 14.2 Trap Seal Protection, Primers, and Barrier Devices 14.3 Grease Interceptors, Oil Separators, and Solids Interceptors
15 Chapter 15: Indirect and Special Waste (IPC Chapter 8)
15.1 Where Indirect Waste Is Required, and Air Gap Versus Air Break 15.2 Waste Receptors, Hub Drains, and Standpipes 15.3 Special Wastes, Chemical Neutralization, and Health Care Drainage
16 Chapter 16: Storm Drainage (IPC Chapter 11 and Appendix B)
16.1 Storm Drainage Scope, Disposal, and Prohibited Connections 16.2 Storm Drainage Materials, Roof Drains, and Conductors 16.3 Secondary Roof Drains, Scuppers, and Controlled Flow Systems 16.4 Rainfall Rates, Roof Area, and the Flow-Rate Conversion 16.5 Sizing Vertical Conductors, Leaders, and Storm Drains 16.6 Gutters, Subsoil Drains, Building Subdrains, and Storm Sumps
17 Chapter 17: Residential Fire Sprinklers (IRC Section P2904)
17.1 Residential Fire Sprinkler Systems (IRC Section P2904)
18 Chapter 18: Isometric Analysis and Plumbing Calculations
18.1 Reading Plumbing Isometrics and Riser Diagrams 18.2 Analyzing a DWV Isometric for Code Compliance 18.3 Offsets, Travel, and the Plumbing Math the Exam Assumes
7.2 Air Gaps and the Backflow Preventer Family
Key Takeaways Explain This Topic AI
IPC 608.14.1 measures the air gap vertically from the lowest end of the potable water outlet to the flood level rim of the fixture or receptacle it discharges into.
IPC Table 608.16.1 requires a 1-inch air gap away from a wall for fixtures with effective openings not greater than 1/2 inch, and two times the effective opening diameter for openings greater than 1 inch.
IPC 608.14.5 requires pressure vacuum breaker assemblies to be installed with the critical level not less than 12 inches above all downstream piping and outlets.
IPC 608.16.4 requires the critical level of atmospheric-type or pressure-type vacuum breakers to be set not less than 6 inches above the flood level rim of the fixture or device.
IPC 608.14.2 requires the relief opening of a reduced pressure principle assembly to discharge by air gap and be prevented from being submerged.
Last updated: September 2026
The air gap
IPC 608.14.1 : the minimum required air gap shall be measured vertically from the lowest end of a potable water outlet to the flood level rim of the fixture or receptacle into which the outlet discharges. Air gaps comply with ASME A112.1.2 ; air gap fittings comply with ASME A112.1.3 .
An air gap is the only method that cannot fail mechanically. There is no seat to foul, no check to stick, no diaphragm to tear. It is rated for both backsiphonage and backpressure at both low and high hazard . Everything else in Table 608.1 is a compromise made because a physical gap is not practical at that location.
Table 608.16.1 — minimum required air gaps
- Fixture Away from a wall Close to a wall
- Lavatories and other fixtures with effective openings not greater than 1/2 inch 1 inch 1-1/2 inches
Sinks, laundry trays, gooseneck back faucets and other fixtures with effective openings not greater than 3/4 inch 1-1/2 inches 2-1/2 inches
Over-rim bath fillers and other fixtures with effective openings not greater than 1 inch 2 inches 3 inches
Drinking water fountains, single orifice not greater than 7/16 inch , or multiple orifices totaling 0.150 square inch 1 inch 1-1/2 inches
Effective openings greater than 1 inch 2 times the diameter of the effective opening 3 times the diameter of the effective opening
The close to a wall column exists because a nearby vertical surface lets water climb by capillary action and wall-following flow, defeating a gap that would otherwise work. Footnote a defines when the "away from a wall" column applies: walls or obstructions spaced from the nearest inside edge of the spout opening by more than three times the effective opening diameter for a single wall, or more than four times for two intersecting walls.
IPC 608.16.1 adds one limitation: openings and outlets equipped for hose connection shall be protected by means other than an air gap. A hose defeats a gap by definition — you can always lift the end.
Worked air gap
A 2-inch nonpotable fill line discharges into an open tank, with a wall 3 inches from the spout.
Effective opening is greater than 1 inch, so the last row applies.
Is it "close to a wall"? The wall is 3 inches away, and three times the effective opening (2 inches) is 6 inches. Since 3 inches is less than 6 inches, this is the close to a wall case.
Required air gap: 3 times 2 inches = 6 inches , measured vertically from the lowest end of the outlet to the flood level rim.
- The mechanical devices
- Reduced pressure principle backflow prevention assembly (RPZ) — 608.14.2
Two independently acting check valves separated by a relief valve zone held at a pressure lower than the supply. If either check fouls, the relief valve dumps to atmosphere and the zone can never rise to supply pressure.
Standards: ASSE 1013, AWWA C511, CSA B64.4, CSA B64.4.1 . Detector version: ASSE 1047 .
Rated high or low hazard , backpressure or backsiphonage . Sizes 3/8 to 16 inches.
Permitted under continuous pressure .
The relief opening shall discharge by air gap and shall be prevented from being submerged.
IPC 608.15.2.1 Relief port piping : the termination of the piping from the relief port or air gap fitting must discharge to an approved indirect waste receptor or to the outdoors where it will not cause damage or create a nuisance, and the receptor and drainage piping must be sized to drain the maximum discharge flow rate from the relief port as published by the manufacturer . An RPZ dumping 40 gpm into a 2-inch floor drain rated for 20 gpm floods the room.
Double check backflow prevention assembly (DC) — 608.14.7
Two independently acting checks in series, with shutoffs and test cocks.
Standards: ASSE 1015, CSA B64.5, CSA B64.5.1, AWWA C510 . Detector fire protection version: ASSE 1048 .
Rated low hazard only , but handles both backpressure and backsiphonage . Sizes 3/8 to 16 inches.
Capable of operating under continuous pressure .
Pressure vacuum breaker assembly (PVB) — 608.14.5
A spring-loaded air inlet plus a check valve, with shutoffs and test cocks.
Standards: ASSE 1020 or CSA B64.1.2 . Spill-resistant version (SVB): ASSE 1056 or CSA B64.1.3 .
Rated high or low hazard , backsiphonage only . Sizes 1/2 to 2 inches.
Installed with the critical level not less than 12 inches above all downstream piping and outlets.
Shall not be installed where spillage could cause damage to the structure.
Atmospheric vacuum breaker (AVB) — 608.14.6, 608.16.4
A simple float or poppet that opens to atmosphere when supply pressure drops.
Pipe-applied: ASSE 1001 or CSA B64.1.1 . Hose connection types: ASME A112.21.3, ASSE 1011, 1019, 1035, 1052, CSA B64.2 family.
Rated high or low hazard , backsiphonage only .
Critical level set not less than 6 inches above the flood level rim of the fixture or device (608.16.4). Pipe-applied vacuum breakers are installed not less than 6 inches above the flood level rim of the fixture, receptor or device served.
No valve may be installed downstream of an AVB, and it may not be under continuous pressure — the poppet will stick. IPC 608.17.5 states the downstream valve prohibition explicitly for irrigation.
Shall not be installed under exhaust hoods or similar locations containing toxic fumes or vapors (608.16.4).
Deck-mounted and integral vacuum breakers — 608.16.4.1
Approved deck-mounted or equipment-mounted vacuum breakers, and faucets with integral atmospheric vacuum breakers or spill-resistant assemblies, are installed per the manufacturer with the critical level not less than 1 inch above the flood level rim .
Other devices
Device Section Hazard Backflow type Sizes
Backflow preventer with intermediate atmospheric vent (ASSE 1012, 1081, CSA B64.3) 608.14.3 Low Backpressure or backsiphonage 1/4 to 3/4 in
- Dual check backflow preventer (ASSE 1024, CSA B64.6) 608.14.9 Low Backpressure or backsiphonage 1/4 to 1 in
- Chemical dispenser backflow device (ASSE 1055 or air gap fitting) 608.14.8 — — —
Hose connection backflow preventer (ASSE 1052, ASME A112.21.3) Table 608.1 High or low Low head backpressure, rated working pressure, backpressure or backsiphonage 1/2 to 1 in
Hose connection vacuum breaker (ASSE 1011, CSA B64.2) Table 608.1 High or low Low head backpressure or backsiphonage 1/2, 3/4, 1 in
Laboratory faucet backflow preventer (ASSE 1035, CSA B64.7) Table 608.1 High or low Low head backpressure and backsiphonage —
Vacuum breaker wall hydrant, frost-resistant, automatic draining (ASSE 1019) Table 608.1 High or low Low head backpressure or backsiphonage 3/4, 1 in
- Carbonated beverage machine preventer (ASSE 1022) Table 608.1 Low Backpressure or backsiphonage 1/4 to 3/8 in
- Antisiphon fill valve (ASSE 1002) Table 608.1 High Backsiphonage only —
- The barometric loop — 608.14.4
Barometric loops shall precede the point of connection and shall extend vertically to a height of 35 feet . A barometric loop shall only be utilized as an atmospheric-type or pressure-type vacuum breaker .
Thirty-five feet is not arbitrary: it is just above the theoretical maximum height (33.9 feet) that atmospheric pressure can lift a column of water. Above that height, siphonage is physically impossible. It is backsiphonage protection only.
Location and protection of devices
608.15 : access to backflow preventers as specified by the manufacturer's instructions.
608.15.1 : outdoor enclosures for backflow prevention devices comply with ASSE 1060 .
608.15.2 : backflow preventers shall not be located in areas subject to freezing , except where they can be removed by means of unions or are protected from freezing by heat, insulation or both . In Colorado this is a working constraint, not a theoretical one.