Study guide

18.3 Offsets, Travel, and the Plumbing Math the Exam Assumes

Colorado Journeyworker Plumber Journeyman Plumber

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Passing the Colorado Journeyworker Plumber Exam

1.1 Exam Blueprint, Format, and the 2024 Code Changeover 1.2 Colorado Licenses, Experience Hours, and Apprentice Supervision 1.3 Permits, Inspections, Blue Tags, and Board Enforcement

2 Chapter 2: General Regulations (IPC Chapter 3)

2.1 Approved Materials, Certification, and General Installation Rules 2.2 Protection of Pipes: Contact, Notching, Shield Plates, and Freezing 2.3 Piping Support, Trenching, Bedding, and Backfill 2.4 Required Tests: Water, Air, and Backflow Assembly Testing

3 Chapter 3: Fixtures and Equipment (IPC Chapter 4)

3.1 Minimum Fixture Counts, Separate Facilities, and Toilet Room Location 3.2 Fixture Clearances, Compartments, and Setting Requirements 3.3 Water Closets, Urinals, Lavatories, Sinks, and Flush Devices 3.4 Showers, Bathtubs, Fixture Fittings, and Scald Protection

4 Chapter 4: Water Heaters (IPC Chapter 5)

4.1 Water Heater Installation, Location, Access, and Clearances 4.2 Relief Valves and Discharge Piping 4.3 Water Heater Pans, Pan Drains, and Storage Tank Requirements 4.4 Thermal Expansion Control and Hot Water Temperature Limits

5 Chapter 5: Water Supply Materials and Installation (IPC Chapter 6)

5.1 Water Service and Distribution Materials, and Sewer Separation 5.2 Joints, Connections, and Dissimilar Materials in Water Piping 5.3 Valves, Shutoffs, and Required Valve Locations

6 Chapter 6: Water Supply Sizing and Pressure (IPC Chapter 6 and Appendix E)

6.1 Pressure Limits, Pressure Reducing Valves, and Water Hammer 6.2 Water Supply Fixture Units and Estimating Demand 6.3 Sizing Water Piping with Appendix E and Table E104.1

7 Chapter 7: Cross-Connection Control and Backflow Prevention (IPC Sections 608-610, Chapter 13)

7.1 Cross-Connection Principles, Backsiphonage, and Backpressure 7.2 Air Gaps and the Backflow Preventer Family 7.3 Applying Backflow Protection to Specific Connections 7.4 Nonpotable Water Systems, Identification, and Reclaimed Water

8 Chapter 8: Sanitary Drainage Materials and Fittings (IPC Chapter 7)

8.1 Sanitary Drainage Materials and Where Each May Be Used 8.2 Drainage Joints, Transitions, and Prohibited Connections 8.3 Fittings for Change of Direction and Drainage Flow Patterns

9 Chapter 9: Sanitary Drainage Sizing (IPC Sections 704, 709-711)

9.1 Drainage Fixture Units and Load Estimation 9.2 Slope of Horizontal Drainage and Installation Rules 9.3 Sizing Building Drains, Building Sewers, and Horizontal Branches 9.4 Stacks, Branch Intervals, and Offsets in Tall Buildings

10 Chapter 10: Cleanouts, Sumps and Below-Sewer Drainage (IPC Sections 708, 712-716)

10.1 Cleanouts, Manholes, and Access Requirements 10.2 Backwater Valves and Fixtures Below the Sewer Level 10.3 Sumps, Sewage Ejectors, and Macerating Toilet Systems 10.4 Building Sewers, Private Disposal, and Special Drainage Conditions

11 Chapter 11: Vent Fundamentals and Terminals (IPC Sections 901-905, 908)

11.1 How Vents Work, Trap Seal Loss, and the One-Inch Rule 11.2 Vent Terminals, Roof Penetrations, and Sidewall Terminations 11.3 Vent Connections, Grade, and the Six-Inch Rules

12 Chapter 12: Vent Types and Sizing (IPC Sections 906-911, 917)

12.1 Individual Vents, Common Vents, and Vents for Stack Offsets 12.2 Trap-to-Vent Distance, Trap Arms, and Fixture Drains 12.3 Sizing Stack Vents, Vent Stacks, Branch Vents, and Headers 12.4 Putting a Vent System Together: A Worked Building

13 Chapter 13: Engineered and Special Venting (IPC Sections 912-916, 918-920)

13.1 Horizontal and Vertical Wet Venting 13.2 Waste Stack Vents, Circuit Vents, and Combination Waste and Vent 13.3 Island Fixture Venting and Air Admittance Valves

14 Chapter 14: Traps, Interceptors and Separators (IPC Chapter 10)

14.1 Fixture Traps, Trap Seals, and Prohibited Trap Types 14.2 Trap Seal Protection, Primers, and Barrier Devices 14.3 Grease Interceptors, Oil Separators, and Solids Interceptors

15 Chapter 15: Indirect and Special Waste (IPC Chapter 8)

15.1 Where Indirect Waste Is Required, and Air Gap Versus Air Break 15.2 Waste Receptors, Hub Drains, and Standpipes 15.3 Special Wastes, Chemical Neutralization, and Health Care Drainage

16 Chapter 16: Storm Drainage (IPC Chapter 11 and Appendix B)

16.1 Storm Drainage Scope, Disposal, and Prohibited Connections 16.2 Storm Drainage Materials, Roof Drains, and Conductors 16.3 Secondary Roof Drains, Scuppers, and Controlled Flow Systems 16.4 Rainfall Rates, Roof Area, and the Flow-Rate Conversion 16.5 Sizing Vertical Conductors, Leaders, and Storm Drains 16.6 Gutters, Subsoil Drains, Building Subdrains, and Storm Sumps

17 Chapter 17: Residential Fire Sprinklers (IRC Section P2904)

17.1 Residential Fire Sprinkler Systems (IRC Section P2904)

18 Chapter 18: Isometric Analysis and Plumbing Calculations

18.1 Reading Plumbing Isometrics and Riser Diagrams 18.2 Analyzing a DWV Isometric for Code Compliance 18.3 Offsets, Travel, and the Plumbing Math the Exam Assumes

18.3 Offsets, Travel, and the Plumbing Math the Exam Assumes

Key Takeaways Explain This Topic AI

For a 45-degree offset, travel equals the offset multiplied by 1.414 and the run equals the offset multiplied by 1.000.

For a 22-1/2 degree offset, travel equals the offset multiplied by 2.613 and the run equals the offset multiplied by 2.414.

For a 60-degree offset, travel equals the offset multiplied by 1.155 and the run equals the offset multiplied by 0.577.

One pound per square inch of water pressure equals 2.31 feet of head, and one foot of water column equals 0.433 psi.

The volume of water in a pipe in gallons per foot equals 0.0408 multiplied by the square of the inside diameter in inches.

Last updated: September 2026

What the bulletin tells you to memorize

The PSI Candidate Information Bulletin is explicit:

It is your responsibility to know and to be able to use basic plumbing theory formulas since such knowledge may be required to work problems in the job task area of the examination entitled Job Task X: Calculations . Formulas will not be provided to you at the test center and are not allowed in during the test.

An on-screen calculator is provided (Security Procedures). So you will have arithmetic, but not the relationships. Everything below has to be in your head.

Offsets: the geometry

A simple offset moves a pipe sideways while it continues in the same general direction. Three dimensions describe it:

  • Term Definition
  • Offset (set) The perpendicular displacement — how far the pipe moves sideways
  • Travel The length of the diagonal pipe between the two fittings
  • Run (advance) The distance the pipe advances along its original direction while offsetting
  • The fittings form a right triangle in which the offset is the side opposite the fitting angle. fitting
  • /|
  • travel / | offset
  • / |
  • --------+---+----------
  • run
  • Since the offset is opposite the fitting angle A: travel = offset / sin(A)
  • run = travel x cos(A) = offset / tan(A)
  • The constants
  • Fitting Travel = offset x Run = offset x
  • 11-1/4 degrees 5.126 5.027
  • 22-1/2 degrees 2.613 2.414
  • 30 degrees 2.000 1.732
  • 45 degrees 1.414 1.000
  • 60 degrees 1.155 0.577
  • 72 degrees 1.052 0.325

Two anchors make the table easy to reconstruct:

45 degrees is the one everybody knows: 1.414 (the square root of 2) for travel, and 1.000 for run — because at 45 degrees the pipe advances exactly as far as it offsets.

60 degrees gives 1.155 travel and 0.577 run — a steep turn that offsets a lot for very little advance.

And the direction of the pattern: shallower fittings need much more pipe and much more room . A 6-inch offset takes 8.5 inches of travel with 45s and 34.6 inches with 11-1/4s.

Worked simple offsets

Offset of 18 inches with 45-degree fittings:

  • Travel = 18 x 1.414 = 25.45 inches
  • Run = 18 x 1.000 = 18 inches

Offset of 18 inches with 22-1/2 degree fittings:

  • Travel = 18 x 2.613 = 47.03 inches
  • Run = 18 x 2.414 = 43.45 inches

Offset of 18 inches with 60-degree fittings:

  • Travel = 18 x 1.155 = 20.79 inches
  • Run = 18 x 0.577 = 10.39 inches

Same offset, three answers: the 45 needs 25 inches of room along the run, the 22-1/2 needs 43, and the 60 needs only 10.

Working backward

Items often give you the travel and ask for the offset, or give the run and ask for the travel. Divide instead of multiplying:

  • Travel of 30 inches on 45s: offset = 30 / 1.414 = 21.22 inches
  • Run of 24 inches on 22-1/2s: offset = 24 / 2.414 = 9.94 inches , travel = 9.94 x 2.613 = 25.98 inches

Cut length is not travel. Travel is the center-to-center distance between fittings. The pipe you cut is travel minus the take-off of each fitting — the distance from the fitting's center to the end of its socket or hub. Take-offs come from the fitting manufacturer.

Rolling offsets

A rolling offset moves the pipe in two directions at once — up or down and left or right. Solve it in two steps:

Find the true offset with the Pythagorean theorem: true offset = square root of (vertical offset squared + horizontal offset squared)

Apply the ordinary constant to the true offset .

Worked rolling offset

A pipe must rise 12 inches and move 9 inches to the side, using 45-degree fittings.

  • True offset = sqrt(12² + 9²) = sqrt(144 + 81) = sqrt(225) = 15 inches
  • Travel = 15 x 1.414 = 21.21 inches
  • Run = 15 x 1.000 = 15 inches

Recognize the 3-4-5 family (9-12-15) and the first step is instant.

Grade, fall and developed length

  • Relationship Formula
  • Fall slope (in/ft) x run (ft)
  • Slope needed fall (in) / run (ft)
  • Percent slope (inches of fall per foot / 12) x 100

Worked: a 4-inch building drain runs 72 feet at the Table 704.1 minimum of 1/8 inch per foot .

Fall = 0.125 x 72 = 9 inches

Worked in reverse: a sewer must drop 22 inches over 160 feet .

Available slope = 22 / 160 = 0.1375 inch per foot , which exceeds 1/8 (0.125) — a 4-inch or 6-inch line at minimum slope fits.

Pressure and head

The relationships the exam assumes:

  • Relationship Value
  • 1 psi 2.31 feet of head
  • 1 foot of water column 0.433 psi
  • 1 cubic foot of water 7.48 gallons , about 62.4 pounds
  • 1 gallon of water 8.34 pounds

Worked: what pressure is lost rising 40 feet ?

40 x 0.433 = 17.32 psi

Worked: how high will 60 psi lift water?

60 x 2.31 = 138.6 feet

Worked: what is the static pressure at the base of a 10-foot water column — the DWV water test of IPC 312.2?

10 / 2.31 = 4.33 psi

That last one is the arithmetic behind "a 10-foot head" appearing everywhere in Section 312.

Appendix E uses the same relationship in its sizing procedure: deduct 0.5 psi for each foot the highest outlet is above the source. The code rounds 0.433 up to 0.5 as a conservative design allowance.

Pipe volume and area

  • Relationship Formula
  • Circumference pi x diameter = 3.1416 x d
  • Area of a circle pi x d squared / 4 = 0.7854 x d squared
  • Gallons per foot of pipe 0.0408 x d squared , with d the inside diameter in inches
  • Volume of a cylinder area x length
  • The 0.0408 constant is derived, not memorized blindly: area (sq in) = 0.7854 x d squared
  • volume per foot (cu in) = 0.7854 x d squared x 12 = 9.4248 x d squared
  • gallons per foot = 9.4248 x d squared / 231 = 0.0408 x d squared

Worked: how many gallons are in 150 feet of 4-inch pipe?

  • 0.0408 x 4² = 0.0408 x 16 = 0.653 gallons per foot
  • 0.653 x 150 = 97.9 gallons

Worked: what is the circumference of a 6-inch roof drain, for sizing a secondary scupper under IPC 1108.3?

3.1416 x 6 = 18.85 inches of scupper width, at a minimum height of 4 inches.

Storm and supply conversions

  • Relationship Formula Source
  • Storm flow Q (gpm) = 0.0104 x A (sq ft) x R (in/hr) IPC Equation 11-1
  • Vertical wall allowance add one-half the wall area to the roof area IPC 1106.4
  • Flow to drainage fixture units 1 gpm = 2 dfu IPC 709.3
  • Hot and cold wsfu each is three-fourths of the total load Table E103.3(2) footnote a
  • Developed length for water sizing actual length x 1.2 IPC E104.1 step 3
  • Sprinkler room design flow highest single-sprinkler flow x 2 IRC P2904.4.2
  • Grease interceptor, gravity peak flow (gpm) x 30 minutes IPC 1003.3.7
  • Oil separator, garage 6 cu ft first 100 sq ft + 1 cu ft per additional 100 sq ft IPC 1003.4.2.2

High-altitude note The exam is scored on the IPC and IRC; appliance derating belongs to the fuel gas code and is not a scored content area PSI CIB

A calculation drill

  • Problem Answer
  • 24-inch offset with 45s: travel? 24 x 1.414 = 33.94 in
  • 24-inch offset with 22-1/2s: run? 24 x 2.414 = 57.94 in
  • Rolling offset, 8 in up and 6 in over, 45s: travel? sqrt(64+36) = 10; 10 x 1.414 = 14.14 in
  • 3-inch branch, 40 feet, minimum slope: fall? 0.125 x 40 = 5 in
  • Pressure at the base of a 34-foot stack filled with water? 34 x 0.433 = 14.72 psi
  • Gallons in 80 feet of 2-inch pipe? 0.0408 x 4 x 80 = 13.06 gal
  • Denver, 7,500 sq ft roof: storm flow? 0.0104 x 7,500 x 2.4 = 187.2 gpm
  • 12 gpm continuous discharge: dfu? 12 x 2 = 24 dfu
  • Gravity grease interceptor at 30 gpm peak? 30 x 30 = 900 gallons

Loading diagram... Offset geometry and constants