Study guide
1.6 Colorado Discharge Permit System (Regulations 61/62), DMRs & Biosolids Reporting
Colorado Water/Wastewater Operator Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: State Laws, Regulations & CCWP Certification
1.1 CDPHE CCWP Program & Regulatory Framework (Regulation 100 / 5 CCR 1003-2) 1.2 Facility Classification & Operator in Responsible Charge (ORC) Requirements 1.3 Certification Levels, Education, Experience & Exam Eligibility (Class D-A, Grade 1-4, Class S/T) 1.4 License Renewal, Training Units (TUs) & Mandatory Regulatory Training 1.5 Colorado Primary Drinking Water Regulations (Regulation 11) & Compliance 1.6 Colorado Discharge Permit System (Regulations 61/62), DMRs & Biosolids Reporting
2 Chapter 2: Source Water & Drinking Water Treatment Processes
2.1 Raw Water Sources, High-Altitude Characteristics & Reservoir Quality 2.2 Coagulation Chemistry, Rapid Mixing & Chemical Dosing (Alum, Ferric, Polymers) 2.3 Flocculation & Sedimentation Basin Design, Operation & Settling Zones 2.4 Granular Media Filtration, Backwash Procedures & Turbidity Standards 2.5 Advanced Treatment: Membranes, Softening, GAC/PAC Adsorption & Aeration 2.6 Groundwater Sources, Well Hydraulics, Static and Pumping Levels & Specific Capacity 2.7 Source Water Characteristics, Contaminant Categories & Watershed Protection Plans 2.8 Pretreatment: Presedimentation, Aeration, Algae Control & Taste-and-Odor Management 2.9 Direct, In-Line, Pressure, Cartridge & Diatomaceous Earth Filtration 2.10 Lime-Soda Softening, Ion Exchange & Water Stabilization 2.11 Water Treatment Plant Residuals: Lagoons, Drying Beds, Land Application & Recycle
3 Chapter 3: Disinfection & Chemical Addition
3.1 Chlorine Chemistry: Hypochlorous Acid, Free/Combined Residual & Breakpoint Chlorination 3.2 Disinfection Kinetics, Baffle Factors, T10 & CT Compliance Calculations 3.3 Disinfection Byproducts (TTHMs, HAA5s) & Stage 1/2 DBP Rules 3.4 Alternative Disinfection: Chloramination, Ultraviolet (UV) Light & Chlorine Dioxide 3.5 Corrosion Control, Lead & Copper Rule Revisions (LCRR) & Fluoridation Practices
4 Chapter 4: Water Treatment Plant Equipment, Instrumentation & Maintenance
4.1 Raw Water Intakes, Screening Equipment & Raw Water Pumping 4.2 Chemical Feed Equipment: Feeders, Day Tanks, Carrier Water & Feed-Rate Calibration 4.3 Chlorination Equipment: Gas Systems, Vacuum Regulators, Hypochlorite Storage & Onsite Generation 4.4 Filter Underdrains, Support Gravel, Surface Wash, Air Scour & Filter-to-Waste 4.5 Plant Process Control, SCADA and PLC Systems, Alarm Management & Records of Operation 4.6 Preventive, Corrective and Predictive Maintenance, Work Orders & Asset Management
5 Chapter 5: Wastewater Treatment Principles & Biological Processes
5.1 Preliminary Treatment: Bar Screens, Shredders, Grit Chambers & Flow Equalization 5.2 Primary Clarification, Solids Separation & Scum Removal Mechanics 5.3 Activated Sludge Fundamentals: Aerobic Microbiology, DO Control & Biomass Growth 5.4 Return & Waste Activated Sludge Management (RAS/WAS Operations & Sludge Age) 5.5 Activated Sludge Troubleshooting: Bulking, Nocardia Foaming, Rising Sludge & Pin Floc 5.6 Wastewater Characteristics, Organic and Hydraulic Loading, Diurnal Flow & Septicity 5.7 Activated Sludge Arrangements: Conventional, Complete Mix, Step Feed, Contact Stabilization, Extended Aeration, Oxidation Ditch, SBR & MBR 5.8 Aeration Systems: Blowers, Diffusers, Surface Aerators, Oxygen Transfer & Altitude Effects
6 Chapter 6: Advanced Wastewater Treatment & Solids Management
6.1 Biological Nutrient Removal: Nitrification, Denitrification & Anoxic Zones 6.2 Biological & Chemical Phosphorus Removal (EBPR & Coagulant Precipitation) 6.3 Sludge Thickening, Aerobic & Anaerobic Digestion (Mesophilic/Thermophilic) 6.4 Dewatering Equipment (Centrifuges, Belt Filter Presses) & Biosolids Standards (Reg 64) 6.5 Pond & Lagoon Operations, Trickling Filters & Rotating Biological Contactors (RBCs) 6.6 Secondary Clarification: Overflow and Solids Loading Rates, RAS Rate Setting & Clarifier Diagnostics 6.7 Tertiary Filtration, Effluent Polishing & Wastewater Disinfection with Chlorine, Dechlorination and UV 6.8 Effluent Disposal, Rapid Infiltration Basins, Colorado Water Reuse Law & Regulation 84
7 Chapter 7: Water Distribution Systems
7.1 Distribution Hydraulics, Pressure Zones, Static Head & Friction Headloss 7.2 Finished Water Storage Tanks, Standpipes, Mixing & Water Age Control 7.3 Distribution Piping, Valves (Gate, Butterfly, PRV), Hydrants & Main Flushing 7.4 Cross-Connection Control, Hazard Assessment & Backflow Preventers (RPZ, DCVA, PVB, Air Gap) 7.5 Water Main Installation, Trenching, Repair, Pressure Testing & Disinfection (AWWA C651) 7.6 Network Layout, Pressure Zones, Demand Patterns, Fire Flow & the Hydraulic Grade Line 7.7 Fire Hydrants, Dry Barrel Operation, Fire Flow Testing & Unidirectional Flushing 7.8 Booster Pump Stations, Hydropneumatic Systems, Controls & Surge Protection 7.9 Customer and Master Metering, Meter Sizing, Accuracy Testing, AMR & AMI 7.10 System Mapping, GIS, As-Builts, Operational Analysis & the AWWA Water Audit 7.11 Service Line Installation, Wet Tapping, Curb Stops & the Lead Service Line Inventory 7.12 Leak Detection, District Metered Areas, Minimum Night Flow & Pressure Management 7.13 Storage Facility Inspection, Sanitary Defects, Water Age Control, Cleaning & AWWA C652 Disinfection 7.14 Utility Locating, Colorado 811 Damage Prevention, the APWA Color Code & New Construction Inspection 7.15 Well and Wellhead Maintenance, Sanitary Condition, Rehabilitation & AWWA C654 Disinfection 7.16 Booster Chlorination, Remote Chemical Feed, Chemical Storage, Security & Supply Management 7.17 Distribution Sampling Technique, Chlorine Residual Monitoring & Nitrification Control in Chloraminated Systems
8 Chapter 8: Wastewater Collection Systems
8.1 Gravity Collection Systems: Flow Velocities, Slopes, Pipe Materials & Manholes 8.2 Wastewater Lift Stations: Wet Wells, Submersible Pumps, Level Controls & Force Mains 8.3 Inflow and Infiltration (I&I) Sources, Flow Monitoring, Smoke Testing & CCTV Inspection 8.4 Collection Maintenance: Hydraulic Jetting, Mechanical Rodding & FOG/Root Mitigation 8.5 Sanitary Sewer Overflows (SSOs): Root Causes, Containment, Reporting & Mitigation 8.6 Lift Station Electrical Devices, Level Detection, Telemetry, Gas Detection & Capacity Adjustment 8.7 Lift Station Configurations, Preventive Maintenance, Wet Well Cleaning, Troubleshooting & Emergency Bypass Pumping 8.8 Collection System Rehabilitation: CIPP, Pipe Bursting, Sliplining, Grouting, Manhole Repair & Tap Defects 8.9 Excavation, Hydro Excavation, Bedding and Haunching, Grade Control & Sewer Acceptance Testing 8.10 Collection System Flow Monitoring, Area-Velocity Metering, Weirs and Flumes & Capacity Assessment
9 Chapter 9: Pumps, Motors & Utility Mechanics
9.1 Centrifugal Pumps: Volutes, Impellers, Packing Seals & Mechanical Seals 9.2 Positive Displacement Pumps (Peristaltic, Diaphragm, Progressive Cavity) & Dosing Systems 9.3 Pump Performance Curves, System Head Curves, Cavitation & NPSH Calculations 9.4 Electric Motors (Single/Three Phase), Controls, Variable Frequency Drives (VFDs) & Power 9.5 Flow Meters (Venturi, Magnetic, Ultrasonic), Online Analyzers, PLCs & SCADA Telemetry 9.6 Air Compressors, Conveyors, Hoists and Cranes, Service Piping & Standby Power Generation 9.7 Valve Types and Duties, Air Release and Air-Vacuum Valves, Water Hammer & Surge Control
10 Chapter 10: Laboratory Analysis & Water Quality Monitoring
10.1 Regulatory Sampling Procedures, Chain of Custody, Holding Times & Preservation Techniques 10.2 Physical & Chemical Drinking Water Testing: Turbidity, pH, Alkalinity, Hardness & Chlorine (DPD) 10.3 Wastewater Laboratory Analysis: BOD5, COD, Total Suspended Solids (TSS) & Settleometry 10.4 Microbiological Testing: Total Coliform, E. coli (Colilert, Membrane Filtration) & QA/QC 10.5 Bench-Scale Jar Testing, Coagulant Optimization & Streaming Current Monitoring 10.6 Laboratory Equipment, Calibration and Verification, QA/QC Program & Certified Laboratory Requirements 10.7 Nutrient Series, Metals Sampling, Whole Effluent Toxicity & Electrode Measurements (DO, pH, ORP, H2S)
11 Chapter 11: Operator Mathematics & Applied Calculations
11.1 Core Conversions, Geometric Area, Pipe Volume & Continuous Flow Rate (MGD, GPM, cfs) 11.2 Chemical Dosage, The Standard "Pounds Formula", Active Chemical & Solution Purity 11.3 Hydraulic Retention Time (HRT), Surface Overflow Rate (SOR) & Weir Overflow Rates 11.4 Process Control Calculations: F/M Ratio, MCRT/Solids Retention Time (SRT) & Sludge Volume Index (SVI) 11.5 Distribution Pressure, Static vs Dynamic Head, Water Horsepower & Wire-to-Water Efficiency 11.6 CT Calculations: Baffling Factors, T10, Temperature and pH Corrections & Multi-Segment Compliance
12 Chapter 12: Safety, Emergency Operations & Compliance
12.1 Permit-Required Confined Space (PRCS) Entry, Atmospheric Testing (O2/LEL/H2S/CO) & Rescue 12.2 Control of Hazardous Energy: Lockout/Tagout (LOTO), Arc Flash & Electrical Safety 12.3 Chemical Safety: Chlorine Gas Handling, Ton Cylinders, Sulfur Dioxide, Ammonia & SDS/GHS 12.4 Trenching & Excavation: Soil Classification, Sloping, Shoring, Shielding & Competent Person Rules 12.5 Emergency Action Plans, Security Vulnerability, Spill Containment & CDPHE Tier 1/2/3 Public Notice 12.6 Work Zone Traffic Control, PPE, Fall Protection, Fire Extinguishers, First Aid & Bloodborne Pathogens 12.7 Standard Operating Procedures, Operating Records, Regulatory Reporting, Customer Complaints & Supervisory Duties
1.6 Colorado Discharge Permit System (Regulations 61/62), DMRs & Biosolids Reporting
Key Takeaways Explain This Topic AI
Regulation 61 (5 CCR 1002-61) creates the Colorado Discharge Permit System, the state-delegated NPDES program administered by the CDPHE Water Quality Control Division.
Effluent limits are either technology-based, such as the secondary treatment standard of 30 mg/L BOD5 and TSS as 30-day averages with 85 percent removal, or water-quality-based limits derived from stream standards.
Discharge monitoring reports are submitted electronically through NetDMR and must be signed by a responsible official, with the operator in responsible charge verifying the underlying data.
A permittee must report noncompliance that may endanger health or the environment to the Division within 24 hours by telephone and follow with a written report within five days.
Regulation 64 (5 CCR 1002-64) governs biosolids in Colorado, requiring site approval, metals and pathogen compliance, and an annual report by March 1 for most preparers.
Last updated: August 2026
The Clean Water Act reaches the operator through a permit
A drinking water operator answers to Regulation 11. A wastewater operator answers to a permit . Colorado holds delegated authority from EPA to run the National Pollutant Discharge Elimination System, and the state version is the Colorado Discharge Permit System (CDPS) , created by Regulation 61 (5 CCR 1002-61) . Every domestic and industrial facility that discharges pollutants to state surface waters must hold either an individual CDPS permit or coverage under a general permit.
Two companion regulations set the numbers the permit writer starts from:
Regulation 31 (Basic Standards and Methodologies for Surface Water) establishes statewide criteria and the methodology for deriving standards.
Regulation 38 and the other basin regulations assign use classifications (aquatic life, recreation, water supply, agriculture) and numeric standards to specific stream segments.
Regulation 62 contains the effluent limitations that apply directly to categories of discharges.
Your permit number, your outfall numbers, and the receiving stream segment appear on the permit's first pages. Knowing the segment matters because two identical plants discharging to different segments can carry very different ammonia or metals limits.
Two kinds of effluent limit
Technology-based effluent limits (TBELs) reflect what a properly operated treatment technology can achieve, regardless of the receiving water. For publicly owned treatment works, the federal secondary treatment standard is the familiar baseline:
- Parameter 30-day average 7-day average Removal requirement
- BOD5 (or CBOD5) 30 mg/L (25 mg/L CBOD5) 45 mg/L (40 mg/L CBOD5) at least 85 percent
- Total suspended solids 30 mg/L 45 mg/L at least 85 percent
- pH 6.0 to 9.0 standard units — —
Water-quality-based effluent limits (WQBELs) are calculated backward from the stream standard. The permit writer takes the standard for the segment, applies the low-flow design condition, accounts for available dilution, and derives the end-of-pipe number needed so the standard is met outside the mixing zone . Ammonia, total residual chlorine, metals, temperature, and nutrients are the parameters most often controlled this way. When both a TBEL and a WQBEL exist, the more stringent one becomes the permit limit .
Colorado's Regulation 85 adds nutrient management controls, and many domestic permits now carry total nitrogen and total phosphorus limits or monitoring requirements that drive the biological nutrient removal operation covered later in this guide.
Reading limit types correctly
Daily maximum — the highest single measurement allowed on any day.
7-day (weekly) average — the arithmetic mean of samples taken in a calendar week.
30-day (monthly) average — the arithmetic mean of samples in a calendar month; for bacteria this is usually a geometric mean .
Mass loading (lbs/day) — concentration converted through the pounds formula. A plant can meet a concentration limit and still violate a mass limit if flow rises, which is why operators track both.
Monitoring, records, and discharge monitoring reports
The permit's monitoring table specifies, for each outfall and parameter, the sample type (grab or 24-hour composite), the frequency , and the analytical method . Composite samples are required for most conventional pollutants because they represent the day; grab samples are required for parameters that change or degrade fast — pH, temperature, dissolved oxygen, total residual chlorine, and bacteria.
Discharge monitoring reports (DMRs) are the legal record of compliance. Colorado permittees submit them electronically through NetDMR , generally by the deadline stated in the permit (commonly the 28th day of the month following the monitoring period). A DMR must be signed by a responsible official — a principal executive officer, a ranking elected official, or a duly authorized representative — under a certification that carries penalties for false statement. The operator in responsible charge is the person who verifies that the bench sheets, flow records, and laboratory reports behind the DMR are accurate before it is signed.
Records retention is a permit condition: monitoring records, calibration and maintenance records, original strip chart recordings, and copies of all reports are kept for at least three years , extended automatically if enforcement is pending.
Bypass, upset, and noncompliance reporting
Bypass means intentionally diverting waste streams around any portion of the treatment facility. Bypass is prohibited unless it is unavoidable to prevent loss of life, personal injury, or severe property damage, there is no feasible alternative, and the permittee gives notice — 10 days in advance for an anticipated bypass, and within 24 hours for an unanticipated one.
Upset is an exceptional incident causing unintentional and temporary noncompliance from factors beyond reasonable control. It is an affirmative defense only if the permittee identifies the cause, shows the facility was being operated properly, gives the required 24-hour notice, and takes remedial action.
24-hour reporting. Any noncompliance that may endanger health or the environment — including any unanticipated bypass or upset that exceeds an effluent limit, and violation of a maximum daily limit for a parameter the permit lists for 24-hour reporting — must be reported orally within 24 hours of becoming aware of it, with a written submission within five days .
Sanitary sewer overflows are reported under both the permit and Colorado's spill reporting requirements.
Regulation 64: biosolids
Regulation 64 (5 CCR 1002-64) is Colorado's biosolids rule and implements the federal 40 CFR Part 503 framework. Operators of any facility that treats sewage sludge for land application need to know:
Site approval and notification. Land application sites must be approved by the Division, with buffer distances from residences, surface water, and wells, and notification before application begins.
Metals. Ceiling concentrations and cumulative or annual pollutant loading rates apply to arsenic, cadmium, copper, lead, mercury, molybdenum, nickel, selenium, and zinc.
Pathogen reduction. Class A biosolids meet density limits for fecal coliform or Salmonella and one of the listed alternatives; Class B biosolids meet a fecal coliform geometric mean limit or a Process to Significantly Reduce Pathogens, and carry site restrictions on crop harvest, grazing, and public access.
Vector attraction reduction. At least one of the listed options, most commonly 38 percent volatile solids reduction through digestion.
Annual report. Preparers generally submit an annual biosolids report to the Division by March 1 covering the prior calendar year's quantities, quality, and application sites.
For the exam, connect the pieces: the permit sets the number, the laboratory produces the data, the DMR reports it, and the ORC is accountable for the truth of all three.