Study guide

1.4 License Renewal, Training Units (TUs) & Mandatory Regulatory Training

Colorado Water/Wastewater Operator Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: State Laws, Regulations & CCWP Certification

1.1 CDPHE CCWP Program & Regulatory Framework (Regulation 100 / 5 CCR 1003-2) 1.2 Facility Classification & Operator in Responsible Charge (ORC) Requirements 1.3 Certification Levels, Education, Experience & Exam Eligibility (Class D-A, Grade 1-4, Class S/T) 1.4 License Renewal, Training Units (TUs) & Mandatory Regulatory Training 1.5 Colorado Primary Drinking Water Regulations (Regulation 11) & Compliance 1.6 Colorado Discharge Permit System (Regulations 61/62), DMRs & Biosolids Reporting

2 Chapter 2: Source Water & Drinking Water Treatment Processes

2.1 Raw Water Sources, High-Altitude Characteristics & Reservoir Quality 2.2 Coagulation Chemistry, Rapid Mixing & Chemical Dosing (Alum, Ferric, Polymers) 2.3 Flocculation & Sedimentation Basin Design, Operation & Settling Zones 2.4 Granular Media Filtration, Backwash Procedures & Turbidity Standards 2.5 Advanced Treatment: Membranes, Softening, GAC/PAC Adsorption & Aeration 2.6 Groundwater Sources, Well Hydraulics, Static and Pumping Levels & Specific Capacity 2.7 Source Water Characteristics, Contaminant Categories & Watershed Protection Plans 2.8 Pretreatment: Presedimentation, Aeration, Algae Control & Taste-and-Odor Management 2.9 Direct, In-Line, Pressure, Cartridge & Diatomaceous Earth Filtration 2.10 Lime-Soda Softening, Ion Exchange & Water Stabilization 2.11 Water Treatment Plant Residuals: Lagoons, Drying Beds, Land Application & Recycle

3 Chapter 3: Disinfection & Chemical Addition

3.1 Chlorine Chemistry: Hypochlorous Acid, Free/Combined Residual & Breakpoint Chlorination 3.2 Disinfection Kinetics, Baffle Factors, T10 & CT Compliance Calculations 3.3 Disinfection Byproducts (TTHMs, HAA5s) & Stage 1/2 DBP Rules 3.4 Alternative Disinfection: Chloramination, Ultraviolet (UV) Light & Chlorine Dioxide 3.5 Corrosion Control, Lead & Copper Rule Revisions (LCRR) & Fluoridation Practices

4 Chapter 4: Water Treatment Plant Equipment, Instrumentation & Maintenance

4.1 Raw Water Intakes, Screening Equipment & Raw Water Pumping 4.2 Chemical Feed Equipment: Feeders, Day Tanks, Carrier Water & Feed-Rate Calibration 4.3 Chlorination Equipment: Gas Systems, Vacuum Regulators, Hypochlorite Storage & Onsite Generation 4.4 Filter Underdrains, Support Gravel, Surface Wash, Air Scour & Filter-to-Waste 4.5 Plant Process Control, SCADA and PLC Systems, Alarm Management & Records of Operation 4.6 Preventive, Corrective and Predictive Maintenance, Work Orders & Asset Management

5 Chapter 5: Wastewater Treatment Principles & Biological Processes

5.1 Preliminary Treatment: Bar Screens, Shredders, Grit Chambers & Flow Equalization 5.2 Primary Clarification, Solids Separation & Scum Removal Mechanics 5.3 Activated Sludge Fundamentals: Aerobic Microbiology, DO Control & Biomass Growth 5.4 Return & Waste Activated Sludge Management (RAS/WAS Operations & Sludge Age) 5.5 Activated Sludge Troubleshooting: Bulking, Nocardia Foaming, Rising Sludge & Pin Floc 5.6 Wastewater Characteristics, Organic and Hydraulic Loading, Diurnal Flow & Septicity 5.7 Activated Sludge Arrangements: Conventional, Complete Mix, Step Feed, Contact Stabilization, Extended Aeration, Oxidation Ditch, SBR & MBR 5.8 Aeration Systems: Blowers, Diffusers, Surface Aerators, Oxygen Transfer & Altitude Effects

6 Chapter 6: Advanced Wastewater Treatment & Solids Management

6.1 Biological Nutrient Removal: Nitrification, Denitrification & Anoxic Zones 6.2 Biological & Chemical Phosphorus Removal (EBPR & Coagulant Precipitation) 6.3 Sludge Thickening, Aerobic & Anaerobic Digestion (Mesophilic/Thermophilic) 6.4 Dewatering Equipment (Centrifuges, Belt Filter Presses) & Biosolids Standards (Reg 64) 6.5 Pond & Lagoon Operations, Trickling Filters & Rotating Biological Contactors (RBCs) 6.6 Secondary Clarification: Overflow and Solids Loading Rates, RAS Rate Setting & Clarifier Diagnostics 6.7 Tertiary Filtration, Effluent Polishing & Wastewater Disinfection with Chlorine, Dechlorination and UV 6.8 Effluent Disposal, Rapid Infiltration Basins, Colorado Water Reuse Law & Regulation 84

7 Chapter 7: Water Distribution Systems

7.1 Distribution Hydraulics, Pressure Zones, Static Head & Friction Headloss 7.2 Finished Water Storage Tanks, Standpipes, Mixing & Water Age Control 7.3 Distribution Piping, Valves (Gate, Butterfly, PRV), Hydrants & Main Flushing 7.4 Cross-Connection Control, Hazard Assessment & Backflow Preventers (RPZ, DCVA, PVB, Air Gap) 7.5 Water Main Installation, Trenching, Repair, Pressure Testing & Disinfection (AWWA C651) 7.6 Network Layout, Pressure Zones, Demand Patterns, Fire Flow & the Hydraulic Grade Line 7.7 Fire Hydrants, Dry Barrel Operation, Fire Flow Testing & Unidirectional Flushing 7.8 Booster Pump Stations, Hydropneumatic Systems, Controls & Surge Protection 7.9 Customer and Master Metering, Meter Sizing, Accuracy Testing, AMR & AMI 7.10 System Mapping, GIS, As-Builts, Operational Analysis & the AWWA Water Audit 7.11 Service Line Installation, Wet Tapping, Curb Stops & the Lead Service Line Inventory 7.12 Leak Detection, District Metered Areas, Minimum Night Flow & Pressure Management 7.13 Storage Facility Inspection, Sanitary Defects, Water Age Control, Cleaning & AWWA C652 Disinfection 7.14 Utility Locating, Colorado 811 Damage Prevention, the APWA Color Code & New Construction Inspection 7.15 Well and Wellhead Maintenance, Sanitary Condition, Rehabilitation & AWWA C654 Disinfection 7.16 Booster Chlorination, Remote Chemical Feed, Chemical Storage, Security & Supply Management 7.17 Distribution Sampling Technique, Chlorine Residual Monitoring & Nitrification Control in Chloraminated Systems

8 Chapter 8: Wastewater Collection Systems

8.1 Gravity Collection Systems: Flow Velocities, Slopes, Pipe Materials & Manholes 8.2 Wastewater Lift Stations: Wet Wells, Submersible Pumps, Level Controls & Force Mains 8.3 Inflow and Infiltration (I&I) Sources, Flow Monitoring, Smoke Testing & CCTV Inspection 8.4 Collection Maintenance: Hydraulic Jetting, Mechanical Rodding & FOG/Root Mitigation 8.5 Sanitary Sewer Overflows (SSOs): Root Causes, Containment, Reporting & Mitigation 8.6 Lift Station Electrical Devices, Level Detection, Telemetry, Gas Detection & Capacity Adjustment 8.7 Lift Station Configurations, Preventive Maintenance, Wet Well Cleaning, Troubleshooting & Emergency Bypass Pumping 8.8 Collection System Rehabilitation: CIPP, Pipe Bursting, Sliplining, Grouting, Manhole Repair & Tap Defects 8.9 Excavation, Hydro Excavation, Bedding and Haunching, Grade Control & Sewer Acceptance Testing 8.10 Collection System Flow Monitoring, Area-Velocity Metering, Weirs and Flumes & Capacity Assessment

9 Chapter 9: Pumps, Motors & Utility Mechanics

9.1 Centrifugal Pumps: Volutes, Impellers, Packing Seals & Mechanical Seals 9.2 Positive Displacement Pumps (Peristaltic, Diaphragm, Progressive Cavity) & Dosing Systems 9.3 Pump Performance Curves, System Head Curves, Cavitation & NPSH Calculations 9.4 Electric Motors (Single/Three Phase), Controls, Variable Frequency Drives (VFDs) & Power 9.5 Flow Meters (Venturi, Magnetic, Ultrasonic), Online Analyzers, PLCs & SCADA Telemetry 9.6 Air Compressors, Conveyors, Hoists and Cranes, Service Piping & Standby Power Generation 9.7 Valve Types and Duties, Air Release and Air-Vacuum Valves, Water Hammer & Surge Control

10 Chapter 10: Laboratory Analysis & Water Quality Monitoring

10.1 Regulatory Sampling Procedures, Chain of Custody, Holding Times & Preservation Techniques 10.2 Physical & Chemical Drinking Water Testing: Turbidity, pH, Alkalinity, Hardness & Chlorine (DPD) 10.3 Wastewater Laboratory Analysis: BOD5, COD, Total Suspended Solids (TSS) & Settleometry 10.4 Microbiological Testing: Total Coliform, E. coli (Colilert, Membrane Filtration) & QA/QC 10.5 Bench-Scale Jar Testing, Coagulant Optimization & Streaming Current Monitoring 10.6 Laboratory Equipment, Calibration and Verification, QA/QC Program & Certified Laboratory Requirements 10.7 Nutrient Series, Metals Sampling, Whole Effluent Toxicity & Electrode Measurements (DO, pH, ORP, H2S)

11 Chapter 11: Operator Mathematics & Applied Calculations

11.1 Core Conversions, Geometric Area, Pipe Volume & Continuous Flow Rate (MGD, GPM, cfs) 11.2 Chemical Dosage, The Standard "Pounds Formula", Active Chemical & Solution Purity 11.3 Hydraulic Retention Time (HRT), Surface Overflow Rate (SOR) & Weir Overflow Rates 11.4 Process Control Calculations: F/M Ratio, MCRT/Solids Retention Time (SRT) & Sludge Volume Index (SVI) 11.5 Distribution Pressure, Static vs Dynamic Head, Water Horsepower & Wire-to-Water Efficiency 11.6 CT Calculations: Baffling Factors, T10, Temperature and pH Corrections & Multi-Segment Compliance

12 Chapter 12: Safety, Emergency Operations & Compliance

12.1 Permit-Required Confined Space (PRCS) Entry, Atmospheric Testing (O2/LEL/H2S/CO) & Rescue 12.2 Control of Hazardous Energy: Lockout/Tagout (LOTO), Arc Flash & Electrical Safety 12.3 Chemical Safety: Chlorine Gas Handling, Ton Cylinders, Sulfur Dioxide, Ammonia & SDS/GHS 12.4 Trenching & Excavation: Soil Classification, Sloping, Shoring, Shielding & Competent Person Rules 12.5 Emergency Action Plans, Security Vulnerability, Spill Containment & CDPHE Tier 1/2/3 Public Notice 12.6 Work Zone Traffic Control, PPE, Fall Protection, Fire Extinguishers, First Aid & Bloodborne Pathogens 12.7 Standard Operating Procedures, Operating Records, Regulatory Reporting, Customer Complaints & Supervisory Duties

1.4 License Renewal, Training Units (TUs) & Mandatory Regulatory Training

Key Takeaways Explain This Topic AI

New and renewed certificates are valid three years, and a renewed certificate runs three years from the prior expiration date rather than from the date it is issued.

Training unit requirements are 1.2 for Class T, D, or 1; 1.8 for Class S, C, or 2; 2.4 for Class B or 3; and 3.0 for Class A or 4, with one training unit equal to ten contact hours.

At least 50 percent of renewal training units must be in the specific certificate category being renewed, and units earned during one three-year period may not carry over to the next.

Mandatory regulatory training must be completed before applying, is valid for three years, and CDPHE provides free on-demand drinking water and wastewater MRT courses through Indigo Water Group.

A certificate becomes invalid on its expiration date with no grace period; it may be restored within two years by paying the $85 renewal fee plus a $100 late fee, after which it is automatically revoked.

Last updated: August 2026

The three-year certification lifecycle

Colorado certificates are not permanent. Under Regulation 100, sections 100.15.3 and 100.16 , a new certificate is valid for three years from its effective date , and a renewed certificate is valid for three years from the expiration date of the prior certificate — not from the date the renewal is issued (section 100.16.1). Renewing late therefore does not buy you extra time; it simply costs more.

To renew, section 100.16.2 requires the operator to apply through the CCWP Portal and demonstrate:

Verification of regulatory training course completion as described in section 100.14.5(b), and

The training unit requirements of section 100.16.6.

The $85 renewal application and administration fee (section 100.17.1(c)(iii)) is collected when the application is submitted and is non-refundable.

Training unit quotas by class

A training unit (TU) is defined by contact hours. Section 100.14.6(b)(iii)(A) sets 10 contact hours = 1.0 training unit , and section 100.16.9(d) sets the minimum course duration for any credit at 30 minutes: 1 to 29 minutes earns 0 TUs, 30 to 45 minutes earns 0.05 TUs, and 46 to 60 minutes earns 0.1 TUs.

The section 100.16.7 table is short and heavily tested:

  • Certified operator class Training units required per 3-year cycle Equivalent contact hours
  • Class T 1.2 TUs 12 hours
  • Class D or Class 1 1.2 TUs 12 hours
  • Class S 1.8 TUs 18 hours
  • Class C or Class 2 1.8 TUs 18 hours
  • Class B or Class 3 2.4 TUs 24 hours
  • Class A or Class 4 3.0 TUs 30 hours

Note carefully that Class S sits with Class C and Class 2 at 1.8 TUs , not with Class T and Class D at 1.2. Class S is a hybrid certificate covering both treatment and distribution or both treatment and collection, so the Board assigned it the higher quota. Candidates who mentally group "all the small-system certificates" together get this item wrong.

Category, carry-over, and multiple certificates

Category rule (100.16.6(b) and (c)): at least 50 percent of the TUs used for a renewal must be for courses approved for credit in the specific certificate category being renewed — water treatment, domestic wastewater treatment, industrial wastewater treatment, distribution system, or collection system. Up to 50 percent may come from another category, including supplemental training.

Multiple certificates (100.16.6(e) and (f)): each certificate carries its own TU requirement, but the training units from one course may be applied toward the renewal of more than one certificate . Units may only be used once in each category . An operator holding a Class A water treatment certificate and a Class 4 distribution certificate must satisfy 3.0 TUs for each, and a single qualifying course can count toward both — but the operator must still meet the 50 percent same-category rule for each renewal.

No carry-over (100.16.6(g)): training units are earned during the three-year period the certificate is valid and do not carry over into the next period.

Pre-exam training (100.16.6(i)): a course taken before an upgrade examination that you then pass does not count toward renewing the new, higher certificate. If you take the course and do not pass, it may still be applied to your current certificate.

Teaching credit (100.16.10): an operator who teaches an approved classroom course earns double the approved TUs, once per course approval number per year.

Out-of-state courses (100.16.9(e)): a course not already approved — for example, one taken in another state — can be submitted with the $25 operator-initiated approval fee, and if approved applies only to the operator who requested it.

Core versus supplemental training

Section 100.16.9 divides approved training into two kinds, and the distinction is not "technical versus safety" — it is "directly related to facility operations versus not."

Core training (100.16.9(a) and (b)): courses on topics directly applicable to operations that may affect public health or the environment, or that maintain regulatory compliance. Eligible subjects listed in the rule are: operation and maintenance of facility mechanical systems, electrical equipment, or hydraulics; physical, chemical, or biological treatment; physical, chemical, or biological testing, or disinfection; regulatory compliance; and other relevant topics the Board or its contractor approves.

Supplemental training (100.16.9(c)): courses the Board finds provide useful operator knowledge but are not directly related to water or wastewater facility operation. Supplemental training units may still be used toward renewal, subject to the 50 percent category rule.

The Board or its contractor determines all subject matter relevance, and the searchable catalog of approved courses lives in the CCWP Portal.

Mandatory regulatory training (MRT)

Section 100.14.5(b) requires an approved regulatory training course to be completed before an application is submitted — for initial certification, for an upgrade, and for renewal alike — and each completion is valid for three years .

CDPHE provides the MRT free and on demand through Indigo Water Group . There are separate Drinking Water and Wastewater MRT courses , and the format is a mix of videos, interactive slides, and quizzes. You register with your operator ID number from your CCWP Portal profile so the completion posts to your record. Section 100.16.8 makes an important point about accounting: the training units from the MRT are included in the total TUs required in section 100.16.7, not added on top of them.

Typical MRT subject matter tracks Colorado's regulatory landscape — operator duties under Title 25, Article 9; ORC designation and written operating plans under Regulation 100; drinking water monitoring, assessments, and public notification under Regulation 11; and discharge permit compliance and reporting for wastewater facilities.

  • Expiration, restoration, and automatic revocation Certificate active (3 years)
  • |
  • v [expiration date]
  • INVALID IMMEDIATELY -- there is NO grace period (100.16.3(a))
  • | * May not represent that you hold the certificate
  • | * May not serve as ORC or operate on the expired certificate
  • v
  • Restoration window (up to 2 years after expiration, 100.16.4)
  • | * Apply for renewal, pay $85 renewal + $100 late fee
  • | * Meet MRT and all training unit requirements
  • | * Restored certificate still runs 3 years from the PRIOR expiration date
  • v [more than 2 years expired]
  • AUTOMATIC REVOCATION (100.16.5)
  • * Treated as a NEW applicant
  • * Must meet all initial requirements and pass the sequential exams again

Three consequences of section 100.16.3 are worth memorizing because they are commonly misstated:

A certificate becomes invalid on its expiration date. Regulation 100 contains no 60-day grace period . The day after expiration you are an uncertified person.

You must not represent that you hold the certificate in the category or level of the expired certificate, and no ORC may operate a facility on an expired certificate .

The restoration window is two years , measured from the expiration date. Section 100.16.4(b) confirms a certificate renewed after expiration is still valid only for three years from the prior expiration date , so late renewal shortens your usable cycle.

Section 100.16.6(j) provides one practical accommodation: training taken after the expiration date but before the automatic revocation date may be used to renew the expired certificate, and if those units are not used for that renewal they may be applied to the subsequent one. It is the operator's responsibility to track which units have been used, and using the same credits twice is grounds for disciplinary action, including revocation.

Military service (100.16.2(b)). For an operator in uniformed service as defined by USERRA, certificates are tolled for the duration of service, plus an additional 90-day grace period on return, with discretion for the Board to extend further. No late fees apply to a renewal application filed in conformance with that provision.

Loading diagram... Certificate Renewal, Restoration, and Revocation Timeline