Study guide
2.2 Coagulation Chemistry, Rapid Mixing & Chemical Dosing (Alum, Ferric, Polymers)
Colorado Water/Wastewater Operator Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: State Laws, Regulations & CCWP Certification
1.1 CDPHE CCWP Program & Regulatory Framework (Regulation 100 / 5 CCR 1003-2) 1.2 Facility Classification & Operator in Responsible Charge (ORC) Requirements 1.3 Certification Levels, Education, Experience & Exam Eligibility (Class D-A, Grade 1-4, Class S/T) 1.4 License Renewal, Training Units (TUs) & Mandatory Regulatory Training 1.5 Colorado Primary Drinking Water Regulations (Regulation 11) & Compliance 1.6 Colorado Discharge Permit System (Regulations 61/62), DMRs & Biosolids Reporting
2 Chapter 2: Source Water & Drinking Water Treatment Processes
2.1 Raw Water Sources, High-Altitude Characteristics & Reservoir Quality 2.2 Coagulation Chemistry, Rapid Mixing & Chemical Dosing (Alum, Ferric, Polymers) 2.3 Flocculation & Sedimentation Basin Design, Operation & Settling Zones 2.4 Granular Media Filtration, Backwash Procedures & Turbidity Standards 2.5 Advanced Treatment: Membranes, Softening, GAC/PAC Adsorption & Aeration 2.6 Groundwater Sources, Well Hydraulics, Static and Pumping Levels & Specific Capacity 2.7 Source Water Characteristics, Contaminant Categories & Watershed Protection Plans 2.8 Pretreatment: Presedimentation, Aeration, Algae Control & Taste-and-Odor Management 2.9 Direct, In-Line, Pressure, Cartridge & Diatomaceous Earth Filtration 2.10 Lime-Soda Softening, Ion Exchange & Water Stabilization 2.11 Water Treatment Plant Residuals: Lagoons, Drying Beds, Land Application & Recycle
3 Chapter 3: Disinfection & Chemical Addition
3.1 Chlorine Chemistry: Hypochlorous Acid, Free/Combined Residual & Breakpoint Chlorination 3.2 Disinfection Kinetics, Baffle Factors, T10 & CT Compliance Calculations 3.3 Disinfection Byproducts (TTHMs, HAA5s) & Stage 1/2 DBP Rules 3.4 Alternative Disinfection: Chloramination, Ultraviolet (UV) Light & Chlorine Dioxide 3.5 Corrosion Control, Lead & Copper Rule Revisions (LCRR) & Fluoridation Practices
4 Chapter 4: Water Treatment Plant Equipment, Instrumentation & Maintenance
4.1 Raw Water Intakes, Screening Equipment & Raw Water Pumping 4.2 Chemical Feed Equipment: Feeders, Day Tanks, Carrier Water & Feed-Rate Calibration 4.3 Chlorination Equipment: Gas Systems, Vacuum Regulators, Hypochlorite Storage & Onsite Generation 4.4 Filter Underdrains, Support Gravel, Surface Wash, Air Scour & Filter-to-Waste 4.5 Plant Process Control, SCADA and PLC Systems, Alarm Management & Records of Operation 4.6 Preventive, Corrective and Predictive Maintenance, Work Orders & Asset Management
5 Chapter 5: Wastewater Treatment Principles & Biological Processes
5.1 Preliminary Treatment: Bar Screens, Shredders, Grit Chambers & Flow Equalization 5.2 Primary Clarification, Solids Separation & Scum Removal Mechanics 5.3 Activated Sludge Fundamentals: Aerobic Microbiology, DO Control & Biomass Growth 5.4 Return & Waste Activated Sludge Management (RAS/WAS Operations & Sludge Age) 5.5 Activated Sludge Troubleshooting: Bulking, Nocardia Foaming, Rising Sludge & Pin Floc 5.6 Wastewater Characteristics, Organic and Hydraulic Loading, Diurnal Flow & Septicity 5.7 Activated Sludge Arrangements: Conventional, Complete Mix, Step Feed, Contact Stabilization, Extended Aeration, Oxidation Ditch, SBR & MBR 5.8 Aeration Systems: Blowers, Diffusers, Surface Aerators, Oxygen Transfer & Altitude Effects
6 Chapter 6: Advanced Wastewater Treatment & Solids Management
6.1 Biological Nutrient Removal: Nitrification, Denitrification & Anoxic Zones 6.2 Biological & Chemical Phosphorus Removal (EBPR & Coagulant Precipitation) 6.3 Sludge Thickening, Aerobic & Anaerobic Digestion (Mesophilic/Thermophilic) 6.4 Dewatering Equipment (Centrifuges, Belt Filter Presses) & Biosolids Standards (Reg 64) 6.5 Pond & Lagoon Operations, Trickling Filters & Rotating Biological Contactors (RBCs) 6.6 Secondary Clarification: Overflow and Solids Loading Rates, RAS Rate Setting & Clarifier Diagnostics 6.7 Tertiary Filtration, Effluent Polishing & Wastewater Disinfection with Chlorine, Dechlorination and UV 6.8 Effluent Disposal, Rapid Infiltration Basins, Colorado Water Reuse Law & Regulation 84
7 Chapter 7: Water Distribution Systems
7.1 Distribution Hydraulics, Pressure Zones, Static Head & Friction Headloss 7.2 Finished Water Storage Tanks, Standpipes, Mixing & Water Age Control 7.3 Distribution Piping, Valves (Gate, Butterfly, PRV), Hydrants & Main Flushing 7.4 Cross-Connection Control, Hazard Assessment & Backflow Preventers (RPZ, DCVA, PVB, Air Gap) 7.5 Water Main Installation, Trenching, Repair, Pressure Testing & Disinfection (AWWA C651) 7.6 Network Layout, Pressure Zones, Demand Patterns, Fire Flow & the Hydraulic Grade Line 7.7 Fire Hydrants, Dry Barrel Operation, Fire Flow Testing & Unidirectional Flushing 7.8 Booster Pump Stations, Hydropneumatic Systems, Controls & Surge Protection 7.9 Customer and Master Metering, Meter Sizing, Accuracy Testing, AMR & AMI 7.10 System Mapping, GIS, As-Builts, Operational Analysis & the AWWA Water Audit 7.11 Service Line Installation, Wet Tapping, Curb Stops & the Lead Service Line Inventory 7.12 Leak Detection, District Metered Areas, Minimum Night Flow & Pressure Management 7.13 Storage Facility Inspection, Sanitary Defects, Water Age Control, Cleaning & AWWA C652 Disinfection 7.14 Utility Locating, Colorado 811 Damage Prevention, the APWA Color Code & New Construction Inspection 7.15 Well and Wellhead Maintenance, Sanitary Condition, Rehabilitation & AWWA C654 Disinfection 7.16 Booster Chlorination, Remote Chemical Feed, Chemical Storage, Security & Supply Management 7.17 Distribution Sampling Technique, Chlorine Residual Monitoring & Nitrification Control in Chloraminated Systems
8 Chapter 8: Wastewater Collection Systems
8.1 Gravity Collection Systems: Flow Velocities, Slopes, Pipe Materials & Manholes 8.2 Wastewater Lift Stations: Wet Wells, Submersible Pumps, Level Controls & Force Mains 8.3 Inflow and Infiltration (I&I) Sources, Flow Monitoring, Smoke Testing & CCTV Inspection 8.4 Collection Maintenance: Hydraulic Jetting, Mechanical Rodding & FOG/Root Mitigation 8.5 Sanitary Sewer Overflows (SSOs): Root Causes, Containment, Reporting & Mitigation 8.6 Lift Station Electrical Devices, Level Detection, Telemetry, Gas Detection & Capacity Adjustment 8.7 Lift Station Configurations, Preventive Maintenance, Wet Well Cleaning, Troubleshooting & Emergency Bypass Pumping 8.8 Collection System Rehabilitation: CIPP, Pipe Bursting, Sliplining, Grouting, Manhole Repair & Tap Defects 8.9 Excavation, Hydro Excavation, Bedding and Haunching, Grade Control & Sewer Acceptance Testing 8.10 Collection System Flow Monitoring, Area-Velocity Metering, Weirs and Flumes & Capacity Assessment
9 Chapter 9: Pumps, Motors & Utility Mechanics
9.1 Centrifugal Pumps: Volutes, Impellers, Packing Seals & Mechanical Seals 9.2 Positive Displacement Pumps (Peristaltic, Diaphragm, Progressive Cavity) & Dosing Systems 9.3 Pump Performance Curves, System Head Curves, Cavitation & NPSH Calculations 9.4 Electric Motors (Single/Three Phase), Controls, Variable Frequency Drives (VFDs) & Power 9.5 Flow Meters (Venturi, Magnetic, Ultrasonic), Online Analyzers, PLCs & SCADA Telemetry 9.6 Air Compressors, Conveyors, Hoists and Cranes, Service Piping & Standby Power Generation 9.7 Valve Types and Duties, Air Release and Air-Vacuum Valves, Water Hammer & Surge Control
10 Chapter 10: Laboratory Analysis & Water Quality Monitoring
10.1 Regulatory Sampling Procedures, Chain of Custody, Holding Times & Preservation Techniques 10.2 Physical & Chemical Drinking Water Testing: Turbidity, pH, Alkalinity, Hardness & Chlorine (DPD) 10.3 Wastewater Laboratory Analysis: BOD5, COD, Total Suspended Solids (TSS) & Settleometry 10.4 Microbiological Testing: Total Coliform, E. coli (Colilert, Membrane Filtration) & QA/QC 10.5 Bench-Scale Jar Testing, Coagulant Optimization & Streaming Current Monitoring 10.6 Laboratory Equipment, Calibration and Verification, QA/QC Program & Certified Laboratory Requirements 10.7 Nutrient Series, Metals Sampling, Whole Effluent Toxicity & Electrode Measurements (DO, pH, ORP, H2S)
11 Chapter 11: Operator Mathematics & Applied Calculations
11.1 Core Conversions, Geometric Area, Pipe Volume & Continuous Flow Rate (MGD, GPM, cfs) 11.2 Chemical Dosage, The Standard "Pounds Formula", Active Chemical & Solution Purity 11.3 Hydraulic Retention Time (HRT), Surface Overflow Rate (SOR) & Weir Overflow Rates 11.4 Process Control Calculations: F/M Ratio, MCRT/Solids Retention Time (SRT) & Sludge Volume Index (SVI) 11.5 Distribution Pressure, Static vs Dynamic Head, Water Horsepower & Wire-to-Water Efficiency 11.6 CT Calculations: Baffling Factors, T10, Temperature and pH Corrections & Multi-Segment Compliance
12 Chapter 12: Safety, Emergency Operations & Compliance
12.1 Permit-Required Confined Space (PRCS) Entry, Atmospheric Testing (O2/LEL/H2S/CO) & Rescue 12.2 Control of Hazardous Energy: Lockout/Tagout (LOTO), Arc Flash & Electrical Safety 12.3 Chemical Safety: Chlorine Gas Handling, Ton Cylinders, Sulfur Dioxide, Ammonia & SDS/GHS 12.4 Trenching & Excavation: Soil Classification, Sloping, Shoring, Shielding & Competent Person Rules 12.5 Emergency Action Plans, Security Vulnerability, Spill Containment & CDPHE Tier 1/2/3 Public Notice 12.6 Work Zone Traffic Control, PPE, Fall Protection, Fire Extinguishers, First Aid & Bloodborne Pathogens 12.7 Standard Operating Procedures, Operating Records, Regulatory Reporting, Customer Complaints & Supervisory Duties
2.2 Coagulation Chemistry, Rapid Mixing & Chemical Dosing (Alum, Ferric, Polymers)
Key Takeaways Explain This Topic AI
Natural colloidal particles (0.001–1.0 μm) possess negative surface charges and stable electric double layers with negative zeta potentials (-15 to -30 mV) that repel each other.
Coagulation destabilizes colloids in seconds via charge neutralization (compressing the double layer) and sweep flocculation (enmeshment in amorphous metal hydroxide precipitates).
Alum addition consumes natural alkalinity at a stoichiometric ratio of approximately 0.45–0.50 mg/L as CaCO3 per 1.0 mg/L of alum, driving low-alkalinity alpine water into acidic pH ranges without supplemental base.
Rapid mixing requires violent hydraulic or mechanical agitation with high velocity gradients (G = 700–1000 s^-1) and brief detention times (<1 to 30 seconds) to disperse coagulants before hydrolysis completes.
Overdosing cationic or anionic polymers can cause charge reversal and steric hindrance, restabilizing colloidal suspensions and severely blinding downstream filter media.
Last updated: August 2026
Coagulation Chemistry, Rapid Mixing & Chemical Dosing
Coagulation is the foundational chemical unit process in conventional and direct surface water treatment. Natural raw water contains colloidal suspensions that cannot settle by gravity within reasonable operational timeframes. A certified water treatment operator must master the electrokinetic forces governing colloidal stability, the chemical behavior of primary coagulants and polymer aids, and the precise mechanical and hydraulic parameters required for rapid mixing.
1. Colloidal Suspensions and Electrokinetic Theory
Turbidity, natural organic matter (NOM), humic acids, and microscopic clays exist in natural water as colloidal particles ranging in diameter from 0.001 to 1.0 micrometers (μm) .
Because of their minute mass and massive surface-area-to-mass ratio, gravitational forces are negligible compared to surface electrokinetic forces. A 0.1 μm clay colloid would require hundreds of years to settle just one foot through quiescent water.
The Electrical Double Layer and Zeta Potential
Colloids in natural surface waters carry a net negative surface electrical charge . This negative surface charge develops from isomorphic substitution in mineral lattices, ionization of surface carboxyl and hydroxyl functional groups on organic matter, and preferential adsorption of natural anions. +-------------------------------------------------------------+
- | THE ELECTRICAL DOUBLE LAYER |
- | |
- | [ Colloid Surface (-) ] |
- | | STERN LAYER (Bound Cations + + + + +) |
- | |---- SLIPPING PLANE / SHEAR PLANE <-- Zeta Potential |
- | | DIFFUSE LAYER (+ - + - + + - + -) |
- | v |
- | BULK SOLUTION (Electroneutral Bulk Water) |
- +-------------------------------------------------------------+
Stern Layer : A rigidly held, compact layer of positively charged counter-ions (cations) attracted to the negative particle surface.
Diffuse Layer : A surrounding outer zone where positive cations outnumber anions, but ion concentration gradually transitions to match the bulk solution.
Slipping Plane (Plane of Shear) : The boundary where the liquid moves with the particle relative to the bulk water.
Zeta Potential (ZP) : The measurable electrical potential (voltage) at the slipping plane, expressed in millivolts (mV). In stable natural waters, zeta potential ranges between -15 mV and -30 mV . This negative electrical potential generates electrostatic repulsive forces that exceed the attractive van der Waals forces , preventing particles from colliding and agglomerating.
Primary Coagulation Mechanisms
Coagulation achieves destabilization through four primary physical-chemical mechanisms:
Charge Neutralization : Highly charged trivalent cations ( Al 3 + \text{Al}^{3+} Al 3 + , Fe 3 + \text{Fe}^{3+} Fe 3 + ) adsorb specifically onto the negative colloid surface, compressing the electrical double layer and reducing the zeta potential toward neutral ( -5 to 0 mV ). Van der Waals attraction then dominates upon contact.
Enmeshment in a Precipitate (Sweep Flocculation) : When metal coagulants are added in concentrations exceeding the solubility limit of the metal hydroxide at pH 6.5–8.0, amorphous precipitates [ Al(OH) 3 (s) [\text{Al(OH)}_3\text{(s)} [ Al(OH) 3 (s) or Fe(OH) 3 (s) ] \text{Fe(OH)}_3\text{(s)}] Fe(OH) 3 (s) ] rapidly form. Colloidal particles are physically trapped ("swept") within the settling sticky mass.
Interparticle Polymer Bridging : Long-chain synthetic polymer molecules attach simultaneously to multiple colloidal particles, forming physical molecular bridges.
Double-Layer Compression : High concentrations of inert electrolytes in the bulk solution reduce the physical thickness of the diffuse layer without specific adsorption.
2. Primary Coagulants and Reaction Chemistry
The most widely utilized primary coagulants in drinking water treatment are aluminum- and iron-based metallic salts.
Aluminum Sulfate (Alum)
Commercial dry alum has the chemical formula Al 2 ( SO 4 ) 3 ⋅ 14 H 2 O \text{Al}_2(\text{SO}_4)_3 \cdot 14\text{H}_2\text{O} Al 2 ( SO 4 ) 3 ⋅ 14 H 2 O (molecular weight ≈ 594 g/mol \approx 594\text{ g/mol} ≈ 594 g/mol ). Liquid alum is delivered as an approximate 48.5% solution (containing approximately 5.4 lbs of dry alum per gallon of solution, or 8.3% active Al 2 O 3 \text{Al}_2\text{O}_3 Al 2 O 3 ).
When added to water containing natural calcium bicarbonate alkalinity, alum reacts according to the following stoichiometric relationship: Al 2 ( SO 4 ) 3 ⋅ 14 H 2 O + 3 Ca ( HCO 3 ) 2 ⟶ 2 Al ( OH ) 3 ↓ + 3 CaSO 4 + 6 CO 2 ↑ + 14 H 2 O \text{Al}_2(\text{SO}_4)_3 \cdot 14\text{H}_2\text{O} + 3\text{Ca}(\text{HCO}_3)_2 \longrightarrow 2\text{Al}(\text{OH})_3\downarrow + 3\text{CaSO}_4 + 6\text{CO}_2\uparrow + 14\text{H}_2\text{O} Al 2 ( SO 4 ) 3 ⋅ 14 H 2 O + 3 Ca ( HCO 3 ) 2 ⟶ 2 Al ( OH ) 3 ↓ + 3 CaSO 4 + 6 CO 2 ↑ + 14 H 2 O
Optimal Coagulation pH Range : 5.8 to 7.5
Alkalinity Consumption : Every 1.0 mg/L of commercial alum fed consumes approximately 0.45 to 0.50 mg/L of natural alkalinity (expressed as CaCO 3 \text{CaCO}_3 CaCO 3 ) .
Carbon Dioxide Generation : The reaction releases dissolved free carbon dioxide ( CO 2 \text{CO}_2 CO 2 ), which further lowers water pH.
Ferric Chloride and Ferric Sulfate
Ferric Chloride ( FeCl 3 \text{FeCl}_3 FeCl 3 ) : Delivered as a dark brown, highly acidic liquid (35–45% strength, pH < 1.0).
Ferric Sulfate [ Fe 2 ( SO 4 ) 3 \text{Fe}_2(\text{SO}_4)_3 Fe 2 ( SO 4 ) 3 ] : Commercial liquid or granular iron coagulant. FeCl 3 + 3 H 2 O ⟶ Fe ( OH ) 3 ↓ + 3 H + + 3 Cl − \text{FeCl}_3 + 3\text{H}_2\text{O} \longrightarrow \text{Fe}(\text{OH})_3\downarrow + 3\text{H}^+ + 3\text{Cl}^- FeCl 3 + 3 H 2 O ⟶ Fe ( OH ) 3 ↓ + 3 H + + 3 Cl − 3 H + + 3 HCO 3 − ⟶ 3 CO 2 + 3 H 2 O 3\text{H}^+ + 3\text{HCO}_3^- \longrightarrow 3\text{CO}_2 + 3\text{H}_2\text{O} 3 H + + 3 HCO 3 − ⟶ 3 CO 2 + 3 H 2 O
Optimal Coagulation pH Range : 4.0 to 11.0 (exceptionally broad operating window compared to alum).
Alkalinity Consumption : Every 1.0 mg/L of ferric chloride consumes approximately 0.92 mg/L of alkalinity as CaCO 3 \text{CaCO}_3 CaCO 3 .
Operating Advantages : Forms heavier, denser ferric hydroxide floc that settles faster than alum floc in cold high-altitude water. Does not leave residual dissolved aluminum in finished water.
Disadvantages : Extremely corrosive to feed lines, pump heads, and concrete; produces yellow/brown stains if overdosed or poorly mixed.
Polyaluminum Chloride (PACl) and Aluminum Chlorohydrate (ACH)
PACl coagulants are pre-hydrolyzed inorganic aluminum polymers with the general formula Al n Cl ( 3 n − m ) ( OH ) m \text{Al}_n\text{Cl}_{(3n-m)}(\text{OH})_m Al n Cl ( 3 n − m ) ( OH ) m .
Pre-Neutralized : PACl contains engineered polymeric aluminum species (such as the Al 13 \text{Al}_{13} Al 13 tridecamer cation AlO 4 Al 12 ( OH ) 24 ( H 2 O ) 12 7 + \text{AlO}_4\text{Al}_{12}(\text{OH})_{24}(\text{H}_2\text{O})_{12}^{7+} AlO 4 Al 12 ( OH ) 24 ( H 2 O ) 12 7 + ) with high cationic charge density.
Minimal Alkalinity Destruction : Consumes 50% to 80% less natural alkalinity than standard alum.
Superior Cold-Water Performance : Because hydrolysis has already taken place during manufacturing, PACl forms robust, rapidly settling floc in cold mountain runoff ( < 4 ∘ C <4^\circ\text{C} < 4 ∘ C ) without requiring supplemental base dosing.
3. Coagulant Aids and Polymers
Coagulant aids (polyelectrolytes) are high-molecular-weight synthetic organic compounds composed of repeating acrylamide or amine monomer units.
Polymer Class Electrical Charge Primary Function Operational Role & Dosing Guidelines
Cationic Positive ( + + + ) Charge Neutralization / Primary Aid Low molecular weight, high charge density. Reduces required metal coagulant dose; effective at 0.1–2.0 mg/L.
Anionic Negative ( − - − ) Flocculant Aid (Bridging) High molecular weight. Added downstream of rapid mix to bind positive micro-flocs into large, tough macro-flocs (0.01–0.2 mg/L).
Nonionic Neutral ( 0 0 0 ) Flocculant Aid (Bridging) High molecular weight. Provides structural matrix for interparticle bridging across dense mineral silts (0.01–0.2 mg/L).
CRITICAL OPERATING WARNING: Polymer Overdosing Overdosing polymers is a severe operational error. Excessive cationic polymer reverses colloidal charge (making particles positive), causing charge restabilization . Overdosing long-chain flocculant aids causes steric hindrance (polymer coats particle surfaces, leaving no open attachment sites) and creates sticky, viscous residues that rapidly bind and permanently blind granular filter media, causing rapid headloss accumulation.
4. Chemical Dosing Calculations and Alkalinity Balancing
Maintaining adequate buffering capacity post-coagulation is mandatory to prevent acidic, highly corrosive finished water. Plants must maintain a minimum finished water alkalinity of 20 to 30 mg/L as CaCO 3 \text{CaCO}_3 CaCO 3 .
Standard Chemical Feed Formula (The Pounds Formula) Chemical Feed (lb/day) = Flow (MGD) × Dosage (mg/L) × 8.34 lb/gal \text{Chemical Feed (lb/day)} = \text{Flow (MGD)} \times \text{Dosage (mg/L)} \times 8.34\text{ lb/gal} Chemical Feed (lb/day) = Flow (MGD) × Dosage (mg/L) × 8.34 lb/gal Commercial Product (lb/day) = Pure Chemical Feed (lb/day) Active Strength (Decimal Fraction) \text{Commercial Product (lb/day)} = \frac{\text{Pure Chemical Feed (lb/day)}}{\text{Active Strength (Decimal Fraction)}} Commercial Product (lb/day) = Active Strength (Decimal Fraction) Pure Chemical Feed (lb/day)
Worked Example: Alum Dosing and Alkalinity Supplementation
A Colorado conventional water treatment plant treats a spring snowmelt flow of 4.0 MGD . The raw water has a natural alkalinity of 18.0 mg/L as CaCO 3 \text{CaCO}_3 CaCO 3 . Jar testing indicates an optimal alum dose of 28.0 mg/L . The plant standard requires maintaining at least 25.0 mg/L residual alkalinity entering the sedimentation basins. Hydrated lime [ Ca(OH) 2 \text{Ca(OH)}_2 Ca(OH) 2 , 100% active, where 1.0 mg/L lime yields 1.35 mg/L alkalinity as CaCO 3 \text{CaCO}_3 CaCO 3 ] is used for supplemental buffering.
Step 1: Calculate pure daily alum feed: Alum (lb/day) = 4.0 MGD × 28.0 mg/L × 8.34 = 934.08 lb/day \text{Alum (lb/day)} = 4.0\text{ MGD} \times 28.0\text{ mg/L} \times 8.34 = 934.08\text{ lb/day} Alum (lb/day) = 4.0 MGD × 28.0 mg/L × 8.34 = 934.08 lb/day
Step 2: Calculate alkalinity consumed by alum: Alkalinity Consumed = 28.0 mg/L alum × 0.45 mg/L Alk / mg/L Alum = 12.6 mg/L as CaCO 3 \text{Alkalinity Consumed} = 28.0\text{ mg/L alum} \times 0.45\text{ mg/L Alk / mg/L Alum} = 12.6\text{ mg/L as }\text{CaCO}_3 Alkalinity Consumed = 28.0 mg/L alum × 0.45 mg/L Alk / mg/L Alum = 12.6 mg/L as CaCO 3
Step 3: Determine remaining natural alkalinity: Remaining Alkalinity = 18.0 mg/L − 12.6 mg/L = 5.4 mg/L as CaCO 3 \text{Remaining Alkalinity} = 18.0\text{ mg/L} - 12.6\text{ mg/L} = 5.4\text{ mg/L as }\text{CaCO}_3 Remaining Alkalinity = 18.0 mg/L − 12.6 mg/L = 5.4 mg/L as CaCO 3
Step 4: Calculate required supplemental alkalinity: Deficit = 25.0 mg/L target − 5.4 mg/L remaining = 19.6 mg/L as CaCO 3 \text{Deficit} = 25.0\text{ mg/L target} - 5.4\text{ mg/L remaining} = 19.6\text{ mg/L as }\text{CaCO}_3 Deficit = 25.0 mg/L target − 5.4 mg/L remaining = 19.6 mg/L as CaCO 3
Step 5: Calculate required hydrated lime dosage: Lime Dose = 19.6 mg/L Alk 1.35 mg/L Alk / mg/L Lime = 14.52 mg/L Ca(OH) 2 \text{Lime Dose} = \frac{19.6\text{ mg/L Alk}}{1.35\text{ mg/L Alk / mg/L Lime}} = 14.52\text{ mg/L }\text{Ca(OH)}_2 Lime Dose = 1.35 mg/L Alk / mg/L Lime 19.6 mg/L Alk = 14.52 mg/L Ca(OH) 2
Step 6: Calculate daily lime mass feed rate: Lime Feed (lb/day) = 4.0 MGD × 14.52 mg/L × 8.34 = 484.39 lb/day \text{Lime Feed (lb/day)} = 4.0\text{ MGD} \times 14.52\text{ mg/L} \times 8.34 = 484.39\text{ lb/day} Lime Feed (lb/day) = 4.0 MGD × 14.52 mg/L × 8.34 = 484.39 lb/day
5. Rapid Mixing Hydraulics and Equipment
Rapid mixing (flash mixing) serves one singular, critical objective: to instantly and uniformly disperse the concentrated chemical coagulant throughout the entire raw water stream before primary hydrolysis and charge-neutralization reactions occur (which complete in less than 0.1 to 1.0 second ). +-------------------------------------------------------------+
- | RAPID MIX DESIGN PARAMETERS |
- | |
- | Hydraulic Retention Time (HRT): <1 to 30 seconds |
- | Velocity Gradient (G Value): 700 to 1,000+ s^-1 |
- | Camp Parameter (G x t): 10,000 to 30,000 |
- +-------------------------------------------------------------+
- The Velocity Gradient ( G G G )
The intensity of mixing is mathematically quantified by the velocity gradient ( G G G ), introduced by Camp and Stein: G = P μ V G = \sqrt{\frac{P}{\mu V}} G = μ V P
Where P P P is power dissipated into the water (ft-lb/s or Watts), μ \mu μ is dynamic viscosity (lb-s/ft² or Pa ⋅ s \text{Pa}\cdot\text{s} Pa ⋅ s ), and V V V is basin liquid volume (ft³ or m³). In rapid mixing, target G G G values range from 700 s − 1 700\text{ s}^{-1} 700 s − 1 to over 1 , 000 s − 1 1,000\text{ s}^{-1} 1 , 000 s − 1 .
Rapid Mix Technologies
Mechanical Flash Mixers : High-speed impellers (radial turbine or axial marine propellers rotating at 100–350 RPM) housed in small compartmentalized chambers with detention times of 10 to 30 seconds . If detention time exceeds 30 seconds, energy is wasted and early micro-flocs begin to shear.
Inline Static Mixers : Unpowered stationary geometric elements installed directly inside the raw water pipeline. As water flows through the helical vanes at high velocity ( > 4 – 6 ft/s >4\text{--}6\text{ ft/s} > 4 – 6 ft/s ), intense turbulent eddies and fluid shear instantly disperse chemicals with detention times < 2 seconds <2\text{ seconds} < 2 seconds and no mechanical drive maintenance.
Hydraulic Jumps : Coagulant is injected directly at the supercritical toe of a hydraulic jump formed across a Parshall flume or weir drop. High hydraulic energy dissipation achieves instantaneous, violent mixing without external electrical power.