Study guide

6.2 Biological & Chemical Phosphorus Removal (EBPR & Coagulant Precipitation)

Colorado Water/Wastewater Operator Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: State Laws, Regulations & CCWP Certification

1.1 CDPHE CCWP Program & Regulatory Framework (Regulation 100 / 5 CCR 1003-2) 1.2 Facility Classification & Operator in Responsible Charge (ORC) Requirements 1.3 Certification Levels, Education, Experience & Exam Eligibility (Class D-A, Grade 1-4, Class S/T) 1.4 License Renewal, Training Units (TUs) & Mandatory Regulatory Training 1.5 Colorado Primary Drinking Water Regulations (Regulation 11) & Compliance 1.6 Colorado Discharge Permit System (Regulations 61/62), DMRs & Biosolids Reporting

2 Chapter 2: Source Water & Drinking Water Treatment Processes

2.1 Raw Water Sources, High-Altitude Characteristics & Reservoir Quality 2.2 Coagulation Chemistry, Rapid Mixing & Chemical Dosing (Alum, Ferric, Polymers) 2.3 Flocculation & Sedimentation Basin Design, Operation & Settling Zones 2.4 Granular Media Filtration, Backwash Procedures & Turbidity Standards 2.5 Advanced Treatment: Membranes, Softening, GAC/PAC Adsorption & Aeration 2.6 Groundwater Sources, Well Hydraulics, Static and Pumping Levels & Specific Capacity 2.7 Source Water Characteristics, Contaminant Categories & Watershed Protection Plans 2.8 Pretreatment: Presedimentation, Aeration, Algae Control & Taste-and-Odor Management 2.9 Direct, In-Line, Pressure, Cartridge & Diatomaceous Earth Filtration 2.10 Lime-Soda Softening, Ion Exchange & Water Stabilization 2.11 Water Treatment Plant Residuals: Lagoons, Drying Beds, Land Application & Recycle

3 Chapter 3: Disinfection & Chemical Addition

3.1 Chlorine Chemistry: Hypochlorous Acid, Free/Combined Residual & Breakpoint Chlorination 3.2 Disinfection Kinetics, Baffle Factors, T10 & CT Compliance Calculations 3.3 Disinfection Byproducts (TTHMs, HAA5s) & Stage 1/2 DBP Rules 3.4 Alternative Disinfection: Chloramination, Ultraviolet (UV) Light & Chlorine Dioxide 3.5 Corrosion Control, Lead & Copper Rule Revisions (LCRR) & Fluoridation Practices

4 Chapter 4: Water Treatment Plant Equipment, Instrumentation & Maintenance

4.1 Raw Water Intakes, Screening Equipment & Raw Water Pumping 4.2 Chemical Feed Equipment: Feeders, Day Tanks, Carrier Water & Feed-Rate Calibration 4.3 Chlorination Equipment: Gas Systems, Vacuum Regulators, Hypochlorite Storage & Onsite Generation 4.4 Filter Underdrains, Support Gravel, Surface Wash, Air Scour & Filter-to-Waste 4.5 Plant Process Control, SCADA and PLC Systems, Alarm Management & Records of Operation 4.6 Preventive, Corrective and Predictive Maintenance, Work Orders & Asset Management

5 Chapter 5: Wastewater Treatment Principles & Biological Processes

5.1 Preliminary Treatment: Bar Screens, Shredders, Grit Chambers & Flow Equalization 5.2 Primary Clarification, Solids Separation & Scum Removal Mechanics 5.3 Activated Sludge Fundamentals: Aerobic Microbiology, DO Control & Biomass Growth 5.4 Return & Waste Activated Sludge Management (RAS/WAS Operations & Sludge Age) 5.5 Activated Sludge Troubleshooting: Bulking, Nocardia Foaming, Rising Sludge & Pin Floc 5.6 Wastewater Characteristics, Organic and Hydraulic Loading, Diurnal Flow & Septicity 5.7 Activated Sludge Arrangements: Conventional, Complete Mix, Step Feed, Contact Stabilization, Extended Aeration, Oxidation Ditch, SBR & MBR 5.8 Aeration Systems: Blowers, Diffusers, Surface Aerators, Oxygen Transfer & Altitude Effects

6 Chapter 6: Advanced Wastewater Treatment & Solids Management

6.1 Biological Nutrient Removal: Nitrification, Denitrification & Anoxic Zones 6.2 Biological & Chemical Phosphorus Removal (EBPR & Coagulant Precipitation) 6.3 Sludge Thickening, Aerobic & Anaerobic Digestion (Mesophilic/Thermophilic) 6.4 Dewatering Equipment (Centrifuges, Belt Filter Presses) & Biosolids Standards (Reg 64) 6.5 Pond & Lagoon Operations, Trickling Filters & Rotating Biological Contactors (RBCs) 6.6 Secondary Clarification: Overflow and Solids Loading Rates, RAS Rate Setting & Clarifier Diagnostics 6.7 Tertiary Filtration, Effluent Polishing & Wastewater Disinfection with Chlorine, Dechlorination and UV 6.8 Effluent Disposal, Rapid Infiltration Basins, Colorado Water Reuse Law & Regulation 84

7 Chapter 7: Water Distribution Systems

7.1 Distribution Hydraulics, Pressure Zones, Static Head & Friction Headloss 7.2 Finished Water Storage Tanks, Standpipes, Mixing & Water Age Control 7.3 Distribution Piping, Valves (Gate, Butterfly, PRV), Hydrants & Main Flushing 7.4 Cross-Connection Control, Hazard Assessment & Backflow Preventers (RPZ, DCVA, PVB, Air Gap) 7.5 Water Main Installation, Trenching, Repair, Pressure Testing & Disinfection (AWWA C651) 7.6 Network Layout, Pressure Zones, Demand Patterns, Fire Flow & the Hydraulic Grade Line 7.7 Fire Hydrants, Dry Barrel Operation, Fire Flow Testing & Unidirectional Flushing 7.8 Booster Pump Stations, Hydropneumatic Systems, Controls & Surge Protection 7.9 Customer and Master Metering, Meter Sizing, Accuracy Testing, AMR & AMI 7.10 System Mapping, GIS, As-Builts, Operational Analysis & the AWWA Water Audit 7.11 Service Line Installation, Wet Tapping, Curb Stops & the Lead Service Line Inventory 7.12 Leak Detection, District Metered Areas, Minimum Night Flow & Pressure Management 7.13 Storage Facility Inspection, Sanitary Defects, Water Age Control, Cleaning & AWWA C652 Disinfection 7.14 Utility Locating, Colorado 811 Damage Prevention, the APWA Color Code & New Construction Inspection 7.15 Well and Wellhead Maintenance, Sanitary Condition, Rehabilitation & AWWA C654 Disinfection 7.16 Booster Chlorination, Remote Chemical Feed, Chemical Storage, Security & Supply Management 7.17 Distribution Sampling Technique, Chlorine Residual Monitoring & Nitrification Control in Chloraminated Systems

8 Chapter 8: Wastewater Collection Systems

8.1 Gravity Collection Systems: Flow Velocities, Slopes, Pipe Materials & Manholes 8.2 Wastewater Lift Stations: Wet Wells, Submersible Pumps, Level Controls & Force Mains 8.3 Inflow and Infiltration (I&I) Sources, Flow Monitoring, Smoke Testing & CCTV Inspection 8.4 Collection Maintenance: Hydraulic Jetting, Mechanical Rodding & FOG/Root Mitigation 8.5 Sanitary Sewer Overflows (SSOs): Root Causes, Containment, Reporting & Mitigation 8.6 Lift Station Electrical Devices, Level Detection, Telemetry, Gas Detection & Capacity Adjustment 8.7 Lift Station Configurations, Preventive Maintenance, Wet Well Cleaning, Troubleshooting & Emergency Bypass Pumping 8.8 Collection System Rehabilitation: CIPP, Pipe Bursting, Sliplining, Grouting, Manhole Repair & Tap Defects 8.9 Excavation, Hydro Excavation, Bedding and Haunching, Grade Control & Sewer Acceptance Testing 8.10 Collection System Flow Monitoring, Area-Velocity Metering, Weirs and Flumes & Capacity Assessment

9 Chapter 9: Pumps, Motors & Utility Mechanics

9.1 Centrifugal Pumps: Volutes, Impellers, Packing Seals & Mechanical Seals 9.2 Positive Displacement Pumps (Peristaltic, Diaphragm, Progressive Cavity) & Dosing Systems 9.3 Pump Performance Curves, System Head Curves, Cavitation & NPSH Calculations 9.4 Electric Motors (Single/Three Phase), Controls, Variable Frequency Drives (VFDs) & Power 9.5 Flow Meters (Venturi, Magnetic, Ultrasonic), Online Analyzers, PLCs & SCADA Telemetry 9.6 Air Compressors, Conveyors, Hoists and Cranes, Service Piping & Standby Power Generation 9.7 Valve Types and Duties, Air Release and Air-Vacuum Valves, Water Hammer & Surge Control

10 Chapter 10: Laboratory Analysis & Water Quality Monitoring

10.1 Regulatory Sampling Procedures, Chain of Custody, Holding Times & Preservation Techniques 10.2 Physical & Chemical Drinking Water Testing: Turbidity, pH, Alkalinity, Hardness & Chlorine (DPD) 10.3 Wastewater Laboratory Analysis: BOD5, COD, Total Suspended Solids (TSS) & Settleometry 10.4 Microbiological Testing: Total Coliform, E. coli (Colilert, Membrane Filtration) & QA/QC 10.5 Bench-Scale Jar Testing, Coagulant Optimization & Streaming Current Monitoring 10.6 Laboratory Equipment, Calibration and Verification, QA/QC Program & Certified Laboratory Requirements 10.7 Nutrient Series, Metals Sampling, Whole Effluent Toxicity & Electrode Measurements (DO, pH, ORP, H2S)

11 Chapter 11: Operator Mathematics & Applied Calculations

11.1 Core Conversions, Geometric Area, Pipe Volume & Continuous Flow Rate (MGD, GPM, cfs) 11.2 Chemical Dosage, The Standard "Pounds Formula", Active Chemical & Solution Purity 11.3 Hydraulic Retention Time (HRT), Surface Overflow Rate (SOR) & Weir Overflow Rates 11.4 Process Control Calculations: F/M Ratio, MCRT/Solids Retention Time (SRT) & Sludge Volume Index (SVI) 11.5 Distribution Pressure, Static vs Dynamic Head, Water Horsepower & Wire-to-Water Efficiency 11.6 CT Calculations: Baffling Factors, T10, Temperature and pH Corrections & Multi-Segment Compliance

12 Chapter 12: Safety, Emergency Operations & Compliance

12.1 Permit-Required Confined Space (PRCS) Entry, Atmospheric Testing (O2/LEL/H2S/CO) & Rescue 12.2 Control of Hazardous Energy: Lockout/Tagout (LOTO), Arc Flash & Electrical Safety 12.3 Chemical Safety: Chlorine Gas Handling, Ton Cylinders, Sulfur Dioxide, Ammonia & SDS/GHS 12.4 Trenching & Excavation: Soil Classification, Sloping, Shoring, Shielding & Competent Person Rules 12.5 Emergency Action Plans, Security Vulnerability, Spill Containment & CDPHE Tier 1/2/3 Public Notice 12.6 Work Zone Traffic Control, PPE, Fall Protection, Fire Extinguishers, First Aid & Bloodborne Pathogens 12.7 Standard Operating Procedures, Operating Records, Regulatory Reporting, Customer Complaints & Supervisory Duties

6.2 Biological & Chemical Phosphorus Removal (EBPR & Coagulant Precipitation)

Key Takeaways Explain This Topic AI

Enhanced Biological Phosphorus Removal (EBPR) relies on Phosphorus Accumulating Organisms (PAOs) cycling between an anaerobic selector (no DO, no nitrate) and an aerobic zone.

In the anaerobic zone, PAOs assimilate Volatile Fatty Acids (VFAs) and store them as intracellular polyhydroxyalkanoates (PHAs), hydrolyzing cellular polyphosphate bonds and releasing orthophosphate into the liquid.

In the aerobic zone, PAOs metabolize stored PHAs to generate energy, driving luxury phosphorus uptake and accumulating poly-P granules, resulting in WAS containing 4%–8% dry phosphorus.

Chemical phosphorus precipitation uses trivalent metal salts (alum, ferric chloride) with actual operating molar ratios of 1.5:1 to 2.5:1 (Fe/Al to P) due to competing side reactions with natural alkalinity.

Colorado Regulation 85 establishes nutrient discharge limits (such as 1.0 mg/L Total Phosphorus median), while Regulation 31 stream standards drive ultra-low limits (<0.05 mg/L TP) requiring tertiary filtration.

Last updated: August 2026

Phosphorus Removal Processes: Biological Mechanisms & Chemical Coagulation

Phosphorus is the primary limiting nutrient controlling algal blooms and freshwater eutrophication across Colorado's pristine rivers, reservoirs, and mountain watersheds. Excess phosphorus stimulates massive blooms of cyanobacteria, which deplete nocturnal dissolved oxygen, generate cyanotoxins (microcystins), produce taste and odor compounds (geosmin and MIB), and disrupt aquatic life.

Under Colorado Regulation 85 (Nutrients Management Control Regulation / 5 CCR 1002-85) , domestic wastewater treatment facilities with design capacities ≥ 1.0 MGD \ge 1.0\text{ MGD} ≥ 1.0 MGD (or equivalent industrial dischargers) must comply with technology-based effluent limitations, typically establishing a running annual median of 1.0 mg/L Total Phosphorus (TP) 1.0\text{ mg/L Total Phosphorus (TP)} 1.0 mg/L Total Phosphorus (TP) and 15.0 mg/L Total Nitrogen (TN) 15.0\text{ mg/L Total Nitrogen (TN)} 15.0 mg/L Total Nitrogen (TN) . Furthermore, water quality-based effluent limits promulgated under Regulation 31 (The Basic Standards and Methodologies for Surface Water / 5 CCR 1002-31) establish stream-specific phosphorus standards ranging from 0.02 to 0.10 mg/L Total Phosphorus 0.02\text{ to } 0.10\text{ mg/L Total Phosphorus} 0.02 to 0.10 mg/L Total Phosphorus for sensitive lakes and reservoir catchments.

1. Principles of Enhanced Biological Phosphorus Removal (EBPR)

Enhanced Biological Phosphorus Removal (EBPR) harnesses specialized bacteria termed Phosphorus Accumulating Organisms (PAOs) (most notably Candidatus Accumulibacter phosphatis and Tetrasphaera ). In a standard conventional activated sludge process, biomass contains approximately 1.5 % – 2.0 % 1.5\%\text{--}2.0\% 1.5% – 2.0% phosphorus by dry weight (used for cell membranes and nucleic acids). Under the cyclic environmental stress of alternating anaerobic and aerobic zones, PAOs outcompete ordinary heterotrophs and accumulate 4.0 % – 8.0 % 4.0\%\text{--}8.0\% 4.0% – 8.0% phosphorus by dry weight inside their cells as inorganic polyphosphate granules. +-----------------------------------------------------------------------------------------+

  • | EBPR DUAL-PHASE BIOCHEMICAL CYCLE |
  • +-----------------------------------------------------------------------------------------+
  • | 1. ANAEROBIC ZONE (DO = 0.0 mg/L, NO3-N < 0.1 mg/L, ORP < -150 mV) |
  • | • Substrate Uptake: PAOs absorb Volatile Fatty Acids (VFAs, e.g., acetate/propionate)|
  • | • Internal Storage: VFAs converted into Polyhydroxyalkanoates (PHAs / PHB) |
  • | • Energy Source: High-energy intracellular Poly-P bonds are broken (hydrolyzed) |
  • | • Solution Change: Orthophosphate (PO4(3-)) is RELEASED into liquid (P-Release) |
  • | |
  • | 2. AEROBIC ZONE (DO >= 2.0 mg/L, ORP > +100 mV) |
  • | • Metabolism: PAOs oxidize stored intracellular PHAs for growth and energy |
  • | • Luxury Uptake: Excess orthophosphate absorbed from liquid into cells (P-Uptake) |
  • | • Internal Storage: Rebuilds massive intracellular Poly-P volutin granules |
  • | • Permanent Removal:Wasting phosphorus-rich sludge (WAS) containing 4-8% dry weight P|
  • +-----------------------------------------------------------------------------------------+
  • The Anaerobic Phase Mechanics

To establish true anaerobic conditions, the selector zone must be strictly depleted of both dissolved oxygen ( D O = 0.0 mg/L DO = 0.0\text{ mg/L} D O = 0.0 mg/L ) and oxidized nitrogen ( N O 3 - N < 0.1 mg/L NO_3\text{-}N < 0.1\text{ mg/L} N O 3 ​ - N < 0.1 mg/L ), driving the Oxidation-Reduction Potential (ORP) down to − 150 to − 250 mV -150\text{ to } -250\text{ mV} − 150 to − 250 mV :

VFA Uptake & Fermentation : Fermentative bacteria convert complex soluble organic matter in raw sewage into short-chain Volatile Fatty Acids (VFAs) , predominantly acetic acid ( C H 3 C O O H CH_3COOH C H 3 ​ COO H ) and propionic acid ( C H 3 C H 2 C O O H CH_3CH_2COOH C H 3 ​ C H 2 ​ COO H ).

Energy Coupling & Poly-P Hydrolysis : PAOs rapidly absorb VFAs and synthesize Polyhydroxyalkanoates (PHAs) , such as poly- β \beta β -hydroxybutyrate (PHB). To generate the cellular energy (ATP) required for active VFA transport across the cell membrane without external electron acceptors, PAOs hydrolyze intracellular inorganic polyphosphate ( [ P O 4 ] n [PO_4]_n [ P O 4 ​ ] n ​ ) chains.

Phosphorus Release : Orthophosphate ( P O 4 3 − PO_4^{3-} P O 4 3 − ​ ) and associated cations ( M g 2 + , K + , C a 2 + Mg^{2+}, K^+, Ca^{2+} M g 2 + , K + , C a 2 + ) are expelled into the bulk liquid. Consequently, soluble orthophosphate concentrations in the anaerobic zone surge dramatically, often reaching 20 – 50 mg/L P O 4 - P 20\text{--}50\text{ mg/L } PO_4\text{-}P 20 – 50 mg/L P O 4 ​ - P (a phenomenon called P-Release ).

The Aerobic Phase Mechanics

When the mixed liquor flows into the aerobic zone ( D O ≥ 2.0 mg/L DO \ge 2.0\text{ mg/L} D O ≥ 2.0 mg/L ):

PHA Oxidation : PAOs utilize dissolved oxygen to metabolize their stored intracellular PHAs, producing ATP, carbon dioxide, water, and new cellular biomass.

Luxury Phosphorus Uptake : Energized by PHA catabolism, PAOs absorb all the orthophosphate released in the anaerobic zone plus all the background influent phosphorus, polymerizing it back into dense polyphosphate granules (known as luxury uptake ).

Sludge Wasting : Final secondary effluent achieves ultra-low dissolved orthophosphate ( < 0.1 – 0.5 mg/L <0.1\text{--}0.5\text{ mg/L} < 0.1 – 0.5 mg/L ). The accumulated phosphorus is permanently removed from the treatment system by wasting a controlled mass of Waste Activated Sludge (WAS) .

Competing Organisms: Glycogen Accumulating Organisms (GAOs)

Under upset conditions (such as warm wastewater temperatures > 25 ∘ C >25^\circ\text{C} > 2 5 ∘ C or low pH < 6.5 \text{pH} < 6.5 pH < 6.5 ), Glycogen Accumulating Organisms (GAOs) (e.g., Candidatus Competibacter ) can proliferate. GAOs consume available VFAs in the anaerobic zone and store PHAs without storing or releasing polyphosphates. When GAOs outcompete PAOs for VFAs, biological phosphorus removal collapses.

2. EBPR System Configurations

Designing effective EBPR facilities requires strict hydraulic and nitrate isolation to prevent oxidized nitrogen ( N O 3 − NO_3^- N O 3 − ​ ) from entering the anaerobic selector. If nitrate enters the anaerobic zone, denitrifying heterotrophs will consume the available VFAs before PAOs can utilize them, suppressing P-release.

Process Configuration Flow Schematic & Zones Strengths & Operational Vulnerabilities

A/O (Phoredox) Anaerobic → \rightarrow → Aerobic → \rightarrow → Secondary Clarifier Simple two-stage biological P-removal. Designed for non-nitrifying systems. Vulnerable if nitrification occurs because RAS returns nitrate to the anaerobic zone.

A2/O (Anaerobic / Anoxic / Aerobic) Anaerobic → \rightarrow → Anoxic → \rightarrow → Aerobic → \rightarrow → Secondary Clarifier Combined BNR for nitrogen and phosphorus. An internal recycle (IMLR) sends nitrate from aerobic to anoxic zone. Vulnerable if high nitrate is carried in the RAS underflow into the anaerobic zone.

UCT (University of Cape Town) Anaerobic → \rightarrow → Anoxic → \rightarrow → Aerobic → \rightarrow → Secondary Clarifier RAS is recycled directly to the anoxic basin (not anaerobic). An anoxic-to-anaerobic recycle pumps nitrate-free mixed liquor into the anaerobic zone, completely protecting PAOs from nitrate.

Johannesburg (JHB) Pre-Anoxic (RAS) → \rightarrow → Anaerobic → \rightarrow → Anoxic → \rightarrow → Aerobic Incorporates a dedicated pre-anoxic chamber on the RAS line to fully denitrify the RAS before it enters the anaerobic selector basin.

3. Chemical Phosphorus Precipitation

When biological phosphorus removal alone cannot achieve stringent discharge limits (e.g., < 0.5 mg/L <0.5\text{ mg/L} < 0.5 mg/L or < 0.05 mg/L <0.05\text{ mg/L} < 0.05 mg/L ), wastewater plants apply chemical precipitation utilizing multivalent metal salts or lime.

Primary Coagulants & Precipitation Chemistry

Aluminum Sulfate (Alum - A l 2 ( S O 4 ) 3 ⋅ 14 H 2 O Al_2(SO_4)_3 \cdot 14H_2O A l 2 ​ ( S O 4 ​ ) 3 ​ ⋅ 14 H 2 ​ O ): A l 3 + + P O 4 3 − ⟶ A l P O 4 ↓ ( Aluminum Phosphate Precipitate ) Al^{3+} + PO_4^{3-} \longrightarrow AlPO_4\downarrow \quad (\text{Aluminum Phosphate Precipitate}) A l 3 + + P O 4 3 − ​ ⟶ A lP O 4 ​ ↓ ( Aluminum Phosphate Precipitate )

Ferric Chloride ( F e C l 3 FeCl_3 F e C l 3 ​ ): F e 3 + + P O 4 3 − ⟶ F e P O 4 ↓ ( Ferric Phosphate Precipitate ) Fe^{3+} + PO_4^{3-} \longrightarrow FePO_4\downarrow \quad (\text{Ferric Phosphate Precipitate}) F e 3 + + P O 4 3 − ​ ⟶ F e P O 4 ​ ↓ ( Ferric Phosphate Precipitate )

Ferrous Sulfate ( F e S O 4 FeSO_4 F e S O 4 ​ ): Requires dissolved oxygen or alkaline pH to oxidize ferrous iron ( F e 2 + Fe^{2+} F e 2 + ) to ferric iron ( F e 3 + Fe^{3+} F e 3 + ) to precipitate F e P O 4 FePO_4 F e P O 4 ​ or vivianite [ F e 3 ( P O 4 ) 2 ] [Fe_3(PO_4)_2] [ F e 3 ​ ( P O 4 ​ ) 2 ​ ] .

Hydrated Lime ( C a ( O H ) 2 Ca(OH)_2 C a ( O H ) 2 ​ ): Reacts with natural bicarbonate alkalinity to precipitate calcium carbonate, elevating pH above 10.5 10.5 10.5 to precipitate calcium hydroxyapatite: 10 C a 2 + + 6 P O 4 3 − + 2 O H − ⟶ C a 10 ( P O 4 ) 6 ( O H ) 2 ↓ ( Hydroxyapatite ) 10 Ca^{2+} + 6 PO_4^{3-} + 2 OH^- \longrightarrow Ca_{10}(PO_4)_6(OH)_2\downarrow \quad (\text{Hydroxyapatite}) 10 C a 2 + + 6 P O 4 3 − ​ + 2 O H − ⟶ C a 10 ​ ( P O 4 ​ ) 6 ​ ( O H ) 2 ​ ↓ ( Hydroxyapatite ) +-----------------------------------------------------------------------------------------+

  • | THEORETICAL VS. ACTUAL CHEMICAL DOSING REALITIES |
  • +-----------------------------------------------------------------------------------------+
  • | • Stoichiometric Molar Ratio: 1.0 mole Al3+ or Fe3+ per 1.0 mole Phosphorus (1.0 : 1.0)|
  • | • Stoichiometric Mass Ratio: 0.87 lbs Al3+ per lb P | 1.80 lbs Fe3+ per lb P |
  • | (9.6 lbs Alum / lb P) | (5.2 lbs dry FeCl3 / lb P) |
  • | |
  • | • ACTUAL Operating Molar Ratio:1.5 : 1.0 to 2.5 : 1.0 (Fe/Al to P) |
  • | (Side reactions with alkalinity consume metal ions to |
  • | form Al(OH)3 and Fe(OH)3 hydroxide flocs) |
  • | • Ultra-Low Limits (<0.1 mg/L):Actual Molar Ratio surges to 3.0 : 1.0 to 5.0 : 1.0 |
  • +-----------------------------------------------------------------------------------------+
  • Points of Chemical Addition

Pre-Precipitation (Primary Clarifier Influent) : Metal coagulant added ahead of primary settling tanks. Removes up to 50 % – 70 % 50\%\text{--}70\% 50% – 70% of influent phosphorus along with heavy organic BOD solids. Increases primary sludge volume and reduces biological loading to aeration basins, but requires higher chemical doses and may leave insufficient phosphorus for downstream biological synthesis.

Simultaneous Precipitation (Aeration Basin / Secondary Clarifier Feed) : Coagulant is injected directly into the aeration basin discharge or secondary clarifier feed channel. Metal phosphate precipitates co-settle with biological mixed liquor in the secondary clarifier. Highly flexible, requires low capital infrastructure, and captures both chemical and biological flocs.

Post-Precipitation (Tertiary Clarification / Filtration) : Coagulant is injected into secondary effluent ahead of tertiary sand filters, cloth media disc filters, or high-rate ballasted flocculators (e.g., Actiflo / CoMag). Essential for achieving ultra-low effluent phosphorus ( < 0.02 – 0.05 mg/L <0.02\text{--}0.05\text{ mg/L} < 0.02 – 0.05 mg/L ) to meet Colorado Regulation 31 standards.

Operational Impacts of Metal Salt Addition

Alkalinity Consumption : Metal coagulants act as Lewis acids. Alum consumes 0.50 lbs of alkalinity as CaCO 3 per lb of commercial alum 0.50\text{ lbs of alkalinity as } \text{CaCO}_3\text{ per lb of commercial alum} 0.50 lbs of alkalinity as CaCO 3 ​ per lb of commercial alum ; ferric chloride consumes 0.92 lbs of alkalinity as CaCO 3 per lb of dry F e C l 3 0.92\text{ lbs of alkalinity as } \text{CaCO}_3\text{ per lb of dry } FeCl_3 0.92 lbs of alkalinity as CaCO 3 ​ per lb of dry F e C l 3 ​ .

Chemical Sludge Production : Metal coagulant addition increases overall plant sludge generation by 1.5 to 2.5 lbs of total dry solids 1.5\text{ to } 2.5\text{ lbs of total dry solids} 1.5 to 2.5 lbs of total dry solids for every pound of phosphorus removed.

4. Worked Chemical Coagulant Dosing Calculation

A wastewater treatment plant treats a flow of 2.0 MGD 2.0\text{ MGD} 2.0 MGD with a secondary effluent orthophosphate concentration of 4.0 mg/L P O 4 - P 4.0\text{ mg/L } PO_4\text{-}P 4.0 mg/L P O 4 ​ - P . The target discharge limit is 0.5 mg/L P O 4 - P 0.5\text{ mg/L } PO_4\text{-}P 0.5 mg/L P O 4 ​ - P . Jar testing indicates an operating molar ratio of 2.0 moles of F e 3 + per mole of P 2.0\text{ moles of } Fe^{3+}\text{ per mole of } P 2.0 moles of F e 3 + per mole of P using a liquid ferric chloride solution ( F e C l 3 FeCl_3 F e C l 3 ​ ) containing 38 % dry F e C l 3 by weight 38\%\text{ dry } FeCl_3\text{ by weight} 38% dry F e C l 3 ​ by weight with a specific gravity ( S G SG SG ) of 1.38 1.38 1.38 (solution density = 1.38 × 8.34 = 11.51 lbs/gal = 1.38 \times 8.34 = 11.51\text{ lbs/gal} = 1.38 × 8.34 = 11.51 lbs/gal ).

(Atomic weights: F e = 55.85 g/mol Fe = 55.85\text{ g/mol} F e = 55.85 g/mol , P = 30.97 g/mol P = 30.97\text{ g/mol} P = 30.97 g/mol , C l = 35.45 g/mol Cl = 35.45\text{ g/mol} Cl = 35.45 g/mol ; Molecular weight of F e C l 3 = 162.2 g/mol FeCl_3 = 162.2\text{ g/mol} F e C l 3 ​ = 162.2 g/mol )

Step 1: Calculate Mass of Phosphorus to be Removed Δ P = 4.0 mg/L − 0.5 mg/L = 3.5 mg/L P \Delta P = 4.0\text{ mg/L} - 0.5\text{ mg/L} = 3.5\text{ mg/L } P Δ P = 4.0 mg/L − 0.5 mg/L = 3.5 mg/L P Mass of P removed (lbs/day) = 2.0 MGD × 3.5 mg/L × 8.34 = 58.38 lbs/day P \text{Mass of } P \text{ removed (lbs/day)} = 2.0\text{ MGD} \times 3.5\text{ mg/L} \times 8.34 = 58.38\text{ lbs/day } P Mass of P removed (lbs/day) = 2.0 MGD × 3.5 mg/L × 8.34 = 58.38 lbs/day P

Step 2: Calculate Required Dry Mass of Ferric Chloride ( F e C l 3 FeCl_3 F e C l 3 ​ )

At a 1 : 1 1:1 1 : 1 stoichiometric molar ratio: Mass Ratio of F e C l 3 / P = 162.2 g/mol F e C l 3 30.97 g/mol P = 5.237 lbs dry F e C l 3 / lb P \text{Mass Ratio of } FeCl_3 / P = \frac{162.2\text{ g/mol } FeCl_3}{30.97\text{ g/mol } P} = 5.237\text{ lbs dry } FeCl_3 / \text{lb } P Mass Ratio of F e C l 3 ​ / P = 30.97 g/mol P 162.2 g/mol F e C l 3 ​ ​ = 5.237 lbs dry F e C l 3 ​ / lb P

At an operating molar ratio of 2.0 : 1.0 2.0 : 1.0 2.0 : 1.0 : Dry F e C l 3 required (lbs/day) = 58.38 lbs P / day × ( 5.237 × 2.0 ) = 611.47 lbs dry F e C l 3 / day \text{Dry } FeCl_3 \text{ required (lbs/day)} = 58.38\text{ lbs } P / \text{day} \times (5.237 \times 2.0) = 611.47\text{ lbs dry } FeCl_3 / \text{day} Dry F e C l 3 ​ required (lbs/day) = 58.38 lbs P / day × ( 5.237 × 2.0 ) = 611.47 lbs dry F e C l 3 ​ / day

Step 3: Calculate Gallons of Commercial Liquid Ferric Chloride Solution per Day Lbs of active F e C l 3 per gallon = 11.51 lbs/gal × 0.38 = 4.374 lbs active F e C l 3 / gal \text{Lbs of active } FeCl_3 \text{ per gallon} = 11.51\text{ lbs/gal} \times 0.38 = 4.374\text{ lbs active } FeCl_3 / \text{gal} Lbs of active F e C l 3 ​ per gallon = 11.51 lbs/gal × 0.38 = 4.374 lbs active F e C l 3 ​ / gal Feed Rate (gal/day) = 611.47 lbs/day F e C l 3 4.374 lbs/gal = 139.79 gallons/day \text{Feed Rate (gal/day)} = \frac{611.47\text{ lbs/day } FeCl_3}{4.374\text{ lbs/gal}} = 139.79\text{ gallons/day} Feed Rate (gal/day) = 4.374 lbs/gal 611.47 lbs/day F e C l 3 ​ ​ = 139.79 gallons/day Chemical Metering Pump Feed Rate (gal/hr) = 139.79 gal/day 24 hr/day = 5.82 GPH \text{Chemical Metering Pump Feed Rate (gal/hr)} = \frac{139.79\text{ gal/day}}{24\text{ hr/day}} = 5.82\text{ GPH} Chemical Metering Pump Feed Rate (gal/hr) = 24 hr/day 139.79 gal/day ​ = 5.82 GPH

Loading diagram... University of Cape Town (UCT) Enhanced Biological Phosphorus Removal Layout